Laser LA-4P. Operating instructions

Similar documents
Laser LAX 300. Operating instructions

Laser LAX 300 G. Operating instructions

Multi-beam Self-leveling Line Laser

Instruction Manual. Self-Leveling Cross-Line Laser Level Model No and

QUAD 1000 OWNERS MANUAL OPERATION GUIDE

A510S Operation Manual

LAX 400 multi-line laser

STABILA compact laser: For all professionals. For all finishing trades.

STABILA compact lasers: For all finishing trades.

DE EN FR ECOLINE EL 609 BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI EXACTLY WHAT YOU NEED.

IMPORTANT: Read Before Using. Operating/Safety Instructions 8601-RL

Please read these instructions before use and keep for future reference

Seite 2 Standard-Empfänger. EN Operation Instructions

1 Symbols. 4 Foreseeable misuse Do not use the device as a laser pointer. Do not use the device in explosive or aggressive environments.

X2 LASER DISTANCE METER. Operating instruction

GETTING STARTED. Instructions IMPORTANT PS B PS B. Record the serial number from the tag on the door front.

INSTRUCTION MANUAL DW089-XE 3 BEAM LINE LASER

114-GB(cover,p1-12) 25/08/ :49 AM Page

Ricoh XR Speedlite 300P

Energate Foundation Meter Data Collector Installation Guide

P10 LASER DISTANCE MEASURE. IMPORTANT: Read before Using

3x Magnification. Digital Zoom to 6x. CAUTION: Do not point Infrared Emitter directly into eye at close range.

Operator's Manual. 10-in. Digital Multi-function LEVEL with Laser Trac. Model No

LASER ENHANCED REVOLVER GRIP OWNER S MANUAL RED LASER GREEN LASER

Operating Manual MRL-101

62120LLCP PRECISION LASER SIGHT AND LIGHT INSTRUCTION MANUAL

User Manual Laser distance sensor. series OWLE. Welotec GmbH Zum Hagenbach Laer Manual_OWLE _EN 1/20

USER MANUAL. Laser Distance Meter MODELS DT40M, DT60M, and DT100M

Table of Contents. Stabila LD 320 1

Pipe Laser Model No Instruction Manual

Assembly Instructions

Laser Distance Finder Extech DT500

Operating instructions Diffuse reflection sensor with background suppression. OJ51xx laser / / 2010

Geo EasyTrack Auto Tracking System for Line Lasers

Constable Oak Extension Dining Table

Photosynthetically Active Radiation (PAR) Smart Sensor (Part # S-LIA-M003)

P20 Zoom Flash Zoom Flash P20 P20 Zoomblitz Flash con zoom P20 Flash externo P20 Flash Zoom P20

INSTALLATION INSTRUCTIONS ROLLER SHADES

Operation. 1 of 14. Serial number label

PACIFIC LASER SYSTEMS. HVL100 Procedures

EXAMINER+ Manual V.1. ARROWHEAD FORENSICS Strang Line Road Lenexa, Kansas PHONE FAX

Installation instructions

QUANTUM Qflash T2 / X2 OPERATING INSTRUCTIONS

Laser Distance Finder Extech DT500

RIGGING MANUAL English

Operating Instructions GEMINI R

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

Detectores de metales y otros materiales digitales GMS120 bosch manual ingles

3B SCIENTIFIC PHYSICS

Receiver Type /Version Factory No. Frequency. Transmitter Type /Version Factory No. Frequency

433 MHZ TEMPERATURE STATION Instruction Manual

CONTENTS. User Safety 2 Introduction and CXR880 Accessories 3 CXR880 Diagram 4 CXR880 Keypad and Remote Control 5 Operating Instructions 6

Operating instructions Contrast sensor O5K / / 2016

WAREHOUSE HANGER INSTALLATION INSTRUCTIONS R H INS T A L L A TIO N INS T R U C TIO N S

3B SCIENTIFIC PHYSICS

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

Laser LAX 200. Operating instructions

Ambient Weather WS-0270 Wireless Indoor / Outdoor Thermometer with Indoor Humidity User Manual

