Analysis of Utility Interactive Photovoltaic Generation System using a Single Power Static Inverter

Similar documents
Grid Connected Photovoltaic Micro Inverter System using Repetitive Current Control and MPPT for Full and Half Bridge Converters

THE converter usually employed for single-phase power

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

CHAPTER 3 APPLICATION OF THE CIRCUIT MODEL FOR PHOTOVOLTAIC ENERGY CONVERSION SYSTEM

An Interleaved Flyback Inverter for Residential Photovoltaic Applications

Chapter 3 : Closed Loop Current Mode DC\DC Boost Converter

A Pv Fed Buck Boost Converter Combining Ky And Buck Converter With Feedback

Grid-Tied Home Energy Production Using a Solar or Wind Power Inverter without DC-to-DC Converter

Solar fed Induction Motor Drive with TIBC Converter and Voltage Multiplier Circuit

Grid Connected photovoltaic system based on Chain cell converter Using Simulink

Transformer less Grid Connected Inverter with Leakage Current Elimination

High Step-Up DC-DC Converter

D-Σ Digital Control for Improving Stability Margin under High Line Impedance

CHAPTER 3. SINGLE-STAGE PFC TOPOLOGY GENERALIZATION AND VARIATIONS

An Interleaved High Step-Up Boost Converter With Voltage Multiplier Module for Renewable Energy System

An Interleaved High-Power Fly back Inverter for Photovoltaic Applications

Lecture 19 - Single-phase square-wave inverter

DESIGN & SIMULATION OF LOW POWER HOME UTILITY GRID CONNECTED PV SYSTEM USING P&O METHOD

CHAPTER 7 MAXIMUM POWER POINT TRACKING USING HILL CLIMBING ALGORITHM

Power Factor Pre-regulator Using Constant Tolerance Band Control Scheme

Design of Single Phase Pure Sine Wave Inverter for Photovoltaic Application

Analysis and Design of Solar Photo Voltaic Grid Connected Inverter

Comparison between the Performance of Basic SEPIC Converter and modified SEPIC Converter with PI Controller

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 01, 2016 ISSN (online):

MPPT based New Transformer Less PV Inverter Topology with Low Leakage Current

CHAPTER 5 MODIFIED SINUSOIDAL PULSE WIDTH MODULATION (SPWM) TECHNIQUE BASED CONTROLLER

Inverter topologies for photovoltaic modules with p-sim software

CHAPTER 6 ANALYSIS OF THREE PHASE HYBRID SCHEME WITH VIENNA RECTIFIER USING PV ARRAY AND WIND DRIVEN INDUCTION GENERATORS

CHAPTER 3 CUK CONVERTER BASED MPPT SYSTEM USING ADAPTIVE PAO ALGORITHM

Figure.1. Block of PV power conversion system JCHPS Special Issue 8: June Page 89

Harmonic Analysis of 1.5 kw Photovoltaic System in the Utility Grid

Experimental Implementation of a Low-Cost Single Phase Five-Level Inverter for Autonomous PV System Applications Without Batteries

A Three Phase Power Conversion Based on Single Phase and PV System Using Cockcraft-Walton Voltage

NON ISOLATED HIGH GAIN TWO INDUCTOR BOOST CONVERTER FOR SOLAR PV APPLICATIONS

SIMULATION STUDIES OF HALF-BRIDGE ISOLATED DC/DC BOOST CONVERTER

Active and Reactive Power Control for a Single- Phase Grid-Connected PV System with Optimization of the Ferrite Core Volume

A New Three-Phase Interleaved Isolated Boost Converter With Solar Cell Application. K. Srinadh

Three-phase Rectifier Using a Sepic DC-DC Converter in Continuous Conduction Mode for Power Factor Correction

Boost Converter with MPPT and PWM Inverter for Photovoltaic system

THE CONVENTIONAL voltage source inverter (VSI)

Modelling of Single Stage Inverter for PV System Using Optimization Algorithm

Comparison of Voltage and Efficiency of a Modified SEPIC Converter without Magnetic Coupling and with Magnetic Coupling

PERFORMANCE EVALUATION OF THREE PHASE SCALAR CONTROLLED PWM RECTIFIER USING DIFFERENT CARRIER AND MODULATING SIGNAL

Power Factor Correction of LED Drivers with Third Port Energy Storage

Delhi Technological University (formerly DCE) Delhi-42, India

Self-oscillating Auxiliary Medium Open Loop Power Supply Deploying Boost EIE Converter

