Setpoint & Ramp G

Similar documents
Mobile P-I Servoamplifier G

P-I Servoamplifier G

P-I Servoamplifier G

P-I Servoamplifier G A001

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

Digital amplifier for proportional valves PEM XD

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

RT-5005/5006/5007/5008

MDSD (Series 2X) Mobile Dual Solenoid Driver

Valve amplifier for proportional pressure valves

TECHNICAL DATASHEET #TD1400AX PWM Controlled Solenoid Driver (DIN rail mount) P/N: PWMC-DR-2A, PWMC-DR-1.2A

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Proportional amplifier type EV22K5

12 30 ripple included external fuse 3,0 A Current consumption A 1,0 2,6 depending from solenoid current. V ma. V ma. Output current A 1,0-1,6-2,6

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

Continental Hydraulics Installation Manual CEM-PA-A

Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:

Continental Hydraulics Installation Manual CEM-RA-A

Technical Documentation

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

Data Sheet. Agilent M9185A PXI Isolated D/A Converter. DISCOVER the Alternatives... Agilent MODULAR Products. 8/16-Channel 16-bit, ±16 V

Electronic amplifier type EV1D

MODEL: MRP6. Final Control Elements

SAX.. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

Accessories Power Amplifiers

Fuse, external A 6A, medium time lag. Power consumption W min 20 - max 60 (see paragraph 5.2) Output current A maximum 4.5 (see paragraph 5.

Don t Let EMI/EMC Compliance Certification Slow You Down TUTORIAL

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire

Proportional amplifier type EV1M3

Power supply CP-D 24/1.3

Process Control Calibration Made Easy with Agilent U1401A

Valve amplifier for proportional valves with electrical position feedback

Multi-voltage Multi-function. BE: Off-delay with control signal BE: Off-delay with control signal CE: On- and off-delay with control signal

Multi-voltage Multi-function. Wiring diagram (without control signal)

Modular timers A

Power supply CP-D 12/2.1

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Electro Controls. Input-Output Modules WattsIndustries.co.uk

Smart Power Relay E I...

Inclinometer Selection Guide

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

SCXI CURRENT INPUT,HIGH-VOLTAGE TERMINAL BLOCK

DENISON HYDRAULICS Multi-Function Proportional Valve Dual Driver ( Encapsulated )

To be automatically connected to the nearest North American Technical Sales Office:

Agilent AEDA-3300 Series Ultra Miniature, High Resolution Incremental Kit Encoders Data Sheet

Apitech Valve Drive Board

Isolation Addresses Common Sources of Differential Measurement Error

Temposonics. Magnetostrictive Linear Position Sensors. ER Analog Data Sheet

Mobile dual solenoid driver

83 SERIES. 83 Series - Modular timers A. Features

Analog Servo Drive 25A20DD

AMIS250P 250w Power Amplifier. Operating Manual. AMIS250P, 250 Watt Power Amplifier

APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS

PERMA Series Revision 2 Amplifiers

Amplifier / controller electronics

Room Temperature Controllers. for heating and cooling systems

83 Series - Modular timers 16 A. Features

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

Proportional Directional Control Valves Size 6

BNC-2121 Connector Accessory for 660X Devices

Process/Mini. English IMPORTANT NOTE. Installation and Operation Manual. General Purpose Light Curtain with 30 mm resolution

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options.

Proportional Directional Control Valves Size 6

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

RA / /6. Replaces: Table of contents RA /06.98

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Anacon Power & Controls

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

ELECTRONIC REGULATOR FOR OPEN LOOP

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

DENISON HYDRAULICS Proportional Pressure Control Valves

User's Manual PDO 2035

3400HD Series TECHNICAL MANUAL X-3400HD DTI-3400HD D-3400HD. 3400HD Unwind (using 3400ce Circuit Board) Montalvo. Unwind Tension Controllers

Analog Servo Drive 20A20

Technical Reference IMI C001 Parison Controller MOOG

POWER SYSTEM MODE STATUS

EMC filters. Mounting instructions. Date: January 2006

How to Choose Power Supplies

Analog amplifier RA. RE Edition: Replaces:

Power supply CP-E 24/2.5

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

DRC DIN Rail Conditioner. user manual

MODEL AT-10 ANALOG TRANSMITTER

CARREL-ELECTRADE LTD not just products... solutions!

