Indumax CLS50/CLS50D. Technical Information

Similar documents
Technical Information Indumax CLS50D/CLS50

Condumax CLS21 and CLS21D

Condumax CLS15 and CLS15D

Condumax W CLS15 and CLS15D

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax CLS21 and CLS21D

Condumax CLS16 and CLS16D

Technical Information Condumax CLS21D/CLS21

Condumax CLS15 and CLS15D

Condumax W CLS15 and CLS15D

Technical Information Condumax CLS15D/CLS15

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Indumax CLS54D. Technical Information

Technical Information Memosens CLS82D

Technical Information Indumax CLS54

Indumax H CLS54. Technical Information

Orbipac CPF81/CPF82 and CPF81D/CPF82D

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

Ceramax CPS341D. Technical Information

Conductivity Sensor for High-Temperature Applications ConduMax W CLS 13

Technical Information Smartec CLD18

Inductive conductivity measurement mypro CLM 431 / CLD 431 inductive

Liquisys M CLM223/253

Smartec S CLD134. Technical Information

Technical Information Orbipore CPS91D and CPS91

Technical Information Smartec CLD18

Memosens CPS96D. Technical Information

Technical Information Liquisys M CLM223/253

Tophit CPS491 and CPS491D

Memosens New technology for contactless, inductive, digital transmission of ph signals

Conductive conductivity measurement mypro CLM 431 / CLD 431 conductive

The transducer component converts the measured signal and displays the actual value.

Technical Information Memosens CPS96D

Technical Information Smartec CLD18

Tophit CPS441 and CPS441D

Conductivity measurement SmarTec S CLD 132

Conductivity measurement Mycom S CLM 153

Technical Information Orbipac CPF81D/CPF82D and CPF81/CPF82

0 2 1 â Ó. itemp HART TMT182. Technical Information

Turbimax CUS71D. Technical Information. Ultrasonic interface sensor Immersion sensor for interface measurement

Flow Measurement SITRANS F M

Digital conductivity transmitter

Tophit CPS491 and CPS491D

Liquisys M COM223/253

Turbidity sensor TurbiMax W CUS 41

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Liquisys M CPM223/253

VITO LT. Global Experience. Locally Applied. A dependable choice.

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below

itemp HART DIN rail TMT112

Temperature transmitter itemp PCP DIN rail TMT 121

prosonic T FMU230, FMU231

Technical Information Memosens CCS50D

Endress Hauser The Power of Know How. Turbidity and Solids Content Sensor TurbiMax P CUS 63 / CUS 63H

Digital inductive conductivity transmitter

Coriolis Massflowmeter

Conductivity Measurement mycom CLM 152

TMU. Coriolis Mass Flow Meter. for liquids and gas

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Temperature Transmitter itemp RTD DIN rail TMT 127

Measuring and Controlling Unit Multronic OC

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Level Measurement Continuous level measurement Radar transmitters

KFS. Flap-type flow meter. Design and range of application

Process display RIA 261

Liquisys M COM223/253

OPTIFLUX 1000 Technical Datasheet

4.00 ULTRASONIC ANALYZER

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Temperature transmitter itemp RTD DIN rail TMT 127

0 2 1 â Ó. itemp HART TMT182. Technical Information

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.

Liquisys M CCM223/253

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

ph/orp Measurement OPM223/253

Measuring and Controlling Unit Multronic

Coriolis Mass Flow Meter Model TM

Technical Information Liquisys M CCM223/253

IsFET sensor for ph Measurement TopHit CPS 491

Inductive conductivity transmitter JUMO CTI-Junior

Electro-Magnetic Flowmeters COPA-XE

Level Measurement Continuous level measurement Radar transmitters

itemp PA TMT184 Technical information

OEM radar transmitter, for aggressive media level measurement

Rosemount 3101, 3102, and 3105

Coriolis Massflowmeter

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization.

