Experimental Study of Two Way Half Slab Precast Using Triangular Rigid Connection of Precast Concrete Component

Similar documents
Composite Sections. Introduction BETON PRATEGANG TKS Session 10: 2015/4/27

EXPERIMENTAL AND ANALYTICAL STUDIES ON THE STRENGTHENING OF RC FRAMES

The Behaviour Of Round Timber Sections Notched Over The Support On The Tension Face. Justin Dewey

Keywords: Bracing bracket connection, local deformation, selective pallet racks, shear stiffness, spine bracings.

Nonlinear behavior of Reinforced Concrete Infilled Frames using ATENA 2D

Design of structural connections for precast concrete buildings

Index Terms: Lathe waste concrete; Shear and bending; Shear strength; Stirrups; Simply supported beams.

Innovative composite dowel for steel concrete composite bridges. Neil Westmacott, Wolfram Schwarz

Cyclic Response of Dowel Connections in Precast Structures

Prof. Sudhir Misra, Dept of CE (PI) Prof. Samit Raychaudhari, Dept of CE (Co PI) Dr. KK Bajpai, Dept of CE (Co PI)

TECHNICAL MANUAL. TERADOWEL and ULTRADOWEL. Reliable Dowel System for Floor Joints

Dowel connections in laminated strand lumber

DOWEL ACTION OF TITANIUM BARS CONNECTING MARBLE FRAGMENTS AT DIFFERENT ANGLES

The predictive model for strength of inclined screws as shear connection in timber-concrete composite floor

MODELLING OF CONCRETE PAVEMENT DOWEL-SLAB INTERACTION

Structural Strength of Lapped Cold-Formed Steel Z-Shaped Purlin Connections with Vertical Slotted Holes

Experimental Study on Pile Groups Settlement and Efficiency in Cohesionless Soil

AMTS STANDARD WORKSHOP PRACTICE. Bond Design

LABORATORY EVALUATION OF CONCRETE-FILLED GFRP DOWELS IN JOINTED CONCRETE PAVEMENTS

Dowels for the 21st Century

EFFECT OF YARN CROSS-SECTIONAL SHAPES AND CRIMP ON THE MECHANICAL PROPERTIES OF 3D WOVEN COMPOSITES

Development of a New-Generation Dowel and Screw Combination 2014 International Crosstie and Fastening System Symposium Urbana, IL, USA 3 June 2014

ANALYSIS OF LATERAL STIFFNESS FOR INFILLED FRAME WITH OPENING

PRECAST CONCRETE STRUCTURES

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 04, 2016 ISSN (online):

Effect of Masonry Infills on Seismic Performance of RC Frame Buildings

EXPERIMENTAL INVESTIGATION OF FATIGUE BEHAVIOUR IN COMPOSITE BOLTED JOINTS

Experimental Study on the Seismic Behavior of Retrofitted Concrete Infill

Connection and performance of two-way CLT plates

Anti-check bolts as means of repair for damaged split ring connections

Combined stress analysis of mitered spline furniture joints under diagonal loading

Moment-Resisting Connections In Laminated Veneer Lumber (LVL) Frames

ANALYSIS OF PILE-RAFT FOUNDATIONS NON- RESTED AND DIRECTLY RESTED ON SOIL

PERFORMANCE OF COMPOSITE SHEAR WALL PANEL OF LVL AND GRC BOARD

Double Shear Testing of Bolts

STRUCTURAL TIMBER DESIGN

NALYSIS OF STABILIZING SLOPES USING VERTICAL PILES

Mechanical behavior of fiberglass reinforced timber joints

Dynamic Analysis of Infills on R.C Framed Structures

Behaviour of fibre reinforced composite beams with mechanical joints

A STUDY ON PATTERN DAMAGE OF FINGER JOINTS IN BAMBOO LAMINATED BEAMS

INFLUENCE OF PILES ON LOAD- SETTLEMENT BEHAVIOUR OF RAFT FOUNDATION

Influence of bending and dowel action on the interface bond in RC beams strengthened with FRP sheets: An experimental investigation

Moment Resisting Connections for Load Bearing Walls

Slip and yield resistance of friction type of high strength bolted connections with over-sized holes

Load-carrying capacity of timber frame diaphragms with unidirectional support

Unit 8 Precast Concrete

Development of an Embedded Sensor Holder for Concrete Structures Monitoring

A novel procedure for evaluating the rotational stiffness of traditional timber joints in Taiwan

