Automatic Transformer Winding Analyser

Similar documents
TTR2796. Fully Automated Three Phase 250V Transformer Turns Ratio Meter FEATURES AND BENEFITS APPLICATIONS

Fully automated three phase 250V Transformer Turns Ratio Meter

TMS 580. Transformer Loss Measuring System FEATURES BENEFITS APPLICATIONS

GENERATOR TESTING APPLICATION GUIDE. reliable. precision.

MIDAS 2881 / 2881G. Mobile Insulation Diagnosis & Analysing System

700 Series AC Dielectric Test Sets

TRAINING OVERVIEW EDUCATION IS POWER. HIGH V O L T A G E T E S T S OLUTION S. reliable. precision.

TRAX Transformer and Substation Test System

TRAX Transformer and Substation Test System

KIT 4.0 HIGH VOLTAGE CONSTRUCTION KIT. reliable. precision. HIGH V O L T A G E T E S T S OLUTION S

Maintenance & Diagnosis Strategies. for. High Voltage Substations

TRAX Transformer and Substation Test System

TWA Series Three-Phase Winding Ohmmeters & Tap Changer & Winding Analyzers

True Three-Phase Transformer Turns Ratio Tester TRT400

Three-Phase Transformer Demagnetizer DEM60

CABLE FAULT LOCATING APPLICATION GUIDE. HIGH V O L T A G E T E S T S OLUTION S. reliable. precision.

Tap Changer Analyzer & Winding Ohmmeter RMO60TT

Tap Changer Analyzer & Winding Ohmmeter RMO-TT

Tap Changer Analyzer & Winding Ohmmeter RMO-TT

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

Mitigating Murphy s Law While Test. Frédéric Dollinger

Modular Partial Discharge (PD) & Radio Interference Voltage (RIV) Detector

True Three-Phase Transformer Turns Ratio Tester TRT30A

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

Tap Changer Analyzer & Winding Ohmmeter RMO-TD Series

Winding Ohmmeter RMO-TW

MIDAS Mobile Insulation Diagnosis & Analysing System. Features. Benefits. Applications

TRM-203/403 transformer resistance meters

True Three-Phase Transformer Turns Ratio Tester TRT63B

True Three-Phase Transformer Turns Ratio Tester TRT30A

FRAX Series Sweep Frequency Response Analyzers

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

Three-Phase Winding Ohmmeter TWA25K

MVCT. Megger VT & CT Analyzer. MVCT Megger VT & CT Analyzer

ON-SITE TESTING OF SPECIAL TRANSFORMERS

HiAS TM 744 HIGHEST RESOLUTION IMPULSE ANALYZING SYSTEM

True Three-Phase Transformer Turns Ratio Tester TRT63

SCOPE TRM 25 TRM 25+ Transformer Winding Resistance Meter. The most advanced Transformer Winding Resistance Meter injects up to 25A DC...

Chapter 7 Conclusion 7.1 General

TRM-203/TRM-403. transformer resistance meters. Vanguard Instruments Company, Inc.

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:

MODEL INFORMATION. Model AWRMS TM 200. Automated Winding Resistance Measurement System

True Three-Phase Transformer Turns Ratio Tester TRT40A

TESTRANO 600. Three-phase test system for comprehensive power transformer testing

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

Transformer test equipment easy to use

True Three-Phase Transformer Turns Ratio Tester TRT3x

OMICRON Seminar on Substation Testing and Diagnosis. October 23, 2017 Dubai, United Arab Emirates. October 24, 2017 Abu Dhabi, United Arab Emirates

True Three-Phase Transformer Turns Ratio Tester TRT4x

Three-Phase Transformer Turns Ratio Tester TRT03B

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser, OMICRON electronics Corp. USA

True Three-Phase Transformer Turns Ratio Tester TRT4x

Three-Phase Transformer Turns Ratio Tester TRT03C

Advanced Test Equipment Rentals ATEC (2832) CIBANO in-1 test system for medium- and high-voltage circuit breakers