A Double ZVS-PWM Active-Clamping Forward Converter: Analysis, Design, and Experimentation

Modeling of Single Stage Grid-Connected Buck-Boost Inverter for Domestic Applications Maruthi Banakar 1 Mrs. Ramya N 2

Simulation and Analysis of a Multilevel Converter Topology for Solar PV Based Grid Connected Inverter

Levels of Inverter by Using Solar Array Generation System

Photovoltaic Systems Engineering

A Single Phase Multistring Seven Level Inverter for Grid Connected PV System

A Color LED Driver Implemented by the Active Clamp Forward Converter

Minimization of Switching Devices and Driver Circuits in Multilevel Inverter

A Current Sensor-less Maximum Power Point Tracking Method for PV

Modeling and Simulation of Synchronizing System for Grid-Connected PV/Wind Hybrid Generation

Multilevel Inverter for Grid-Connected PV SystemEmploying MPPT and PI Controller

Analysis, Design and Development of a Single Switch Flyback Buck-Boost AC-DC Converter for Low Power Battery Charging Applications

Single-Stage Power Electronic Converters with Combined Voltage Step-Up/Step-Down Capability

Current Rebuilding Concept Applied to Boost CCM for PF Correction

Design And Analysis Of Dc-Dc Converter For Photovoltaic (PV) Applications.

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

Photovoltaic Battery Charging System Based on PIC16F877A Microcontroller

Linear Peak Current Mode Controlled Non-inverting Buck-Boost Power-Factor-Correction Converter

Abstract. Keywords: Electric vehicle; Modelling; Pulse Width Modulation (PWM) inverters; MOSFET circuits.

Simulation of Standalone PV System Using P&O MPPT Technique in Matlab/Simulink

Comparison Between two Single-Switch Isolated Flyback and Forward High-Quality Rectifiers for Low Power Applications

Design and Implementation of Single-Stage Grid-Connected Flyback Microinverter Operates in DCM for Photovoltaic Applications

MUCH effort has been exerted by researchers all over

A Three Phase Seven Level Inverter for Grid Connected Photovoltaic System by Employing PID Controller

Shunt Active Power Filter connected to MPPT based photo voltaic Array for PQ enhancement

Fabiana Pottker de Soma and Ivo Barbi

International Journal of Engineering Science Invention Research & Development; Vol. II Issue VIII February e-issn:

International Journal of Advance Engineering and Research Development

DESIGN OF SINGLE-STAGE BUCK BOOT CONVERTER FOR INVERTER APPLICATIONS

A Detailed Comparative Analysis between two Soft Switching techniques used in PV Applications

466 IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 13, NO. 3, MAY A Single-Switch Flyback-Current-Fed DC DC Converter

Application of Model Predictive Control in PV-STATCOM for Achieving Faster Response

CHAPTER 3 MAXIMUM POWER TRANSFER THEOREM BASED MPPT FOR STANDALONE PV SYSTEM

Microcontroller Based MPPT Buck-Boost Converter

Chapter 1: Introduction

HIGH RELIABILITY AND EFFICIENCY OF GRID-CONNECTED PHOTOVOLTAIC SYSTEMS USING SINGLE-PHASETRANSFORMERLESS INVERTER. Abstract

[Sathya, 2(11): November, 2013] ISSN: Impact Factor: 1.852

A Control Scheme for an AC-DC Single-Stage Buck-Boost PFC Converter with Improved Output Ripple Reduction

Solar Inverter with Multi Stage Filter and Battery Buffering

Photovoltaic Controller with CCW Voltage Multiplier Applied To Transformerless High Step-Up DC DC Converter

Grid-Connected Boost-Half-Bridge Photovoltaic Micro inverter System Using Repetitive Current Control and Maximum Power Point Tracking

Study and Design of a Voltage Line Conditioner with Serial Compensation and Fed by Load Side

Power Management for Computer Systems. Prof. C Wang

Analysis of Solar PV Inverter based on PIC Microcontroller and Sinusoidal Pulse Width Modulation

Modeling of PV Interconnected Distribution System using Simulink

Reduced PWM Harmonic Distortion for a New Topology of Multilevel Inverters

Design and Simulation of New Efficient Bridgeless AC- DC CUK Rectifier for PFC Application