State-of-the-art Report On FULL-DEPTH PRECAST CONCRETE BRIDGE DECK PANELS (SOA )

DYNAMIC CHARACTERISTICS OF A BRIDGE ESTIMATED WITH NEW BOLT-TYPE SENSOR, AMBIENT VIBRATION MEASUREMENTS AND FINITE ELEMENT ANALYSIS

SEISMIC BEHAVIOR OF BEAM-TO-COLUMN DOWEL CONNECTIONS: NUMERICAL ANALYSIS VS EXPERIMENTAL TEST

EFFECTS OF GEOMETRY ON MECHANICAL BEHAVIOR OF DOVETAIL CONNECTION

Lawrence A. Soltis, M. and Robert J. Ross, M. 1

PRO LIGNO Vol. 11 N pp

Comparative Evaluation of Resistance Made Simple Shear Connection with Bolts and With Welding

Ultrasonic Transmission Characteristics of Continuous Casting Slab for Medium Carbon Steel

Precast Concrete Pavement Background Concepts. Project 1517 FHWA, CTR & TxDOT Gary Graham November 15, 2001

Korean standards of visual grading and establishing allowable properties of softwood structural lumber

Sliding shear capacities of the Asymmetric Friction Connection

TITLE: BEHAVIOUR OF FERROCEMENT COLUMNS WITH DIFFERENT LOCATION OF MESH LAYERS

Effect of Braces on Framed Machine Foundation for Turbo Generator

Flanged Dowel Box. Load Transfer System INDUSTRIAL SLAB ON GROUND

Shear Capacity of Dowelled Mortise and Tenon in Tropical Timber

Cast-in Ferrule Connections Load/Displacement Characteristics in Shear

Module 10 : Improvement of rock mass responses. Content

Failure of Engineering Materials & Structures. Code 34. Bolted Joint s Relaxation Behavior: A FEA Study. Muhammad Abid and Saad Hussain

Glass Fiber Reinforced Polymer (GFRP) Dowel Bars - Aslan 600

Glued laminated timber beams repair.

Determining the transverse shear stiffness of steel storage rack upright frames

Finite Element Study of Using Concrete Tie Beams to Reduce Differential Settlement Between Footings

K L Rakshith, Smitha, International Journal of Advance Research, Ideas and Innovations in Technology.

Hazlan Abdul Hamid* & Mohammad Iqbal Shah Harsad

Experimental investigation of the behaviour of pinned beam to column connections to pure shear monotonic and cyclic excitation

Preliminary study of the vibration displacement measurement by using strain gauge

JVI Vector Connector

Optimum Design of Nailed Soil Wall

Open Access Push-Pull Interface Connections in Steel Frames with Precast Concrete Infill Panels

Dowel type joints Influence of moisture changes and dowel surface smoothness. Erik Serrano and Johan Sjödin, Växjö University, Sweden

Prying of a Large Span Base Plate Undergoing a Moment Load Applied by a Round Pier

SIMPLIFIED DESIGN PROCEDURE FOR GLUED-LAMINATED BRIDGE DECKS

ASSESSMENT OF COMPOSITES REINFORCED WITH INNOVATIVE 3D WOVEN HOLLOW FABRICS

SCREWS WITH CONTINUOUS THREADS IN TIMBER CONNECTIONS

Evaluation of the Partial Compressive Strength according to the Wood Grain Direction* 1

Dowel. Design. Performance-Based World of Concrete Official Show Issue. Lift-truck design changes require a new look at joint durability

Numerical Modeling of Grouted Soil Nails

A Solution to Cracking and Stresses Caused by Dowels and Tie Bars

Hours / 100 Marks Seat No.

TECHNICAL MANUAL. OPTIMAJOINT Free Movement Joint. Free Movement Joint System for Heavy Traffic

FULL SCALE FAILURE TESTING OF A REINFORCED CONCRETE BRIDGE: PHOTOGRAPHIC STRAIN MONITORING

Modelling of Rebar and Cable Bolt Behaviour in Tension/Shear

Experimental and numerical study of nailed laminated timber elements for in plane and transverse loading

Effect of Infill Walls on RC Framed Structure

VIBRATIONAL TESTING OF A FULL-SCALE PILE GROUP IN SOFT CLAY

CODE FORMULA FOR THE FUNDAMENTAL PERIOD OF RC PRECAST BUILDINGS

Development of Wooden Portal Frame Structures with Improved Columns

Strength of Material-I (CE-207)

