UPQC with Islanding and Grid Connection for Microgrid Applications

Similar documents
Coping Smartly!! with Harmonic Penetration, Propagation and Interaction in the Distribution Network. Dr. Malabika Basu

Unified Power Quality Conditioner (UPQC) in Alleviation of Power Quality Issues

Mitigation of Voltage Sag/Swell Using UPQC

UPQC for Power Quality Improvement in DG Integrated Smart Grid Network: a Review

Voltage Support and Reactive Power Control in Micro-grid using DG

Power Quality improvement of a three phase four wire system using UPQC

Downloaded from

Interactive Distributed Generation Interface for Flexible Micro-Grid Operation in Smart Distribution Systems

MODELING AND SIMULATION OF UNIFIED POWER QUALITY CONDITIONER FOR POWER QUALITY IMPROVEMENT

A Versatile Control Scheme for UPQC for Power Quality Improvement using fuzzy controller

Power Quality Improvement by Simultaneous Controlling of Active and Reactive Powers in UPQC-S

Improvement of Power Quality using Unified Power Quality Conditioner with Distributed Generation

B.Tech Academic Projects EEE (Simulation)

A Power Control Scheme for UPQC for Power Quality Improvement

Enhancement of Power Quality Using Advanced Series Active Power Filters

Simulation and Implementation of DVR for Voltage Sag Compensation

Reduction of Circulating Current Flow in Parallel Operation of APF Based on Hysteresis Current Control

ISSN Vol.07,Issue.21, December-2015, Pages:

Development and Simulation of Dynamic Voltage Restorer for Voltage SAG Mitigation using Matrix Converter

UNIFIED POWER QUALITY CONDITIONER IN DISTRIBUTION SYSTEM FOR ENHANCING POWER QUALITY

CHAPTER 4 PV-UPQC BASED HARMONICS REDUCTION IN POWER DISTRIBUTION SYSTEMS

ISSN: [Bhat * et al., 7(8): August, 2018] Impact Factor: 5.164

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Simulation of Multi Converter Unified Power Quality Conditioner for Two Feeder Distribution System

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Acknowledgements Introduction p. 1 Electric Power Quality p. 3 Impacts of Power Quality Problems on End Users p. 4 Power Quality Standards p.

Reduction of Voltage Imbalance in a Two Feeder Distribution System Using Iupqc

IMPROVEMENT OF POWER QUALITY USING CUSTOM POWER DEVICES

ANALYSIS OF SYNCHRONOUS-REFERENCE-FRAME-BASED CONTROL METHOD FOR UPQC UNDER UNBALANCED AND DISTORTED LOAD CONDITIONS Salava Nagaraju* 1

LOAD REACTIVE POWER COMPENSATION BY USING SERIES INVERTER OF UPQC

Flexible Voltage Control Scheme for Distributed Generation Systems under Grid Fault

Power Quality Improvement using Hysteresis Voltage Control of DVR

IMPROVING EFFICIENCY OF ACTIVE POWER FILTER FOR RENEWABLE POWER GENERATION SYSTEMS BY USING PREDICTIVE CONTROL METHOD AND FUZZY LOGIC CONTROL METHOD

Power Quality Improvement of Unified Power Quality Conditioner Using Reference Signal Generation Method

International Journal of Research (IJR) e-issn: , p- ISSN: X Volume 2, Issue 09, September 2015

2020 P a g e. Figure.2: Line diagram of series active power filter.

STUDY OF CIRCULATING CURRENT PHENOMENA IN MULTIPLE PARALLEL INVERTERS OPERATING IN MICROGRID

p. 1 p. 6 p. 22 p. 46 p. 58

A Modified Control Method For A Dual Unified Power Quality Conditioner

This is a refereed journal and all articles are professionally screened and reviewed. Electromechanical Active Filter as a Novel Custom Power device

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

SEIG based Facts Device for the Three phase Non-Linear Loads

Application of Fuzzy Logic Controller in Shunt Active Power Filter

Unit Vector Theory based Unified Power Quality Conditioner for Power Quality Improvement