CHAPTER 6 INPUT VOLATGE REGULATION AND EXPERIMENTAL INVESTIGATION OF NON-LINEAR DYNAMICS IN PV SYSTEM

Modified Multilevel Inverter Topology for Driving a Single Phase Induction Motor

Bidirectional Ac/Dc Converter with Reduced Switching Losses using Feed Forward Control

ANALYSIS OF PWM STRATEGIES FOR Z-SOURCE CASCADED MULTILEVEL INVERTER FOR PHOTOVOLTAIC APPLICATIONS

Generalized Multilevel Current-Source PWM Inverter with No-Isolated Switching Devices

A Quadratic Buck Converter with Lossless Commutation

Realization of a Single-Phase Multilevel Inverter for Grid-Connected Photovoltaic System

Transcription:

Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137 Analysis of Utility Interactive Photovoltaic Generation System using a Single Power Static Inverter D. C. Martins*, R. Demonti, A. S. Andrade and O. H. Gonçalves Federal University of Santa Catarina Power Electronics Institute P.O. Box 5119-88.040-970 - Florianopolis - SC - Brazil. *Corresponding Author: Tel.: 55-48-331-9204; Fax: 55-48-234-5422; E-mail: denizar@inep.ufsc.br (Received : 31 January 2004 Accepted : 15 March 2004) Abstract: This paper presents the analysis of a static conversion system for treatment of the solar energy from photovoltaic panels. This system is interconnected with the commercial electric utility grid, contributing to the generation of the electrical energy. A current-fed push-pull converter, a buck converter, and a current inverter compose the power structure. The main features of the system are: simple control strategy, robustness and lower harmonic distortion of the current and natural isolation. The principle of operation, design procedure and experimental results are presented. Copyright 2004 by the Joint Graduate School of Energy and Environment 115

D. C. Martins, R. Demonti, A. S. Andrade and O. H. Gonçalves Keywords: Solar Energy, Photovoltaic Cells, Static Current Inverters, DC-DC Converter, High Frequency. Introduction Conventional energy sources, obtained from our environment, tend to be exhausted with relative rapidity due to their irrational utilization by humanity. This uncontrolled extraction of the natural energies, certainly will lead to instability of our ecological system. It is important to point out, that if it occurs the recuperation of this system will be practically impossible. As a consequence of this possibility, the apprehension for a diminution of the petroleum sources, natural gas and natural resources of coal has been intensified. For this reason, the effort to find new sources of energy, to permit reduction in the utilization of the natural resources of fuel, became a challenge for all scientific and technological areas in the world, and specially for the electrical engineering area. Within this context, solar energy appears as an important alternative to the increase of the energetic consumption of the planet, once that, the quantity of the energy from the sun, that arrives on the earth surface in a day, is ten times more than the total energy consumed for all the people of our planet during a year [1]. Through the photovoltaic effect the energy contained in the sunlight can be converted directly into electrical energy. 116 Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137

Anal. of Utility Interactive PV Generation Sys. Using a Single Power Static Inverter This method of energy conversion presents some advantages, such as: Simplicity; Does not require any moving mechanical part; Its modular characteristic offers large flexibility in the design and application of this kind of energy generator; Short time of installation and operation; High reliability, and low maintenance. Besides, photovoltaic solar systems represent a silent, safe, not polluting, and renewable source of electrical energy greatly appropriated for the integration in the urban area, reducing almost completely the energy transmission losses due to the proximity between the generation and the consumption. This kind of energy source, traditionally attractive in rural areas, begins now to be economically viable in utility grid connected applications. In that case, the photovoltaic panels are incorporated in the rooves or facades of commercial buildings and residential houses, delivering electric energy to the grid. Thus, the photovoltaic panels can operate as little power stations in parallel with the electric utility grid. Considering the application mentioned above, this paper describes a static conversion system for treatment of the solar energy from photovoltaic cells. This is a grid-connected system, contributing to the generation of the electrical energy. The complete system consists of three stages composed by of a Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137 117