NUMERICAL ANALYSIS OF SCREW ANCHOR FOR CONCRETE

In situ Roughness Monitoring Method Using Fiber Optic Vibration Sensors

Erstantie 2, FIN Villähde Tel , Fax

Transcription:

International Journal of Applied Engineering Research ISSN 973-462 Volume 12, Number (17) pp. 744-74 Experimental Study of Two Way Half Slab Precast Using Triangular Rigid Connection of Precast Concrete Component Djoko Irawan 1, Data Iranata 1 and Priyo Suprobo 1 1 Department of Civil Engineering, Institut Teknologi Sepuluh Nopember, Indonesia. Abstract Precast concrete half slab system, which consists of precast concrete at the bottom part and cast-in-site concrete at the overtopping, is widely used as floor slab and commonly behave as a one-way slab. However, the problems occur when the precast half slab is designed as the two-way slab system. In this system, the connection of between precast concrete slabs should able to handle the two-way moment of the whole panel, without causing any significant damages. Hence, an innovative rigid connection between precast concrete slab components in two-way half slab system is presented in this paper. The objectives of this research are to conduct the experimental study for proposed connection between precast concrete slab components that behave as two-way half slab system. The 2 mm 2 mm size of samples are performed using the triangular shape of the rigid connection between precast concrete slabs. The test is conducted using mid-span concentrated loading-unloading up to failure condition. The test results are observed and verified with the response of monolith reinforced concrete slab system using the same loading pattern. The verification results show that proposed half slab system are able to withstand the two-way moment loading. Although the carrying capacity is still slightly lower than the monolith reinforced concrete slab system, the proposed half slab system is able to apply as the structural component. Keyword: half slab, precast concrete, reinforced concrete, rigid connection, loading-unloading INTRODUCTION The precast concrete half slab is a structural slab system that consists of two different concrete type at the half bottom and the top part of the slab. The bottom part of the slab is made up of the precast concrete component, while the top part is contained of cast-in-site concrete material that so-called overtopping, as presented in Fig.1. Generally, precast concrete half slab system is acting limited as one-way slab only (l y/l x > 2), which is the primary moment loading is acting parallel to the connection between precast concrete components. Therefore, since such connection only resists the minor moment loading, the simple connection is commonly applied between the precast concrete components (as shown in Fig.2), as presented by Wijanto and Takim [1]. However, the problems occur when the precast half slab is designed as the two-way slab system. Since the moment loading act in both X and Y direction, the connection between the precast concrete components should be able to handle the acting moment in the corresponding direction. Otherwise, the crack damages will occur along the corresponding direction. The real case of port design that using the simple connection for two-way precast concrete half slab system is presented by Irawan et al [2]. Fig.3 shows the simple connection of the precast concrete slab component that applied in the port design. Furthermore, the crack that occurs in the bottom part of the slab due to the lacking capacity of the precast connection is depicted in Fig 4. Concrete crack only occurs parallel to the connection between precast concrete slabs. This phenomenon indicates that the simple connection between precast concrete slabs cannot resist the moment loading to the corresponding direction. Hence, it is necessary to develop the rigid connection that applied in this connection system that can withstand the corresponding moment loading. Figure 1. Half Slab Precast Concrete System Figure 2. The simple connection is commonly applied between the precast concrete components Figure 3. The simple connection at the bottom part of half slab precast 744