Special Documentation Levelflex FMP51, FMP52, FMP55, FMP57

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 H

Transcription:

Technical Information Indumax CLS50/CLS50D Inductive conductivity sensor for standard, hazardous and high-temperature applications, analog or digital with Memosens protocol Application Indumax CLS50/CLS50D conductivity sensors are especially suitable for application in the chemical industry and process engineering. The six-decade measuring range and the high chemical resistance of the materials in contact with medium (PFA or PEEK) permit to use this sensor in a number of various applications, e.g.: Concentration measurement of acids and bases Quality monitoring of chemical products in tanks and pipes Phase separation of product/product mixtures Digital CLS50D sensors are used with the controller Liquiline CM442. Analog CLS50 sensors are used with the transmitters Liquiline CM42, Liquisys CLM223/253 or Mycom CLM153. Your benefits High durability High chemical resistance thanks to PFA coating PEEK version for high temperatures up to 180 C (356 F) Low risk of soiling Dirt-repellent PFA surface Large sensor opening Easy installation Can be installed in T-pieces DN 80 with the outgoing diameter reduced to DN 50 Total cable length up to 55 m (180 ft) Wide measuring range from 2 μs/cm to 2000 ms/cm Integrated, coated Pt 100 temperature sensor, error class A Ex approval EEx ia IIC T6/T4 TI182C/07/EN/03.10 71099527

Function and system design Measuring principle Inductive conductivity measurement A generator (1) generates an alternating magnetic field in the primary coil (2) which induces a current in the medium (3). The strength of the induced current depends on the conductivity and thus the ion concentration of the medium. The current flow in the medium generates another magnetic field in the secondary coil (4). The resulting current induced in the coil is measured by the receiver (5) and processed to determine the conductivity. 1 5 Inductive conductivity measurement 1 Generator 2 Primary coil 3 Current flow in the medium 4 Secondary coil 5 Receiver 2 4 Benefits of inductive conductivity measurement No electrodes, therefore no polarization Accurate measurement in media or solutions with a high soiling degree and a tendency to deposition Complete galvanic separation of measurement and medium 3 a0004894 Important properties Advantages of digital sensors with Memosens protocol Wide measuring range The sensor s measuring range comprises six decades, from 2 μs/cm to 2000 ms/cm. Durability The materials in contact with medium (PEEK, PFA) feature a very high chemical resistance. In addition, the PEEK version is suitable for application at high temperatures of up to 180 C (356 F). Low risk of soiling Thanks to its large opening, the sensor is not susceptible to soiling. The PFA version requires even less cleaning thanks to its dirt-repellent surface. Digital sensors are able to store the following system data in the sensor: Manufacturing data Serial number Order code Date of manufacture Calibration data Calibration date Cell constant Change in cell constant Number of calibrations Serial number of the transmitter used for the last calibration Application data Temperature application range Conductivity application range Date of first commissioning Maximum temperature value Operating hours at high temperatures 2 Endress+Hauser

Measuring system CLS50D A complete measuring system comprises: a CLS50D conductivity sensor with fixed cable a transmitter, e.g. Liquiline CM44x Optional: Weather protection cover for the field installation of the transmitter Assembly for sensor installation in tanks or in pipework, e.g. CLA111 1 2 5 4 Example of a measuring system 1 Liquiline CM44x transmitter 2 Weather protection cover 3 Pipe socket for flange DN50 PN/6 4 Sensor CLS50D, flange version DN50 PN/6, fixed cable with M12 plug 3 a0012990 Endress+Hauser 3

CLS50 A complete measuring system comprises: a CLS50 conductivity sensor with fixed cable a transmitter, e.g. Liquiline CM42 Optional: Weather protection cover for the field installation of the transmitter Assembly for sensor installation in tanks or in pipework, e.g. CLA111 Example of a measuring system 1 Indumax CLS50 2 Liquiline CM42 transmitter 3 Weather protection cover 4 Pipework 5 Pipe socket a0007045 Input Measured variable Conductivity Temperature Cell constant k = 1.98 cm 1 Measuring frequency 2 khz Measuring range Conductivity: Temperature: 2 μs/cm to 2000 ms/cm (uncompensated) 20 to +180 C (-4 to +350 F) Temperature measurement Pt 100 (class A acc. to IEC 60751) 4 Endress+Hauser