Visit us at

Table of Contents. Makita LD050P 1

Wide Angle Ophthalmoscope Instructions

WS-7136U Wireless 433 MHz Temperature Station. Instruction Manual

Inspiration strikes. VS-210 FLASH. User s Manual

Installation Manual. Solid Plastic Toilet Partitions. IN CANADA & AREAS OTHER THAN U.S.A.: IN THE U.S.A.:

WS-9006U Wireless Temperature Station

3-band Portable Radio ROBERTS. Sound for Generations. Please read this manual before use

How To Measure Your Finished Opening

SUNNY BEAM REPEATER Transmission Range Increase for Sunny Beam

Contents. Page English 1. French. Spanish. Reset of MIN/MAX records 915 MHz Reception Mounting Care and Maintenance Warranty Information

IMPORTANT!!! ASSEMBLY ASSEMBLY INSTRUCTIONS. (Internal Dimensions)

Ambient Light Rejecting Fixed Frame Screen. (3.9 width frame) User s Guide

PMT-L31 (for Low Ceilings) PMT-H35 (for High Ceilings)

AH Auto-Darkening Welding Helmet User Manual. Made in China

User instructions Compound laboratory microscope

INSTRUCTION MANUAL INF Fax: (503)

Manifold Electronic Gauge. Model: KC-100B-1 Operation Manual

Merloni Elettrodomestici. Technical Fitting Manual FRIDGE. Language Issue/Edition Page GB /

AP-N1001 FLASH USER S MANUAL

Installation Operation Care

Color Video Projector

SlimScan BT Users Manual

Bidirectional Ultrasonic Distance Measurement

DE EN FR IT ES RU PL DA NL NO SV

Sliding Door Enclosure. Telephone Cleaning. Please retain this manual after installation for future reference and maintenance.

ATD AMP Variable Speed Reciprocating Saw Owner s Manual

Ricoh Speedlite PX Flash Unit This camera manual library is for reference and historical purposes, all rights reserved.

GREENHOUSE 6'x8' ASSEMBLY INSTRUCTIONS. (Internal Dimensions) Overall Dimensions (Approx.) L 193 W 200 H cms 97.5" L 76" W 78.

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

OPERATING MANUAL SESAM 800 MOBILE TAIL LIFT EN -D0

USER MANUAL. ReadyFire G6 and IR6 Laser Sight SM25008 SM25009

Assembly Instructions for model: VMPR1

Hinge Door + Inline Panel + Return Panel

WS-7220U-IT 915 MHz Wireless Weather Station. Instruction Manual

CashConcepts CCE 4000

Showpiece Cabinet Integrated Stand For 32" - 52" LCD HDTV

ezframe CineGrey 5D Ambient Light Rejecting Fixed Frame Screen

WIRELESS 915 MHz TEMPERATURE STATION Instruction Manual

DP-19 DUAL PURPOSE DETECTOR INSTRUCTION MANUAL

BORE ALIGNMENT. Straightness measurement of bore and bearing journals PRINTER CONNECTION PC PROGRAM INCLUDED ELECTRONIC INCLINOMETER EXPANDABLE

LOFT DOOR HANGER BARN DOORS & HARDWARE. Hardware Installation Instructions. Page

Transcription:

Laser LA-4P GB Operating instructions

A 1 2 3a 5 3c 3b 3a 4 11 11 6 10 7 14a 14b 14c 12 9 8

B C 2. 1. D E F Ø 50mm - 115 mm Ø 2-4,5 G

I K s > 6m > 20ft L M N P1 Q O 13 P2

GB Operating instructions The STABILA LA-4P laser is an easy-to-use four-point laser for horizontal and vertical levelling and plumb lines. This simple-to-use tool allows you to transfer points between the floor and ceiling and to establish 90 points for laying out wall lines and putting up wall partitions. You can also use the laser for other applications where true plumb, square, and level setups are required.it is self-levelling in a range of ± 4. We have endeavoured to explain the unit's handling and functioning in as clear and comprehensible manner as possible. If, however, you still have any unanswered questions, we should be pleased to provide advice over the telephone at any time on the following telephone number: 0049 / 63 46 / 3 09-470 A G O P Q N Main components (1) ON/OFF switch (2) Green LED: Operating mode ON or READY / OK (3a) Vertical beam emission aperture (3b) Horizontal beam emission outlet: front (3c) Horizontal beam emission outlet: 90 (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) Battery compartment cover Protective cover 1/4" threaded connector for tripod Adapter Centring feet Centring feet locking system Hook Magnets 5/8" threaded connector for tripod Adapter wall bracket Fastening holes for: a) Nails / screws b) Screws c) Strap 10