H306 Series. AC/DC Benchtop Hipot Testers & Megohmmeter FEATURES BENEFITS APPLICATIONS

TESTRANO 600. Three-phase test system for comprehensive power and distribution transformer testing

CT Analyzer. Revolution in current transformer testing and calibration

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000

TesTIng of Power. Transformers are the largest, most. feature. By brandon dupuis

CP CU1. Coupling unit for line and ground testing

INSTRUCTION MANUAL ENGLISH

Three-Phase Transformer Turns Ratio Tester TRT03

Additel 875 Series Dry Well Calibrators

ABB Power Products Service

PCT200 SERIES CT/PT TEST SYSTEM USER MANUAL

TRANSFORMER OPERATIONAL PRINCIPLES, SELECTION & TROUBLESHOOTING

Končar TMS - Bushing monitoring

SG A. Impulse Voltage Test System, kv / kj APPLICATION

Specialists in HV and MV test and diagnostics. Testing in Substations

Additel 875 Series Dry Well Calibrators

TECHIMP Power Transformer Monitoring

Power Factor Insulation Diagnosis: Demystifying Standard Practices

TD-100. HAEFELY HIPOTRONICS Technical Document

AC Dielectric Test Sets

Three-Phase Transformer Test Systems

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

FRAX Series Sweep Frequency Response Analyzers

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

TESTRANO 600 ordering information

MEDIUM & HIGH VOLTAGE

Test description for dry-type transformers chapter for special tests

Understanding and Extracting Valuable Information from Basic and Advanced Power Transformer Testing Techniques

TD-106. HAEFELY HIPOTRONICS Technical Document. Partial Discharge Pulse Shape Analysis to Discriminate Near and Far End Failures for Cable Location

Testing and Diagnostic of Power Transformers & Distribution Transformers

Electrical Description

POWER TRANSFORMER. Failure Analysis & Troubleshooting. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

Transformer Factory Testing

Oberebenestrasse Bremgarten Switzerland Tel Fax

THE ELECTROM itig II MOTOR TESTER AND WINDING ANALYZER

7. INSPECTION AND TEST PROCEDURES

Innovative Test Techniques and Diagnostic Measurements to Improve the Performance and Reliability of Power System Transformers

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

Cable test vans and systems

Demagnetization of Power Transformers Following a DC Resistance Testing

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4

DC Resistance Meters 2840 Series

N. TEST TEST DESCRIPTION

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

Transcription:

2293 Automatic Transformer Winding Analyser The 2293 is an automatic winding analyser, optimized for three phase power and distribution transformer measurements. It uniquely combines winding resistance measurement, turns ratio, dynamic resistance measurement, core demagnetisation, transformer type detection, magnetic balance, short circuit impedance and heat run test (temperature rise and cooling curve) in the fastest single instrument solution on the market. A simple one-time-connection system drastically reduces measuring time: once connected all tests can be performed in a row without any reconnection. The built-in simultaneous winding magnetization method guarantees fast and reliable resistance measurements. Stable measurements are reached even on large power transformers with delta windings on the low voltage side. A progressive method for measuring transformer turns ratio guarantees results closer to the nominal ratio even in large power transformers with tertiary windings. Dynamic resistance measurement on tap changer perform an efficient and reliable check of the transformer tap changer. The demagnetisation function eliminates the magnetic remanence, which can cause faulty measurements, high inrush currents and incorrect operation of protective relays. Short circuit impedance test at reduced current helps locating mechanical damages. In addition the magnetic balance test can detect faults in the transformer magnetic core. Personnel safety is guaranteed by an emergency button as well as a state-of-the-art active discharge circuit and a caution indicator that continues to operate even without line power. An optional interlock connector can be ordered. FEATURES Multipurpose winding analyzer: transformer winding resistance, turns ratio, dynamic resistance on tap changer, type detection, arbitrary phase ratio measurement, demagnetisation, short circuit impedance, magnetic balance and heat run test (heat rise and cooling curve) in one instrument. Setup made easy simple one-time-connection system: once connected can perform all tests in all phases on both windings*. Easy operation on touch screen interface with full graphical test visualization. Unique simultaneous winding magnetisation method for winding resistance measurements, equivalent to traditional equipment with up to 100 A test current. Automated tap changer test by dynamic resistance (with optional tap changer controller). Advanced procedure for turns ratio and phase displacement measurement allows measurement also on non regular phase displacements (arbitrary phase shifted transformers). Demagnetisation function - transformer is returned to a demagnetized status after measurement. Automatic magnetic balance test for magnetic core fault detection. Short circuit test at reduced current for mechanical damages detection. Tap changer control signal. Data transfer over USB memory-stick or LAN. APPLICATIONS The 2293 is a valuable tool for factory test, acceptance test and regular maintenance on: Power and distribution transformers All type of HV windings * Except short circuit impedance, 1 / 8