D. C. Martins, R. Demonti, A. S. Andrade and O. H. Gonçalves current-fed push-pull converter connected to a buck converter, and in the output stage a current fed inverter. The control circuit strategy is very simple. It uses an average current control and a PWM modulation in the buck converter, for obtaining a rectified sinusoidal current. Much work in this application area has been proposed in the technical literature [2]-[4]. Some of them are very interesting and important; however, the isolation of the power structure is not natural or is accomplished with low frequency, and their control strategies are somewhat sophisticated. The power structure proposed in this paper is particularly robust and naturally isolated. Its main features are: simple control strategy and lower harmonic distortion of current. The current fed push-pull converter (first stage), the buck converter (second stage), and the current fed inverter (third stage), are very simple, well known and dominant structures in power electronics. By associating these converters and adopting an appropriate control strategy, we obtain the necessary requirements to connect the photovoltaic panels to the utility grid, keeping the quality of the energy and providing safe operation. In photovoltaic panels the electric energy is available in its terminals at the same instant that the light reaches it. But most of the electric equipment of standard use cannot directly be connected. This is because the panel generates direct current (DC) at low voltage (generally between 12 and 68 volts, depending on the technology used in the panel construction) and 118 Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137

Anal. of Utility Interactive PV Generation Sys. Using a Single Power Static Inverter the majority of the electrical equipment operates at alternating current (AC), at higher voltages (110 or 220 volts in the case of Brazil). For this reason the system operates by connecting the panels to the electric grid. As a result any grid-connected equipment can receive the energy provided by the sun. As this system does not use batteries to store energy, the generation depends exclusively on the solar energy availability. Although it seems a disadvantage, this option is economically advantageous. While the panel useful life is over 20 years, a battery operates for, in the maximum, 5 years and needs periodic maintenance. The association of these three converters provides the advantage to ally the galvanic isolation and voltage gain (pushpull) to the buck modulation simplicity and the inverter command and operation facility. The result is a simple system but with excellent results when applied to photovoltaic energy processing. Photovoltaic Panel Features The photovoltaic panels transform the sunlight energy directly to electrical energy. Figure 1 shows the typical output current-voltage characteristic of a photovoltaic panel, for two different levels of solar insolation, with a constant temperature. Curve 1 corresponds to the highest insolation level. For the lowest insolation level we have curve 2. For each solar Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137 119

D. C. Martins, R. Demonti, A. S. Andrade and O. H. Gonçalves irradiation level that reaches the photovoltaic panel, exists one point of maximum power (mpp). Despite the first stage operating in an open loop, studies are being made for the implementation of a mppt system (maximum power point tracker - system that searches the maximum power point) with the aim to improve the energy collected from the panels. I max1 I mpp1 I max2 I mpp2 I 1 2 mpp 2 mpp 1 V mpp2 V max1 V V mpp1 V max2 Figure 1. Typical output current-voltage characteristic of a photovoltaic panel, for two different levels of solar insolation. Principle of Operation In the engineering view, the interconnection between the solar panels and the grid must follow some prerequisites, so that the energy delivered to the grid will have high quality and the system will have to offer high reliability and safety. For that, the proposed power static conversion system must provide some important items, to produce high quality energy to the grid. These items are shown in Figure 2, and they 120 Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137

Anal. of Utility Interactive PV Generation Sys. Using a Single Power Static Inverter can be considered as the principal objectives of the proposed circuit. The proposed static conversion system for treatment of the solar energy is composed of three stages. The power structure diagram is presented in Figure 3. In the first stage we have the photovoltaic panels connected to the current-fed push-pull converter. The objectives of this stage consist of providing the isolation between the panels and the grid and increasing the voltage for the next stage. The output voltage of this stage is approximately 400V. This stage operates in high frequency (20kHz), with the aim to reduce the volume of the transformer. PV Array Increasing the panels voltage. Galvanic isolation between panels and mains. DC - AC inversion. Delivering current with low harmonic distortion. Avoiding the islanding effect. Utility grid Figure 2. Principal objectives of the static conversion system. Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137 121

D. C. Martins, R. Demonti, A. S. Andrade and O. H. Gonçalves HF transf. Vi L 2 Vo S 1 D 1 S 3 i L2 D 4 D 5 Vpv L 1 C 1 D 3 S 4 S 5 Lf Vm S 2 D 2 D 6 D 7 Cf Utility grid First stage Second stage S 6 S 7 PV array Third stage Figure 3. Proposed power structure diagram. Due to the current-fed characteristics, the switches S 1 and S 2 cannot be kept up open simultaneously. The drives control voltages of these switches are shown in Figure 4. The push-pull converter operates in continuous conduction mode with constant frequency and its duty cycle D is defined by (1), where Ts represents the switching period of the converter and ta is energy accumulation interval in L 1 inductor. D ta Ts = 2 (1) Since the average voltage in L 1 inductor is equal to zero during a complete switching period Ts (Ts = 2 ta + 2 td) it can be written: 1 ta td L = 1med Ts 0 0 V 2. Vpv. dt + ( Vpv Vrp) dt = 0 (2) where td is the interval of energy sent to the secondary side of the transformer. 122 Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137