Wiring Cable specification The sensor is supplied with a fixed cable. The connection to the transmitter can be extended using the CYK81 (CLS50D) or the CLK5 (CLS50) special measuring cable. BN WH GN YE CYK81 for cable extension for CLS50D max. total cable length: 100 m (330 ft) U + U COM A COM B a0013000 Note! Please note that the residual coupling increases when the cable is extended. WH RD RD BU RD BU GN WH YE BN CLK5 for cable extension for CLS50 max. total cable length: 55 m (180 ft) n.c. Pt 100 a0012998 Performance characteristics Maximum measured error Temperature response time -20 to 100 C (-4 to 212 F): ±(5 μs/cm + 0.5 % of the measured value) > 100 C (212 F): ±(10 μs/cm + 0.5 % of the measured value) PEEK versions: approx. 7 min PFA versions: approx. 11 min Installation conditions Installation position Install the sensor in such a way that the sensor opening is oriented in the flow direction of the medium. The sensor head must be completely immersed in the medium. mm (inch) 1 2 a max. 100 (3.94) Installation position of the sensor 1 Flow direction of medium 2 Minimum water level in the pipe a Sensor distance from the pipe wall a0007035 Endress+Hauser 5

Installation factor In narrow installation conditions, the conductivity measurement is affected by the pipe walls. This effect is compensated by the so-called installation factor. The transmitter corrects the cell constant by multiplication with the installation factor. The value of the installation factor depends on the diameter and the conductivity of the pipe as well as the sensor s distance from the wall. If the distance from the wall is sufficient (a > 15 mm (0.59"), from DN 80), it is not necessary to consider the installation factor (f = 1.00). If the distance from the wall is smaller, the installation factor increases in case of electrically insulating pipes (f > 1) and decreases in case of electrically conductive pipes (f < 1). The installation factor can be measured using calibration solutions or it can be approximately determined from the following diagram. f 1.40 2 1.20 1.00 0.80 1 0 5 10 15 20 25 a [mm] 0.20 0.39 0.59 0.79 0.98 Relationship between installation factor f and distance from wall a 1 Electrically conductive pipe wall 2 Insulating pipe wall a [inch] a0005441 Air set CLS50 To compensate residual coupling in the cable and between the two sensor coils, you must perform a zero calibration in air ("air set") before installing the sensor. For further information, refer to the Operating Instructions of your transmitter. CLS50D The digital sensor is already adjusted at the factory, an on-side compensation is not necessary. 6 Endress+Hauser

Installation of sensors with flange The sensor is suitable for installation in T-pieces DN 80 with the outgoing diameter reduced to DN 50. Warning! Danger of injuries by leaking medium Tighten the nut with a torque of at least 20 Nm. To avoid leakages, regularly check the tightness of the nut. Flange, not in contact with medium Fixed flange, not in contact with medium (order option "process connection": 5, 6, 7) 1 2 3 Flange (stainless steel) Nut Sealing disk (Gylon ) 4 5 O-ring Sensor a0007061 Flange, in contact with medium Fixed flange, in contact with medium (order option "process connection": 3, 4) 1 2 Flange (stainless steel) Nut 3 4 O-ring Sensor a0007062 Endress+Hauser 7

Lap-joint flange, not in contact with medium Lap-joint flange, not in contact with medium (order option "process connection": A, B, C) 1 2 3 Lap-joint flange (PP-GF) Nut (stainless steel) Flange (PVDF) 4 5 O-ring Sensor a0007063 Installation of sensor assembly Installation of sensor with assembly 1 CLA111 with suspension bracket 2 CLA111 with flange connection 3 4 CLA140 with flange connection CYA611 a0007064 Environment Ambient temperature range Storage temperature Ingress protection 10 to +70 C (+10 to +160 F) 20 to +80 C (-4 to +180 F) IP 67 / NEMA 6 (installed with original sealing) 8 Endress+Hauser

