Mystery noise in GEO600. Stefan Hild for the GEO600 team. 14th ILIAS WG1 meeting, October 2007, Hannover

Similar documents
Comparison of tuned and detuned Signal-Recycling. Stefan Hild for the GEO-team

Status of GEO600. Harald Lück. for the GEO Team LIGO-G Z. GWADW May06, H. Lück

Experience with Signal- Recycling in GEO600

Commissioning of Advanced Virgo

How to Build a Gravitational Wave Detector. Sean Leavey

Stable Recycling Cavities for Advanced LIGO

The AEI 10 m Prototype. June Sina Köhlenbeck for the 10m Prototype Team

Virgo status and commissioning results

The Virgo detector. L. Rolland LAPP-Annecy GraSPA summer school L. Rolland GraSPA2013 Annecy le Vieux

Advanced Virgo commissioning challenges. Julia Casanueva on behalf of the Virgo collaboration

Control Servo Design for Inverted Pendulum

Arm Cavity Finesse for Advanced LIGO

Alignment control of GEO 600

Thoughts on noise in LISA What do we learn from LPF? M Hewitson LISA Consortium Meeting Paris 13th October 2015

The Florida control scheme. Guido Mueller, Tom Delker, David Reitze, D. B. Tanner

This is a brief report of the measurements I have done in these 2 months.

arxiv: v1 [gr-qc] 10 Sep 2007

Our 10m Interferometer Prototype

DRAFT Expected performance of type-bp SAS in bkagra

7th Edoardo Amaldi Conference on Gravitational Waves (Amaldi7)

Parametric signal amplification

A Thermal Compensation System for the gravitational wave detector Virgo

GAS (Geometric Anti Spring) filter and LVDT (Linear Variable Differential Transformer) Enzo Tapia Lecture 2. KAGRA Lecture 2 for students

Stable recycling cavities for Advanced LIGO

TNI mode cleaner/ laser frequency stabilization system

Introduction to laser interferometric gravitational wave telescope

A high resolution bunch arrival time monitor system for FLASH / XFEL

Beam Diagnostics, Low Level RF and Feedback for Room Temperature FELs. Josef Frisch Pohang, March 14, 2011

Physical model of the LISA Pathfinder differential acceleration measurement and its application to LISA. LISA Symposium 5 September 2016, Zurich

LIGO II Photon Drive Conceptual Design

The VIRGO injection system

Interferometer signal detection system for the VIRGO experiment. VIRGO collaboration

Quantum States of Light and Giants

Testbed for prototypes of the LISA point-ahead angle mechanism

5 Advanced Virgo: interferometer configuration

Installation and Characterization of the Advanced LIGO 200 Watt PSL

A gravitational wave is a differential strain in spacetime. Equivalently, it is a differential tidal force that can be sensed by multiple test masses.

Angular control of Advanced Virgo suspended benches

Results from the Stanford 10 m Sagnac interferometer

Development of Optical lever system of the 40 meter interferometer

LISA and SMART2 Optical Work in Europe

PRM SRM. Grav. Wave ReadOut

VIRGO. The status of VIRGO. & INFN - Sezione di Roma 1. 1 / 6/ 2004 Fulvio Ricci

Fiber Pigtailed Variable Frequency Shifters Acousto-optic products

Development of the accelerometer for cryogenic experiments II

Wavelength Control and Locking with Sub-MHz Precision

Understanding Initial LIGO and Possible Influences on Enhanced LIGO. Sam Waldman and Rai Weiss February 2008

The LTP interferometer aboard SMART-2

Vibration measurement in the cryogenic interferometric gravitational wave detector (CLIO interferometer)

Multiply Resonant EOM for the LIGO 40-meter Interferometer

Optical design of shining light through wall experiments

Modeling and Commisioning of the 10m Prototype Autoalignment System

Back-Reflected Light and the Reduction of Nonreciprocal Phase Noise in the Fiber Back-Link on LISA

FLASH rf gun. beam generated within the (1.3 GHz) RF gun by a laser. filling time: typical 55 μs. flat top time: up to 800 μs

Some Progress In The Development Of An Optical Readout System For The LISA Gravitational Reference Sensor

R. J. Jones Optical Sciences OPTI 511L Fall 2017

RF Locking of Femtosecond Lasers

Using a Negative Impedance Converter to Dampen Motion in Test Masses

The VIRGO detection system

Diffractive gratings. in high-precision interferometry. for gravitational wave detection

PXA Configuration. Frequency range

Thermal correction of the radii of curvature of mirrors for GEO 600

Texas Components - Data Sheet. The TX53G1 is an extremely rugged, low distortion, wide dynamic range sensor. suspending Fluid.