International Journal of Applied Engineering Research ISSN 973-462 Volume 12, Number (17) pp. 744-74 Many studies about the connection of precast concrete half slab have done previously by researchers. Hieber et al. [3] presented the interlocking connection that able to withstand the shear loading. Hence, the slab could be performed as diaphragm appropriately. Kim and Shim [4] investigated the performance of pre-tensioned half slab in the transverse direction and used the looping connection in the longitudinal direction. Kim and Shim [] also investigated the crack width of half precast slab using looping connection between precast components. Using precast concrete also can reduce operation time substantially comparing to cast in situ concrete. Moreover, Yardim [6] proposed the connection for a precast thin panel that acts as composite slabs for the permanent framework in a residential building. Siswosukarto [7] proposed semi-precast slab as an alternative method to promote the green construction residential house project. Research about the flexure-shear behavior of precast concrete deck panels with cast-in-place concrete topping is also performed by Dowell. et al [8]. The failure prediction of the panel is analyzed using modified. However, this study only focused for the slab in one direction. Additionally, Santos and Julio, [9] has studied about horizontal friction between old and new concrete slab in half precast system. The load transfer mechanism at the concrete to the concrete interface is determined by several factors, such as cohesion behavior, friction coefficient, and dowel action. Lee at al [] also studied about deflection of Reinforced Concrete Half Slab. Vakhsouri, [11] studied about the length of reinforcement adjacent to the crack where the compatibility of strain between the steel and concrete is not maintained because of partially bond breakdown and slip. However, most of those previous study is limited for one-way half slab precast system. Figure 4. The crack that occurs at the bottom part of two ways half slab precast Several types of research about two-way slab have already done by Tezuka [12] who examined experimentally about half - precast waffle slab for long spans. Moreover, Moldovan and Mathe [13] also have studied two-way waffle slab with posttensioning pre-stressed. Furthermore, D. Fall et al [14] has studied analytically about two-way slab using steel fibers. Other studies of two-way slab also have done by Kim et al [], who studied about flexure strengthening of the two-way slab by using CFRP. Gouverneur and Taerwe, [16] studied strain and crack development in continuous reinforced concrete slabs subjected to catenary action. However, all of those researchers only for the full-depth two-way slab. Whereas, for two-way half slab precast studies are still very limited perform by researchers. Based on those previous studies, preliminary experimental study about precast concrete half slab has performed by Irawan et al [2], which proposed the semi-rigid connection as shown in Fig.a to c. The 8 mm mm size of the precast concrete half slab was presented as a specimen. The total thickness of the slab was mm, which is divided into 3 mm thickness of precast concrete and mm of overtopping concrete. The specimen was set up as simply supported at two sides of the slab and subjected to the pure bending static loading along the corresponding direction of the connection. Hence, the slab specimen behaved as a oneway slab and the response of the connection that subjected to the bending loading along the corresponding direction can be obtained and observed. A A 8 cm Over topping Precast Precast cm 3 cm cm cm Section A - A Figure a The half slab precast model of preliminary study 74

International Journal of Applied Engineering Research ISSN 973-462 Volume 12, Number (17) pp. 744-74 B B 8 cm MONOLIT cm cm Section B - B Figure b The monolithic slab model of preliminary Study LOAD Specimen cm cm cm cm cm Figure c. Experimental set up of preliminary study Based on the experimental result, which presented in Table 1, it was showed that the capacity of proposed precast concrete half slab to resist the cracking moment was 16% lower than monolith system. Therefore, to improve and increase the capacity of the precast concrete half slab, this paper present experimental study for proposed rigid connection between precast concrete slab components in two-way half slab system. 7. 7. 6.2 9. 12.6 2. 6. 7. 9. 9. 2. 2.. 7. 7. -. Table 1. Comparison P crack and M crack between monolithic slab and slab with connection 2. RESEARCH METHOD This experimental study present 2 mm 2 mm size of the specimen using the rectangular shape of the rigid connection between precast concrete slabs. The total thickness of the proposed concrete half slab is mm, which is divided into 1 mm thickness of precast concrete and 8 mm of overtopping concrete. Moreover, in order to prevent slip between precast concrete and overtopping, several shear connectors are added to its interface. Furthermore, the simply supported at four sides of the precast concrete half slab are applied. The detail experimental setup is illustrated in Fig. 6a and 6b. 2. 7. 74.32 7.. 8.9.. 7.9 4.62 3.91 12. 7.... 7. - 8 - Figure 6a. Half slab precast model with 7.. 12. 12. 7. 7. 7... 7. 7.. 8. 3.7 12. 746

