X-RAY OPTICS FOR TWO-DIMENSIONAL DIFFRACTION

Similar documents
Applications of New, High Intensity X-Ray Optics - Normal and thin film diffraction using a parabolic, multilayer mirror

MICROFOCUSING X-RAY EQUIPMENT FOR THE LAB DIFFRACTOMETER

ANALYTICAL MICRO X-RAY FLUORESCENCE SPECTROMETER

RIETVELD REFINEMENT OF POWDER DATA FROM MULTILAYER OPTICS

Lesson 2 Diffractometers

DEVELOPMENT OF A WAVELENGTH DISPERSIVE X-RAY FLUORESCENCE SPECTROMETER USING A MULTI-CAPILLARY X-RAY LENS FOR X-RAY DETECTION

LYNXEYE XE-T. < 380 ev. Innovation with Integrity. Energy. Resolution. High-Resolution Position Sensitive Detector with Superb Energy Resolution XRD

Instructions XRD. 1 Choose your setup , Sami Suihkonen. General issues

TOWARDS FAST RECIPROCAL SPACE MAPPING

LYNXEYE XE. Innovation with Integrity. High-Resolution Energy-Dispersive Detector for 0D, 1D, and 2D Diffraction XRD

Data Collection with. VÅNTEC-2000 Detector

USING A CHARGE-COUPLED DEVICE (CCD) TO GATHER X-RAY FLUORESCENCE (XRF)AND X-RAY DIFFRACTION (XRD) INFORMATION SIMULTANEOUSLY

Dinnebier & Billinge, TA+PXRD course - Part 1, The Equipment

CONFOCAL GRADED d-spacing MULTILAYER BEAM CONDITIONING OPTICS

DOUBLE MULTILAYER MONOCHROMATOR WITH FIXED EXIT GEOMETRY. H.Gatterbauer, P.Wobrauschek, F.Hegediis, P.Biini, C.Streli

SIMULTANEOUS XRD/XRF WITH LOW-POWER X-RAY TUBES

Basic P-XRD instructions for Operating the Instrument

X-RAY BACKSCATTER IMAGING: PHOTOGRAPHY THROUGH BARRIERS

WIDE ANGLE GEOMETRY EDXRF SPECTROMETERS WITH SECONDARY TARGET AND DIRECT EXCITATION MODES

Standard Instructions for the Bruker D8 Advance Diffractometer, EPFL Valais Bragg Brentano and GID (Reflection)

MICRO XRF OF LIGHT ELEMENTS USING A POLYCAPILLARY LENS AND AN ULTRA THIN WINDOW SILICON DRIFT DETECTOR INSIDE A VACUUM CHAMBER

Residual Stress Measurement Part

MINIATURE X-RAY SOURCES AND THE EFFECTS OF SPOT SIZE ON SYSTEM PERFORMANCE

MICROFOCUSING SOURCE AND MULTILAYER OPTICS BASED X- RAY DIFFRACTION SYSTEMS

Cr, Co, Cu, Mo, Ag (others on request) Mean Reflectivity: R > 70%

Spectral distribution from end window X-ray tubes

Supplementary Information

Who is GBC Scientific Equipment?

General Measurement (BB) Part

ON THE DETECTION LIMIT OF TEY (TOTAL ELECTRON YIELD) Maria F. Ebel, Horst Ebel and Robert Svagera

POLYCAPILLARY OPTICS AND X-RAY ANALYTICAL TECHNIQUES

GUNSHOT RESIDUE INVESTIGATIONS USING TXRF

Bruker D8 HRXRD Collecting X-Ray Reflectivity Data using the PathFinder Detector

Atomic and nuclear physics LD. Fine structure of the characteristic x-radiation of an iron anode. Physics

LONG TERM STATISTICS OF X-RAY SPECTROMETERS

Rigaku Innovative Technologies Europe (RITE) Presented by: Dr.Peter Oberta

X-Ray Spectroscopy with a CCD Detector. Application Note

ON THE ENERGY DEPENDENCE OF THE DETECTOR EFFICIENCY OF A Si-PIN DIODE

MOXTEK S NEW ULTRA-LITE X-RAY SOURCES: PERFORMACE CHARACTERIZATIONS

Advancing EDS Analysis in the SEM Quantitative XRF. International Microscopy Congress, September 5 th, Outline

