Load Frequency Control An ELC based approach

Similar documents
CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Simulation of Advanced ELC with Synchronous Generator for Micro Hydropower

UNIVERSITY OF CALGARY. Fuzzy Logic Controller for a Hydro Pumped Storage Plant to Provide Frequency Regulation in. an Isolated Hybrid Micro-Grid

Pid Plus Fuzzy Logic Controller Based Electronic Load Controller For Self Exited Induction Generator.

Objective: Study of self-excitation characteristics of an induction machine.

Hybrid Anti-Islanding Algorithm for Utility Interconnection of Distributed Generation

IMPROVING EFFICIENCY OF ACTIVE POWER FILTER FOR RENEWABLE POWER GENERATION SYSTEMS BY USING PREDICTIVE CONTROL METHOD AND FUZZY LOGIC CONTROL METHOD

Experimental Investigation of Power Quality Disturbances Associated with Grid Integrated Wind Energy System

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

TWO AREA CONTROL OF AGC USING PI & PID CONTROL BY FUZZY LOGIC

Power Quality improvement of a three phase four wire system using UPQC

Improvement of Power Quality in PMSG Based Wind Integrated System Using FACTS Controller

GRID CONNECTED HYBRID SYSTEM WITH SEPIC CONVERTER AND INVERTER FOR POWER QUALITY COMPENSATION

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015

CHAPTER 6 ANALYSIS OF THREE PHASE HYBRID SCHEME WITH VIENNA RECTIFIER USING PV ARRAY AND WIND DRIVEN INDUCTION GENERATORS

Study on Voltage Controller of Self-Excited Induction Generator Using Controlled Shunt Capacitor, SVC Magnetic Energy Recovery Switch

Improved Electronic Load Controller for Three Phase Isolated Micro-Hydro Generator

Comparative Analysis of Multiple-pulse VSC-Based STATCOM s for Voltage-Dip Mitigation

A Fuzzy Controlled PWM Current Source Inverter for Wind Energy Conversion System

Voltage Support and Reactive Power Control in Micro-grid using DG

Islanding Detection Method Based On Impedance Measurement

Design and Implementation of Closed Loop LCL-T Resonant DC-to- DC Converter Using Low Cost Embedded Controller

Eyenubo, O. J. & Otuagoma, S. O.

HARMONIC ELIMINATION IN THREE PHASE SYSTEM BY MEANS OF A SHUNT ACTIVE FILTER

HARMONICS MITIGATION USING FUZZY CONTROLLER FOR GRID CONNECTED DOUBLY FED INDUCTION WIND GENERATORS

Design, Implementation, and Dynamic Behavior of a Power Plant Model

Analysis of Effect on Transient Stability of Interconnected Power System by Introduction of HVDC Link.

Power quality improvement of self- excited induction generator using Multipulse AC-DC converters - A comparison

EASTERN ILLINI ELECTRIC COOPERATIVE Application for Operation of Member-Owned Generation

Governor with dynamics: Gg(s)= 1 Turbine with dynamics: Gt(s) = 1 Load and machine with dynamics: Gp(s) = 1

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Transient Analysis of Self-Excited Induction Generator with Electronic Load Controller (ELC) for Single-Phase Loading

WILEY CONTROL OF POWER INVERTERS IN RENEWABLE ENERGY AND SMART GRID INTEGRATION. Qing-Chang Zhong. Tomas Hornik IEEE PRESS

Wind energy conversion system based on Vienna rectifier with fuzzy logic control technique

PART 1 OWNER/APPLICANT INFORMATION

Owner/Customer Name: Mailing Address: City: County: State: Zip Code: Phone Number: Representative: Address: Fax Number:

EXCITATION SYSTEM MODELS OF GENERATORS OF BALTI AND EESTI POWER PLANTS

Doãn Văn Đông, College of technology _ Danang University. 2. Local Techniques a. Passive Techniques

CHAPTER 4 ON LINE LOAD FREQUENCY CONTROL

Stability of Voltage using Different Control strategies In Isolated Self Excited Induction Generator for Variable Speed Applications

Analysis and modeling of thyristor controlled series capacitor for the reduction of voltage sag Manisha Chadar

FUZZY CONTROLLED DSTATCOM FOR HARMONIC COMPENSATION

Methods to Enable Open-Loop Synchronization For Islanded Systems

Application of Sparse Matrix Converter for Microturbine-Permanent Magnet Synchronous Generator output Voltage Quality Enhancement

Auxiliary DC Voltage

IJESRT. (I2OR), Publication Impact Factor: (ISRA), Impact Factor: Student, SV University, Tirupati, India.

