MPS Electrical Test Laboratory, Larsen & Toubro Limited, Mysore Campus, KIADB Industrial Area, Hebbal Hootagalli, Mysore, Karnataka

Similar documents
Calsytech, # 38 North Mada Street Nandambakkam, Chennai, Tamil Nadu. Discipline Electro-Technical Calibration Issue Date

Testing & Calibration Lab, 204, Diamond Industrial Estate No. 2, Ketki Pada Road, (Near Dahisar Toll Naka), Dahisar (East), Mumbai, Maharashtra

Technical Services Department, BHEL, Piplani, Bhopal, Madhya Pradesh. Discipline Electro Technical Calibration Issue Date

Electronics Test and Development Centre, STQC Directorate, Agriculture College Campus, Shivajinagar, Pune, Maharashtra

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Calibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 10

CALIBRATION CMC 2, 4 ( )

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION

Calitron Calibration Laboratory, U1: 207, Kohinoor Arcade, Tilak Chowk, Nigdi, Pune, Maharashtra

CERTIFICATE OF ACCREDITATION

Discipline Electro-Technical Calibration Issue Date Certificate Number C-0556 Valid Until Last Amended on - Page 1 of 7

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSL Z

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

April 10, 2018 VIA . Gore Laboratories, Inc. Jeff Buechler 10 Northern Blvd., Suite 5 Amherst, NH 03031

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION

SOLICITUD XXVI CONGRESO NACIONAL DE METROLOGIA

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z

Fluke 83V and 87V Digital Multimeters

President For the Accreditation Council Certificate Number Valid to January 31, 2010

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

For the National Voluntary Laboratory Accreditation Program

Annex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AMETEK CO., LTD. NAGOYA OFFICE. (Main Laboratory) Onna, Atsugi-shi, Kanagawa-ken, Japan

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & Z

Dimensional Up to 25 mm/ mm 2.0 µm 0 mm to 100 mm/ 0.01 mm 7.4 μm 100 mm to 300 mm/ 0.01 mm 10 μm

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ANSI-ASQ National Accreditation Board/ACLASS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2017 ANSI/NCSL Z (R2002)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

ACLASS Accreditation Services An ANSI-ASQ National Accreditation Board Company

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

SDM3045X Digital Multimeter. DataSheet

ACCREDITED LABORATORY

CERTIFICATE OF ACCREDITATION. ANSI/NCSL Z (R2002) and ANSI/NCSL Z (R2013)

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Current Clamp. 210

8588A Reference Multimeter

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2017 ANSI/NCSL Z (R2002)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z540.3

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z & ANSI/NCSL Z540.3

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Fluke 5820A Oscilloscope Calibrator Specifications

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Oscilloscope Calibration Options for 55XX Series Multi-Product Calibrators

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

RS Pro DIGITAL MULTI-METER SDM3055 SERIES

Calibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 19

Scope of Accreditation For The Calibration Solution Inc. Calibration

5520A. Multi-Product Calibrator. Extended Specifications 2005

5080A Multi-Product Calibrator

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

TR CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF ELECTRICAL DCLF METROLOGY. Approved By: Senior Manager: Mpho Phaloane Revised By:

TRACEABLE MEASUREMENT CAPABILITY

5520A. Multi-Product Calibrator. Extended Specifications

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Deutsche Akkreditierungsstelle GmbH. Scope of Accreditation D-K to DIN EN ISO/IEC 17025:2005

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators

Fluke 8845A/8846A Digital Multimeters Extended Specifications

Transcription:

Last Amended on - Page 1 of 6 SOURCE 1. DC VOLTAGE $ 1mV to 10 mv 0.13 % to 0.014% Using Multifunction Calibrator 10 mv to 1 V 0.014% to 0.0016% By Direct Method 1 v to 10 V 0.0016% to 0.0017% 10 V to 100 V 0.0017% to 0.0024% 100 V to 1000 V 0.0024% 2. AC VOLTAGE $ 45 Hz to 10 khz 5 mv to 100 mv 0.16% to 0.027% Using Multifunction Calibrator 100 mv to 1 V 0.027% to 0.025% By Direct Method 1 V to 10 V 0.025% 10 V to 100 V 0.025% to 0.031% 45 Hz to 1 khz 100 V to 1000 V 0.025% to 0.036% 10 khz to 100 khz 10 mv to 300 mv 0.54% to 0.11% 300 mv to 3 V 0.11% to 0.086% 3 V to 100 V 0.086% to 0.29% 3. DC CURRENT $ 10 µa to 100 µa 0.25 % to 0.040% Using Multifunction Calibrator 100 µa to 1 ma 0.040 % to 0.017% By Direct Method 1 ma to 100 ma 0.017% to 0.015% 100 ma to 1 A 0.015 %to 0.028% 1 A to 10 A 0.028% to 0.064% 10 A to 20 A 0.064% to 0.35% 20 A to 900 A 1.42% to 0.66% With Current Coil

Last Amended on - Page 2 of 6 4. AC CURRENT $ 45 Hz to 1 khz Using Multifunction Calibrator 30 µa to 100 µa 0.56% to 0.26% By Direct Method 100 µa to 3 ma 0.26% to 0.12% 3 ma to 100 ma 0.12 % to 0.078% 100 ma t0 1 A 0.078% to 0.074% 1 A to 10 A 0.074% to 0.14% 10 A to 20 A 014 % to 0.35 % 1 khz to 5 khz 10 ma to 100 ma 0.12% to 0.18% 100 ma to 1A 0.18% to 0.81% 1 A to 10 A 0.81% to 3.50% 50 Hz With Current Coil 20 A to 750 A 0.88% to 0.80% 5. RESISTANCE $ 1Ω to 10 Ω 0.13% to 0.016% Using Multifunction Calibrator 10 Ω to 100 Ω 0.016% to 0.0050% By Direct Method 100 Ω to 100 k Ω 0.0050% to 0.0036% 100 k Ω to 1 M Ω 0.0036% to 0.0042% 1 M Ω to 10 M Ω 0.0042% to 0.016% 10 M Ω to 100 M Ω 0.016% to 0.062% 100 M Ω to 1 G Ω 0.062% to 1.79% 6. CAPACITANCE $ 1 khz Using Multifunction Calibrator 350 pf to 10 nf 3.88% to 0.40% By Direct Method 10 nf to 300 nf 0.40% 100 Hz 1 µf to 100 µf 0.41% to 0.67%

Last Amended on - Page 3 of 6 7. FREQUENCY $ 1 Hz to 100 khz 0.00087 % to 0.00029 % Using Multifunction Calibrator 100 khz to 100 MHz 0.00029 % to 0.0031 % By Direct Method 100 MHz to 250 MHz 0.0031% 8. OSCILLOSCOPE $ 5 mv to 33 V 2.60% to 0.29% Using Multifunction Calibrator DEFLECTION By Direct Method COEFFICIENT/ DC AMPLITUDE DEFLECTION 1 khz Using Multifunction Calibrator COEFFICIENT / 5 mv to 50 V 2.60% to 0.29% By Direct Method AC AMPLITUDE TIME MARKER 5 ns to 5 s 0.0031% to 0.12% Using Multifunction Calibrator By Direct Method LEVELED DC to 250 MHz 4.89% Using Multifunction Calibrator SINE WAVE By Direct Method (Band Width) MEASURE 1. DC VOLTAGE $ 5 mv to 100 mv 0.086% to 0.0084% Using Digital Multimeter 6½ 100mV to 10 V 0.0084% to 0.0034% By Direct Method 10 V to 1000 V 0.0034% to 0.0060% 2. AC VOLTAGE $ 10 Hz to 20 khz Using Fluke 8846 A 6½ DMM 5 mv to 100 mv 1.01% to 0.12% By Direct Method 100 mv to 30 V 0.12% to 0.19% 45 Hz to 1 khz 30 V to 1000 V 0.19% to 0.097%

