AT-SL-DDR & AT-SL-DDR-SA

Similar documents
AT-SL-DDR & AT-SL-DDR-SA

AT-SL-ADR & AT-SL-ADR/SA

EBDSPIR-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

EBDHS-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

EBDHS-MB-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

RF ceiling microwave presence detector DALI / DSI

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

EBDSM-PRM Product Guide

Fibaro System Modules

FL ballasts Electronic dimming. PCA T8 ECO lp Y II, W ECO T8

Wireless multizone receiver RDE-MZ6

Data sheet. Function description. Benefits

Plug power input. Socket power output

LED Driver Compact dimming

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

LCC1653, LCC1656, LRI1653 Datasheet ActiLume DALI System

ZoneLite setup remote handset. Daylight Linking & Daylight Dependency control

LED Driver Compact dimming

luxcontrol lighting control system DALI sensors basicdim RCL DBC Control module for combination with ambient light sensor, switch and presence sensor

PCA ECO lp Y, W T8 fluorescent lamps

Wireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space

LED Driver Compact dimming

PHASED OUT. LED Driver Compact dimming. Driver LCAI 20W 350mA 900mA ECO SR ECO series

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO C ECO series

LLC1681, LRI1655 Datasheet ActiLume Wireless 1-10V system

Installing the FSP-211 Sensor in Light Fixture

Product and Applications Description

FL ballasts Electronic dimming. PCA T8 EXCEL one4all lp Y II, W EXCEL T8

Artistic Licence. Rail-DMX-DALI. User Guide. Version 1-7. Rail-DMX-DALI User Guide

RoHS. Electronic ballasts for dimming to 1 % Linear lamps T5, 16 mm high efficiency, high output

WIRELESS DIMMER FOR HEATING

Radio motion detector comfort 1.1 m/2.2 m quicklink Order number

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 350mA 550mA ECO lp ECO series

FL ballasts Electronic dimming. PCA T5 ECO lp Y, 3x14/24 W and 4x14/24 W ECO T5

LED Driver Linear / area dimming. Udriver LCAI 20W 350mA 550mA ECO lp ECO series

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO SR ECO series

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL series. PCA TCL EXCEL one4all lp Y, 55 W Compact and T5c fluorescent lamps

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 150mA 400mA ECO lp ECO series

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 100W 350mA 900mA ECO INDUSTRY sl ECO series

High/Low Bay Passive Infrared Occupancy Sensor

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

LED Driver Compact dimming

Smart Dupline Wireless dimmer with energy reading Type SHJWD200WExxx

Operating instructions Flat-Type Wall-Mounted Radio Control

FL ballasts Electronic dimming. PCA T8 ECO lp Y, 3x18 W and 4x18 W ECO T8

TABLE OF CONTENT A. Installation and Mounting Installation 3 2. Mounting Receiver Addressing... 5 B. Key Interface. 7 C.

SeriesTWO RGB Fluorescent Fixtures. Installation and Instruction Manual

FL ballasts Electronic dimming. PCA T5 EXCITE lp Y, 3 and 4x14/24 W EXCITE T5

Fixture Built-in Sensor Daylight Harvest Version

LED Driver Constant voltage

User manual. KNX MultiController DALI. Article number: 5410x / 5411x. function Technology AS

LED Driver Constant voltage

ActiLume G2 Indus Sensor H513

COD GB / 1.0 RBAND/UMS - RBAND/CSM

LED Driver Constant voltage

Pair of PMR446 Two-Way Personal Radios Model: TP391

LED Driver Constant voltage

Smart-house Dimmer Power dimmer up to 500W Type SH2D500W230

LED Driver Constant voltage

KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx

INSTALLATION MANUAL FOR RADIO CONTROL SESAM 6099 TRANSMITTER

PCA T8 EXCEL one4all lp Y, W T8 fluorescent lamps

User Manual March 2008

Thorsten Reibel, Training & Qualification Global Application and Solution Team

LED Driver Compact dimming

USER MANUAL 2AMDI511VPVRDS

LC35/2-DA-iC. 35 W Dimmable two channel intelligent Colour LED driver. 35 W V 0 / Hz. Functional Description. Mains Characteristics

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification

V~ DIMMER WITH BUILT-IN RADIO RECEIVER AND DALI OUTPUT FOR CONTROL BALLASTS AND LAMPS. Push-button input for manual controls.