Design and Development of MPPT for Wind Electrical Power System under Variable Speed Generation Using Fuzzy Logic

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Electronic Load Controller for Self Exited Induction Generator Using Fuzzy Logic Controller

Analysis of Single Phase Self-Excited Induction Generator with One Winding for obtaining Constant Output Voltage

Volume I Issue VI 2012 September-2012 ISSN

Active Rectifier in Microgrid

Control of Power Converters for Distributed Generation

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control

HISTORY: How we got to where we are. March 2015 Roy Boyer 1

Simulation of Dc-Link Power Converter for Integrating Offshore Wind Turbine Generator to Grid

COMPUTATION OF STABILIZING PI/PID CONTROLLER FOR LOAD FREQUENCY CONTROL

Load frequency control in Single area with traditional Ziegler-Nichols PID Tuning controller

A New Control Strategy for Three- Phase Inverter Applied To Induction Motor of Micro Grid

Development of a Frequency-stabilizing Scheme for Integrating Wind Power Generation into a Small Island Grid

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

CHAPTER 4 FUZZY BASED DYNAMIC PWM CONTROL

Grid Interconnection of Wind Energy System at Distribution Level Using Intelligence Controller

Design and Construction of Synchronizing Check Relay

Adaptive ANN based STATCOM and DVR for optimal integration of wind energy with grid using permanent magnet synchronous generator

SPACE VECTOR PULSE WIDTH MODULATION SCHEME FOR INTERFACING POWER TO THE GRID THROUGH RENEWABLE ENERGY SOURCES

Control schemes for shunt active filters to mitigate harmonics injected by inverted-fed motors

SOUTH CENTRAL INDIANA REMC Application for Operation of Member-Owned Small Power Generation Systems

Modeling & Simulation of Permanent Magnet Synchronous Wind Generator Based Stand-alone System

A Novel Islanding Detection Technique for Distributed Generation (DG) Units in Power System

DSP-Based Simple Technique for Synchronization of 3 phase Alternators with Active and Reactive Power Load Sharing

CHAPTER 6 MITIGATION OF VOLTAGE SAG, SWELL AND SINGLE PHASE OUTAGE USING MULTI WINDING TRANSFORMER

Integrated Electronic Load Controller with T-Connected Transformer for Isolated Asynchronous Generator

STATCOM BASED ON REDUCTION OF PQ ISSUES IN MICRO GRID APPLICATION SYSTEMS

Available online at ScienceDirect. Energy Procedia 57 (2014 )

Alleviation of harmonics for the self excited induction generator (SEIG) using shunt active power filter

CHAPTER 7 CONCLUSIONS AND FUTURE SCOPE

A MATLAB-SIMULINK APPROACH TO SHUNT ACTIVE POWER FILTERS

Investigation of Magnetic Field and Radial Force Harmonics in a Hydrogenerator Connected to a Three-Level NPC Converter

CHAPTER 4 MODIFIED H- BRIDGE MULTILEVEL INVERTER USING MPD-SPWM TECHNIQUE

POWER ISIPO 29 ISIPO 27

CHAPTER 6 THREE-LEVEL INVERTER WITH LC FILTER

Implementation of Sparse LMS Control Algorithm in DSTATCOM

Research Article International Journals of Advanced Research in Computer Science and Software Engineering ISSN: X (Volume-7, Issue-6)

Fuel cell power system connection. Dynamics and Control of Distributed Power Systems. DC storage. DC/DC boost converter (1)

B.Tech Academic Projects EEE (Simulation)

Power Quality Improvement in Conventional Electronic Load Controller. for an Isolated Power Generation

II. RESEARCH METHODOLOGY

Performance Evaluation of PWM Converter Control Strategy for PMSG Based Variable Speed Wind Turbine

Improvement of Power Quality Considering Voltage Stability in Grid Connected System by FACTS Devices

Development and Simulation of Dynamic Voltage Restorer for Voltage SAG Mitigation using Matrix Converter

DESIGN OF ELECTRONIC LOAD CONTROLLER BY USING COMBINATION METHOD FOR MICRO-HYDRO POWER PLANT AND ITS CONTROL AND MONITORING PROGRAM SIMULATION

Development of an Experimental Rig for Doubly-Fed Induction Generator based Wind Turbine

Integration of Photovoltaic Energy to the Grid, Using the Virtual Synchronous Generator Control Technique

We can utilize the power flow control ability of a TCSC to assist the system in the following tasks:

Photovoltaic System Based Interconnection at Distribution Level With Different Loads

STABILITY IMPROVEMENT OF POWER SYSTEM BY USING PSS WITH PID AVR CONTROLLER IN THE HIGH DAM POWER STATION ASWAN EGYPT

An Interleaved Flyback Inverter for Residential Photovoltaic Applications

Development of Multilevel Inverters for Control Applications

Diode Clamped Multilevel Inverter for Induction Motor Drive

Transcription:

Load Frequency Control An ELC based approach Ashwin Venkatraman 1, Paduru Kandarpa Sai 2, Mohit Gupta 3 1Electrical Engineering Department, Indian Institute of Technology Jodhpur 2Electrical Engineering Department, Indian Institute of Technology Jodhpur 3Electrical Engineering Department, Indian Institute of Technology Jodhpur ---------------------------------------------------------------------***--------------------------------------------------------------------- Abstract - The aim of this study is to design an Electronic Load Controller (ELC) for a stand-alone micro-hydro generation network. In a stand-alone micro-grid, frequency control is a main concern. At any given instant, power balance in the system must be maintained by continuously matching the power supplied by the generators with the power consumed by the loads. In order to achieve Load Frequency Control (LFC) for the system, a dump load controlled by a frequency controller is used, which varies the dump load resistance based on the output of the controller. All simulations were carried out in MATLAB/Simulink environment. Key Words: Load Frequency Control, Frequency Regulators, Control Pulse Generator, Dump Load. 1. INTRODUCTION Micro-grids powered by Renewable Energy Sources (RES) are becoming increasingly popular and are extensively studied due to their insignificant environmental impact compared to the classical power plants. A stand-alone micro grid needs to be self-sufficient when it comes to power quality, especially regulation of voltage and frequency. Voltage variations are related to the reactive power of the system whereas frequency is related to the active power in the system. Thereby, to achieve frequency control, active power balance is essential. To ensure a functional and reliable grid, the instantaneous frequency must be maintained very close to the original grid frequency (60 Hz or 50 Hz depending on the region). When the generation and demand are exactly matched, the grid frequency is held at a constant level. In a practical power systems situation, the load, which actually is the consumer load, varies continuously, thereby making some kind of control method a major necessity. Therefore, frequency control has been studied extensively in literature, with a wide variety of methods available for the same. Usually, it is achieved by controlling the mechanical power of the prime mover of generators. The efficiency of such a control strategy should be high as the generated power is maintained in range of the power demand. But, due to the mechanical constraints, the regulating process is slow and the overall cost is also significant. Moreover, the system response to sudden load changes is poor, thereby resulting in voltage sags and frequency deviations. [1] But, for low power systems, such as micro-hydro generation system, the easier and cost-efficient way is to use ELC instead of controlling the mechanical side of the generator. The operating principle of such an ELC is that it the total generated power equals the sum of power consumed by consumer s loads and the ELC. As active power balance is achieved, frequency is satisfactorily regulated. Moreover, this energy can be transformed into other forms of energy [1-3] such as heat, or can be stored for usage during periods of lack of energy. Various ELC topologies have been studied and reported. A few of them include power electronics based controllers [1-3, 6-8] and fuzzy logic based controllers [4-5]. This paper discusses a control method where the dump load resistance is varied in levels based on the output of a frequency controller. The system analyzed is a stand-alone micro-grid supplied by a micro-hydro generator, which is modelled using a Synchronous Generator (SG) driven by constant speed hydraulic turbines. The simplified diagram of the system as a whole is given in Fig 1. 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 198

2. SYSTEM DESCRIPTION The power source in this system is a micro-hydro generator, whose Simulink model is given in Fig 2. The Synchronous generator is 100kVA/480 V and 60 Hz and is driven by a Hydraulic turbine system. The Hydraulic Turbine System implements a hydraulic turbine combined to a PID governor system and the excitation system acts as the voltage regulator combined with an exciter. The generator supplies both the consumer load as well as the dump load. The consumer load is modelled using two constant 3 phase resistive loads with a breaker connected to one of them to simulate the load variations. A fixed value terminal capacitor is added in order to result in rated terminal voltage at full load. The output power of the generator must be held constant at all consumer loads as any decrease in the consumer load may accelerate the machine and raise the voltage and frequency levels over the tolerable limit, which in case of frequency is usually +- 0.5 Hz. This would also result in increased stress on other loads. The excess power is hence supplied to the dump load through the controller so that P g = P c + P dl where P g is generated power, P c is the power consumed by the consumer load and P dl is the power consumed by the dump load. The other block in the control system is that of the dump load. It takes a stream of 8 bits as input and based on the values of the bits, the resistance is varied in 256 different levels. The dump load resistance was chosen as 100 kw and it was varied from 0 to 100kW in steps of 0.4 kw each. In order to further reduce the harmonics generated, harmonic filter block available in Simulink was used in the load side. Fig -1: Overall System Diagram The frequency controller is used to generate control pulses, which is then fed as input to the dump load. The dump load resistance is then varied depending on the value of the pulses generated. 3. CONTROL STATEGY The Simulink model of the load part of the system is shown in Fig 3. It consists of a 3 phase resistive load of 60 kw rating, which is the main load, and a 3 phase resistive load of 10 kw rating that is connected in series with a 3 phase breaker, which is used to simulate the variation in consumer load. The control system consists of two blocks. The first one is a control pulse generator, which generates a total of 24 pulses, 8 per each phase. It consists of a 3 phase PLL, which measures the frequency. It is then compared with the reference frequency of 60 Hz and the resultant error signal is passed through an integrator in order to get the phase error. The phase error is then passed through a PID controller and thereafter, the resultant output is converted into 8 bit output. Fig -2: Simulink Model of Micro-Hydro Generation System This is then used to generate a 24 bit output (8 per each phase). In order to reduce switching losses and other related voltage disturbances, Zero-Voltage Switching (ZVS) is used. 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 199