Development of X-ray Tool For Critical- Dimension Metrology

BIFOCAL MINIATURE TOROIDAL SHAPED X-RAY MIRRORS

LECTURE 10. Dr. Teresa D. Golden University of North Texas Department of Chemistry

Miniflex. Rigaku/ Miniflex X-ray Diffractometer System. Rigaku Corporation

research papers First results from a macromolecular crystallography system with a polycapillary collimating optic and a microfocus X-ray generator

BL39XU Magnetic Materials

Real-Time Scanning Goniometric Radiometer for Rapid Characterization of Laser Diodes and VCSELs

PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: )

R-AXIS RAPID. X-ray Single Crystal Structure Analysis System. Product Information

Spectrophotometer. An instrument used to make absorbance, transmittance or emission measurements is known as a spectrophotometer :

First test experiments with FMB- Oxford direct drive DCM at the Sirius beamline of Synchrotron SOLEIL

Copyright -International Centre for Diffraction Data 2010 ISSN

PANalytical X pert Pro High Resolution Specular and Rocking Curve Scans User Manual (Version: )

PSPC/MDG 2000 X-RAY MICRODIFFRACTOMETER. Product Information

(12) Patent Application Publication (10) Pub. No.: US 2007/ A1

Bruker D8 HRXRD. Collecting Reciprocal Space Maps using the LynxEye Position Sensitive Detector

By using patented polycapillary optics this diffractometer obviates the need for monochromators and collimators for linear projection of X-Rays.

RANDY W. ALKIRE, GEROLD ROSENBAUM AND GWYNDAF EVANS

Diamond X-ray Rocking Curve and Topograph Measurements at CHESS

This lecture contains four sections as reading information.

SUPPORTING INFORMATION

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

A Novel Multipass Optical System Oleg Matveev University of Florida, Department of Chemistry, Gainesville, Fl

CHAPTER 7. Components of Optical Instruments

Precise Theta/2-Theta Measurement (PB/PSA) Part

AutoMATE II. Micro-area X-ray stress measurement system. Highly accurate micro area residual stress

Reflection! Reflection and Virtual Image!

Monochromator 611 Manual

The Wave Nature of Light

Low Cost Rolled X-ray Prism Lenses to Increase Photon Flux Density in Diffractometry Experiments

(Refer Slide Time: 00:10)

Institut Max Von Laue - Paul Langevin BP 156X~ Grenoble Cedex~ FRANCE

MICROANALYSIS WITH A POLYCAPILLARY IN A VACUUM CHAMBER

Chapter 36: diffraction

A PORTABLE X-RAY APPARATUS FOR BOTH STRESS MEASUREMENT AND PHASE ANALYSIS UNDER FIELD CONDITIONS.

DESIGN OF SINGLE-BOUNCE MONOCAPILLARY X-RAY OPTICS

Using the Open Eularian Cradle (OEC)

Sources & Beam Line Optics

STUDIES OF INTERACTION OF PARTIALLY COHERENT LASER RADIATION WITH PLASMA

POLYCPILLARY OPTICS: AN ENABLING TECHNOLOGY FOR NEW APPLICATIONS

CHARACTERIZATION OF A PORTABLE X-RAY DEVICE FOR RESIDUAL STRESS MEASUREMENTS

9. Microwaves. 9.1 Introduction. Safety consideration

Solid-state physics. Bragg reflection: determining the lattice constants of monocrystals. LEYBOLD Physics Leaflets P

Collimation Tester Instructions

Application Note (A11)

Fast Laser Raman Microscope RAMAN

Zaidi Embong and Husin Wagiran Physics Department, University Of Technology Malaysia, P.O Box 791, 80990, Johor Baharu

Focusing X-ray beams below 50 nm using bent multilayers. O. Hignette Optics group. European Synchrotron Radiation Facility (FRANCE) Outline

The diffraction of light

Fastest high definition Raman imaging. Fastest Laser Raman Microscope RAMAN

Pseudo-3D pixel detectors for powder diffraction Martijn Fransen

DESIGN AND MEASUREMENT WITH A NEW PORTABLE X-RAY CAMERA FOR FULL-FIELD FLUORESCENCE IMAGING

EUV Plasma Source with IR Power Recycling

ADVANCED OPTICS LAB -ECEN Basic Skills Lab

Observation of X-rays generated by relativistic electrons in waveguide target mounted inside a betatron