Getting started Press the power button. The green power-status LED lights to show that the laser is on. Holding down the ON / OFF key for 3 seconds activates automatic switch-off after 60 minutes. 1 Place the laser on a flat surface. The laser must be within ±4 of being level for it to self-level. Tip: Please note that if the laser beams are to travel through glass or other transparent materials, this can adversely affect the laser's accuracy Setting Up the Laser and Transferring a Point Adjust the position of the laser so that the down beam is on the control point. Locate the position of the up beam and level beam. Make a mark on the ceiling and wall respectively. Please note that the centre of laser dot is marked! Plumbing a Wall 1. 2. 3. Place the laser so that the bottom feet are on the front edge of the bottom track. Switch the unit on ( button 1) Illuminated green LED -> laser in operation Adjust the top of the partition until the up beam is on the front edge of the top track. D 1 E Transferring drill hole points : With the adapter, you can easily perpendicularly transfer the centre points for drill holes with diameters of 50mm (1,96 ) to 115 mm ( 4,72 ). C 1. 2. 3. Place the adapter with the centring feet in the drill hole. Slide the lock in the direction of the arrow. The centring feet now centre the adapter precisely in the drill hole. The drill hole point can now be perpendicularly transferred quite easily. F G 11

Checking the calibration The LA-4P four-point laser has been designed for building site use and leaves our factory perfectly calibrated. As with any precision instrument, however, its calibration must be regularly checked. The unit should be checked before starting any new tasks, particularly when the unit has been exposed to strong vibrations. After an impact, the unit should be checked throughout its whole self-levelling range. Checking plumblining 1 1. 2. Switch the unit on ( button 1) Place the laser so that its down beam is over a reference mark on the floor. 3. Locate the position of the up beam on the ceiling and make a mark. 4. Rotate the laser 180 and realign the down beam over the reference mark on the floor. 5. Locate the position of the up beam on the ceiling, which will be twice the actual error, and make a mark. < 6mm < 3 /16 6. Measure the difference between the two marks on the ceiling, which will be twice the actual error. The difference may not be greater than: 6mm in 7.5 m (3/16 in 25 ft), 7,5m / 25 ft 12

Horizontal checking Two parallel wall surfaces at least 6m ( or 20 ft) apart are required for the horizontal check. 1. Set the four-point laser on a flat surface, or mount it on a tripod, at a distance of 50 to 75mm ( 1,96 to 2,95 ) from a wall A, with its front sidefacing the wall. 2. 3. 4. 5. 6. 7. Switch the unit on ( button 1) Mark the position of the visible laser dot on the wall (point 1) Turn the complete unit 180 without altering the height of the laser. Mark the position of the visible laser dot on the wall (point 2). Now move the unit directly in front of wall B Set the unit's height so that the laser dot's height matches that of point 2. 1 I K L 8. Without changing the height of the laser, rotate it 180 to place the beam near M the mark on the first wall (step 3 / point 1 ). Measure the vertical distance between the beam and the mark made in step 3. The difference may not be greater than: 6m 12m 18m 24m S / 20 ft / 40 ft / 60 ft / 80 ft Measured Value 3,0 mm 6,0 mm 8,0mm 11,0mm 1/8 inch 1/4 inch 5/16 inch 7/16 inch 13