Fig 11 shows the rotor speed of the synchronous generator. Fig -3: Simulink Model of Consumer Load and Dump Load 4. SIMULATION RESULTS AND DISCUSSIONS All simulations were carried out in MATLAB/Simulink. The synchronous generator was rated 100kVA, 480 V and 60 Hz, salient pole machine with 2 pole pairs. The breaker used to simulate the variations in the consumer load was initially open with transition times 0.5 s, 1 s, 1.5 s and 2 s. Fig -4: Frequency Fig 4 shows the frequency of the system for the simulation time of 15 s. The initial variation in the frequency is within the accepted norm of 0.5 Hz. It is observer that the steady state value of frequency is 60 Hz, thereby verifying that the proposed control method is successful. Fig 5 and 6 presents the various power measurements, namely generated power, power consumed by the consumer load and power consumed by the dump load. It is observed from the graphs that the power expression mentioned earlier is valid. Fig -5: Generated Power Fig 7 presents the voltage and current measured at the generator. Fig 8 shows the harmonics calculation done on the source voltage, which comes out to be 2.16%. Fig 9 shows the voltage and current measured at the consumer load whereas Fig -6a: Power Consumed by Main Load Fig 10 shows the voltage measured at the dump load. 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 200

Fig -6b: Power Consumed by Dump Load Fig -8: Total Harmonic Distortion Fig -7a: Vabc Generated Fig -9a: Vabc at Main Load Fig -7b: Iabc Generated Fig -9b: Iabc at Main Load 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 201

ACKNOWLWDGEMENT We would like to take this opportunity to express our deep sense of gratitude and profound feeling of admiration to our supervisor Dr. Abdul Gafoor Shaik. REFERENCES Fig -10: Vabc at Dump Load Fig -11: Rotor Speed [1] I. Şerban, C.P. Ion, C. Marinescu, Frequency Control and Unbalances Compensation in Autonomous Micro-Grids Supplied by RES, The IEEE International Electric Machines and Drives Conference, CD Proceedings, Turkey, May 2007. [2] R. Sebastian, J. Quesada, Distributed Control System for Frequency Control in a Isolated Wind System, Science- Direct Renewable Energy, 31, 3, pp. 285 305 (2006). [3] I. Şerban, C. Ion, C. Marinescu, M. N. Cîrstea, Electronic Load Controller for Stand-Alone Generating Units with Renewable Energy Sources, The 32nd annual conference of the IEEE Industrial Electronics Society IECON 06, Paris, France, 2006, pp. 4309 4312. [4] C.S. Chang, W. Fu Area load-frequency control using fuzzy gain scheduling of PI controllers Electr. Power Syst. Res, 42 (1997), pp. 145 152 [5] Z.M. Ai-Hamouz, Y.L. Abdel-Magid Variable-structure load-frequency controllers for multi area power systems Int. J. Electr. Power Energy Syst, 15 (5) (1993), pp. 23 29 [6] M.Deb, A.Das, G.Deb, Control of Voltage and Frequency of a Wind Electrical System using Frequency Regulator, International Journal of Engineering Research & Technology (IJERT) Vol. 3 Issue 3, March 2014. [7] Juan M. Ramirez, Emmanuel Torres M, An Electronic Load Controller for Self-Excited Induction Generators. [8] I. Şerban, C. Marinescu Power Quality Issues In A Stand- Alone Microgrid Based On Renewable Energy, Revue Roumaine Des Sciences Techniques - Serie Électrotechnique Et Énergétique January 2008 5. CONCLUSIONS Frequency control in a stand-alone micro-grid system was studied. An ELC was designed and developed in MATLAB/Simulink environment. From the simulated results, it can be concluded that the developed ELC for the system maintains the voltage and the frequency at a constant value despite variations in the consumer load. Moreover, the Total Harmonic Distortion (THD) of ELC is 2.16%, thereby exhibiting a satisfactory performance. Hence, the proposed system can be used in micro-hydro applications in remote locations/hilly areas. \ 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 202