New power tools provide quality and efficiency By

Similar documents
Understanding Harmonic Suppression Systems

The case of the hidden harmonic filter

Alternative Designs to Support Electronic Loads in Extensive UPS Distribution Systems

Harmonic Mitigating Transformer - Technical Guide

Dry Type Distribution Transformers NON-LINEAR TRANSFORMER PRESENTATION

HARMONIC MITIGATIONCASE STUDY

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services

Power Quality. Answering Today s Power Challenges. Why Your Existing Transformer May Be Inadequate. How Harmonics Affect Transformers

Multi-Pulse Rectifier Solutions for Input Harmonics Mitigation Applicable Product: F7, G7, P7 and E7

Unit 29 Three-Phase Transformers

Electromagnetic Harmonic Filters Technical Guide

POWER SYSTEMS QUALITY Topic 5: Principles for Controlling Harmonics

ASSOCIATION OF ENERGY ENGINEERS NORTHERN OHIO CHAPTER APRIL 21, 2005

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

22.0 Harmonics in Industrial Power Systems

Harmonic mitigating transformers. Energy savings through harmonic mitigation

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

Harmonic mitigating transformers. Energy savings through harmonic mitigation

Power Processor - Series 700F 10KVA to 150KVA

Presents. Harmonics Years

Generator Advanced Concepts

Tech Byte 16: The Truths About Transformers Part 2

thepower to protect the power to protect i-gard LITERATURE Low and medium voltage

Tuningintobetter power quality

HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N

Production power on a budget: How to generate clean reliable power, Part 2 By Guy Holt

Low Pass Harmonic Filters

Alternators Reactance for Nonlinear Loads

ULTRA-K Series 600K - he

Understanding Harmonics

Harmonic control devices. ECE 528 Understanding Power Quality

Emicon Engineering Consultants L.L.C.

Non-Linear Load Transformers

Harmonic Distortion Evaluations

Harmonics Elimination Using Shunt Active Filter

BUFFALO ENERGY SCIENCE AND TECHNOLOGY GROUP

Harmonic control devices

Effective Harmonic Mitigation with Active Filters

Strategies for design 600V large modular UPS for critical power applications

Harmonics I Harmonics White Paper. Power Protection Products, Inc. by Dan Maxcy l 2018 Update

Alternator winding pitch and power system design

ECET Modern Power

Harmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr.

Load Isolation Transformers

Guide to Harmonics. Reactive Power and Harmonic Compensation POWER QUALITY. The Basics of Harmonics

Energy Savings with an Energy Star Compliant Harmonic Mitigating Transformer

Section 11: Power Quality Considerations Bill Brown, P.E., Square D Engineering Services

Application of Tuned Passive Filter for Industrial Six-Pulse Rectifier with R-L Load Viralkumar A. Rana 1 Keyur Rana 2 Atul Talati 3

Active Harmonic Filter (AF3)

TECHNICAL BULLETIN 004a Ferroresonance

Power Factor & Harmonics

Thyristorised Automatic Power Factor

Mitigation of Harmonics Produced by Nonlinear Loads in Industrial Power System

High-Density Computing:

CASE STUDY. Implementation of Active Harmonic Filters at Ford Motor Company SA Silverton Plant

Voltage and Current Waveforms Enhancement using Harmonic Filters

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

Electromagnetic Harmonic Filters Technical Guide

UNBALANCED CURRENT BASED TARRIF

ECE 528 Understanding Power Quality

ENERGY SAVING WITH OPTIMIZATION OF VOLTAGE AND CURRENT QUALITY

Power Quality Monitoring and Power Metering Tutorial

Technical Paper. Harmonic Distortion in Data Centers

7/15/2002 PP.AFD.08 1 of 28

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Phase-phase/phase-neutral: 24/13.8 kv star, 13.8 kv delta, 12/6.9 kv star.

A PQ Case Study CS 36 HOSP 14. A Case Study OF Harmonics Mitigation in a Hospital and its Benefits

Inductance, capacitance and resistance

How adjustable speed drives affect power distribution

AC Sources for IEC 1000 Harmonics and Flicker Testing

PowerMonitor 5000 Family Advanced Metering Functionality

MIRUS International Inc.

Evaluation of Harmonic Suppression Devices

Table of Contents. Introduction... 1

OPTIMIZING MAINS IMPEDANCE: REAL WORLD EXAMPLES by Judith M. Russell Consulting Electrical Engineer PowerLines

This document covers common questions concerning the design of an effectively grounded system.