Kalman Filter Based Unified Power Quality Conditioner for Output Regulation

Active Power Sharing and Frequency Control of Multiple Distributed Generators in A Microgrid

Design of Unified Power Quality Conditioner (UPQC) Connected To Three Phase Four Wire System

HYSTERESIS CONTROL FOR CURRENT HARMONICS SUPPRESSION USING SHUNT ACTIVE FILTER. Rajesh Kr. Ahuja

FUZZY LOGIC CONTROL BASED DYNAMIC VOLTAGE RESTORER FOR POWER QUALITY IMPROVEMENT IN DISTRIBUTION SYSTEM

UPQC for Improvement Power Quality.

Design of UPQC with constant frequency controlled scheme for removal of Total Harmonic Distortion

CHAPTER 5 CONTROL SYSTEM DESIGN FOR UPFC

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Power Quality Improvement in Fourteen Bus System using UPQC

POWER QUALITY ASSESSMENT AND ENHANCEMENT IN A GRID CONNECTED RENEWABLE ENERGY SYSTEM USING DYNAMIC VOLTAGE RESTORER

Design Strategy for Optimum Rating Selection of Interline D-STATCOM

Modeling & Simulation of Micro Grid Distribution System to reduce Harmonics Using Active Power Filters and PI controllers

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

SIMULATION VERIFICATION OF DYNAMIC VOLTAGE RESTORER USING HYSTERESIS BAND VOLTAGE CONTROL

Keyword: Distributed System, Filters, Harmonics, Power quality improvement, THD, UPQC and Voltage Harmonics.

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

A DYNAMIC VOLTAGE RESTORER (DVR) BASED MITIGATION SCHEME FOR VOLTAGE SAG AND SWELL

Protection from Voltage Sags and Swells by Using FACTS Controller

ANALYSIS OF UNIFIED POWER QUALITY CONDITIONER DURING VOLTAGE SAG AND SWELL CONDITIONS

INTERLINE UNIFIED POWER QUALITY CONDITIONER: DESIGN AND SIMULATION

ISSN Vol.04,Issue.16, October-2016, Pages:

A CONTROL TECHNIQUE FOR INSTANT MITIGATION OF VOLTAGE SAG/SWELL BY DYNAMIC VOLTAGE RESTORER

Implementation of UPQC for Voltage Sag Mitigation

Analysis and modeling of thyristor controlled series capacitor for the reduction of voltage sag Manisha Chadar

Performance of DVR under various Fault conditions in Electrical Distribution System

Sinusoidal Current Control based Shunt Active Power Filter for Current Harmonics Reduction

A Specialized UPQC for Combined Simultaneous Voltage Sag/ Swell Problems in Distribution System

Analysis & Function of Unified Power Quality Conditioner for Power Quality Improvement of Distributed Network

Power angle control of UPQC to compensate load reactive power and voltage sag /swells

Power Quality enhancement of a distribution line with DSTATCOM

Islanding Detection Technique based on Simulation of IEEE16 Bus System

SIMULATION OF MULTI CONVERTER BASED UNIFIED POWER-QUALITY (MC-UPQC) CONDITIONING SYSTEM ON VOLTAGE STABILITY OF RADIAL DISTRIBUTION SYSTEMS

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

A Review on Improvement of Power Quality using D-STATCOM

Multiconverter Unified Power-Quality Conditioning System: MC-UPQC T.Charan Singh, L.Kishore, T.Sripal Reddy

Improvement of Power Quality Using a Hybrid Interline UPQC

Enhancement of Power Quality based on Unified Power Quality Conditioner (UPQC) K.S.Srikanth, Shaik. Musthak Ahmed, Y.Srinivasa Rao

WITH THE advent of advanced power-electronics technologies,

A Novel Approach to Simultaneous Voltage Sag/Swell and Load Reactive Power Compensations Using UPQC

State of Charge (SOC)-Based Active Power Sharing Method for Distributed Generations in an Islanded Microgrid