User Manual. KNX MultiLight Dali. Article number: function Technology AS. Picture: KNX MultiLight products

luxcontrol lighting control system DSI sensors smartdim SM lp Control module for combination with ambient light sensor, switch or presence sensor

CONTINUOUS DIMMING MOTION SENSOR & COMPATIBLE REMOTE PROGRAMMER MSITXLRD509 & RMTITXSRP280

LED Driver Constant voltage. Udriver LCA 100W 24V one4all SC PRE PREMIUM series

PREMIER INSTALLATION AND OPERATING INSTRUCTIONS

EY-EM 522, 523: Remote I/O module, ecolink522, 523

C-Bus DSI Gateway. 5508DSIP Series. Installation Instructions

ORDERING CODE Z-WAVE FREQUENCY COUNTRY/REGION

02/11/2015

EIB/KNX Switch Actuators. User manual

Human Centric Lighting System

DESCRIPTION & OPERATION: PIR OCCUPANCY SENSOR MSWSFSP221B-D FEATURES:

02/11/2015

LED Driver Linear / area dimming

ETC Installation Guide

Digital Electronic Thermostat With RF

TD - Power Supply LP DALI&Switch Dim Mono PRE (CV) MM-IP20 User Manual

IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL

1: White buttons Used by the user on a daily basis. 2: Grey buttons Used only upon first startup.

RF Remote Control Unit SEAV

Applications. HBT02 Transceiver Node. Features. Note: This datasheet is intended for information related to the hardware only.

PHASED OUT. DALI interface terminals are provided to allow control and monitoring via a seperate controller.

Emergency lighting units EM powerled

Wireless Room Thermostat Installation and Operation Y6630D1007

LED Driver Linear / area dimming

4612 Reference Guide

Astra-R Kit Wireless Alarm System Operation Manual

RDX Quick Start Guide

Installation and Operating Instructions. Power IT Power Factor Controller RVC

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1

LED Driver Linear / area dimming

Transcription:

AT-SL-DDR & AT-SL-DDR-SA Product Guide Slim-line RF DALI/DSI + relay controller Overview The AT-SL-DDR and AT-SL-DDR-SA are wireless controllers with two output channels capable of controlling incandescent, fluorescent and compact fluorescent lighting. Two versions are available. The AT-SL-DDR is designed for fitting inside a luminaire. The AT-SL-DDR-SA is suitable for mounting remotely. Fig 1: AT-SL-DDR Output Channel 1 comprises a mains voltage relay capable of simple on/off switching, while Output Channel 2 provides dimmable control of either DSI or DALI type ballasts. The unit also includes stored scenes for versatile manual control of lighting levels. These devices are integrated with other devices as part of an An-10 lighting control system. The built-in RF transceiver allows wireless communication with all other An-10 compatible products, e.g. the AT-BB-IN Input Unit, useful for push-button scene selection and absence detection. Fig 2: AT-SL-DDR-SA All functionality is fully programmable. Features Fig 3: Front features (AT-SL-DDR shown) IR Receiver Receives control and programming commands from an IR (infrared) handset (Fig.3). Status LEDs These flash Red and/or Green to indicate the following: Valid setting received Invalid setting received Software reset received Factory reset received Clear casing which covers... IR Receiver Status LEDs Dimmable Control Output Connector (Channel 2) Power input & switched output Connector (Channel 1) Power Input & Switched Output Connector (Channel 1) Used to connect mains power to the unit and to connect a switched load. Dimmable Control Output Connector (Channel 2) Used to connect DSI/DALI controllable ballasts and transformers for dimmable loads.