MULTIPURPOSE MEASURING DEVICE The 2293 measures: Turns ratio Winding resistance Demagnetisation, Tap changer dynamic resistance Short circuit impedance, Magnetic balance Heat rise test Colling curve measurement All Test are done on all windings without any reconnections (Except short circuit impedance) RESISTANCE WINDING The Simultaneous Winding Magnetisation method together with the integrated DC power-supply guarantees fast and reliable winding resistance measurements. The 7 touch screen full graphical interface guides the operator through the single test procedures. Select Start Results COMPLETE AUTOMATIC TEST PROCEDURE Once the cable set is connected to the test object, the instrument will automatically measure the turns ratio of all taps. Then - without reconnection - the winding resistance can be measured followed by the demagnetisation function which will put the transformer in a demagnetised state. In addition, dynamic resistance and magnetic balance test will provide information about Select the test object by touching the appropriate icon and press start the unit then visualizes each test cycle and displays the results graphically or in list format. Independent currents can be selected for each winding, which guarantees reliable results even in transformers with large differences between windings. With one optional temperature probe (available for liquids and magnetic), results can be automatically referenced to any target temperature (for example 75 degrees). A complete transformer can be tested by a single person in a fraction of the time compared to traditional instruments 2 / 8

TURNS RATIO (OPTIONAL) The AC power-supply integrated in the 2293 allows full-automatic measurement of turns and voltage ratio, ratio deviation, phase displacement and excitation current of transformers. DEMAGNETISATION FUNCTION After a power or distribution transformer is disconnected from the power grid or when a DC current is applied to it, for example during a routine winding resistance measurement, the transformer core is likely to have some remnant magnetism. This remnant magnetism will generate high over currents when the transformer is reconnected to the grid, and this is commonly known as transformer Inrush Current. In addition, Magnetic remnant has an adverse effect on other measurements like FRA or TTR. The 2293 includes a fully automatic demagnetisation feature which eliminates the magnetic remnant. Select the winding where to perform the demagnetisation and press start the unit visualizes the whole demagnetisation cycle and performs the correct core demagnetisation in seconds. The specially developed algorithmic included in compensated mode reduces the influence of leakage flux while using low voltage, giving results much closer to the nominal ratio. The included type detection feature works as a nameplate guesser. It helps the user to determine the correct transformer configuration by showing the possible types and eliminating the wrong vectorgroups during the automatic detection process. SHORT CIRCUIT IMPEDANCE (OPTIONAL) MEASURING TRANSFORMERS WITH ARBITRARY PHASE- SHIFTS (OPTIONAL) Arbitrary phase shifts or those that do not follow the 30 phase steps between the primary and secondary winding are common in special transformers like phase-shifting, rectifier / furnace and traction transformers. Short circuit impedance is a routine test done to all transformers after manufacture and specified in the transformer nameplate. Changes in the short circuit impedance along transformer life is normally an indication of mechanical damages. The 2293 automatically performs a short circuit impedance test at reduced voltage on power and distribution transformers and calculates the three phase equivalent short circuit impedance for comparison with previous test or with nameplate values. With the optional Arbitrary Phase-Shift software key (2293/SKAP), the 2293 can measure turns and voltage ratio, phase displacement and excitation current of these special-type transformers. 3 / 8

