What Are We Protecting? Over-Voltage Protection for CP Systems. Personnel (primary) Equipment (secondary)

Similar documents
Instant-Off (I-O) Measurements on Decoupled Systems

AC Voltage- Pipeline Safety and Corrosion MEA 2015

60Hz Ratings. Typical Applications. Features & Characteristics. Ratings

PCR Polarization Cell Replacement. The Polarization Cell Replacement (PCR) Technical Literature COMMON APPLICATIONS

Standard Recommended Practice. Mitigation of Alternating Current and Lightning Effects on Metallic Structures and Corrosion Control Systems

ENGINEERING REPORT PHASES I & II MITIGATOR PERFORMANCE TESTS

The Isolator/Surge Protector (ISP)

The Isolator/Surge Protector (ISP) Technical Literature

The Isolator/Surge Protector (ISP)

Field Instruction. Induced voltages can occur in overhead lines, underground cables, or in switchyards.

Overview of Grounding for Industrial and Commercial Power Systems Presented By Robert Schuerger, P.E.

Upgrading Your Electrical Distribution System To Resistance Grounding

ACCURATE SIMULATION OF AC INTERFERENCE CAUSED BY ELECTRICAL POWER LINES: A PARAMETRIC ANALYSIS

CONTINUING EDUC ATION

The Variable Threshold Neutral Isolator (VTNI)

Equipment Rack Grounding. Technical Note

Outdoor Installation 2: Lightning Protection and Grounding

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

EPG. by Chris C. Kleronomos

RAPTOR Step and Touch Function

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

Grounding for Power Quality

The Lightning Event. White Paper

Amveco Toroidal Solutions. Acme Electric s class leading toroidal magnetics is the perfect solution for the most challenging applications.

Isolating Spark Gaps. Isolating spark gaps at an additional earth ring conductor. Isolating spark gaps for Ex zones

Monitoring DC Decoupling Devices at Isolation Flanges for Compliance and Pipeline Integrity

INTRINSIC SAFETY BASIC PRINCIPLES

PIPELINE CORROSION RISKS ASSOCIATED WITH AC VOLTAGES

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

Preface...x Chapter 1 Electrical Fundamentals

A DUMMIES GUIDE TO GROUND FAULT PROTECTION

INTEGRATED METHOD IN ELECTROMAGNETIC INTERFERENCE STUDIES

High Voltage Pylon Earth Measurements

Earthing of Electrical Devices and Safety

2 Grounding of power supply system neutral

Static Stray DC Current Interference Testing

Practical Lightning Mitigation

Single Earthed Neutral and Multi Earthed Neutral. Single Earthed Neutral and Multi Earthed Neutral: Multi Grounded Neutral System (MEN):

1 Comparison of Approaches (SESTLC, ROW & HIFREQ) for AC Interference Study

National Radio Astronomy Observatory Socorro, NM EVLA Memorandum 41 Lightning Protection for Fiber Optic Cable. T. Baldwin June 05, 2002

Section 6: System Grounding Bill Brown, P.E., Square D Engineering Services

LONGITUDINAL INDUCTION VOLTAGE MEASUREMENT ON COMMUNICATION CABLES RUNNING PARALLEL TO OVERHEAD LINES

Grounding and Bonding

TRANSFORMER OPERATION

Ferrite Transformer Testing

AC Interference Corrosion, Corrosive Soil, Design Issues, Zinc Ribbon and Corrosion Mitigation

Industrial and Commercial Power Systems Topic 7 EARTHING

Signal and Noise Measurement Techniques Using Magnetic Field Probes

Grounding System Theory and Practice

3Ø Short-Circuit Calculations

Aerovox Corp. Type RBPS IGBT Snubber Capacitor Modules Direct Mount and Board Level IGBT Capacitor Modules RoHS Compliant Highlights

A New Technology. for Measuring Overhead Line and Cable Impedance Values and the Ground Impedance of Large Substations. Feature

ELEC Transmission i and

Surge Protection and Grounding Issues

Understanding Noise Cut Transformers

Importance of Grounding in Power System. Presented by Mr. H Jayakumar Ex- Joint Director CPRI

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

MODERN COMPUTATIONAL METHODS FOR THE DESIGN AND ANALYSIS OF POWER SYSTEM GROUNDING

Need for grounding Codes and Standards for grounding Wind Turbine Generator grounding design Foundation + Horizontal Electrode grounding design

A Case Study on Selection and Application of Lightning Arrester and Designing its Suitable Grounding Grid

PRACTICAL PROBLEMS WITH SUBSTATION EARTHING

Electric Power Systems Research

Examples of Design for Cathodic Protection Systems

Electricity Supply to Africa and Developing Economies. Challenges and opportunities. Technology solutions and innovations for developing economies