Anal. of Utility Interactive PV Generation Sys. Using a Single Power Static Inverter Observing that Ts ta = D 2 (3) and Ts ta + td = 2 (see Figure 4) (4) we resolve (2) obtaining Vrp Vpv 1 = 1 D (5) where Vpv is the photovoltaic panels voltage and Vrp is the secondary side voltage transformer referred to the primary side. The equation (5) is the current fed push-pull converter output characteristic, operating in continuous conduction mode. We can observe that increasing the duty cycle, the converter voltage gain is also increased. Another important verification is that the Vrp e Vpv relation, according to (5), is not dependent to any parameter, only the duty cycle D. In other words the output voltage can be perfectly stabilized through D since Vrp Vi = (6) a where Vi is the push-pull output voltage and a is the push-pull transformer turns ratio. We can observe that for this stage a control circuit is not necessary simplifying its construction. Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137 123

D. C. Martins, R. Demonti, A. S. Andrade and O. H. Gonçalves S1 S2 t ta td Ts/2 ta td Ts t Figure 4. Drive control voltage of switches S 1 and S 2. The second stage is formed from the buck converter. In this stage the control circuit strategy is very simple, where a current feedback loop is imposed. It uses an average current control and a pulse width modulation (PWM), with 20 khz switching frequency, for attaining a output rectified current of 120 Hz. The reference sinusoidal voltage is obtained from the grid power supply, so that, in the absence of the grid voltage the photovoltaic system does not work, avoiding the islanding effect. The current modulation is based on the following equations: Vo ( θ ) = Vm = Vp sinθ (7) where Vo is the buck output voltage, Vm is the grid voltage, Vp is the grid peak voltage and θ is the grid voltage phase angle. Vo ( θ ) = Vi D( θ ) (8) D Vp Vi ( θ ) = sinθ Duty cycle of the buck converter. (9) 124 Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137

Anal. of Utility Interactive PV Generation Sys. Using a Single Power Static Inverter The current ripple in L 2 is given by: i L 2 = [ Vi Vp sinθ ] L2 fs D ( θ ) (10) il max 2 Vi = 4 L2 fs (11) where fs represents the switching frequency. Eq. (11) represents the biggest ripple current during a utility grid period. Thus, defining i L2 as the maximum ripple acceptable, it is possible to find the minimum L 2 inductor, for the appropriate operation of this stage. Figure 5 represents the buck output current, obtained via numerical simulation. 2A 1.5A 0 V(6) 9ms 10ms 11ms 12ms I(L)*1.5 Time Figure 5. Output current in the second stage. In the third stage we have a current fed inverter, which permits us to obtain a sinusoidal current at the same frequency of the utility grid (60 Hz), but with a phase angle of 180 o. This Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137 125

D. C. Martins, R. Demonti, A. S. Andrade and O. H. Gonçalves current is injected into the grid, transferring energy from the sun to the electric utility (220 V / 60 Hz). This inverter is composed of the S 4 - S 7 Mosfets, D 4 - D 7 diodes and by the high frequency harmonics filter Lf, Cf. The diodes D 4 - D 7 are connected in series with each Mosfet to avoid the grid short circuit, because in the current fed inverter the drive signals are superimposed. The operation of this stage occurs at low frequency, so the switches commutation losses are very small. Figure 6 shows the whole structure diagram, including the control circuit strategy employed in this work. Buck Converter Control As can be seen in Figure 6 the control circuit uses three sensors to obtain the desired effect. The first is the buck input voltage sensor with the aim to maintain the input voltage near 400V. In this loop there is a voltage compensator (V Reg.). The second is the sensor that observes the shape and the rms value of the output voltage (grid voltage sample). The third sensor monitors the buck output current in order to perform the average current control in this converter. In this loop we have the current compensator (I Reg.). The input voltage loop has the objective of maintaining constant the buck input voltage. As can be seen in Figure 6, this sensor is just a resistive divider that samples the voltage and 126 Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137