Installation AT-SL-DDR mounting Mount and wire the unit in the following method. Affix the AT-SL-DDR to the inside of a luminaire using M4 screws as shown in the diagram below (Fig. 4). Use a flat-bladed screwdriver to depress the spring actuators. Insert cable when the actuator is fully depressed. Release of the sprung actuator clamps the conductor. The sprung terminals are only suitable for solid core cable up to 1.5mm 2. Sprung actuator Fig 4: AT-SL-DDR mounting Fixing points AT-SL-DDR-SA mounting Mount and wire the unit in the following method. Remove terminal covers by unscrewing the clamp screws and inserting a small flat-bladed screwdriver into the slots shown in the diagram below (Fig. 5). Affix the AT-SL-DDR-SA using the fixing slots shown in the diagram below (Fig. 7). The fixing slots are suitable for M4 screws. Wire unit using the screw terminals. The screw terminals are suitable for solid core or stranded cable up to 2.5mm 2. Maximum cable OD 10mm. Ensure that the main cable sheathing is over the cable clamp area (Fig. 7). Clip on the terminal covers. Insert the clamp screws and screw up until the cable is firmly clamped. Release slots Fig 5: AT-SL-DDR-SA terminal cover Clamp screws Screw terminals Cable clamp area Fig 6: AT-SL-DDR-SA terminal cover Fig 7: AT-SL-DDR-SA mounting Fixing points IMPORTANT NOTICE! This device should be installed by a qualified electrician in accordance with the latest edition of the IEE Wiring Regulations and any applicable Building Regulations. 2

Wiring Channel 1 (switched output) of the AT-SL-DDR can either be used to switch a separate channel of standard, nondimming luminaires, or to isolate the mains supply to dimming ballasts (saving on the standby current of the ballasts). Multiple luminaires may be connected in parallel to Channel 1 (via the N and L/out terminals) as long as the maximum total load is not exceeded. Channel 2 (dimmable output) of the AT-SL-DDR can be used to control the light output of luminaires that are fitted with dimming ballasts/transformers. The ballasts/transformers can be connected in parallel to Channel 2 (via the DIM and DIM+ terminals). Ensure that correct polarity is maintained at each ballast. Refer to the specification on page 8 for ballast quantities. AT-SL-DDR wiring Fig 8: AT-SL-DDR wiring AT-SL-DDR-SA wiring Fig 9: AT-SL-DDR-SA wiring Fault finding What if the load does not turn ON? Check that the live supply to the circuit is good. Check that the load is functioning by bypassing the Controller (e.g. link terminals L/in and L/out on Channel1). Check that the unit is correctly addressed, see Step 1: Set channel addresses and channel load type on page 4. 3

Basic programming The functionality of the AT-SL-DDR is controlled by a number of parameters which can be changed or programmed by any of the following devices: UHS4 Infrared Handset UNLCDHS Infrared Handset (with LCD) For most basic programming operations the UHS4 handset is recommended and the following procedures are based on using this device. Point the handset at the Controller and send the required programming commands to the unit as shown in Steps 1, 2 and 3. Valid commands will be indicated by a green LED flash. See page 1 for details of other LED responses. Step 1: Set channel addresses and channel load type The Controller has two output channels: Channel 1 - Switched Output Channel 2 - Dimmable Output To relate the function of different channels it is necessary to set the addresses correctly. For example, a scene select message sent from a device with a Local Code of 1 will only be actioned by devices that also have a Local Code of 1. To program the settings for a specific channel on the Controller you must specify the appropriate channel number (i.e.1 to 2) using the programming device. If no channel number (or channel 0) is specified, all channels will be set to the same address. The output channels also have Circuit numbers. This allows different physical channels to be linked and controlled as a single Circuit. Channel 2 (the dimmable output) can control either DSI or DALI type ballasts. This is called the Load Type and is set to DSI by default. Note: for applications where there is only one channel of lighting being controlled in a room there is no need to select the channel number. 4