VFDs and Harmonics in HVAC Applications

Electrical Energy Saving and Economic Benefits from Power System Harmonics Mitigation in the Petrochemical Plants

Welcome to the rd. Annual Northern Ohio. 3 rd Energy Management Conference September 30, 2008

3/29/2012 MAIN TOPICS DISCUSSED ELECTRICAL SYSTEMS AND ELECTRIC ENERGY MANAGEMENT SECTION K ELECTRIC RATES POWER COMPUTATION FORMULAS.

Harmonics, its Mitigation & Result of Case study of Spinning Mill

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

General Description & Features Selection Charts Definition of Terms... 42

Electrical Theory. Power Principles and Phase Angle. PJM State & Member Training Dept. PJM /22/2018

E S C R I P T I V E B U L L E T I N .,.,.,. Bulletin DB-106. October, Square D Company Power System Studies ---1 I SQU ARED COMPANY --

An Introduction to Power Quality

2 Grounding of power supply system neutral

INTERIM ARRANGEMENTS FOR GRID TIED DISTRIBUTED ENERGY RESOURCES. Technical Requirements for Grid-Tied DERs

Open-Delta Systems Affect Variable Frequency Drives

Thermal Imaging, Power Quality and Harmonics

Harmonic Filters for Single Phase Equipment

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

VIENNA RECTIFIER FED BLDC MOTOR

McGill Power Sales & Engineering, INC.

Harmonic Solutions in Electrical Systems. Raed Odeh Application Specialist - Power Quality & Electrical Distribution

Please use the Q & A utility to ask us any questions concerning the material being presented.

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

GROUND-FAULT PROTECTION ON RESISTANCE-GROUNDED POWER-DISTRIBUTION SYSTEMS WITH ADJUSTABLE-SPEED DRIVES 1. Modified_103007

~=E.i!=h. Pre-certification Transformers

Transcription:

Typical Delta-wye transformer New power tools provide quality and efficiency By Steve Terry For quite some time, it has been well understood that phase-control SCR dimming systems used in the entertainment industry are producers of harmonic currents that require consideration in the design of the electrical system. Phase-control dimming systems are non-linear loads they do not draw current in a pure sine wave, but in a chopped version of a sine wave, depending on the aggregate level settings of all the dimmers in the system. These non-linear currents produce triplen harmonics (3rd, 9th, 15th, et cetera) of the fundamental 60 Hz or 50 Hz line frequency. Also known as zero-sequence harmonics, triplens on three phases add rather than cancel in the system neutral conductor. They can cause excessive heating of conductors, neutral overcurrents, nuisance tripping of circuit breakers, excessive heating of transformers, and excessive distortion of the voltage supplied to other equipment in a facility. The basic design of phase-control SCR dimmers dictates that they (and the loads connected to them) are harmonic-producing non-linear loads. There is no practical design change to an SCR dimmer that can change this fact. The trick in using phasecontrol dimmers effectively and efficiently is to insure that those harmonic currents do not create harmonic voltage distortion on the power line that supplies other equipment in a facility. To accomplish this, a number of tools have been used in the last 20 years. These tools have been effective in managing the harmonic problem, but now new developments in harmonic mitigation have increased system efficiency and decreased operating costs. In this article, we will explore the old, standard techniques and examine some of the new ones. K-Rated transformers the good and the bad One of the primary tools used to manage harmonics produced by phase-control dimming systems has been the delta-wye, K-rated transformer designed for non-linear loads. These transformers are constructed to withstand the additional heating produced by harmonic currents, accomplished through the use of more copper, different winding geometries, cooling ducts, more iron in the core, and an oversized neutral terminal. The delta-wye transformer configuration has always been an effective barrier to triplen harmonic currents, keeping them away from other parts of the electrical system, since they recirculate in the transformer s delta primary. This means increased power dissipation in the transformer, but it insures that the triplen harmonic currents do not propagate onto the rest of the electrical distribution system. Non-linear current waveform of a phase-control dimming system. 32