MAGNETIC BALANCE TEST (OPTIONAL) Magnetic balance test is performed to detect faults in the magnetic core. The test looks for changes in the reluctance of the magnetic circuit caused by defects in the magnetic core structure, shifting or shape changes in the windings or inter turn insulation fault. The test is performed on three phase transformers by applying a voltage on one of the phases and measures the voltage on the other two. The induced voltage will depend on the limb position into the core as the following table. TAP CHANGER DYNAMIC RESISTANCE (OPTIONAL) On load tap changer main function is to switch between transformer taps without interrupting the current. The 2293 register the current while tap changer is operated and records the values at a defined sample rate. Discontinuities or Deviations between different taps are a sign of tap changer fault. F2 F3 E2 E1 E3 V F1 V Left phase Central Phase Right phase Voltage to left phase 100% 66% 33% Voltage to central phase 50% 100% 50% Voltage to right phase 33% 66% 100% The tap changer test with the 2293 is done automatically and without reconnection. In addition, the tap changer control accessory (optional) allows a complete automatic sequence without human intervention. The 2293 performs the magnetic balance test automatically and without any reconnection. Test results are shown graphically for a better understanding. Imbalances will be graphically noted including the involved phases. Calculation of the main curve parameters like time to rise, time to fall or Delta, for failure detection, is automatically done. 4 / 8

HEAT RUN TEST Heat run test on transformers consist of two steps; 1. Heat rise, where the transformer runs at nominal losses and transformer temperature rises. 2. Cooling curve, when transformer is disconnected and winding resistance is measured. TRANSFORMER MAINTENANCE MADE EASY Combine the Winding Analyzer 2293 with the MIDAS micro 2883 for an entire test solution on transformers. Compatible file formats allow data exchange between the two units and measurements results are combined for further analysis or processing. Heat Rise Cooling Curve The 2293 performs the measurements on both steps. It monitors the transformer temperature during the heat rise and measures HV and LV side resistances simultaneously during the cooling curve. For the Heat Rise (optional), connection of the temperature sensors could not be easier. The included 6 temperature inputs can be easily extended up to 30 by using the optional temperature extension box (2293/TEMP). The available magnetic and liquids temperature probes (2293/TEMP2, 2293/TEMP1) are easily connected to the transformer. Probe configuration is done graphically (oil, radiator top, radiator bottom, ambient ). In addition, pre-configured tests according ANSI and IEC standards are included, calculating the transformer temperature in real time and informing when stabilization is reached. Winding resistance Turns ratio Demagnetisation Dissipation Factor (tan ) Short circuit impedance Arbitrary phase shift For the cooling curve, the 2293 can measure HV and LV side resistances simultaneously and accurately. It provides efficient and accurate acquisition of the required data points to allow the user to draw the necessary cooling curve. Results can be easily exported to CSV files to calculate the winding temperature at switching off time. Magnetic Balance Excitation Current Heat Run Test Tap changer Dyn. Resistance 5 / 8

DATA HANDLING AND TEST REPORTS The 2293 allows easy data handling. Results can be saved on a USB memory stick or a simple test report can be printed with the built-in thermal printer. REMOTE CONTROL Remote control is also supported through the Ethernet interface. STANDARD SCOPE OF SUPPLY 2293 measuring device Eight measuring cables 10m each equipped with kelvin probes Cable bag Test certificate Instruction manual (English) VERSIONS 2293 Portable Version 2293R Rack Mounted Version SOFTWARE KEYS 2293/SKTTR 3-phase transformer turns ratio measurement add on application for 2293 2293/SKAP Arbitrary phase shift add on application for the 2293, (2293/SKTTR needed) 2293/SKTR Heat rise add on application for the 2293 2293/SKMB Magnetic balance add on application for the 2293 2293/SKTC Tap changer test, dynamic resistance 2293/SKSC Short circuit impedance measurement at reduced current OPTIONS 2293/TAP Tap changer control 2293/TEMP1 Temperature probe for liquids 2293/TEMP2 Magnetic temperature probe 2293/10HV 2293/10LV Extension cable 10m High voltage side Extension cable 10m low voltage side Extension cables can be plugged for longer distances 2293/TEMPEXT Temperature extension box to connect up to 8 additional temperature sensors. Up to three extension boxes (24 temperature inputs) can be connected to a single 2293. 2293/ITLOCK Safety interlock plug to stop test from an external switch 6 / 8