Process Process temperature Process pressure CLS50D 20 to 125 C (-4 to 260 F), acc. to the sensor version, see pressure-temperature diagram CLS50 20 to 180 C (-4 to 360 F), acc. to the sensor version, see pressure-temperature diagram max. 20 bar (290 psi), acc. to the sensor version, see pressure-temperature diagram Pressure-temperature diagram p [psi] p [bar] 290 20 1 232 16 2 145 10 20 +125 180 4 257 356 T [ C] T [ F] p [psi] p [bar] 232 20 16 3 4 145 10 5 6 7 20 +20 125 180 4 +68 257 356 T [ C] T [ F] Pressure-temperature diagram (sensor versions, see Ordering information) 1 PEEK sensor, CLS50 up to 180 C (356 F), CLS50D up to 125 C (257 F), without flange 2 PFA sensor upt to 125 C (257 F), without flange 3 PEEK/PFA sensor up to 125 C (257 F), with DN 50/ANSI 2" flange, 1.4404 (AISI 316 L) 4 PEEK sensor, CLS50 up to 180 C (356 F), CLS50D up to 125 C (257 F), with DN 50/ANSI 2" flange, 1.4404 (AISI 316 L) 5 PEEK/PFA sensor up to 125 C (257 F), with JIS flange, 1.4404 (AISI 316 L) 6 PEEK sensor, CLS50 up to 180 C (356 F), CLS50D up to 125 C (257 F), with JIS flange, 1.4404 (AISI 316 L) 7 PEEK/PFA sensor, with PVDF flange a0007066 Endress+Hauser 9

Mechanical construction Sensor dimensions Dimensions of sensor version with G ¾ thread * Dimensions of PEEK version a0007069 Dimensions of sensor version with NPT 1" thread a0007070 Flange dimensions 1 2 d 2 b d 2 b a Øk D a Øk D Flange dimensions 1 Lap-joint flange (PP-GF) 2 Fixed flange (stainless steel) a0007071 10 Endress+Hauser

Lap-joint flange PP-GF DN 50 PN 10 ANSI 2" 150 lbs JIS 10K 50A D 165 165 152 Ø k 125 121 120 d 2 4 x 18 8 x 19 4 x 19 b 18 18 18 a 78 78 78 Screws M16 M16 M16 Fixed flange SS 316 L DN 50 PN 16 ANSI 2" 300 lbs JIS 10K 50A D 165 165.1 155 Ø k 125 127 120 d 2 4 x 18 8 x 19 4 x 19 b 18 22.2 16 a 27 27 27 Screws M16 M16 M16 Weight Material Chemical durability approx. 1350 g (2.98 lbs) Sensor: PEEK, PFA (depending on ordered version) Sensor seal: Viton, Chemraz (depending on ordered version) Process connections: G ¾: CLS50: stainless steel 1.4571 (AISI 316 Ti) CLS50D: PEEK NPT 1": PEEK Fixed flange: stainless steel 1.4404 (AISI 316 L) Sealing disk: PTFE Lap-joint flange: PP-GF Flange combined with lap-joint flange: PVDF Medium Concentration PEEK PFA Chemraz Viton Sodium hydroxide solution NaOH 0 to 50 % 20 to 100 C (68 to 212 F) 20 to 80 C (68to 176 F) 0 to 150 C (32 to 302 F) not suitable Nitric acid HNO 3 0 to 5 % 20 to 60 C (68 to 140 F) 20 to 60 C (68 to 140 F) 0 to 40 % 20 C (68 F) 20 to 60 C (68 to 140 F) 0 to 150 C (32 to 302 F) 0 to 150 C (32 to 302 F) 0 to 120 C (32 to 248 F) 0 to 120 C (32 to 248 F) Phosphoric acid 0 to 50 % 20 to 60 C H 3 PO 4 (68 to 140 F) 20 to 60 C (68 to 140 F) 0 to 150 C (32 to 302 F) 0 to 120 C (32 to 248 F) Sulphuric acid H 2 SO 4 Hydrochloric acid HCl 0 to 2.5 % 20 to 80 C (68 to 176 F) 20 to 100 C (68 to 212 F) 0 to 30 % 20 (68 F) 20 to 100 C (68 to 212 F) 0 to 5 % 20 to 100 C (68 to 212 F) 0 to 10 % 20 to 100 C (68 to 212 F) 20 to 50 C (68 to 122 F) 0 to 150 C (32 to 302 F) 0 to 150 C (32 to 302 F) 0 to 150 C (32 to 302 F) 20 C (68 F) 0 to 150 C (32 to 302 F) 0 to 120 C (32 to 248 F) 0 to 120 C (32 to 248 F) 0 to 120 C (32 to 248 F) 0 to 120 C (32 to 248 F) No responsibility is taken for the correctness of this information. Endress+Hauser 11