Mitigation of Current Harmonics with Combined p-q and Id-IqControl Strategies for Fuzzy Controller Based 3Phase 4Wire Shunt Active Filter

Design and Simulation of Active Power and Power Angle Control of UPQC to Mitigate Voltage Sag/Swell and Load Reactive Power Compensation

Current Control Strategy for Parallel Operation of Inverters Based On Micro grids M.Bavithra 1, Belwin J. Brearley 2

Microgrid Connection Management based on an Intelligent Connection Agent

Modified three phase Unified Power Quality Conditioner with capacitor midpoint topology

Design of Interline Dynamic Voltage Restorer for Voltage Sag Compensation

SIMULATION OF D-STATCOM AND DVR IN POWER SYSTEMS

Power Quality Improvement By Using CHB Inverter Based DVR

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

COMPENSATION OF VOLTAGE SAG USING LEVEL SHIFTED CARRIER PULSE WIDTH MODULATED ASYMMETRIC CASCADED MLI BASED DVR SYSTEM G.Boobalan 1 and N.

SIMULATION AND COMPARISON OF SPWM AND SVPWM CONTROL FOR TWO LEVEL UPQC

DESIGN AND DEVELOPMENT OF SMES BASED DVR MODEL IN SIMULINK

Power Quality Compensation by using UPFC

Control of Power Converters for Distributed Generation

Harmonics Reduction using 4-Leg Shunt Active Power Filters

Transcription:

International Journal of Scientific and Research Publications, Volume 6, Issue 8, August 2016 214 UPQC with Islanding and Grid Connection for Microgrid Applications Harshitha. M R, Sharmila. R S, Dr. G. C Shivasharanappa, Dr. R. Prakash ept. of Electrical and Electronics Engineering,Don Bosco Institute of Technology, Bangalore, India Abstract- The micro-grids are interconnection of renewable resources available at distribution side.micro -grids can be operated in three different ways grid connected mode, autonomous mode and micro generation mode.the battery system is connected in DC link for supplying real power in the micro-grid.quality of power supply has become an important issue with the increasing demand of DG system either connected to the conventional grid, smart grid or micro grid. Most of the pollution issues created in power systems are due to the nonlinear characteristics and fast switching of power electronic devices which introduce harmonic in the line voltage and current.to eliminate the power quality issues from the distribution system it is essential to improve the reliability of the system. The Unified Power Quality Conditioner (UPQC) is used to to improve the real power by improving the quality of supply during the interconnected and islanded mode. Here UPQC is connected with micro-grid to improve the power quality and reduce the oscillations when the mode of the connection changes.the new control strategy is used for the integration and control of Unified Power Quality Conditioner in distribution generation based micro-grid system. Index Terms- Unified Power Quality Compensator, Micro grid, Power Quality, Islanding Detection, Synchronous reconnection, Distribution Generation. I. INTRODUCTION he challenging issues of a successful placement and Tintegration of unified power quality conditioner (UPQC) in a distributed generation (DG)-based grid connected microgrid (μg) system are 1) Control complexity for active power transfer; 2) ability to compensate non-active power during the islanded mode; and 3) difficulty in the capacity embellishment in a modular way [1]. For a smooth power transfer between the grid-connected system and islanded mode, various operational changes are presented, such as switching between the current and voltage control mode, robustness against the islanding detection and reconnection delays and method and so on [2], [4]. Clearly, these further further increase the control complexity of the microgrid systems. To extend the operational flexibility and to improve the power quality in grid connected microgrid systems, a new control strategy placement and integration technique of UPQC have been proposed in [3], which is termed as UPQCμG.In the UPQCμG integrated distributed system, micro grid (with storage) and shunt part of the UPQCμG are placed at the Point of common coupling. The series of the UPQC is placed before the Point of common coupling and in series with the grid. DC link is connected to the storage also, if present. To maintain the operation in island mode and reconnection through the UPQC, communication process between the UPQC micro grid and micro grid system is mentioned in [3]. In the present work, the control technique of the presented UPQC micro grid in [3] is enhanced by implementing an islanding and novel reconnection technique with reduced number of switches that will ensure smooth operation of the micro grid without interruption. Hence it is termed as UPQC micro grid IR. The objective of this paper is to study the various types of power quality problems and their effects in distribution generation based grid connected microgrid system, to investigate that the mitigation techniques are suitable for voltage sag/ swell and interruptions in the event of a fault in a distribution generation based grid connected microgrid system.to observe the effect on the characteristic of voltage sag / swell and interruption for the techniques. Construct the micro grid control for all modes of operations, with more emphasis on: voltage sag / swell, harmonic and reactive power compensation and active power transfer to the load in the interconnected mode and how they can be mitigated with the use of the Unified Power Quality Conditioner (UPQC), which are also called custom power devices. In this paper Different power quality issues their causes and consequences and solution have been discussed with islanding and reconnection technique. The modelling of series APF, shunt APF, PSD, Islanding detection and Reconnection and the UPQC has been carried out.using hysteresis band controller the model has been developed. From the simulation results UPQC improves the power quality of power system during sag, swell and interruption condition with islanding condition.the THD of the source current and load current is reduced.the Methodology of the proposed system is described in section II. Based on the working principle and methodology, some of the controller design deals with the section III with islanding detection and reconnection techniques in detail. Section IV shows the performance study result. II. METHODOLOGY The Integration technique of the proposed UPQC micro grid IR to a grid connected and DG integrated micro grid system is presented in Fig 1(a). S1 and S2 are the breaker switches that are used to island and reconnect the micro grid system to the grid as directed by the secondary control of the UPQC micro grid IR. The working principle during the interconnected and islanded mode for this configuration is shown in the Fig 1(b, c). The