However, the K-rating of a transformer is only a survivability rating that guarantees the transformer will not overheat or be damaged in the presence of harmonic currents. It turns out that K- rated transformers suffer in two other areas of performance: n Excessive voltage distortion under non-linear loads n Low efficiency with low loads or no load The wye secondary of a K-rated transformer presents a relatively high impedance to triplen harmonic currents. This means that in the presence of these harmonic currents, the transformer responds by delivering a distorted voltage waveform to the load. High quality professional dimmers go to great lengths to maintain voltage regulation in the face of this voltage distortion, but it is far from ideal. Above certain distortion levels, the line barely resembles a sine wave, and even the best phase-control dimmers have trouble with stability and regulation. In electrical system design, engineers strive to achieve compliance with IEEE Standard 519-1992 Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems. This standard recommends maintaining the voltage quality in the system to not more than 5% total harmonic distortion (THD V ) a relatively pure sine wave. With a large phase-control dimming system and a K-rated transformer, it is often difficult or impossible to meet this standard. The best one can hope for is a dimming system that can tolerate the voltage distortion (often called self-pollution by dimmer designers) and a transformer that blocks the harmonic currents and resulting voltage distortion from the rest of the facility. Resulting distortion in the voltage waveform feeding the dimming system caused by the non-linear current waveform. An entertainment dimming system spends most of its life in an OFF or lightly loaded condition. In Europe, it is normal to deenergize the dimming system and any associated local transformer when the system is not being used. However, in North America the dimming system and its local transformer are likely to stay energized all the time. Even with no load, the transformer is consuming power and dissipating heat. A typical 500 kva, K-13 transformer can consume as much as 5 kw, 24 hours per day, 7 days per week, even where there is absolutely no load from the dimming system it is feeding. That is a big carbon footprint and big cost for power that is doing absolutely no work. And there is a further paradox: it is possible to improve the power quality (voltage distortion) of a K-rated transformer by over-sizing it. However, it then operates in a more lightly-loaded mode, which produces lower efficiency. Harmonic-Mitigating Transformers to the rescue A new tool has emerged in the last five years: the Harmonic- Mitigating Transformer (HMT). These devices are also known as zig-zag transformers due to the topology of their windings. This type of transformer was pioneered by companies such as PowerSmiths and Mirus, but is now available from virtually all major transformer manufacturers. HMTs minimize the voltage distortion in the presence of harmonic currents by reducing the impedance seen by the harmonic currents. This is accomplished through techniques such as zero sequence flux cancellation to kill triplen harmonics, and through phase shifting, which allows cancellation of the 5th, 7th, and 11th harmonics often seen in variable frequency drives, but not present in a typical phase-control dimming system. As such, this article will not delve into phaseshifting techniques. The secondary winding configuration of the HMT cancels the zero sequence fluxes (those produced by the 3rd, 9th, 15th triplen harmonics) without coupling them to the primary windings. The coil of wire used for each phase in the secondary winding is split between three poles of the iron transformer core. This flux cancellation also results in much lower impedance to the zero sequence currents and hence lower voltage distortion in the presence of these harmonic currents. In addition, the reduced primary winding circulating current will increase efficiency and allow the transformer to run cooler. An HMT has a cost premium over a K-rated or conventional transformer. However, the increase in efficiency and reduced no-load losses appear to generate relatively short payback periods for the higher capital cost. In addition, if you are looking for a green solution (see related article on page 42) to power consumption, this is it. The net results of using a Harmonic Mitigating Transformer: n Better power quality at input to dimmer system lower THD V n Big operating cost savings due to increased transformer efficiency and reduced no-load losses n Lower transformer heating n Reduced facility carbon footprint Finally, compatibility between entertainment phase-control dimmer systems and HMTs has been proven in a number of high-profile, 33 protocol

mission-critical installations such as NBC Studios in New York and the Wynn Hotel in Las Vegas. Harmonic blocking filters not for dimming systems Another solution that has been put forward is the harmonic blocking filter, or harmonic suppression system (HSS). This device is a resistive/inductive/capacitive (RLC) filter tuned to the third harmonic frequency of 180 Hz for a 60 Hz line. It is connected in series between the system neutral conductor and the neutral connection point of the secondary of the delta-wye transformer (and there is a whole other argument way beyond the scope of this article about whether that connection method is NECcompliant or safe). The device presents a very high impedance to third harmonic currents and a very low impedance to 60 Hz fundamental currents. This prevents harmonic currents from flowing in the neutral and thus the phase conductors as well. But, remember our discussion of K-rated transformers above? They also present a high impedance to third harmonic currents, and the result is voltage distortion or poor power quality. It turns out that with harmonic blocking filters, just as Robert Heinlein said, Tanstaafl applies. There ain t no such thing as a free lunch. Blocking filters suppress the third harmonic current in the neutral and thus the phase conductors, but at the expense of tremendous third-harmonic voltage distortion. Proponents of harmonic blocking filters argue that the devices connected to the line that created the harmonics to begin with are likely to be personal computers or office equipment with switch-mode power supplies. They go on to prove that such devices do not mind excessive voltage distortion. In fact, their argument suggests that switch-mode power supplies actually operate more efficiently with excessive voltage distortion caused by triplen harmonics. That may be true, and it is probably just fine if the only thing connected to the filter is this type of device. Remember our phase-control dimming system that might be connected to the filter? It simply cannot perform well when presented with a flat-topped, almost trapezoidal waveform that bears little resemblance to a sine wave. And that is what the harmonic blocking filter produces. The result may be flickering dimmers, poor output regulation, or other failure modes. The bottom line: Stay away from any tuned Harmonic Blocking Filter in the feed to a phase-control dimming system. What about sine wave dimmers? No discussion of dimming systems and power quality or efficiency would be complete without mentioning sine wave dimmers, a new 34