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01

7P Series - Surge Protection Device (SPD) Features 7P P P

To Float or Not to Float? Analysis of a floating vs. grounded output Associated Power Technologies

Copper Sheathed Cable Sheath Currents

Tech Talk (12) Down to Earth: A Discussion of the General Requirements for the Earthing of Control and Instrumentation Systems

PMT/UMT(275) Power Gap Description and Use Application Note

High Voltage Pylon earth Measurements. Tycom (Pty) Ltd Frank Barnes Comtest (Pty) Ltd Presented by Gavin van Rooy

VSD cables in. Working with. industrial & automation applications

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01

Topic 6 Quiz, February 2017 Impedance and Fault Current Calculations For Radial Systems TLC ONLY!!!!! DUE DATE FOR TLC- February 14, 2017

Compatibility of HVDC Transmission Lines with Signal Systems. Rod Perala, PhD Jennifer Kitaygorsky, PhD

EIS Measurement of a Very Low Impedance Lithium Ion Battery

SINGLE-PHASE VSV SWITCH

Investigation on the Performance of Different Lightning Protection System Designs

FISCHER CUSTOM COMMUNICATIONS, INC.

EPR Safety Mat Modelling & Field Testing Summary Report

ECDA to assess possibility of AC Corrosion. Mark Yunovich Honeywell Corrosion Solutions January 27 th, 2009

TRANSFORMERS INTRODUCTION

Session Four: Practical Insulation Co-ordination for Lightning Induced Overvoltages

Megohmmeter Model 1060

ELECTRICAL SAFETY TESTERS. Wings for Your Projects. APPLICATION NOTE

Continued from Part 1 Rules 1 25.

Analysis of the Electromagnetic Interferences between Overhead Power Lines and Buried Pipelines

OVERCOMING THE NEW THREAT TO PIPELINE INTEGRITY - AC CORROSION ASSESSMENT AND ITS MITIGATION -

Trade of Electrician. Introduction to AC

Wisconsin Contractors Institute Continuing Education

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

Chapter 11. Alternating Current

Short Circuit Current Calculations

APPLICATION OF LONG FLASHOVER ARRESTERS FOR IMPROVEMENT OF LIGHTNING PROTECTION AND OPERATING VOLTAGE RELIABILITY OF DISTRIBUTION LINES

Lightning Strikes. Presented to the Greater Norwalk Amateur Radio Corporation Inc. February 8, 2017 Steven M. Simons W1SMS

Grounding Essentials for the Shack

Table of Contents. Table of Figures. Table of Tables

SINGLE-PHASE VSV SWITCH

Parameters Affecting the Back Flashover across the Overhead Transmission Line Insulator Caused by Lightning

2000 Mathematics Subject Classification: 68Uxx/Subject Classification for Computer Science. 281, 242.2

Transcription:

What Are We Protecting? Personnel (primary) Equipment (secondary) Over-Voltage Protection for CP Systems

Personnel Protection: Touch Potential Personnel Protection: Step Potential

Equipment Protection Equipment Protection Example Punctured coatings Breakdown of insulation Fuel ignition/explosion Equipment failure

From What Voltage Sources? Over-Voltage Protection Goal Lightning (most difficult) AC power system faults* Induced voltage* *If induced voltage is present, AC faults are then also of concern Minimize voltage difference between points of concern: Worker contact points Across insulated joints From exposed pipelines to ground Across electrical equipment insulation

Over-Voltage Protection Goal Lightning Protection: Primary Considerations Different considerations apply for: Lightning AC faults Induced voltage Clamping voltage (C CV ) of protective device Voltage drop in connecting leads Inductive voltage (V IV ) Resistive voltage (V RV )

Lightning Protection Voltage Level (V PV ) Voltage Across Flange Insulation Due to Lightning V PV = V CV + V RV-lead + V IV-lead V CV easily controlled by design V RV-lead easily controlled by design V IV-lead difficult to control

Protective Device Clamping Voltage (V CV ) <100V to 1000V typical values Resistive Voltage Drop (V RV ) Easily made negligible relative to inductive voltage component Example: Assume #4 copper conductor with R= 0.25milliohms/Ft. Assume a 50kA peak lightning current. Then IR = 12.5 V/Ft. or 41V/meter

Inductive Voltage Drop (V IV ) Lightning Characteristics V IV = L (di/dt) where: L = lead inductance, µh/ft di/dt = rate of change of current, amps/microsecond Slope = di/dt (Rate of rise, Amps/µsec) 1.0 Crest Amperes 1/2 Crest Value 0 8 20 Time in microseconds Lightning has very high di/dt (rate of change of current)