International Journal of Scientific and Research Publications, Volume 6, Issue 8, August 2016 215 operation of UPQC micro grid- IR can be divided into two modes. A. Interconnected mode In this mode, as shown in Fig 1(b); 1. The DG source delivers only the fundamental active power to the grid, storage and load. 2. The APFsh compensates the reactive power and harmonic power (QH) of the non-linear load to keep the THD at the PCC within the IEEE standard limit. 3.Voltagesagswell/interruption can be compensated by the active power from the grid/storage through the APFse. DG converter does not sense any kind of voltage disturbance at the PCC and hence remains connected in any condition. 4. If the voltage interruption/black out occurs, UPQC sends a signal within a pre-set time to the DG converter to be islanded. B. Islanded mode In this case, as shown in Fig 1(c); 1. The APFse is disconnected during the grid failure and DG converter remains connected to maintain the voltage at PCC. 2. The APFsh still compensates the non-active power of the non-linear load to maintain undistorted current at PCC for other linear loads. 3. Therefore, DG converter (with storage) delivers only the active power and hence does not need to be disconnected from the system. 4. The APFse is reconnected once the grid power is available. Fig 1 (a) Fig 1(c) Fig 1 (a) Shows Integration Technique of UPQC μg-ir,fig 1(b) Working principle in Interconnected Mode, Fig 1 (c) Working Principle in Islanded Mode III. CONTROLLER DESIGN The block diagram of the proposed UPQC microgrid-ir Controller is shown in Fig 2. It has the same basic functions as the UPQC controller except for the additional islanding detection and reconnection techniques and capabilities. A signals transfer between the proposed UPQCμG-IR and the micro grid is also required for the seamless operation. These signals generation are based on the voltage sag/swell/interrupt/ failure of supply conditions. This has been performed in secondary control (LEVEL-2) of the hierarchical control [6]. Primary control deals with the Level 1 of the UPQC to perform their basic functions in the interconnected and the islanded mode [7]. The overall integration technique and control strategy are used to improve the quality of supply during interconnected and islanded modes. This technique involves detecting islanding and reconnection that secures the DG converter remains connected and supply active power to the load. This reduces the control intricacy of the converter as well as the power failure possibility in the islanded mode. The main Controllers of the proposed system are Series part (APFse) Control, Shunt part (APFsh) Control, Intelligent Islanding Detection (IsD) and Synchronization and Reconnection (SynRec). As the Islanding detection and Synchronous Reconnection features are new in UPQC therefore, these have been presented in details. Fig 1(b) A. Intelligent Islanding Detection (IsD) Considering the future trends towards the smart-grid and micro grid operation in connection with the distribution grid, it have a capability of (i) maintaining connection during grid fault condition, (ii) automatically identified and detecting the islanded condition and (iii) reconnecting after the grid fault. These are the most important features of the micro grid system. In that case, the placement of APFse in the proposed integration method of the system plays an important role by improving the operational flexibility of the DG converter in the microgrid system.