Checking Level to Square Beam 90 Calibration 1. Find a room at least 10 m (35 ft) long. Mark a point (A) on the floor at one end of the room. 2. Set up the laser so that its down beam is over point A. Make sure the level beam points toward the far end of the room. 3. Mark a point (B) on the floor at the center of the room using a target to transfer the level beam location to the floor. 4. Mark a point (C) on the far wall or transfer the level beam location to the floor. 5. Move the LA-4P to point B and align the level beam to point C again. 6. Mark the location of the square beam (D) on the floor. Tip: To ensure accuracy, the distances from A to B, B to C, and B to D should be equal. 7. 8. 9. Turn the LA-4P 90 so that the level beam aligns with point D. Mark the location of the square beam (E) on the floor as close as possible to point A. Measure the distance between points A and E. Room length or distance between points A and C 10 m (35 ft) 20 m (70 ft) The 90 angle between the level beam and square beam is out of calibration if the distance between points A and E is: > 9,0 mm (3/8 inch) > 18,0 mm (3/4 inch) 14

Replacing the batteries Slide the battery cover (4) in the direction of the arrow and insert new batteries in accordance with the symbols in the battery compartment. 4 x 1,5V alkaline mignoncells, size AA, LR6 Tip: Remove the batteries if the unit will not be used for a long period! Recycling programme for our EU customers: In accordance with the WEEE regulations, STABILA provides a disposal programme for electronic products at the end of their service life. For more details, please contact: www.stabila.de / Recycling or: 0049 / 6346 / 309-0 NB: In Class II laser equipment, your eyes are protected from accidental, shortterm exposure to the laser beam by the lid-closing reflex and/or the reflex reaction to turn one's head. This equipment can therefore be used without additional protective measures. Nevertheless, you should not look directly into the laser beam. Do not let the unit fall into children's hands! EN 60825-1 : 03 10 The laser goggles enclosed with these units are not safety goggles. They are designed to make the laser light easier to see. 15

Care and maintenance Dirty lens glass on the beam emitter detracts from the quality of the beam. It should be cleaned with a soft cloth. Clean the laser unit with a damp cloth. Do not spray or immerse the unit! Do not use solvents or thinners! The LA-4P four-point laser must be handled carefully, in the same way as any precision optical instrument. Tip: The laser unit should be allowed sufficient time to adjust to the ambient temperature before you start it up. For example, when the laser is brought from an extremely hot / cold vehicle onto the building site. When you re not using the laser, store it in its pouch/carrying case. Do not store the laser in a wet pouch/carrying case. If the pouch/carrying case gets wet, let it dry before storing the laser in it. Do not submerge the laser. Operating status display and error messages via the LEDs Illuminated green LED Laser beam flashing Flashing green LED -> laser in operation -> The unit is inclined too much + is outside the self-levelling range + the laser cannot level itself automatically -> laser in operation -> battery voltage very low -> battery replacement required imminently 16

Technical data Laser type: Output: Red diode laser, wavelength 635 nm < 1 mw, Laser Class 2 to EN 60825-1:03-10 Working Range*: 20-30m (65 100 ft) Self-levelling range: *: (horizontal) Levelling accuracy: Up Beam Accuracy*: Down Beam Accuracy ca. ± 4 ± 6 mm / 21m ± 1 mm / 0,5m ( +/ 1/4 in. @ 70 ft ) ( +/ 1/16 in. @ 2.5 ft ) Level Beam Accuracy*: Square Beam Accuracy*: Batteries: Operating life: Operating temperature range: ± 6 mm / 30m ( +/ 1/4 in. @ 100 ft ) ± 6 mm / 30m ( +/ 1/4 in. @ 100 ft ) 4 x 1,5 V Mignon cells Alkaline, Size AA, LR6 Approx. 40 hours -10 C to +45 C (14 F to 113 F) Subject to technical modifications. * At 20 C ( 50 F ) Guarantee terms and conditions Stabila provides a guarantee against deficiencies and faults in the assured characteristics because of material or manufacturing faults for a period of 24 months from date of purchase. Any faults will be eliminated at Stabila's own discretion either by repairing or replacing the unit. Stabila accepts no wider claims. No liability is accepted for any faults due to inappropriate treatment (e.g. damage caused by the unit falling, operation with the wrong voltage or type of current, use of unsuitable current supply sources) or for any autonomous changes made to the unit by the purchaser or a third party. Also no claims under guarantee are accepted for natural wear and tear or any small faults that do not significantly affect the unit's operation. Any guarantee claims must be made via the dealer on the duly completed guarantee form (see last page) to be returned with the unit. 17