Basic programming Step 3: Re-program scenes The AT-SL-DDR has capacity to store 20 Local Scenes and 120 Area Scenes. By default all Scenes are preprogrammed with the following channel levels, but these can be changed as required: Each Scene has a Fade Rate, which is the time taken for the existing output channel levels to fade to the levels defined in the selected Scene. By default this is set to 3 seconds for all Scenes. Local Scenes 1 2 3 4 5 6... 19 20 Ch1 on on on on on on... on off Ch2 100% 75% 50% 25% 100% 75%... 50% 0% Area Scenes 101 102 103 104 105 106... 119 220 Ch1 on on on on on on... on off Ch2 100% 75% 50% 25% 100% 75%... 50% 0% NOTE: Local Scene 20 and Area Scene 120 are designated off scenes within a system and should normally be programmed with all channels off or at zero. 5

Advanced programming The tables on pages 6 and 7 give a summary of all programmable parameters for the AT-SL-DDR Controller. Parameter Name Default Value Range / Options Description Programming Devices UHS4 UNLCDHS For Device Product ID For Channel 2 (Dimmed Output) Local Code 1 1 to 999 A number corresponding to the Local Code of all devices to be controlled by an associated input channel. Sub Local Code(s) Not set 1 to 99 0 to clear Area Code(s) 999 1 to 999 0 to clear 6 Automatically assigned by the device A number corresponding to the Sub Local Code of all devices to be controlled by an associated input channel. Up to 20 Sub Local Codes can be set for Channel 1 and 2, e.g. 15 on Ch.1 and 5 on Ch.2, etc. A number corresponding to the Area Code of all devices to be controlled by an associated input channel. Up to 32 Area Codes can be set for Channel 1 and 2, e.g. up to 16 per channel, or 20 on Ch.1 and 12 on Ch.2, etc. Circuit Number 2 1 to 999 Sets the circuit number for this channel. Load Type DALI DSI or DALI Sets the ballast control protocol to be used by the output channel. Output Level Set by Scene 0 to 100 % The current output level of the channel, for example as set by a Scene Select command. Max Value 100% 0 to 100% Maximum dimming output level. Min Value 1% 0 to 100% Minimum dimming output level. Burn-in 0 0 (disabled) or 1 to 255 hours Raise from off 1 Enable (1) or disable Lower from off 1 Enable (1) or disable 1 to 999 A number used to uniquely identify each device within a range of devices that are set to the same Local Code. Building Code 1 1 to 999 A number shared by all devices that belong to the same building or system. Lock 0 Enable (1) or disable For Channel 1 (Switched Output) Lock the An-10 network. Prevents more devices joining the network. Local Code 1 1 to 999 A number corresponding to the Local Code of all devices to be controlled by an associated input channel. Sub Local Code(s) Not set 1 to 99 0 to clear Area Code(s) 999 1 to 999 0 to clear A number corresponding to the Sub Local Code of all devices to be controlled by an associated input channel. Up to 20 Sub Local Codes can be set for Channel 1 and 2, e.g. 15 on Ch.1 and 5 on Ch.2, etc. A number corresponding to the Area Code of all devices to be controlled by an associated input channel. Up to 32 Area Codes can be set for Channel 1 and 2, e.g. up to 16 per channel, or 20 on Ch.1 and 12 on Ch.2, etc. Circuit Number 1 1 to 999 Sets the circuit number for this channel. Output State Set by Scene 0-100% 0=off Raise from off 1 Enable (1) or disable Lower from off 1 Enable (1) or disable Emergency output 0 Enable (1) or disable The current output state of the channel, for example as set by a Scene Select command. Enables raise from off feature. Enables lower from off feature. Enabling this sets the output to a switched permanent live mode for emergency ballasts. Determines how long the output will be at 100% so that lamps burn -in. The burn-in time is not affected by power supply interruptions. Enables raise from off feature. Enables lower from off feature.