International Journal of Scientific and Research Publications, Volume 6, Issue 8, August 2016 216 In addition to the islanding detection, changing the control strategy from current to voltage control may result in serious voltage problems and it becomes serious when the islanding detection is delayed in the case of hierarchical control. Therefore seamless/smooth voltage transfer control between the gridconnected and isolated controlled modes is very important to mitigate the voltage transients in transition mode, but these then increase the control complexity of the μg converters. Fig 2: Block diagram of the UPQC μg-ir (a) Controller (b) Control algorithm In the case of power quality problems, it is reported that more than 95% of voltage sags can be compensated by injecting a voltage up to 60% of the nominal voltage, with a maximum duration of 30 cycles. Therefore, based on the islanding detection requirement and sag/swell/interrupt compensation, islanding is detected and a signal Sμ-1, as shown in Fig 2(b),signal is also generated in the proposed UPQC microgrid-ir to transfer it to the DG converters. As the series active power filter takes the responsibility for compensating voltage sag/swell/unbalance disturbances.intelligence islanding detection algorithm in the proposed UPQC microgrid-ir can be simple and quite flexible. On the other hand, it will help to minimize the complexity of islanding detection technique. Fig 3: Algorithm for IsD method in UPQCμG-IR Fig 3 shows a simple algorithm for IsD method with example that has been used to detect the islanding condition to operate the UPQC in islanded mode. The voltage at the point of common coupling is taken as the reference and it is always in phase with the source and the DG converters, the difference between the Vpcc-ref (pu) and Vs (pu) is Verror. This Verror is then compared with the pre-set values (0.1 to 0.9) and a waiting period (user defined n cycles).it is used to determine the voltage sag/interrupt/islanding condition. In this example, (i) if is less