LENORD. +BAUER... automates motion. MiniCoder GEL 2444K Speed and position sensor with metal housing and sin/cos output

Temposonics. Magnetostrictive Linear Position Sensors. ER Start / Stop Data Sheet

Proportional amplifier type EV1M3

MINI MCR-SL-UI-I-LP-NC

Power supply CP-E 24/20.0

TB-2705 PXI TERMINAL BLOCK FOR ESERIES

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke

Electromotoric actuators for stroke valves

DCM w Power Amplifier

IRT AT-Small. Technical Manual. quality IN MOTION. quality IN MOTION

Transcription:

M Setpoint & Ramp G-0 Application Notes Scope hese Application Notes are a guide to applying the G-0 Setpoint & Ramp. hey cover the following process: Determine the structure of your application. Select the G-0 for your application. Refer also to data sheet G-0. Use these Application Notes to determine your system configuration. Draw your wiring diagram. Install and commission your system. Aspects such as hydraulic design, Screw terminal receptacle actuator selection and performance estimation are not covered by these Application Notes. Moog Application Engineers can provide more detailed assistance, if required. Description he G-0 is a command signal generator that produces a sequence of ramped commands suitable for use as an input signal to a proportional valve for open loop control of a cylinder or motor. User supplied logic inputs to the G-0 select the four front panel set points, output polarity and ramp off. he four front panel set point potentiometers and an externally connected analog input signal are summed, passed through a polarity selector circuit and then a ramp circuit before being presented as an output signal to command the proportional valve. he ability to select any of the four set points and the feature of setting the ramp time, depending on output polarity and direction of change of the ramp, make the G-0 particularly versatile. An output deadband, that forces the output to zero when the ramp output is within ±% of zero, is very useful for open loop applications. Front panel test points enable measurement of the four internal set points and the four ramp rates. he ability to measure the potentiometer settings off-line, on the front panel, enables system set-up without the need to continuously cycle the process and eliminates the requirement for an additional test box. Once the values for a particular process are known, they can be used for all subsequent systems that are required to be set up. Installation. Placement A horizontal DIN rail, mounted on the vertical rear surface of an industrial steel enclosure, is the intended method of mounting. he rail release clip of the G-0 should face down, so the front panel and terminal identifications are readable. An important consideration for the placement of the module is electro magnetic interference (EMI) from other equipment in the enclosure. For instance, VF and AC servo drives can produce high levels of EMI. Always check the EMC compliance of other equipment before placing the G-0 close by.. Cooling It is important to ensure that equipment located below does not produce hot exhaust air that heats up the G-0.. Wiring SEPOIN & RAMP DIN rail release clip DIN rail Cover release tabs (x) he use of crimp boot lace ferrules is recommended for the screw terminals. Allow sufficient wire length so the position screw terminal connector can be withdrawn from its mating connector on the G-0. It is difficult to remove this connector by hand. here are two slots in the case, below the connector, that accept a flat blade screw driver, that when twisted in the slot, will release the connector. erminal identification is on the block diagram on page. Page of : C09 Rev C 0.0

Enclosure Grounded EMI cable gland Pots s Rotary Switch s and Pots Pots Slide Switch Cable 00mm Loop Radial shield termination Preferred wiring Wires Enclosure Cable gland Cable. EMC he G-0 emits radiation well below the level called for in its CE mark test. herefore, no special precautions are required for suppression of emissions. However, immunity from external interfering radiation is dependent on careful wiring techniques. he accepted method is to use shielded cables for all connections and to radially terminate the cable shields, in an appropriate grounded cable gland, at the point of entry into the industrial steel enclosure. If this is not possible, the use of a busbar mounting shield terminal block, such as Phoenix SK, is recommended. Exposed wires should be kept to a minimum length. Connect the shields at both ends of the cable to chassis ground. Power supply V nominal, to V ma, with maximum number of s on. If an unregulated supply is used the bottom of the ripple waveform is not to fall below V. It is recommended that the M0, 0mA (slow blow) fuse, supplied with the unit, be placed in series with the V input to protect the electronic circuit. here is a spare fuse in the cover of the fuse holder. Replacement fuses should be compliant with IEC - sheet. Detailed description Refer to the block-wiring diagram on page.. Set points 00mm Loop Alternative wiring Wires Chassis ground busbar Shield Shield terminal block Cable he four front panel set points and the analog input set point are summed to produce a single set point signal that is then processed by the polarity selector and ramp circuit. he four front panel set points are connected to the summing point only when selected by their corresponding select logic input. he maximum output is 0V, so if the sum of all selected set points and the analog set point is greater than 0V, the output will be limited to 0V. he front panel set point pots have an output of 0 to 0V. urning a pot clockwise increases the set point. he analog input has a range of ±0V. est points. Output polarity he output polarity is selected by the mode I and II logic screw terminal inputs. For an analog input Va and set point input, as shown in the graphs to the right, the three different output graphs are shown below. I: he positive set point pot signals are passed through to the ramp unchanged. Only positive signals from the analog input are passed through to the ramp. hus the output range is 0 to 0V. II: he positive set point pot signals are inverted, ie. A pot setting of.v produces.v on the input to the ramp circuit. he analog input signal is also inverted so the positive input produces a corresponding negative output. A negative analog input signal is blocked. I and II together: he positive set point pot signals and the analog input are summed and ramped unaltered. hus the output swings the full 0V to 0V. eg. If set point is the only selected set point and it is set to.0v and the analog input is.0v, the output will be.0v. Va Supply s When s I and II are selected together the mode select s illuminate only when the output signal is the corresponding polarity. When the output signal is within the deadband window of ±0.V both mode select s will be off. Va Va ( Va) Va Va analogue input set point Page of : C09 Rev C 0.0