Typical (V IV ) Parameters Lead inductance (L): 0.2µH/ft. typical Typical di/dt 15,000A/µ-sec indirect lightning strike 150,000A/µ-sec direct lightning strike Protective Voltage (V PV ) Example Assume: V CV = 300V Lead inductance = 0.2µF/ft. Total lead length = 1 ft. total di/dt = 15,000A/µ-sec Then V PV = 300 + 0.2x15,000 = 3,300V

Voltage Across Flange Insulation Due to Lightning For Best Protection Keep leads as short as possible Use multiple leads when feasible Use mounting kits furnished by mfg (minimizes inductance)

Insulated Joint Protection Insulated Joint Protection

Insulated Joint Protection Insulated Joint Protection

Similar Considerations Pertain To Personnel Protection From Lightning When using gradient control mats to limit touch and step potentials Mat inductance greatly affects both step and touch potentials Inductance of lead connections to the mat affect touch potentials Common Gradient Control Mat Designs Single conductor mat (spiral or zig-zag) Multi-conductor mat (grid type)

Single Conductor Spiral Mat Multi-Conductor Grid Mat Current Flow I (Radial Current Flow) Pipe O.D. = 12 Turn Spacing = 12 Mat I.D. = 12 Mat O.D. = 132 Pipe O.D. = 12 Mat I.D. = 12 Mat O.D. = 132

Spiral Mat: Grid Mat 5 turns, 1 ft. turn separation, I.D. = 12, O.D. = 132 L = 0.2µF/ft. L (r=6 to 18 ) = 3.2 x 10-6 H L (r=18 to 30 ) = 10.27 x 10-6 H L increases with radial distance 2 x 2 grid, I.D. = 12, O.D. = 132 L = 21.74 x 10-9 H/Square L (r= 6 to 18 ) = 3.8 x 10-9 H L (r= 18 to 30 ) = x 1.77 x 10-9 H Decreases with radial distance

Spiral Mat Ldi/dt Values Grid Mat Ldi/dt Values L (r=6 to 18 ) = 3.2 x 10-6 H L(di/dt) = 3.2 x 10-6 x 1.5 x 10 10 = 48kV Or L(di/dt) = 3.2 x 10-6 x 1.5 x 10 11 = 480kV L(di/dt) increases with with each 12 radial increment (each turn) L (r=6 to 18 ) = 3.8x10-9 H L(di/dt) = 3.8x10-9 x 1.5 x 10 10 = 57 V Or L(di/dt) = 3.8x10-9 x 1.5 x 10 11 = 570 V L(di/dt) decreases with each 12 radial increment

Spiral vs Grid Mat Comparison Touch and Step Potential Ratios Spiral/Grid Ratio (r = 6 to r = 18 ) 48kV/57V = 842:1 Increases with each 12 increment Spiral Mat Touch & Step Potentials (For di/dt = 1.5x10 10 A/µ-sec) Radial Distance (In.) Touch Potential (kv) Step Potential (kv/ft) Step Potential (kv/m) 6 0 0 0 18 48.04 48.04 157.6 30 154 105.96 347.5 42 310.5 156.3 512.7 54 506.7 196.3 643.9 66 725.9 219.9 718.9 For di/dt = 1.5x10 11, multiply all potentials by 10 Note: Potentials in kv

Grid Mat Touch & Step Potentials (For di/dt = 1.5x10 10 A/µ-sec) Ratio of Step & Potential Ratios Spiral vs Grid Mat Radial Distance (In.) Touch Potential (V) Step Potential (V/ft) Step Potential (V/m) 6 0 0 0 18 57 57 187 30 83.4 26.4 86.6 42 101 17.6 57.7 54 114.5 13.5 44.3 66 124.3 9.8 35.2 For di/dt = 1.5x10 11, multiply all potentials by 10 Note: Potentials In Volts Radial Distance (In.) Spiral/Grid Ratio 6 0 18 843 30 1847 42 3074 54 4425 66 5840 For di/dt = 1.5x10 11, ratios remain unchanged

Over-Voltage Protection From Lightning-Key Factors Inductance of current flow path Lead inductance/length When over-voltage protection from lightning is provided, over-voltage protection from AC faults is also provided Over-Voltage Protection Products Desired characteristics: Lowest clamping voltage feasible Designed for installation with minimal lead inductance & minimal lead length Fail-safe (fail shorted not open ) Provide over-voltage protection for both lightning and AC faults

AC Voltage Sources AC Voltage on Pipelines Capacitive, conductive, and magnetic coupling to an adjacent power line Lightning strike to adjacent power line or near a pipeline

AC Voltage Sources Capacitive Coupling A potential shock hazard Only of concern during pipeline construction when pipeline is above ground Ground pipeline to eliminate