Squeezed light and radiation pressure effects in suspended interferometers. Thomas Corbitt

Noise Budget Development for the LIGO 40 Meter Prototype

R. De Rosa INFN Napoli For the VIRGO collaboration

Physics 309 Lab 2 Faraday Effect

PRACTICAL PROBLEMS INVOLVING PHASE NOISE MEASUREMENTS

Theoretical Approach. Why do we need ultra short technology?? INTRODUCTION:

Picometer stable scan mechanism for gravitational wave detection in space

레이저의주파수안정화방법및그응용 박상언 ( 한국표준과학연구원, 길이시간센터 )

Sub-Millimeter RF Receiver. Sub-Millimeter 19Receiver. balanced using Polarization Vectors. Intrel Service Company

A simple high-sensitivity interferometric position sensor for test mass control on an advanced LIGO interferometer

Designing Optical Layouts for AEI s 10 meter Prototype. Stephanie Wiele August 5, 2008

Mechanical modeling of the Seismic Attenuation System for AdLIGO

CHAPTER 3. Multi-stage seismic attenuation system

SA210-Series Scanning Fabry Perot Interferometer

Evaluation of Scientific Solutions Liquid Crystal Fabry-Perot Etalon

PSD Characteristics. Position Sensing Detectors

LIGO-P R Detector Description and Performance for the First Coincidence Observations between LIGO and GEO

The VIRGO suspensions

SECOND HARMONIC GENERATION AND Q-SWITCHING

SHOCK AND VIBRATION RESPONSE SPECTRA COURSE Unit 4. Random Vibration Characteristics. By Tom Irvine

Optical lever for KAGRA

An Alternative to Pyrotechnic Testing For Shock Identification

LIGO PROJECT. Piezo-Electric Actuator Initial Performance Tests. Eric Ponslet April 13, Abstract

Silicon Light Machines Patents

Added Phase Noise measurement for EMBRACE LO distribution system

Interferometer for LCGT 1st Korea Japan Workshop on Korea University Jan. 13, 2012 Seiji Kawamura (ICRR, Univ. of Tokyo)

CALIFORNIA INSTITUTE OF TECHNOLOGY Laser Interferometer Gravitational Wave Observatory (LIGO) Project

ACOUSTIC MITIGATION STATUS FOR S3

The Pre Stabilized Laser for the LIGO Caltech 40m Interferometer: Stability Controls and Characterization.

Squeezing with long (100 m scale) filter cavities

ISC RF Photodetector Design: LSC & WFS

Advanced Virgo Technical Design Report

Using Frequency Diversity to Improve Measurement Speed Roger Dygert MI Technologies, 1125 Satellite Blvd., Suite 100 Suwanee, GA 30024

Levitated Dipole Experiment

Investigation of Squeezed Light with an Injection Locked Laser

Modeling of Alignment Sensing and Control for Advanced LIGO

Resonance Tube. 1 Purpose. 2 Theory. 2.1 Air As A Spring. 2.2 Traveling Sound Waves in Air

Transcription:

Mystery noise in GEO600 Stefan Hild for the GEO600 team 14th ILIAS WG1 meeting, October 2007, Hannover

Intro: What is mystery noise? There is a big gap between the uncorrelated sum (pink) of all known noise contributions and the actually measured sensitivity (red). Stefan Hild ILIAS WG1 10/2007 Slide 2

Intro: What is mystery noise? (2) Also the fundamental noise contributions, especially thermal noises are far below the current sensitivity. Stefan Hild ILIAS WG1 10/2007 Slide 3