. Ramps 0 he four ramp times, I (positive up), I (positive down), II (negative up) and II (negative down) are automatically selected by an internal circuit that senses the output polarity and the direction of the ramp, either increasing (up), or decreasing (down). Each has a ten to one range. he range switch selects either a 0. sec or 0sec range. he time is specified as the time taken for the ramp to change by 0V. urning the pots clockwise increases the time.. Zero he mode I and II zero pots are present on the output when the corresponding mode is illuminated. he I zero pot has an adjustment range of 0 to.v. he II zero pot has an adjustment range of 0 to.v. urning the pots clockwise increases the zero value. e s t point v o lt age (V) 9 example. Output deadband I only or II only: When the output of the ramp circuit is inside a window of ± 0.V, the ramp output is not present on the G-0 output. Only the selected zero pot is present on the output. When the ramp output exceeds ± 0.V, it is present on the G-0 output. At the start of a cycle, assuming the internal ramp output starts at 0V, the G-0 output will jump from the zero setting by 0.V when the internal ramp output exceeds 0.V. I and II together: Both the zero and ramp output are not present on the G-0 output when the ramp output is inside the ± 0.V window. hus the output is 0V until the internal ramp output exceeds 0.V. At this point the output jumps to 0.V plus the value of the appropriate zero pot setting.. est points he two test points, set point and ramp, enable the selected pot setting to be measured with reference to the 0V ( ) test point. he four position test select switch selects pairs of set points and ramps. e.g., position selects: set point one on the set point test point, at the bottom of the set point front panel outline and positive ramp up rate on the ramp test point at the bottom of the ramp front panel outline. Note: there is no logical connection between the signals in each pair. hey are arranged this way to simplify the internal electronics. he set point test point is scaled to have the same value as the set point. he ramp test point scaling is shown in the following graph. 9 0 (0.) () Ramp rate (V/S) Ramp test point scaling o determine the test point voltage for a particular ramp, calculate the ramp rate in volts per second and then determine the ramp test point voltage from the graph. Example: If a V ramp is required to have a time of seconds, the ramp rate is.v/s. From the graph determine that this requires a ramp test point voltage of.v.. Ramp off his function is selected by connecting to the ramp off screw terminal. When selected, there is no ramping of output signals. Changes in set point result in an immediate change in the output signal. Application example. Definition A typical application is to move a load forward with a hydraulic cylinder, then quickly retract the cylinder without the load. he eight phases of this motion profile are:. Initial acceleration extending.. Constant velocity extending.. De-accelerate to a creep speed as final position is near.. Creep to final extended position.. Acceleration retracting.. Constant high velocity retracting.. De-accelerate to a creep speed as final retracted position is near.. Creep to final retracted position. Valve Cylinder Load P Amplifier Hydraulic circuit Command from G-0 Page of : C09 Rev C 0.0