International Journal of Applied Engineering Research ISSN 973-462 Volume 12, Number (17) pp. 744-74 B A mm LOAD mm 2 Strain Gauge-TO LVDT-V 9 9 Strain Gauge-BO Figure 7. Experimental loading (Actual) 2 Strain Gauge TI Steel Rebar Strain Gauge BI Strain Gauge R-left Strain Gauge R-right Strain Gauge CON LVDT-Deflection 7 Figure 6b. Experimental setup of half-slab precast with Additionally, the test was conducted using mid-span concentrated loading-unloading up to failure condition, which is based on ACI 437R-3 [17] and presented in Fig. 7. The loading-unloading scheme is contained in three cycles, there are an elastic condition, concrete cracking, and plastic condition. Thus, the realistic behavior of two-way precast concrete half slab can be obtained and observed clearly. The results of the test are verified with the response of monolith reinforced concrete slab system (as shown in Fig. 8a and 8b), which also using the same loading pattern. In addition, the material properties of the specimens are presented in Table 2. Table 2 Material Properties SLAB COMPONENT Compressive Strength fc' (Mpa) Monolithic Slab Monolithic Slab 46.9 Half Slab Overtopping 46.9 Precast 49.2 B 9 Figure 8a Monolithic model A mm Load mm 9 2 Strain Gauge TO Strain Gauge BO Strain Gauge CON LVDT To observe the detail response such as strain and displacement, the specimen should equip by appropriate sensor component to measure the deformations. In this study, the sensor equipment that applied in the specimen is rebar and concrete strain gauge, an also LVDT that applied in both X, Y and Z direction. The detail location of the sensor equipment that applied in the specimen is presented in Fig. 9a to 9c. 2 Strain Gauge TI Strain Gauge BI Strain Gauge CON LVDT Figure 8b. Experimental setup of monolithic model Steel Rebar 747

International Journal of Applied Engineering Research ISSN 973-462 Volume 12, Number (17) pp. 744-74 Strain Gauge CON Figure 9a Strain gauge position in specimen Transducher X Transducher Y Figure 9b Transducer / LVDT position on monolithic model Strain Gauge R kr Transducher X Transducher Y Figure 9c Transducer / LVDT position in half slab precast with RESULT AND DISCUSSION Transducher Z Strain Gauge R kn Transducher Z Strain Gauge Strain Gauge Strain Gauge Strain Gauge The response of the specimen that observed this experimental study is consist of displacement both in X, Y, and Z direction; tension and compression strain of reinforcing steel bar width of concrete crack and also crack pattern. The detail observation results, as well as the discussion, is presented as follows. a. Observation of Load Displacement Relationship Monitoring of displacement conducted using LVDT in both X, Y and Z direction which the result is presented in the data logger. Since the LVDT is installed and placed at the center of the span (Fig. 9b, and 9c), the displacement that observed in this study is only limited at the corresponding location. The relationship of load versus displacement curve that observed in this study is presented in Fig. to Fig for X, Y and Z direction, respectively. For the lateral displacement in X and Y direction, as shown in Fig. to Fig 13, respectively, the value occur after the concrete crack has happened. Before concrete crack has occurred, the slab still remains in elastic condition. Which the slab still deflect simultaneously and satisfy the plain remain plain condition. The displacement curve at X direction of the proposed Half Slab Model showed as a tri-linear curve. The first change is happened due to the first crack of the concrete, and the second change is happened due to crack that occurred in the vertical interface between precast and cast-in-situ concrete. While for the monolithic concrete slab, the displacement curve in the X direction is still as a bilinear curve, which means the curve change is only due to the concrete crack that happened at the center of the span. For the displacement at Y direction, both Monolithic Monolithic and Half Slab Model with Triangular Connection has bi-linear displacement curve. This happened because in proposed Half Slab Model with Triangular Connection, the discontinuity between precast concrete only at X direction. Thus, the behavior at the Y direction of both Monolithic Model exactly the same. Furthermore, to obtain the cracking loading of the specimen it is also necessary to consider the deflection at Z direction. Since the loading is applied in the corresponding Z direction, the response in this direction is determined the capacity of the specimen. Based on the observation results, it is shown that the value of crack loading for each specimen, as seen in Fig 14 to, show that the proposed Half Slab Model has crack loading 17.9 % lower than the monolithic concrete slab. This happens because the proposed Half Slab Model with Triangular Connection has two different concrete components, such as precast concrete and cast in situ concrete. The interface between those components is becoming the discontinue part that will decrease the capacity of the concrete specimen. Deformation LVDT-X - Half Slab Model with Triangular Connetcion 22.3 14.2.94 (2.).6-2. 4. 6. Deformation LVDT-X Half Slab Model Deformation LVDT -X (mm) Figure. Deformation-X vs Load of monolithic model 748