Anal. of Utility Interactive PV Generation Sys. Using a Single Power Static Inverter compares it to a reference voltage. The result is applied to V Reg. and sent to port A of the 3854 multiplicator [5]. The second feedback loop has the objective to define the output current shape as well as to measure the output rms voltage (grid voltage) value, and then, make the output power corrections in function of the variations in this voltage. S 3 L 2 S1 D 1 D4 D 5 D3 Vpv L 1 C 1 I Reg. S 4 S5 Lf - S2 D 2 + A.B C 2 A C B D6 S6 D7 S7 Cf Utility grid + - V Reg. RMS V ref. Figure 6. Power structure and its control strategy. In order to maintain the processing energy quality it is necessary that the output current keep its shape close to the grid voltage. In most cases this voltage is not a perfect sinusoid. A little transformer (second sensor) gives the waveform information of the grid voltage and rectifies it via of a full bridge diode. The rectified signal is sent to the B input directly and, after the RMS block, to the C input. The third feedback loop watches the buck output current in order to achieve the average current control. The feedback is negative. In this loop we have the third sensor that observes de Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137 127

D. C. Martins, R. Demonti, A. S. Andrade and O. H. Gonçalves current. This sensor is just a shunt resistor and the voltage that appears, when a current flows, is applied to the 3854 I Reg. Design Procedure and Example 1. Input data D = 0.7 duty cycle of the push-pull; f = 60Hz grid frequency; fs = 20kHz switching frequency; Po = 300W grid delivery power; Vpv = 14V push-pull input voltage; D = 0.7 duty cycle of the push-pull; Grid voltage: single-phase 220 V / 60 Hz. 2. Inductance L 1 The inductance L 1 can be obtained from the following equations: Vpv D L1 = = 114µ H ; 2 fs IL 1 where I = Po L 0. 1 1 Vpv 3. Transformer turns ratio (a). a = Vpv Vi 1 1 D = 0.12, where Vi = 400 V (buck input voltage); 128 Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137

Anal. of Utility Interactive PV Generation Sys. Using a Single Power Static Inverter 4. Capacitor C 1 The capacitor C 1 is given by: Po C Vi 1 = D 3.28µ F 2 fs Vi = ; where Vi = 1 % Vi 5. Inductance L 2 Vi L2 = = 12.96mH 4 fs i ; L 2max i L = 0.2 i L2, 2 max peak where Po il = 2 and Vp = 2 220. 2 peak Vp 6. Output filters (Cf, Lf). For the output filters the conventional design was used. So, the following values were obtained: Cf = 560nF ; Lf = 2.0mH Results A prototype rated at 300 W was built to evaluate the proposed circuit performance. The input data are given in the previous item. Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137 129

D. C. Martins, R. Demonti, A. S. Andrade and O. H. Gonçalves 1. Specifications The specifications of the components used in the experimental analysis are shown below: First stage S 1, S 2 MOSFET IRF250; D 1, D 2 MUR4100-4 A, 1000 V, ultra fast diode; L 1 120 µh inductor, 17 turns; Transformer a = 0.11 (turns ratio), primary 3+3 turns, secondary 27+27 turns; C 1 5 µf high frequency capacitor. Second stage S 3 MOSFET IRFP460; D 3 MUR450 4 A, 500 V, ultra fast diode; L 2 12mH inductor, 133 turns; Control CI UC3854 Unitrode. Third stage S 4 S 7 MOSFET IRFP460; D 4 D 7 Low frequency rectifier diode. Lf 2,0mH inductor, 84 turns; Cf 560nF, 400V, high frequency capacitor. Figure 7 presents the current and voltage in the Mosfet of the push-pull converter. We can observe a small high frequency oscillations on S 1 switch drain current. The same occurs in S 2. These oscillations are caused by the leakage inductance of the 130 Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137

Anal. of Utility Interactive PV Generation Sys. Using a Single Power Static Inverter push-pull transformer and reverse recovery phenomenon of the D 1 and D 2 diodes. However these oscillations do not affect significantly the push-pull operation. The voltage and the current in the Mosfet of the buck converter are shown in Figure 8. In the beginning of the buck Mosfet conduction, the current peak is superior to 2A. This peak is caused by the reverse recovery energy of the buck D 3 diode. It does not cause any damage to the Mosfet because its duration is very short and the total area involved is very small. The frequency of the voltage and current is 60Hz, so the Mosfets commutation losses are very small. The voltage waveform is produced by the control system in the second stage, which must be as close as possible to the voltage waveform. Figure 9 shows the voltage and current in the switch S 4. The drive signals of the current fed inverter are given in Figure 10. These signals are applied to the S 4 S 7 Mosfets. They are low frequency signals (60Hz). Figure. 11 presents the voltage and current transferred to the grid. Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137 131