Conductive Coupling Conductive Coupling (Used with permission of Correng) A potential shock hazard Of concern when: An AC fault occurs on adjacent electric power line and Pipeline is located close to electric power line tower May damage pipe wall and coating Maximize distance from power line towers

Magnetic Coupling Primary source of what is normally considered induced voltage A potential shock hazard Readily mitigated May also cause AC corrosion of pipeline Lightning Strike To Power Line Adjacent to A Pipeline A potential shock hazard Due to significant rise in earth potential transferred to adjacent pipeline Can readily over-stress (damage) pipeline coatings, joint insulation, etc. More difficult to mitigate

Magnetically Induced Voltage Magnetically Induced Voltage (Used with permission of Correng) Typical voltages range from a few volts to about 100 volts Voltages over 15V should be mitigated (NACE) May be necessary to mitigate below 15V to prevent AC corrosion

Magnetically Induced Voltage Key Factors Proximity to power lines Power line loading (current magnitude) Quality of pipeline coating Why Mitigate Induced Voltage? To protect personnel from electric shock To prevent damage to pipelines, coatings, and other pipeline equipment To prevent AC corrosion

Mitigation Techniques Spot Mitigation Spot mitigation Continuous mitigation Both approaches require a grounding system Depending on grounding system material: May be direct connected to pipeline or Decoupled from pipeline Used to reduce pipeline potentials at accessible locations (e.g. valve sites) Less costly than continuous mitigation Grounding system may consist of: Magnesium or zinc, direct bonded or decoupled Pipeline casings, copper, etc., must be decoupled Gradient control mats, direct bonded or decoupled depending on material

Continuous Mitigation Used to reduce pipeline potentials at all locations Limits voltage stress on coatings to safe levels (primary advantage) Requires a continuous grounding system (typically zinc ribbon or copper) Design requires specialized software Considerations: Direct Bonded vs Decoupled Grounding System Ability to take instant-off pipeline potential readings Decoupled-may required a delayed-off measurement or use of coupons Ability to achieve desired CP Stray DC current Mitigation costs

Mitigating Induced AC Using A Decoupler A commonly asked question: How can a decoupler with a 2V or 3V blocking voltage be used with 30Vac on a pipeline? Example: Pipeline with Induced AC Voltage Open-circuit induced AC on a pipeline = 30 volts Short-circuit current = 10 amperes (to mitigation grounding system) Given the above, then the circuit impedance is 30V/10A =or 3 Ohms What is the effect of connecting the pipeline to the grounding system through a decoupler?

Example: Pipeline with Induced AC Voltage - continued Typical decoupler ac impedance Xc: Xc = 0.01 ohms Because the device impedance is insignificant compared to the 3 Ohm circuit impedance, the current to ground remains 10 amps V(pipeline-to-grounding system) = I. Xc I. Xc = 10. 0.01 = 0.1 volts Result: Induced AC reduced from 30V to 0.1V with respect to grounding system (well below decoupler blocking level). Will be higher to adjacent earth. Mitigating Induced AC Example applies to either spot or continuous mitigation A decoupler provides the greatest flexibility with any mitigation method but May required an alternate procedure* to determine true polarized pipe potentials * A delayed off measurement or use of coupons may be required

Mitigating Induced AC Voltage Mitigating Induced AC Voltage

Hazardous Locations Class I, Div. 1 or Class I, Div. 2 Hazardous Locations Many applications described are in Hazardous Locations as defined by NEC Articles 500-505 Pipeline Safety Regulations incorporate National Electric Code By Reference

Pipeline Safety Regulations Section 192.467 Pipeline Safety Regulations Section 192.467, continued (e) An insulating device [insulated joint] may not be installed where combustible atmosphere is anticipated unless precautions are taken to prevent arcing. (f) Where a pipeline is located in close proximity to electric transmission tower footings... it must be provided with protection against damage due to fault current or lightning, and protective measures must be taken at insulating devices [insulated joints].

Hazardous Locations The products [not just enclosure] must be certified for the application and installation location Codes: NEC Articles 250.2, 250(4)(A)(5), 250-6(E) and 500-505 Pipeline Safety Regulations 192.467 Summary Certified decouplers are available for: Over-voltage protection Voltage mitigation For grounding electrical equipment in compliance with electric codes In ordinary and hazardous locations

Conclusion Products are available or can be tailored for most applications Guidelines available for product application and model/rating selection Henry Tachick Dairyland Electrical Industries P.O. Box 187 Stoughton, WI 53589 Phone: 608-877-9900 Fax: 608-877-9920 Email: contact@dairyland.com Internet: www.dairyland.com