Mystery noise => High Priority Limits the GEO sensitivity between 100 and 800 Hz. Around 200 Hz without mystery noise the sensitivity would be 3 times better. The peak sensitivity (550 Hz) could be improved by about a factor sqrt(2). As long as mystery noise is present, i.e. GEO is not shot noise limited over the major part of the detection band, improvements like increased laser power, DC-readout, squeezing are partly worthless. We need to find the mystery noise! (There is NO other option) Stefan Hild ILIAS WG1 10/2007 Slide 4

How to tackle the mystery noise? Mystery noise Stefan Hild ILIAS WG1 10/2007 Slide 5

How to tackle the mystery noise? Mystery noise Displacement noise Yes / No? Characteristics of the mystery noise Any clues from the observation? Displacement-like or not? Stationary? Related to glitches?... Stefan Hild ILIAS WG1 10/2007 Slide 6

Fundamental noises How to tackle the mystery noise? Projected noises Mystery noise Displacement noise Yes / No? Characteristics of the mystery noise Is the gap real? All projections correct? Are all noises projected? Calculations of fundamental noises correct? Stefan Hild ILIAS WG1 10/2007 Slide 7

How to tackle the mystery noise? Fundamental noises Upconversion Scattered light Projected noises Mystery noise Exotic noises Displacement noise Yes / No? Characteristics of the mystery noise Can we rule out the usual candidates: non-linearly coupling noises? How about exotic noises?... Stefan Hild ILIAS WG1 10/2007 Slide 8

Stefan Hild ILIAS WG1 10/2007 Slide 9

Characteristics of the mystery noise History of the mystery noise Broadband noise (without significant structure /features) Mystery noise is found to be fairly stable over 15 months (within about 25%). Seems to be independent from environmental conditions. Spectrum (roughly): 1/f^2 below 200 Hz, 1/f above 200 Hz Stefan Hild ILIAS WG1 10/2007 Slide 10

Characteristics of the mystery noise Mystery noise is independent of the glirchrate Eventhough we observe strong fluctuations in the glitchrate, the mystery noise stays always constant. Stefan Hild ILIAS WG1 10/2007 Slide 11

Stefan Hild ILIAS WG1 10/2007 Slide 12

Does the mystery noise behave like displacement noise?? If we could find out life would be much easier... Displacement noise Yes / No? If the mystery noise doesn t look like displacement noise: Can rule out all thermal noises Can rule out any noise of the test masses... If the mystery noise looks like displacement noise: We can rule out many technical noises like oscillator phase noise, oscillator amplitude noise, frequency noise... Stefan Hild ILIAS WG1 10/2007 Slide 13

Displacement noise Yes / No? Checking the mystery noise for different Signal Recycling tunings (1) Mystery noise has different shape and level in 1kHz and 550Hz tuning. => Indication: does not look like displacement noise Stefan Hild ILIAS WG1 10/2007 Slide 14

Displacement noise Yes / No? Checking the mystery noise for different Signal Recycling tunings (2) 10-20 myst_350 Hz, August 2007 myst-2006-05-06, 550 Hz myst-2007-06-13, 550 Hz myst-2007-03-12, 550 Hz S tra in [1/s qrt(hz)] 10-21 10-22 Frequency [Hz] 10 3 Mystery noise has same shape and level in 350Hz and 550Hz tuning. => Indication: does look like displacement noise Stefan Hild ILIAS WG1 10/2007 Slide 15

Displacement noise Yes / No? Observation 1: Displacement noise like: YES / NO? Mystery noise has different shape and level in 1kHz and 550Hz tuning. => Indication: does not look like displacement noise. Observation 2: Mystery noise has same shape and level in 350Hz and 550Hz tuning. => Indication: does look like displacement noise. Summary: We cannot decide whether the mystery noise is displacment noise or not. (Perhaps it consists of two different components.) => We have to investigate both: displacement AND non-displacement noises. Stefan Hild ILIAS WG1 10/2007 Slide 16