D. C. Martins, R. Demonti, A. S. Andrade and O. H. Gonçalves current 0 voltage 0 Figure 7. Current and voltage in switch S 1. 20V/div; 10A/div; 10µs/div. voltage 0 current 0 Figure 8. Voltage and current in switch S 3. 100V/div; 1A/div; 10µs/div. 132 Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137

Anal. of Utility Interactive PV Generation Sys. Using a Single Power Static Inverter current voltage 0 Figure 9. Voltage and current in switch S 4 (third stage). 100 V/div; 0.5 A/div; 2 ms/div. A B 0 Figure 10. Drive signals of the current inverter switches Signal A S 4, S 7 Signal B S 5, S 6 5V/div; 2.5ms/div. Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137 133

D. C. Martins, R. Demonti, A. S. Andrade and O. H. Gonçalves voltage current 0 Figure 11. Voltage and current in the grid. 100 V/div; 1 A/div; 2 ms/div. We can observe that the waveform of the grid voltage and the current injected in to the utility grid are very similar, showing that the relative harmonic distortion between them is very low. There is a phase shift of 180 o between the voltage and current of the grid, indicating that the utility grid is receiving energy from the photovoltaic system. Comparing Figure 11 and Figure 9 we can observe that the high frequency component of the output current was eliminated by Lf and Cf high frequency filter. Figure 12 and Figure 13 show the total harmonic distortion (THD) of the voltage and current respectively. 134 Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137

Anal. of Utility Interactive PV Generation Sys. Using a Single Power Static Inverter 2.7% 2.5% 2.2% 1.9% 1.6% 1.4% 1.1% 0.8% 0.5% 0.3% 0.0% 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Harmonic magnitude as a % of the fundamental amplitude Figure 12. Voltage harmonic analysis of the grid. THD = 3.69%. 3.0% 2.7% 2.4% 2.1% 1.8% 1.5% 1.2% 0.9% 0.6% 0.3% 0.0% 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Harmonic magnitude as a % of the fundamental amplitude Figure 13. Current harmonic analysis of the grid. THD = 4.89%, phase = -175 o. It is important to observe that the THD of the commercial utility grid voltage is 3.69%. This happens due the non-linear loads connected to many points of the grid. So, the current waveform follows this distortion insuring a unity power factor. An efficiency of 91% was obtained at full load conditions. Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137 135

D. C. Martins, R. Demonti, A. S. Andrade and O. H. Gonçalves Conclusions This paper has presented the analysis of a static conversion system for treatment of solar energy from photovoltaic cells. This system is interconnected with the electric utility grid, contributing to the generation of commercial electrical energy. According to the results obtained we have a DC-AC static conversion system with the following features: It is particularly robust; It has a simple control strategy; It uses low cost technology; Does not present islanding problem in the voltage grid failure; Many systems can be associated in parallel; Simple installation; Lower harmonic distortion of current; Natural isolation. This system can be applied in residential or commercial buildings, for low or high power. Therefore, the authors believe that this technology can be very useful for some residential and/or industrial applications. References [1] Rüther, R. (1998) Use of the Photovoltaic Solar Energy. Seminar-Non-Conventional Energy Sources, 1, pp. 9-25. 136 Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137

Anal. of Utility Interactive PV Generation Sys. Using a Single Power Static Inverter [2] Calais, M. and Agelides, V.G. (1998) Multilevel Converters For Single-Phase Grid Connected Photovoltaic Systems, IEEE - ISIE 98, 1, pp. 224-229. [3] Chiang, S. J., Chang, K. T., and C. Y. Yen (1998) Residential Photovoltaic Energy Storage System, IEEE Trans. on Industrial Electronics, 45(3), pp. 754-759. [4] Kobayashi, H. and Takigawa, K. (1998) Islanding Prevention Method For Grid Interconnection of Multiple PV Systems, 2 nd World Conference on Photovoltaic Solar Energy Conversion, 2, pp. 837-842. [5] High Power Factor Preregulator (2002) Application Information UC 3854, Unitrode. Asian J. Energy Environ., Vol. 5, Issue 2, (2004), pp. 115-137 137