International Journal of Applied Engineering Research ISSN 973-462 Volume 12, Number (17) pp. 744-74 Deformation LVDT-X - Monolithic Model Deformation LVDT-X 16.3 Monolithic Model Deformation LVDT-X (mm) (2.). - 2. 4. 6. Figure 11. Deformation-X vs Load of half slab precast with Deflection Half Slab Model 14.2 -.39 1. 2. Deflection - Half Slab Model Deflection (mm) Figure. Deflection vs Load of half slab precast with Figure 12. Deformation-Y vs Load of monolithic model Figure 13. Deformation-Y vs Load of half slab precast with Deflection - Monolithic Model 16.3 Deflection - Monolithic Model -.26 1. 2. Deflection (mm) Figure 14 Deflection vs Load of monolithic model b. Observation of Load Rebar Stress Relationship Monitoring of rebar strain conducted using strain gauge in both X and Y direction which the result is presented in the data logger. The strain gauge is installed and placed in both tension and compression reinforcing steel bar. The relationship of load versus stress curve for both tension and compression reinforcing steel bar that observed in this study is presented in Fig. 16 to Fig. 23, respectively. The response of the steel bar is similar with the concrete displacement. The rebar that located in the X direction of the proposed Half Slab Model has a tri-linear curve. Again, this happened due to the discontinuity between precast concrete components. The first change of the tri-linear curve is happened due to the first crack of the concrete slab, and the second change is happened due to crack that occurred in the vertical interface between precast and cast-in-situ concrete. Stress BO - Monolithic Model 16.3 Stress BO - Monolithic Model 18.8 -... Figure 16 Stress-BO vs Load of monolithic model Stress BO - Half Slab Model 14.2 27. -. 4. Stress BO - Half Slab Model Figure 17 Stress-BO vs Load of half slab precast with 749

International Journal of Applied Engineering Research ISSN 973-462 Volume 12, Number (17) pp. 744-74 Fig. 16 and Fig. 17 show the relationship between load and stress that occurred in the BO strain gauge. BO strain gauge installed on the bottom concrete reinforcement outer layer, indicating that the stress of bottom reinforcing steel of Monolithic Model and B. The relationship curve of load versus stress is linear-shaped before cracked. After the concrete has cracked, the movement of the backbone of the stress curve still linear but the slope of the curve has already changed. BO stress value for the Monolithic Model at the beginning of the crack is 18.8 Mpa and Half Slab Model is 16. Mpa. Furthermore, for BI strain gauge, which installed on the bottom concrete reinforcement inner layer, has a trend similar to the BO strain gauge, but the value is smaller than of BO stress. The value of BI stress at the beginning of the crack is equal to 16.6 Mpa at 16.3 ton load for Monolithic Model and 11.87 Mpa at 14.2 ton load for Half Slab Model with Triangular Connection The relationship of load versus the value of BI stress can be seen in Fig. 18 to 19. This happens due to the shifting position of the neutral axis is getting to the top fiber. Furthermore, TI strain gauge has a trend similar to the TO strain gauge, but the value is smaller than of TO stress. TI stress value at the beginning of the crack is equal to -16.4 Mpa at 16.3 ton load for Monolithic Model and -8.4 Mpa at 14.2 ton load for Half Slab Model with Triangular Connection. Stress TO - Monolithic Model -. 16.3-16.4-4.4-4. 24.4 Stress TO-Monolithic Model -6. Stress BI - Monolithic Model Figure Stress-TO vs Load of monolithic model 16.3 16.6 -. 4. Stress BI - Monolithic Model Figure 18 Stress-BI vs Load of monolithic model Stress TO - Half Slab Model 22.3 14.2 Stress TO - Half Slab Model Stress BI - Half Slab Model -.2 -.. -. -4. -6. 14.2 11.87 -... Stress BI -Half Slab Model Figure 21 Stress-TO vs Load of half slab precast with Figure 19 Stress-BI vs Load of half slab precast with The relationship of load versus stress value of TO and TI can be seen in Fig. to Fig. 23. TO strain gauge which is installed on the upper concrete reinforcement outer layer, indicating that the stress of upper reinforcing steel of Monolithic and half slab model. Stress that occurs in reinforcement is the compression stress. At the beginning of the crack, the stress of reinforcement in Monolithic Model is -16.4 Mpa and for Half Slab Model is -.2 Mpa. The value of stress will continue to increase if the load is increased. But at the certain load, acceleration of the increasing stress will decrease. Figure 22 Stress-TI vs Load of monolithic model 7