Stefan Hild ILIAS WG1 10/2007 Slide 17

What do we have to check in terms of noise projections? Projected noises Are the noise projections we do correct? Did we miss to project any relevant noise source? Are the transferfunctions used for the projections correct? Stefan Hild ILIAS WG1 10/2007 Slide 18

Projected noises Which noise projections are relevant for the mystery noise frequency range? Oscillator phase noise Oscillator amp noise Laser power noise Frequency noise Detection dark noise Two main suspects: OPN: shape would fit and is not too far from limiting. PR-noise: Was never really understood (In-loop, high gain) Stefan Hild ILIAS WG1 10/2007 Slide 19

Projected noises OPN investigations 1: 2f local oscillator Nominal setup: Signal passes optical system, while LO is electrically. Using 2f signal from darkport (devided by 2) as LO => Signal and LO travel the same path. Amplitude [V/ Hz] 10-4 X: 1185 Y: 0.0005243 Suppression of OPN Spectrum plot using Hanning window 03: G1:LSC_MID_EP-P_HP 04: G1:LSC_MID_EP-Q_HP P quadrature using the 2 signal Amplitude [V/ Hz] 10-1 Spectrum plot using Hanning window 10-2 10-3 Using 2f LO gives same sensitivity 01: G1:LSC_MID_EP-P_HP 02: G1:LSC_MID_EP-Q_HP P quadrature using 2f signal X: 1185 Y: 4.322e-005 10-4 10 3.06 10 3.08 10 3.1 10 3.12 10 3.14 10 3.16 Frequency [Hz] 10-5 10 1 10 2 10 3 Frequency [Hz] Indication: mystery noise is not related to OPN Stefan Hild ILIAS WG1 10/2007 Slide 20

Projected noises OPN investigations 2: wire instead of MI Idea: Replacing the IFO by a wire should give lower limit of OPN. Replacing: EOM, IFO and photodiode by a good wire Stefan Hild ILIAS WG1 10/2007 Slide 21

Projected noises OPN investigations 2: wire instead of MI Wire projection gives a noise (yellow trace) close to shot noise. => Mystery noise gap gets smaller. Stefan Hild ILIAS WG1 10/2007 Slide 22

Frequency noise projection: A smoking gun? Projected noises The change of the mystery noise from 550Hz to 1kHz tuning looks suspiciously similar to the change of the frequency noise transfer function. Stefan Hild ILIAS WG1 10/2007 Slide 23

Projected noises Frequency noise projection (2) Main problem of this loop: In-loop measurement with high gain. One important experiment is to set up an out-of-loop photodiode. Can rule out any sensing noise of the PR-loop. Left over: Any frequency noise on the light (4 above detection noise) could be the mystery noise. Stefan Hild ILIAS WG1 10/2007 Slide 24

Projected noises Noise projections summary improved existing projections added a few missing projections checked for any non-linearities in the transferfunctions (compared swept sine and random noise measurements) the gap got smaller, but is still there... We believe that OPN is not causing the mystery noise. We believe that the mystery is not related to magnetic fields. We believe that frequency noise is still a good candidate. Can rule out the electronics (?) Can rule out the detection Frequency noise on the light could explain the mystery noise. Stefan Hild ILIAS WG1 10/2007 Slide 25

Stefan Hild ILIAS WG1 10/2007 Slide 26

Fundamental noises Checking correctness of shot noise (1) Attenuation experiment: G1:DER_DATA_H fs = 16384 : 240s, nfft=16384, nolap=0.50, enbw=1.5, navs=479 10-20 attenuated HPD path reference day reference night Expected sensitivity decrease found (all frequencies) Amplitude [V/ Hz] 10-21 Nominal light power 10-22 10 2 10 3 Frequency [Hz] Attenuated the detected light at main photodetector. The sensitivity measured matches the shot noise calculations. Stefan Hild ILIAS WG1 10/2007 Slide 27

Fundamental noises Checking correctness of shot noise (2) Shot noise simulations using FINESSE: Stefan Hild ILIAS WG1 10/2007 Slide 28