International Journal of Scientific and Research Publications, Volume 6, Issue 8, August 2016 217 than or equal to 0.7, then 70% sag will be compensated for up to 50 cycles; (ii) if is in between 0.7 to 0.9, then compensation will be for 30 cycles; (iii) otherwise (Vsag-max ) it will be interrupt/black out for islanding after 1 cycle. This type of signal generation method is simple and it can also be adjusted for any time period and condition. Thus this technique can be achieved by introducing the operational flexibility of time and control of voltage sag/swell/interrupt compensation before islanding. As the smooth voltage transfer from grid connected to isolated mode is one of the critical cases in transition periods, the voltage transfer is completed at the zero crossing position of the series active power filter. Therefore, no voltage distortion or fault conditions occur. B. Synchronization and Reconnection (SynRec) Once the grid system is restored, the micro grid may be reconnected to the main grid and return to its pre-disturbance condition. A smooth or seamless reconnection can be achieved when the difference between the voltage magnitude, phase and frequency of the two buses are minimized or close to zero. The smooth reconnection also depends on the performance and accurate results of the synchronization methods. In case of UPQC micro grid-ir, reconnection is performed by the series APF.Moreover, due to the control of voltage sag/swell by the series APF, this UPQC micro grid-ir has the advantage of reconnection technique even in case of phase difference/jump (up to a some limit) between the utility voltage and at the Point of common coupling. This absolutely increases the operational flexibility of the microgrid system with high power quality. The phase difference limit depends on the rating of the series APF and the level of Vsag-max required for compensation. Assuming that the possible Vsag-max = Vs = Vpcc, the Ɵsag-max can be; Ɵsag-max = cos [(Ɵs-Ɵpcc)] inverse =20 degree The relation for the magnitude and phase difference Vpcc, Vsag and Vscan be obtained. The zero-crossing point of the Vsag-ref depending upon the phase. This zero-crossing detection also indicates the point at which the instantaneous voltage difference between the utility and the PCC becomes zero. Detection of this zero-crossing point and activation of the switches S1 and S2, as shown in Fig 1, at the same time are the key control of this reconnection method for a seamless transfer from the off-grid to the on-grid condition as well as changing the controller of the DG inverter from voltage to current control mode. The reconnection method is shown in Fig 4(b). Conditions for reconnection are set as; (i) assuming the phase difference between the utility grid and DG unit should be within Ɵsag-max, (ii) the instantaneous value of the two bus voltages becomes equal and (iii) these should occur at the zero crossing condition. Once the utility supply is available after a blackout, a synchronization pulse (generated in reconnection process) is enabled to start synchronization. A simple logic sequence is then created, based on the condition shown in Fig 6(b), to generate the active pulse for S2 and S3 to return the system in the interconnected mode. At the same time Sμg-IR, as shown in Fig 4(b) is also transferred to the μg system for reconnection. The other advantage is that, IsD and SynRec methods have been carried out as a secondary control in Level 2, i.e. these can also be added in conventional UPQC system as an additional block to convert it to UPQCmicrogrid-IR. It is to be noted that Fig 4 (a) Synchronization and Reconnection method the proposed UPQCmicrogrid-IR will be helpful to meet the required advanced grid integration features as mentioned. IV. RESULTS AND DISCUSSIONS The simulation results of SHU APF, SER APF, islanding & reconnection technique for microgrid with the unified power quality conditioner to evaluate the offered control stratagem. The simulation models have been established by MATLAB/SIMULINK environment. The simulation results under voltage sag and swell condition with islanding and reconnection are presented. Additionally, the simulation outcome under distorted voltage condition is also presented. The simulation results for UPQC with islanding and reconnection method is presented.

International Journal of Scientific and Research Publications, Volume 6, Issue 8, August 2016 218 Fig 5 (b) Fig 5 (a) According to the IsD method, the APFse compensates the sag for up to 0.6 sec (30 cycles) and then the system goes into islanded mode. A utility disconnection is applied at 1.11 sec just after completing the 30 cycle count and then detecting the zero crossing of where S1 and S2 are opened. At disconnection, the μg operates in islanded mode. At this stage, if the available DG power is lower than the load demand, the required power is supplied by the storage. Fig5 (a) Switching positions during the islanding operation; (b) voltage and current waveforms at Ɵs=20 degree If the DG power is higher than the load, then the additional power goes to the storage. The APFsh still performs the compensation of non-active power. Therefore, DG converter does not need to be disconnected or change the control strategy (supply only the fundamental active power) to supply power to the load. Fig 5 shows the performance of the proposed during 0.01 to 0.25 sec where the islanding is detected just immediately after 0.07 sec at zero crossing detection. The islanding mode is observed between 0.08 and 0.25 sec. Fig 6: Performance of (a) series APF, (b) shunt APF During this period the APFse is disconnected, as shown in Fig 6(a) where, and becomes zero, as shown in Fig 6(b). The APFsh continues to operate, shown in Fig6 (b), and the load fundamental is met by the DG and storage.

International Journal of Scientific and Research Publications, Volume 6, Issue 8, August 2016 219 Fig 6.1: Simulation results of UPQC a) load voltage b) load current c) series injected voltage d)grid Current e)injected Current Fig 7: Total Harmonic Distortion a) Load current, b)source current Fig. 7(a-b) shows the harmonic spectrum of load current and source current for phase-aafter UPQC is put in operation. THD of load current is 24.66%. With shunt APF in operation there is a significant reduction in THD at source side current from, 24.66% to 0.08%. Shunt APF is able to decrease thecurrent harmonics entering into source side.