Last Amended on - Page 4 of 6 50 Hz 35 V to 240 V 0.0064% to 0.0044% Using COM 3003 240 V to 320 V 0.0044% to 0.0068% 50 Hz Using Digital Multimeter 1 kv to 5 kv 1.31% to 0.32% by Direct Method 3. DC CURRENT $ 100 µa to 100 ma 0.088% to 0.064% Using Digital Multimeter 6½ 100 ma to 1 A 0.064% to 0.082% DMM by Direct Method 1 A to 10 A 0.082% to 0.20% 4. AC CURRENT $ 45 Hz to 1 khz Using 6½ DMM 100 µa to 1 ma 0.25% to 0.16% By Direct Method 1 ma to 1 A 0.16% to 0.17% 1 A to 10 A 0.18% to 0.28% 50 Hz 5 ma to 50 ma 0.035% to 0.0060% Using COM 3003 50 ma to 120 A 0.0060% to 0.0068% 5. RESISTANCE $ 1Ω to 10 Ω 0.36% to 0.046% Using Fluke 6½ DMM 10 Ω to 100 Ω 0.046% to 0.016% By Direct Method 100 Ω to 100 k 0.016% to 0.013% 100 k Ω to 1 MΩ 0.013% 1 MΩ to 10 MΩ 0.013% to 0.047% 10 MΩ to 100 MΩ 0.047% to 0.94% 100 MΩ to 1 GΩ 0.94% to 2.32% 6. FREQUENCY $ 1 Hz to 10 Hz 0.0010% to 0.00050% Using 10 Hz to 100 Hz 0.00050% to 0.000010% Frequency Counter 100 Hz to 300 MHz 0.000010% to 0.0000012% By Direct Method 300 MHz to 350 MHz 0.0000012% to 0.0000029%

Last Amended on - Page 5 of 6 60 V to 240 V Using DMM 45 Hz to 100 Hz By Direct Method 7. AC POWER $ 45 Hz to 65 Hz Using COM 3003 (Cos Ө = ± 0.25 to 1) 40 V to 320 V 0.027% to 0.013% Three & Single Calibration 1Φ ( Active) 10 ma to 120 A 0.2 W to 38.4 kw 0.6 W to 115.24 kw 10 ma to 120 A Three & Single Calibration (Sin Ө = ± 0.25 to 1) 40 V to 320 V 0.027% to 0.013% Using COM 3003 1Φ ( Active) 10 ma to 120 A Three & Single Calibration 0.2 VAr to 38.4 kvar 0.6 VAr to 115.24kVAr 10 ma to 120 A Three & Single Calibration 8. AC ENERGY $ 45 Hz to 65 Hz Using COM 3003 (Cos Ө = ± 0.25 to 1) 40 V to 320 V 0.027% to 0.013% Three & Single Calibration 1Φ ( Active) 10 ma to 120 A 0.2 Wh to 38.4 kwh 0.6 Wh to 115.2 kwh 10 ma to 120 A Three & Single Calibration (Sin Ө = ± 0.25 to 1) 40 V to 320 V 0.027% to 0.013% Using COM 3003 1Φ ( Active) 10 ma to 120 A Three & Single Calibration 0.2 VArh to 38.4 kvar

Last Amended on - Page 6 of 6 0.6 VArh to 115.2kVAr 10 ma to 120 A Three & Single Calibration 9. IMMUNITY/IMPULSE GENERATORS $ Voltage ±125 V to± 500V 3.30% to 2.04 % Using Tektronixs / TDS 3054 B Amplitude ±500 V to ±12 kv 2.04 % to 3.56 % DPO, Tektronix/P5100/ P6015A HV Probes / KW 50 / Pulse Rise Time 5 ns to 75 ns 3.19 % to 2.06 % KW1000 EFT Attenuators by Direct Method Pulse Width 50 ns 2.34 % Front Time 1.2 µs 2.16% Time to Half Value 50 µs 2.79% Burst Duration 0.8 ms to 15 ms 2.43% to 2.38% Burst Period 300 ms 2.33% Repetition Frequency/Rate 40 Hz to 400 Hz 2.04 % 5 khz to 100 khz 2.32 % to 2.38% Oscillation frequency 100 khz to 1 MHz 2.04 % * Measurement Capability is expressed as an uncertainty ( ) at a confidence probability of 95% $ Only in Permanent Laboratory