Extend A B C ime, S Final position, x = V V V 0 For this example x = 000, = S, = S, = S and = S 000 = V V V 0 V = 0 mm/s Set point is 0 mm/s. Retract o implement this example, limit switches are needed to detect the following: A. Retract position B. Near final position C. Final position D. Near retract position he four limit switches will select the appropriate setpoints for the profile: LS A selects extend velocity. LS B selects extend creep velocity. LS C selects retract velocity. LS D selects retract creep velocity. V mm/s V LS A B C D Motion profile 0 G-0 SP SP SP SP Limit switch set point selection For this example the required performance is Stroke 000mm Extend time 0S Retract time S Creep velocities 0mm/S Assume 0V full scale valve command produces 00mm/S cylinder velocity. Allow: S to accelerate S at constant velocity S to de-accelerate S at creep velocity. Set points Examining the extend profile: D Set point = 0 x 0V =.V 00 Set point is 0 mm/s Set point = 0 x 0V = 0.V. 00 However, the minimum output is 0.V. herefore set point should be 0.V, which corresponds to a creep velocity of 0 mm/s. Calculate set point in the same way as SP was calculated. is mm/s herefore set point =.V Set point is 0mm/S herefore set point = 0.V (0 mm/s). Ramps he first ramp,, increments.v in S. his is a ramp rate of.v/s. From the graph in. determine that this requires a ramp test point setting of 9.V. Set I ramp to 9.V. he second ramp,, has the same decrement as the first. So, set I ramp to 9.V. he third ramp,, decrements.v in S. his is a ramp rate of.v/s. From the graph in. determine that this requires a ramp test point voltage setting of.v. Set II ramp to.v. Set II ramp to.v also.. Polarity As the cylinder extends, mode I selection is required so the output command to the proportional valve is positive. As it retracts, mode II selection is required so the output is negative. Relay or PLC logic is required to select the appropriate mode, based on the sequencing of the limit switches. he circuit below shows a typical relay arrangement. Momentary Start Contact V RL RL B L.S. Extend RL relay logic B L.S. Extend RL A L.S. Retract 0 Extend profile ime, S Page of : C09 Rev C 0.0

. iming diagram he complete logic and analogue output timing diagram for this application example is shown below: Extend A Retract V Start Contact Closure SP SP SP SP RL RL B C D ime, S Ramp polarity and direction are automatically selected by a G-0 internal circuit. hus, no provision need be made for these.. Commissioning When commissioning the system, a three step sequence needs to be followed: Optimise the creep speed so the stop meets requirements. Adjust the extend and retract speeds, and, so the required times are achieved. Adjust the ramp times,, and for stable operation. select G-0 Specifications Analog input: Differential, 0 to ±0V 00k0hm input resistance Common mode, ±V max. Logic inputs: Analog output: Output deadband: Output polarity: On at 0V Off at V Max. V.mA @ V 0 to ±0V @ ±0mA max. Short circuit and over voltage protected ±% of full scale 0 to 0V, mode I 0 to 0V, mode II 0 to ±0V, mode I and II together Ramp times for 0. to S, to 0S 0V change: Front panel test Selected set point, 0 to 0V points: Selected ramp, 0.V/S or V/S 0V reference Front panel switches: Front panel indicators: est point select ramp time range select, 0. to S and to 0S Front panel Set points to trimpots: Ramp I Ramp I Ramp II Ramp II Zero I Zero II Supply: Set points to select amber I mode select, positive output amber II mode select, negative output amber Ramp off select amber Vs, internal supply green VLO, V supply below V red V nominal, to V ma @ V, max. no. of front panel s on Recommended M0, 0mA (slow blow) fuse supply protection: compliant with IEC - sheet Mounting: emperature: DIN rail to EN000 Housing IP0 erminal block IP0 0 to 0 C Dimensions: 90W x D x 0.H Weight: CE mark: C tick: gm EN000-- emission EN000-- immunity EN000-- emission Page of : C09 Rev C 0.0

Block-wiring diagram Set Point Pots Ramp Pots est Point Select Logic P P Set Point Ramp P 0V Range Zero () In Window Zero ( ) V -V Vs V LO 9 Fast Ramp Set Point Logic Select Inputs Analog Inputs Logic Select Inputs Ramp OFF SP SP SP SP 0 00K 00K Ramp OFF Up/Down Comparator Polarity Selection Internal ramp output Set Point Sum Logic Ramp Power Supply or Window Comparator Signal Output V Supply Input Vo Fuse 0mA M Internet Data For a detailed Data Sheet and the latest version of these Application Notes, please refer to the Moog website www.moog.com/dinmodules Industrial Controls Division. Moog Inc., East Aurora, NY 0-00. elephone: /-000. Fax: /-0. oll Free -00--MOOG. Moog GmbH. Germany. elephone: 00--0. Fax: 00--00. Moog Sarl. France. elephone: 0 0 0 00. Fax: 0 0 0 0. Moog Australia Pty. Ltd. elephone: 0 9 0. Fax: 0 9 0. Moog pursues a policy of continuous development and reserves the right to alter designs and specifications without prior notice. Information contained herein is for guidance only and does not form part of a contract. Australia: Melbourne, Sydney, Brisbane Austria: Vienna Brazil: S ao ~ Paulo Denmark: Birkerød England: ewkesbury Finland: Espoo France: Rungis Germany: Böblingen, Dusseldorf Hong Kong: Shatin India: Bangalore Ireland: Ringaskiddy Italy: Malnate (VA) Japan: Hiratsuka Korea: Kwangju-Kun Philippines: Baguio City Singapore: Singapore Sweden: Askim USA: East Aurora (NY) Page of : C09 Rev C 0.0