TECHNICAL SPECIFICATIONS Resistance Measurement Max. Measuring Current DC 32 A (user selectable) Max. Charging Voltage DC 100 V Range 0.1 μ 300 k Resistance range Accuracy (1) 0.1 μ... 300 μ 0.1% ± 0.5 μ 300.1 μ 30 k 0.1% 30.01 k 300 k 1% Ratio measurement Max. Supply Current ACΩ 1 A Peak / 700 ma RMS Max. Meas. Voltage AC 95 V Peak / 67 V RMS Range 1.0 100 000 Ratio range Accuracy (1) 1.0 100 0.05% 100 2 000 0.1% 2 000 20 000 1% 20 000 100 000 5% Phase (Ratio measurement) Typical Accuracy (2) 1.0 500 ±0.25 500 10 000 ±1.00 Phase (Clock number detection) Accuracy (2) 1.0 500 ±0.05 Temperature Temperature sensor Type PT 100 Class A Temperature sensor range Accuracy -50. +200 o C + 0.15 o + 0.2% t Measuring device range Accuracy -50. +200 o C + 0.25 o C Mains Power Supply Voltage 90 VAC 264 VAC Maximum Power 1000 W Frequency 47 Hz 63 Hz Environmental Operating temperature -10 C +60 C Storage temperature -20 C... +70 C Humidity 5% 95% r.h., non-condensing Vibration MIL-STD-810G Table 514.6C-II. Category Common carrier Mechanical Dimensions (W x D x H) Weight 521 mm x 425 mm x 216 mm 17.9kg General 8 measuring channels, 6 built-in temperature channels, 7 graphical touch screen interface, tap changer control signal, built-in printer, USB and LAN connections for data exchange (1) at temperature 0 +50 C at highest available current (2) at 0 +50 C at highest available voltage (3) Unit only without measuring cables 7 / 8

COMPLETE PORTFOLIO FOR TRANSFORMER TESTING TTR 2795 / TTR 2796 Transformer Turns Ratio Meter with 100/250 V test voltage Onsite testing of turns and voltage ratio, phase displacement and excitation current. Automatic winding connection identification and vector group detection. Remotely controllable via USB. FRA 5310 Frequency Response Analyser RVM 5462 Recovery Voltage Meter Detection of winding movements and mechanical failures of transformers. Active probing assures reliable and repetitive measurement results. Advanced analysis and touch screen operation. Mobile system for nondestructive diagnosis of the state of paper-oil insulation (effect of moisture content and aging) using the recovery voltage method. MIDAS MICRO 2883 Mobile Insulation, Diagnosis & Analysing system OC60E Oil Cell Tester Fully automated digital liquid electrical test set designed to reliably and accurately test the dielectric strength of insulation liquids. The MIDAS micro 2883 is the smallest and most compact insulation diagnosis set on the market. The weight of only 25 kg / 55 lbs and the one box design makes it the ideal tool for power / dissipation factor / tan δ OFFICES: Europe Haefely Test AG Birsstrasse 300 4052 Basel Switzerland + 41 61 373 4111 + 41 61 373 4912 sales@haefely.com China Haefely Test AG Representative Beijing Office 8-1-602, Fortune Street No. 67, Chaoyang Road, Chaoyang District Beijing, China 100025 + 86 10 8578 8099 + 86 10 8578 9908 sales@haefely.com.cn North America Hipotronics, Inc. 1650 Route 22 N Brewster, NY 10509 United States + 1 845 279 3644 + 1 845 279 2467 sales@hipotronics.com HAEFELY HIPOTRONICS has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice. 8 / 8 V08.15