technology that has come to market in the last five years. Sine wave dimmers produce a nearly pure, sine wave output (generally as good as the sine wave on the line they are fed from). Their primary benefit is reduction of lamp filament noise and the ability to dim many types of loads. A strong secondary benefit is the fact that a sine wave dimmer draws current in a sinusoidal waveform, and is therefore considered a linear load. To acknowledge this, the upcoming 2008 National Electrical Code has two new definitions added to Article 520, covering Theaters [sic], Audience Areas of Motion Picture and Television Studios, and Similar Locations: Solid-State Phase-Control Dimmer. A solid-state dimmer where the wave shape of the steady-state current does not follow the wave shape of the applied voltage, such that the wave shape is non-linear. Solid-State Sine-Wave Dimmer. A solidstate dimmer where the wave shape of the steady-state current follows the wave shape of the applied voltage, such that the wave shape is linear. In addition, Sections of Article 520 and 518 (Assembly Occupancies) that previously required the neutral feeding solid-state dimming systems to be considered a current-carrying conductor (for wire and conduit fill de-rating to deal with harmonic-produced neutral currents) have been modified. Now, dimming systems that use only sine wave dimmers no longer need to consider the neutral a current carrying conductor. However, systems that use a mix of sine wave and phase-control dimmers, or that can have phase-control dimmers interchangeably field installed with sine wave dimmers, must continue to consider the neutral a current-carrying conductor. So, this sounds like an indication that sine wave dimmers are the answer to all our efficiency, harmonic mitigation, and power quality problems, right? Yes, but for one consideration: cost. Where sine wave 35 protocol

dimmers are needed for absolute quiet in a facility, or to dim a wide variety of load types, their high cost is easily justified. They bring along the added icing on the cake benefit of lower installation costs because they are linear loads. Standard transformers can be used, and neutral overcurrents are a thing of the past. However, sine wave dimmers are still generally thought to be too costly to be justified only as a harmonic mitigating tool. Legislated power quality? For some years, there has been a threat that government in Europe and eventually North America might legislate regulations that would obsolete high power phasecontrol dimmers used in entertainment systems due to their harmonic current waveforms. This has not happened yet, for a number of reasons, not least of which is the very small number of these systems in the world compared to other harmonic producers (arc furnaces, variable-frequency motor drives, and others), as well as the very low duty cycle of entertainment dimming systems. Such proposed legislation was thought to be driven by power utilities who wanted to avoid power quality pollution on their systems and the generation of reactive power that cannot be billed to customers and does no real work. Every discussion of harmonic mitigation (engineered or legislated) has focused on the point of common coupling or PCC. This is the point at which customer A s and customer B s electrical systems meet. In North America, this is usually the primary side of a facility s transformer. The goal of any proposed legislation is to prevent power line pollution from one customer from reaching the facility of another customer or the utility s distribution infrastructure. The proposed regulations care little about selfinduced power pollution on sections of the electrical system within a facility. The PCC discussion relates to harmonic currents of entertainment dimming systems, since a local Harmonic Mitigating Transformer is a very effective, efficient, and economical means of stopping the propagation of harmonic currents beyond the transformer-to-dimmer system connection. Should the threatened legislation ever occur, the HMT could be a valuable tool to make phase control dimmer systems compliant with new regulations. n Steve Terry is the Vice President of Research and Development at ETC, where he is responsible for global product development. He is the Co-Chair of the ESTA Control Protocols Working Group, a Fellow of the USITT, and the alternate USITT representative to National Electrical Code Panel 15. 36