Advanced programming Parameter Name Default Value Range / Options Description Programming Devices Local On Scene Fade Rate Area On Scene Fade Rate 1 1 second 101 1 second 1 to 20 0 to 255* 101 to 220 0 to 255* UHS4 UNLCDHS The local scene request sent to all devices with the Local Code specified. The area scene request sent to all devices with the Area Code(s) specified. Local Off Scene Fade Rate Area Off Scene Fade Rate 20 1 second 220 1 second NOTE: The Area On Scene is ignored unless one or more Area Codes are set for the corresponding input channel and they match the Area Codes set in any output channel. 1 to 20 Time table 0 to 255* Value Fade rate time 0 No fade 1 to 59 1 to 59 seconds, in 1 second increments 1 to 20 60 to 177 1 to 59.5 minutes, in 0.5 0 to 255* minute increments 178 to 254 1 to 20 hours, in 15 minute increments 255 Infinite fade 7

Technical data Dimensions See diagrams opposite Weight 0.1kg Supply Voltage 230VAC +/- 10% Frequency 50Hz Maximum Load Channel 1 (switching): 2A of lighting and/or ventilation including incandescent, fluorescent, compact fluorescent, low voltage (by switching the primary of transformer). Channel 2 (dimming): Maximum number of DSI or DALI ballasts is 10 unless the relay is disabled then it is 20. Terminal Capacity AT-SL-DDR 1.5mm 2 Solid only AT-SL-DDR-SA 2.5mm 2 Solid and stranded. Maximum cable OD 10mm. Receiver Class 2 Transmitter Duty Cycle <10% on g3 band (default band) <0.1% on g2 band AT-SL-DDR AT-SL-DDR-SA Order code blank Region European Union -A2 Australia & New Zealand Radio frequency 868MHz Compliance EN300 220-2 V2.1.2 EN301 489-1 V1.8.1 EN301 489-3 V1.2.1 LVD-2006/95/EC 915MHz AS/NZS 4268:2008 <1% on g1 band Range The maximum RF range between An-10 devices is 100m in free air and up to 30m indoors. However the materials used within a building will vary and this will impact upon the RF range. In reality the nature of how the An-10 s hybrid-mesh works means that in most scenarios the individual range of an An-10 product will not be important. Temperature 0ºC to 35ºC Humidity 5 to 95% non-condensing Material (casing) Flame retardant polycarbonate Classifications Insulation Class II Purpose Automatic control Construction Independently mounted control for surface mounting. Type of action Type 1.B action (micro disconnection). Pollution Degree 2 Software Class A Rated impulse voltage, 4000V Part numbers EBDSPIR-AT-PRM EBDSPIR-AT-AD EBDSPIR-AT-DD AT-BB-IN AT-SL-R AT-SL-R-SA AT-SL-DDR AT-SL-DDR-SA AT-SL-ADR AT-SL-ADR-SA VITM4-ATMOD VITM6-ATMOD-AD VITM6-ATMOD-DD UHS4 UNLCDHS RF Ceiling PIR presence detector switched RF Ceiling PIR presence detector 1-10V dimming RF Ceiling PIR presence detector DALI/DSI dimming RF Input unit RF relay controller RF relay controller (standalone) RF DALI/DSI + relay controller RF DALI/DSI + relay controller (standalone) RF 1-10V + relay controller RF 1-10V + relay controller (standalone) RF Switching module RF VITM6 1-10V module RF VITM6 DALI/DSI module Programming IR handset Universal LCD IR handset Hereby, CP Electronics Ltd, declares that this AT-SL-DDR is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. The declaration of conformity may be obtained for CP Electronics Ltd Brent Crescent, London, NW10 7XR, UK. Due to our policy of continual product improvement CP Electronics reserves the right to alter the specification of this product without prior notice. 8 C.P. Electronics Ltd Brent Crescent London NW10 7XR Ref: #WD386 Issue 2