International Journal of Scientific and Research Publications, Volume 6, Issue 8, August 2016 220 Fig 8: Total Harmonic Distortion: a)load voltage (b), Source Voltage Fig. 8(a-b) shows the harmonic spectrum of source voltage and load voltage for phase-a. THD of source voltage is 21.54%. With the UPQC there is a significant reduction in load voltage THD from 21.54% to 0.07%. Series APF prevents the harmonics from disturbing the load voltage. V. CONCLUSION This paper describes a control and integration of islanding and reconnection technique of the proposed UPQCmicrogrid-IR in the grid connected micro grid condition. The performance with off-line simulation has been obtained. The results show that the UPQCmicrogrid-IR can compensate the voltage and current disturbance at the Point of Common Coupling during the interconnected mode. In islanded mode, the DG converters only supply the active power. Therefore, the DG converters need not to be disconnected or change their control strategy to keep the MicroGrid operating in any time with any condition. REFERENCES [1] S K Khadem, M Basu, M F Conlon, UPQC for Power Quality Improvement in DG Integrated Smart Grid Network A Review, Int Journal of Emerging Electric Power Systems, Vol. 13(1), 2012, Art 3 [2] X. Yu, A.M. Khambadkone, H. Wang, S. Terence, Control of Parallel- Connected Power Converters for Low-Voltage Microgrid Part I: A Hybrid Control Architecture, IEEE Trans [3] S K Khadem, M. Basu, M.F. Conlon, A new placement and integration method of UPQC to improve the power quality in DG network, Universities Power Engineering Conference [4] A Kahrobaeian, Y Mohamed, Interactive distributed generation interface for flexible microgrid operation in smart distribution systems, IEEE Trans Sustainable Energy, vol.3(2), pp.295-305, 2012 Power Electronics, vol.25 (12), 2010, pp.2962-2970, UPEC, Vol.1, Sept 2013. [5] S. K. Khadem, M Basu and M F Conlon, Harmonic Power Compensation Capacity of Shunt APF and its Relationship to Design Parameters, IET Power Electronics, 2014, Vol 7(2), pp. 418-430 [6] J M Guerrero, J Vasquez, J Matas, M Castilla, Hierarchical Control of Droop-Controlled AC and DC Microgrids-A General Approach Toward Standardization, IEEE Trans IndElectr, vol.58, (1), pp.158-172, 2011 [7] B Han, B Bae, H Kim, S Baek, Combined Operation of Unified Power Quality Conditioner with Distributed Generation, IEEE Trans Power Delivery, vol. 21(1), 2006, pp. 330 338 [8] H. Kim, T. Yu, S. Choi, Indirect current control algorithm for utility interactive inverters in distributed generation systems, IEEE Trans. Power Electronics, vol. 23(3), pp. 1342 1347, May 2008. [9] Rocabert, G.M.S. evedo,.una,. M.. Guerrero,.I Candela,. P. Rodrgue, Intelligent Connection gent for Three-Phase Grid-Connected Microgrids, IEEE Trans Power Electronics, vol.26(10), 2011, pp.2993-3005 [10] Z Yao, L Xiao, Y Yan, Seamless transfer of single-phase grid interactive inverters between grid connected and stand-alone modes, IEEE Trans. Power Electronics,vol.25(6), pp.1597 1603, 2010 [11] S. Chung, A phase tracking system for three phase utility interface inverters, IEEE Trans. Power Electron., vol. 15(3), pp. 431 438, 2000. AUTHORS First Author Harshitha.M R, M-tech in Power System Engineering, Don Bosco Institute of Technology Harshi.havi@gmail.com Second Author Sharmila.R S, AssociateProfessor, Dept. of EEE, Don Bosco Institute of Technology, sharmilabharadwaja@gmail.com Third Author Dr.G C Shivasharannapa,Professor, Dept. of EEE, Don Bosco Institute of Technology, sharusharan@gmail.com Fourth Author Dr. R. Prakash, HOD, Dept. of EEE, Don Bosco Institute oftechnology.

International Journal of Scientific and Research Publications, Volume 6, Issue 8, August 2016 221