International Journal of Applied Engineering Research ISSN 973-462 Volume 12, Number (17) pp. 744-74. Stress TI - Half Slab Model -8.4 -. 22.3 14.2 -. -4. Stress TI - Half Slab Model -6. Strain R left - Half Slab Model 14.2 Strain R left - Half Slab Model Back Bone -.2.26.2.4.6.8 Strain R left - mm Figure 23 Stress-TI vs Load of half slab precast with Figure Strain-R left vs Load of half slab precast with c. Observation of Load Concrete Strain Relationship Strain gauge CON embedded at the mid-span in the bottom of concrete X direction shows the strain that occurs in concrete. The shape of the curve backbone strain and load relationship changes two times as the backbone of the curve BI stress and load relationship shown in Fig. 19. The changing of the curve at first, when the first crack occurs at the mid-span of concrete and then the second time when the connection between precast components have cracked. The relationship of load versus strain of concrete can be seen in Fig. 24. Additionally, Rr ight and R left strain gauges that installed on the interface of the joints between precast components at the right and left locations, show the movement of cracks that occur in these locations. Based on the monitoring results show that the strain occurring strain began to occur after the concrete has been cracked. This happens because the strain gauge installed at the concrete surface. So before the concrete cracked, strain gauge has no response. But after the first crack occurs at the connection between precast components, the strain s value has begun to be read. The relationship of load versus strain of R left strain gauges can be seen in Fig.. But the relationship of load versus strain of R right strain gauges could not be obtained, because there was a damage in the strain gauge. d. Observation of Crack Pattern Based on the experimental observation that the crack pattern of monolithic slab Monolithic Model due to loading unloading, the crack pattern from elastic condition until the ultimate condition has diagonal direction. But at the beginning loading, half slab precast Half Slab Model has a crack pattern at mid span and perpendicular to the direction of the joints between the precast components. The next cracking occurs at the connection between the precast components that have begun to be separated. After that, the next crack propagation started in a diagonal direction. So it can be concluded that the half slab of precast initially still behaves as a one-way slab, but after reinforcement at the connection between precast components has been tightened, half slab precast can behave as a two-way slab. The crack propagation of monolithic slab and half slab precast with a triangular connection can be seen in Fig. 27 to Fig.. Strain CON - Half Slab Model 22.3 Strain CON - Half 14.2 Slab Model 213.7 9.38 -. 1,. Strain (me) Figure 24 Strain-CON vs Load of half slab precast with 71

International Journal of Applied Engineering Research ISSN 973-462 Volume 12, Number (17) pp. 744-74 Pola Retak Model-A, Crack Benda propagation Uji- pada of monolithick Beban Retak Awal 16.3 Ton model at 16.3 Pola Retak Model-B, Crack Benda propagation Uji- pada of half Beban slab Retak model Awal.2 Ton at 14.2 ton First Crack Load Position Figure 27 Initial crack of Monolithic and Half Slab Model at crack load Crack Pola propagation Retak Model-A, of monolithic Benda Uji- pada Pembebanan 18.3 Ton model at 18.3 Crack propagation of half slab model at 18.3 ton Load Position Figure 28 Initial crack of Monolithic and Half Slab Model at crack load Crack Pola propagation Retak Model-A, Benda Uji- pada of monolithic Pembebanan 24.4 Ton model at 24.4 Crack Pola propagation Retak Model-C, of half Benda slab Uji- model pada Pembebanan 24.4 Ton at 24.4 ton Load Position Figure 29 Crack propagation of slab model A and B at 24.4 ton load 72