Fundamental noises Revisiting the thermal noise calculations The Glasgow group (Reid, Rowan, Hough) revisited all thermal noise calculations: Draft version of a nice and detailed document is available now (includes all equations, references and used parameters). Stefan Hild ILIAS WG1 10/2007 Slide 29

Fundamental noises Revisiting the thermal noise calculations The Glasgow group (Reid, Rowan, Hough) revisited all thermal noise calculations: Draft version of a nice and detailed document is available now (includes all equations, references and used parameters). Coating TN now distingished in thermorefractive, thermoelastic and brownian. Brownian is the dominant contribution. Didn t change. Substrate Brownian noise. Changed slope and level. Now lower, but less steep. BS thermorefractive noise. Now 3.5 times higher. => Dominating TN for frequencies up to 1.5kHz. Stefan Hild ILIAS WG1 10/2007 Slide 30

Fundamental noises New thermal noise calculations Revisited thermal noises cannot explain the mystery noise. Stefan Hild ILIAS WG1 10/2007 Slide 31

IDEA: Increased thermal noise due to excess damping? Testmass is close to touching its catcher There might be conditions where additional damping is caused Could such damping reduce the Q of the modes and therfore increase the thermal noise??? Fundamental noises (Famous Livingston Earthquake stops???) We tried to take photographs of the testmasses. Due to the restricted view angles for 4 of the 5 main optics we cannot say how far they are from their catchers. Stefan Hild ILIAS WG1 10/2007 Slide 32

Stefan Hild ILIAS WG1 10/2007 Slide 33

Upconversion Is there any indication for upconversion? Scatter plots: low freq signal vs sensitivity Used low-freq channels: Seismic, MI differential lenght, MI differential auto-alignment Usually no indication of significant upconversion So far only a single data set showed indication for upconversion (0.1 0.3 Hz) from MID long and MID AA. Stefan Hild ILIAS WG1 10/2007 Slide 34

Stefan Hild ILIAS WG1 10/2007 Slide 35

Scattered light Scattering Overview External Scattering (outside the vacuum) All interferometer ports Detection bench In-vacuum-Scattering Scattered light from catchers Scattering inside the central cluster Small angle scattering in the folded arms Grating -scattering from coating defects Stefan Hild ILIAS WG1 10/2007 Slide 36

Scattered light All interferometer ports External Scattering We did 2 complete rounds of filter / blocking experiments for all ports outside the vacuum. => No limiting scattering observed Spectrum plot using Hanning window Detection bench Ruled out scattering from HPD-path and quadrant path by using an opto-mechanical phase shifter. Amplitude [V/ Hz] 10-19 10-20 10-21 Scattered light reduction of the o.m. phase shifter 2007-06-29 12:34:10 - scrambler off 2007-06-29 12:37:00 - scrambler off 2007-06-29 12:38:15 - scrambler active 2007-06-29 12:35:50 - scrambler active 2007-06-29 03:27:00 - night ref, no scattering 10 2 10 3 Frequency [Hz] Stefan Hild ILIAS WG1 10/2007 Slide 37

Scattered light Scattered light from the catchers (1) Light on the catchers from small angle scattering. Catchers are not seismically isolated Light scattered back into IFO mode can harm sensitivity Stefan Hild ILIAS WG1 10/2007 Slide 38

Scattered light Scattered light from the catchers (2) Preliminary. Uncertanties= f_cat and X_cat Displacement noise from scattering Displacement of catcher Stefan Hild ILIAS WG1 10/2007 Slide 39

Scattered light Scattered light from the catchers (3) Seismic excitation of catchers => no change in h(t) => ruled out scattering from catchers However, probably not far from limiting => preparing baffles Amplitude [V/ Hz] 10-17 10-18 10-19 10-20 10-21 03: G1:DER_DATA_H fs = 16384 : 60s nfft=81920, nolap=2.50, enbw=0.3, navs=23 new viewport, with flowbox from 2007-06-14 14:18:00 - new viewport, without flowbox from 2007-06-14 14:20:00 - No seismic excitation Seismic excitation 10 2 10 3 Frequency [Hz] Stefan Hild ILIAS WG1 10/2007 Slide 40