A Framed Monochromatic X-Ray Microscope for ICF

Atomic and nuclear physics

Applications of Micro XRF for the Analysis of Traditional Japanese "Ainu" Glass Beads and other Artifacts

Lithography. 3 rd. lecture: introduction. Prof. Yosi Shacham-Diamand. Fall 2004

research papers Scatterless hybrid metal single-crystal slit for smallangle X-ray scattering and high-resolution X-ray diffraction

Transcription:

Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 332 ABSTRACT X-RAY OPTICS FOR TWO-DIMENSIONAL DIFFRACTION Bob B. He and Uwe Preckwinkel Bruker Advanced X-ray Solutions Madison, Wisconsin, USA In two-dimensional X-ray diffraction the requirements of X-ray optics are different from the conventional diffractometer in many aspects. This paper discusses the performance requirements of various X-ray optics devices used for two-dimensional X-ray diffraction as well as commonly used X-ray optics components, such as monochromator, pinhole collimator, cross-coupled multilayer mirrors, UBC (universal beam concept ) device, polycapillary and monocapillary. IINTRODUCTION A two-dimensional X-ray diffraction (XRD 2 ) system has both the capability of acquiring diffraction patterns in 2D space simultaneously, and analyzing the 2D diffraction data accordingly [1-3]. In an XRD 2 system the function of X-ray optics is to condition the primary X- ray beam into the required wavelength, beam focus size, beam profile and divergency. Figure 1 shows a typical X-ray optics assembly for an XRD 2 system (GADDS from Bruker AXS), which includes X-ray tube, monochromator, collimator and beamstop. It also shows the instrument center and the shadow of a fixed chi stage. Using a point X-ray source with pinhole collimation enables small samples or small regions on larger samples to be examined. A beamstop is placed behind the sample in transmission mode diffraction to prevent the direct beam from striking the detector. This configuration enables crystallographic phase, texture, and residual stress to be measured from precise locations on irregularly shaped parts, including curved surfaces. Figure 1. Typical X-ray optics in a standard Bruker GADDS system.

This document was presented at the Denver X-ray Conference (DXC) on Applications of X-ray Analysis. Sponsored by the International Centre for Diffraction Data (ICDD). This document is provided by ICDD in cooperation with the authors and presenters of the DXC for the express purpose of educating the scientific community. All copyrights for the document are retained by ICDD. Usage is restricted for the purposes of education and scientific research. DXC Website www.dxcicdd.com ICDD Website - www.icdd.com

Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 333 The conventional diffraction, either using a point detector or a PSD, is confined within the diffractometer plane, the variation vertical to the diffractometer plan is not considered, the X-ray beam is normally extended in that direction (line focus). In XRD 2, a large portion of the diffraction rings are measured simultaneously. Since the diffraction patterns in all directions are equally important, the ideal X-ray beam profile is a circular spot (point focus). Most conventional diffractometers use the Bragg-Brentano parafocusing geometry, in which the sample surface normal is always a bisector between the incident beam and the diffracted beam. In an XRD 2 system, the diffracted X-rays are measured in a two-dimensional range so that the Bragg- Brentano geometry can not be achieved. In a conventional diffractometer, both the incident beam and diffracted X-rays can be conditioned before reaching the point detector. However, it is only possible to condition the incident beam for an XRD 2 system. Therefore, X-ray optics for XRD 2 systems has different requirements in terms of the beam spectrum purity, divergency and beam cross-section profile. X-RAY BEAM SHAPE FOR XRD 2 In principle, the cross-section shape of the X-ray beam used in an XRD 2 should be an infinitesimal point. In practice, the beam cross-section can be either round or square in limited size. If a line focus beam is used in a two-dimensional diffraction system, the smearing effect will dramatically increase the peak width, especially at the portion of diffraction ring away from the diffractometer plane. Figure 2a. is a diffraction frame of corundum collected with a line-focus incident beam. The diffraction rings are broadened at the portion away from diffractometer plane. As a comparison, Figure 2b shows the diffraction frame collected with a point beam, no smearing effect is observed. Therefore, all the diffraction rings can be used for data analysis. (a) Figure 2. The diffraction frame from corundum powder. (a) smearing effect from line beam. (b) diffraction rings from point beam. (b)

Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 334 BEAM SPREAD OVER FLAT SAMPLE SURFACE (GEOMETRY BROADENING) Conventional diffractometers use the Bragg-Brentano parafocusing geometry [4] as is show in Figure 3. A divergent beam from X-ray tube passes first through divergent slit, then hits the sample surface with an incident angle θ. The incident X-rays spread over the sample surface with various incident angles in the vicinity of θ. The area of irradiated region depends on the incident angle θ and beam divergence. The diffracted rays from the irradiated area leave the sample at an angle 2θ from the corresponding incident rays, pass through the anti-scatter slit, and focus at detector slit. A point X-ray detector can be mounted at the position right after the detector slit or after a crystal monochromator. It can be seen that the beam-spread over the sample varies with the incident angle θ, but the diffracted beam are focused back to the point detector as long as the sample surface normal bisect the incident and diffracted beams. Figure 3. A conventional diffractometer in Bragg-Brentano geometry In an XRD 2 system, the diffracted X-rays are measured simultaneously in a two-dimensional range so that the Bragg-Brentano geometry can not be achieved. The beam-spread over the sample surface can not be focused back to the detector. Figure 4 shows the beam-spread in low incident angle over a flat sample surface observed by a two-dimensional detector. Figure 4a is in reflection mode, the diffracted beam in low 2θ angle is narrower than the diffracted beam in high 2θ angle. Figure 4b shows that the opposite is true in transmission mode. (a) (b) Figure 4. Beam spread on a flat sample surface with a small incident angle. (a) reflection mode. (b) transmission mode.

Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 335 If the sample size is limited to the size comparable to the X-ray beam size, the peak broadening caused by beam spread can be reduced or eliminated. Loading powder sample in capillary is one way to achieve this effect. When collecting phase ID data with flat sample, set the sample ω angle as the half of medium 2θ can also reduce the beam spread effect. AIR SCATTER AND FLUORESCENCE Air scatter in XRD 2 system has a significant contribution to the intensity background. In the conventional diffractometer, one can use anti-scatter slit (Figure 3), diffracted beam monochromator or soller slit to remove most air scatter not travelling in the diffracted beam direction. While all these measures can not be used for XRD2 system, which requires an open space between the sample and 2D detector. As is shown in Figure 5, air scatter is generated from the incident beam and diffracted beam. Obviously, the air scatter from the incident beam is significantly stronger than that from diffracted X-ray rays. The intensity of the air scatter from the incident beam is proportional to the length of the open incident beampath, which is the distance between the sample and the beam collimation exit. As is shown in Figure 1 for a typical optics design for GADDS, in order to reduce air scatter from the incident beam, the tip of the collimator is 6 mm from the sample. The air scatter from the diffracted X-rays is relatively weak, the intensity depends on sample-to-detector distance. It is typically not necessary to take measures to remove air scatter from the diffracted X-rays between the sample and 2D detector. However, if the sample-to-detector distance is large, for instance, 30 cm or above, it is necessary to use Hebeampath or vacuum beampath to reduce air scatter. Figure 5. Air scatters from incident X-ray beam and diffracted X-rays. The radiation fluorescence is another source of intensity background in XRD 2, especially when the X-ray energy of the incident beam is slightly higher than the absorption edge of the sample elements. For example, when Cu-K α radiation is used for iron or ferrous alloys. In a conventional diffractometer, fluorescence can be removed from the collected data by using a diffracted beam monochromator, or energy discrimination device. However, most two-dimensional detectors have a very limited energy resolution and it is impossible to add a diffracted beam monochromator in front of the 2D detector. The best way to avoid fluorescence is to choose a tube target having K α energy lower then the absorption edge of the sample materials. For example, use Cr- K α for ferrous alloys.

Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 336 MONOCHROMATOR AND MULTILAYER MIRRORS In a conventional diffraction system, the monochromator can be used either in the source side or the detector side, or both sides, while it is only possible to have a monochromator in the source side for an XRD 2 system. A crystal monochromator allows only a selected characteristic line to pass through, typically Kα radiation. Multilayer mirrors reflect X-rays in the same way as Bragg diffraction from crystals. Recent developments in X-ray optics include graded multilayer X-ray mirrors, known as Göbel Mirrors [5]. In contrast to conventional monochromator crystal, Göbel Mirrors are manufactured so that the d-spacing between the layers varies in a controlled manner. A crossed-coupled arrangement provides a highly parallel beam which is much more intense than can be obtained with a graphite monochromator. For applications such as microdiffraction where a small spot size is desired, Göbel Mirrors can offer up to an order of magnitude higher intensities than conventional optics. The low divergence of the beam incident on the sample from Göbel Mirrors also decreases the width of crystalline peaks and improves the resolution. 100 Intensity Ratio (mirrors/monochromator) 10 1 Experiment Simulation 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0 Collimator Pinhole Size (mm) Figure 6. Comparison of X-ray intensity between cross-coupled Göbel Mirrors and monochromator for various collimator sizes by experiment and simulation. Experimental results show that the smaller the beam size, the stronger the intensity gains from cross-coupled Göbel Mirrors compared with a monochromator (Figure 6). The intensity breakeven point for Göbel Mirrors versus standard monochromator with pinhole collimation is approximately 0.3 to 0.4 mm. In other words, for applications, such as texture or phase identification from a bulk powdered specimen, which ordinarily employ collimators larger than 0.4 mm, there is no benefit to using Göbel Mirrors. In fact, the low divergence of the resulting beam can cause poor statistical grain sampling in such cases. Therefore, the cross-coupled Göbel Mirrors are especially suitable for microdiffraction and small angle X-ray scattering. The universal beam concept (UBC) device, developed by Bruker AXS, use a single multilayer mirror coupled with line focus X-ray source, which can be easily switched between line focus and point focus by using slit or collimator.

Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 337 PINHOLE COLLIMATOR AND MONOCAPILLARY The pinhole collimator is used to control the beam size and divergence. In an XRD 2 system, the pinhole collimator is normally used together with a monochromator or a set of cross-coupled Göbel mirrors. The beam divergency decreases continuously with decreasing pinhole size for the combination of double pinhole collimator and monochromator [6]. For quantitative analysis, texture, or percent crystallinity measurements, 0.5 mm or 0.8 mm collimators are typically used. In the case of quantitative analysis and texture measurements, using too small a collimator can actually be a detriment, causing poor statistical grain sampling. In such cases, statistics can be improved by oscillating the sample. Capillary X-ray optics is based on the concept of total external reflection. X-rays can be reflected by a smooth surface when the angle of incidence is smaller than the critical angle for total reflection θ c. The critical angle is a function of the wavelength and materials; the shorter the wavelength, the lower the critical angle. When X-rays are reflected by the inner surface of a capillary at a grazing angle smaller than the critical angle of the capillary materials, X-rays are reflected with little energy loss. It can produce significant intensity gain on the sample relative to the pinhole collimators. The following table list the Intensity gain (calculated and experimental) and beam spot size including 90% energy on sample for monocapillaries compared with double pinhole collimators Capillary/Pinhole size: d (mm) Cu-K α -radiation (8.0keV) Mo-K α -radiation (17.4keV) Collimator Gain-cal Gain-exp Spot(90%) Gain-cal Gain-exp Spot-90% Spot-90% 0.10 110 66 0.18 39 40 0.14 0.10 0.30 15 10 0.34 5.6 5.9 0.31 0.31 0.50 7.4 6.0 0.50 2.6 3.0 0.49 0.50 1.00 3.4 4.2 0.89 1.2 1.5 0.97 0.98 REFERENCES [1] Philip R. Rudolf and Brian G. Landes, Two-dimensional X-ray Diffraction and Scattering of Microcrystalline and Polymeric Materials, Spectroscopy, 9(6), pp 22-33, July/August 1994. [2] S. N. Sulyanov, A. N. Popov and D. M. Kheiker, Using a Two-dimensional Detector for X- ray Powder Diffractometry, J. Appl. Cryst. 27, pp 934-942, 1994. [3] B. B. He, U. Preckwinkel and K. L. Smith, Fundamentals of Two-dimensional X-ray Diffraction (XRD2), Advances in X-ray Analysis, Vol. 43, Proceedings of the 48th Annual Denver X-ray Conference, Steamboat Springs, Colorado, USA, 1999. [4] Ron Jenkins and Robert L. Snyder, Introduction to X-ray Powder Diffractometry, John Wiley & Sons, New York, 1996. [5] M. Schuster and H. Göbel, Graded-spacing multilayers for X-ray diffraction applications, 43 rd Denver X-ray Conference. Advances in Z-ray Analysis, 39, 57-71, 1996. [6] B. B. He, Introduction to Two-dimensional X-ray Diffraction, Workshop handout, the 50 th Annual Denver X-ray Conference, Steamboat Springs, Colorado, USA, 2001.