International Journal of Applied Engineering Research ISSN 973-462 Volume 12, Number (17) pp. 744-74 Crack Pola propagation Retak Model-A, Benda Uji- pada of monolithic Pembebanan Akhir model 36.6 at 36.6 Ton Pola Retak Model-C, Crack propagation Benda Uji- pada of half slab Pembebanan model Akhir at.6. ton Ton Load Position Figure 29 Crack propagation of slab model A and B at 24.4 ton load CONCLUSION Base on experimental results, the two-way half slab precast with a has a deflection is higher than the monolithic slab. The differences is reached 12%. The crack load of two-way half slab precast has a crack load smaller than a crack load of the monolithic slab, but not less than 18%. The reduction of crack load shows not many differences compared with the model proposed in the preliminary study. The differences reach 16.%. However, half slab precast with does not require formwork to be installed underneath between precast components as required in the model preliminary study. The strain of monolithic slab at mid-span X direction has a strain s value higher than half slab precast. This happens because in the half slab precast has a connection between a precast component in the X direction. So it can be made reducing the strain in concrete. The propagation of half slab of precast initially still behaves as a one-way slab, but after reinforcement at the connection between precast components has been tightened, half slab precast can behave as a two-way slab. The tension reinforcement of half slab precast in X direction will increase after the initial crack and will increase again after the connection between precast components has begun to be separated. So the backbone of the curve that shows relationship load versus reinforcement stress has three linear shape as shown in Fig. 19. Because of in Y direction there is no connection, then the backbone of the curve has a bi-linear shape as shown in Fig. 17. The value of stress in compression reinforcement will continue to increase if the load is increased. But at the certain load, acceleration of the increasing stress will decrease. This happens due to the shifting position of the neutral axis is getting to the top. REFERENCE [1] Wijanto and Takim (8), State of The Art: Research and Application of Precast / Prestressed Concrete Systems in Indonesia, World Conference on Earthquake Engineering, Beijing China (8). [2] D. Irawan, D. Iranata, P. Suprobo. (12), Experimental Study of Joint Connection Between Precast Component of Half Slab Precast System (Case Study of Jetty Slab Structure at Petrokimia Corporation), Research in Structural Laboratory Civil Engineering Department, Sepuluh Nopember Institute of Technology. [3] D.G. Hieber, J.M. Wacker, M.O. Eberhard, J.F. Stanton, (), State-of-the-Art Report on Precast Concrete Systems for Rapid Construction of Bridges, Final Technical Report Contract T269, Task 3, Bridge Rapid Construction, Department of Civil and Environmental Engineering University of Washington. [4] D.W. Kim, C.S. Shim, (14), Structural Performance of Pre-tensioned Half-depth Precast Panels, Structural Engineering and Mechanic Journal, Vol.34, Issue 6, pp 177-1721. [] D.W. Kim, C.S. Shim, (), Crack Width Control on Concrete Slab using Haf Depth Precast Panels with Loop Joint, Structural Engineering and Mechanic Journal, Vol.3, Issue 1, pp 19-29. [6] Y. Yardim, (13), Performance of Precast Thin Panel as a Permanent Formwork for Precast Composite Slabs. 2nd International Balkans Conference on Challenges of Civil Engineering, BCCCE, 23- May, Epoka University, Tirana, Albania. [7] Siswosukarto (13), Semi Precast Slab as an Alternative Method to Promote Green Construction Residential House Project, Proceeding the 6th Civil 73

International Journal of Applied Engineering Research ISSN 973-462 Volume 12, Number (17) pp. 744-74 Engineering Conference, Asia Region: Embracing the Future through Sustainability ISBN 978-62-86-8-3. [8] R.K. Dowell, and R. Auer, (11), Flexure-Shear Behavior of Precast Concrete Deck Panel with Cast-in- Place Concrete Topping, PCI Journal, Summer (11). [9] P.M.D. Santos, and E.N.B.S. Júlio, (12), A state-ofthe-art review on shear-friction, Journal of Engineering Structures 4, pp 43 448. [] Y.L. Lee, A.T.A. Karim, A.R. Ismail, T.J. Chai, H.B. Koh, S. Nagapan, D. Yeoh, (13), Deflection of Reinforced Concrete Half Slab, International Journal of Construction Technology and Management Vol.1, No.1, pp 6 12. [11] Vakhsouri, B.(16), Time-dependent bond transfer length under pure tension in one way slab, Structural Engineering and Mechanics Journal, Vol 6, No.2, pp 1 312. [12] Tezuka (1994), Prestressed Half Slab Waffle Slab for Long-Span Structure, Shimizu Tech. Res. Bull. No. 13. [13] I. Moldovan, and A. Mathe, (), A Study on Two - Way Post-Tensioned Concrete Waffle Slab, International Conference Interdisciplinarity in Engineering, INTER-ENG 8-9, Tirgu - Mures, Rumania, Published by Elsevier Ltd. [14] D. Fall, J. Shu, R.R.K. Lundgren, K. Zand, (14), Experimental Investigation of Load Redistributions in Steel Fibre Reinforced Concrete, Engineering Structure Journal, 8, pp 61-74. [] J.Y. Kim, M., Jesse, J.M. Longworth, R.G. Wight, and M.F. Green, (8), Flexure of Two-Way Slabs Strengthened with Prestressed or Non-prestressed CFRP Sheets, Journal of Composites for Construction, ASCE July / August [16] D. Gouverneur, R.C.L. Taerwe, (), Strain and Crack Development in Continuous Reinforced Slabs Subjected to Catenary Action, Structural Engineering and Mechanics Journal, Vol 3, No.1, pp 173 188. [17] ACI 437R-3 (3), Strength Evaluation of Existing Concrete Building, Reported by ACI Committee 437. 74