Scattered light Scattering inside the central cluster (involving tank walls) Idea: We observe a lot of scattered light inside the central cluster. Some of the stray light from the tank wall might mind find the way to the detection port Ruled out by external shaking of the tank walls: 10-2 shaking the tank walls no influence to mystery noise 10-3 10-20 Amplitude [V/ Hz] 10-4 Amplitude [V/ Hz] 10-21 10-5 10 2 10 3 Frequency [Hz] 10-22 10 2 10 3 Frequency [Hz] Stefan Hild ILIAS WG1 10/2007 Slide 41

Scattered light IDEA: Small angle scattering in the folded arms Some light hitting the far mirrors is directly scattered back. Can be ruled out as mystery noise: Far mirrors only move a few microns (rms) Mirrors are isolated by triple pendulum Stefan Hild ILIAS WG1 10/2007 Slide 42

Scattered light Grating -scattering from coating defects Inverted photographs of a far mirror (IFO is flashing) IDEA: Coating defects can be described as grating. Scattering path: Coating defect => tank wall => Coating defect Beam jitter would cause phase noise analogous to a grating. Not completely understood so far. However, could be ruled out by shaking experiments. Stefan Hild ILIAS WG1 10/2007 Slide 43

Scattered light Scattering Overview External Scattering (outside the vacuum) All interferometer ports Detection bench In-vacuum-Scattering Scattered light from catchers Scattering inside the central cluster Small angle scattering in the folded arms Grating -scattering from coating defects We think we ruled out NEARLY ALL scattered processes we can think of. Stefan Hild ILIAS WG1 10/2007 Slide 44

Stefan Hild ILIAS WG1 10/2007 Slide 45

Exotic noises Controlled increase of pressure inside the vacuum system (1) Is the mystery noise caused by residual gas pressure? Experiment: Closed all valves to turbo pumps. Pressure at all sensors increased by about a factor 30. Stefan Hild ILIAS WG1 10/2007 Slide 46

Exotic noises Controlled increase of pressure inside the vacuum system (2) Spectrum plot using Hanning window No effect seen in sensitivity. Can ruled out residual pressure as cause of the mystery noise. Amplitude [V/ Hz] 10-19 10-20 10-21 2007-07-31 13:30:00-2007-07-31 12:30:00 2007-07-31 11:30:00 2007-07-31 10:30:00 2007-07-31 14:30:00 2007-07-31 15:30:00 10 2 10 3 Frequency [Hz] Stefan Hild ILIAS WG1 10/2007 Slide 47

Exotic noises Effects from test mass charging? Charges on test masses Measured positive charging of testmasses Discharged by using a UV-lamp (electrons are freed from ESD electrodes) BEFORE 100V AFTER 15V Problem: charges on test masses effect out calibration. However, we believe the charges did not harm the sensitivity. Stefan Hild ILIAS WG1 10/2007 Slide 48

Exotic noises Barkhausen noise What else is left over?? Unlikely: Only MSR and MPR have magnets directly at the mirror Maybe the mystery noise is a new type of noise (GEO specific): ESDs? Signal-Recycling? Monolithic suspensions? Folded arms? High power in BS substrate? High PR gain? Stefan Hild ILIAS WG1 10/2007 Slide 49

Noise projection to h 2007-10-15 02:10:00 Exotic noises Does the mystery noise depend on the optical power?? AS D [h/s qrt(hz)] 10-20 10-21 MID AA FB Rot MID AA FB Tilt SR longitudinal noise Oscillator phase noise Oscillator amplitude noise Laser amplitude noise PR error Magnetic field RF noise Dark noise Model Shot 550Hz Sum of the noise H- deg 70 (good time) 10-22 10 2 10 3 Frequency (Hz) Using only 66% of nominal optical power reduces the gap. Above 300 Hz the mystery noise is smaller with low power, while below 300 Hz it stays constant. Another indication that we are looking for more than one mystery noises. Stefan Hild ILIAS WG1 10/2007 Slide 50

Additional Slides Stefan Hild ILIAS WG1 10/2007 Slide 51