Ordering information Product structure CLS50D Approval AA Non-hazardous area BA ATEX II 1G EEx ia IIC T4/T6 BV ATEX II 3G Ex nl IIC T4/T6 + NEPSI Ex nl IIC T4/T6 C2 FM IS NI Cl. I, II, III, Div. 1&2, Group A-G FB CSA IS NI Cl. I, II, III, Div. 1&2, Group A-G NA NEPSI Ex ia IIC T4/T6 Process connection A Lap joint flange DN 50 PN 10, PP-GF B Lap joint flange ANSI 2" 150 lbs, PP-GF C Lap joint flange JIS 10 K 50 A, PP-GF 1 Thread G ¾, stainless steel 1.4571 (AISI 316 Ti) 2 Thread NPT 1", PEEK 3 Flange DN 50 PN 16, stainless steel 1.4404 (AISI 316 L) 4 Flange ANSI 2" 300 lbs, stainless steel 1.4404 (AISI 316 L) 5 Flange DN 50 PN 16, stainless steel 1.4404 (AISI 316 L), PTFE sealing disk 6 Flange ANSI 2" 300 lbs, stainless steel 1.4404 (AISI 316 L), PTFE sealing disk 7 Flange JIS 10 K 50 A, stainless steel 1.4404 (AISI 316 L), PTFE sealing disk Sensor material / seal A PFA ; Chemraz B PEEK ; Viton C PEEK ; Chemraz Cable length 1 3 m (9.84 ft) 2 7 m (23 ft) 3 15 m (49 ft) 7... m fixed cable, max. 50 m 8... ft fixed cable, max. 164 ft Cable connection 1 Fixed cable, terminated cable cores 2 Fixed cable, M12 plug CLS50D- F1 HC order code Calibration (single choice only) Cell constant Dienstleistung (multiple choice possible) LABS free (LABS = paint-wetting impairment substances) TAG (multiple choice possible) 1 TAG, see additional specification 2 Feldbus TAG Note! To complete your order code, simply add the options to the end of order code. If you have any questions, please contact your local sales office. 12 Endress+Hauser

CLS50 Approval A Non-hazardous area G ATEX II 1G EEx ia IIC T4/T6 H NEPSI Ex ia IIC T4/T6 L Non-hazardous area, PWIS free O FM IS NI Cl. I, II, III, Div. 1&2, Group A-G S CSA IS NI Cl. I, II, III, Div. 1&2, Group A-G T TIIS V ATEX II 3G Ex nl IIC T4/T6 + NEPSI Ex nl IIC T4/T6 Process connection A Lap joint flange DN 50 PN 10, PP-GF B Lap joint flange ANSI 2" 150 lbs, PP-GF C Lap joint flange JIS 10 K 50 A, PP-GF 1 Thread G ¾, stainless steel 1.4571 (AISI 316 Ti) 2 Thread NPT 1", PEEK 3 Flange DN 50 PN 16, stainless steel 1.4404 (AISI 316 L) 4 Flange ANSI 2" 300 lbs, stainless steel 1.4404 (AISI 316 L) 5 Flange DN 50 PN 16, stainless steel 1.4404 (AISI 316 L), PTFE sealing disk 6 Flange ANSI 2" 300 lbs, stainless steel 1.4404 (AISI 316 L), PTFE sealing disk 7 Flange JIS 10 K 50 A, stainless steel 1.4404 (AISI 316 L), PTFE sealing disk Sensor material ; seal A PFA ; Chemraz B PEEK ; Viton C PEEK ; Chemraz Cable length and temperature range 1 5 m (16 ft) fixed cable, max. 125 C (257 F) 2 10 m (32 ft) fixed cable, max. 125 C (257 F) 3 20 m (65 ft) fixed cable, max. 125 C (257 F) 4 fixed cable of specific length, max. 55 m (180 ft), max. 125 C (257 F) 5 5 m (16 ft) fixed cable, max. 180 C (356 F) (PEEK only, version for non-hazardous areas only) 6 10 m (32 ft) fixed cable, max. 180 C (356 F) (PEEK only, version for non-hazardous areas only) CLS50- complete order code Certificates and approvals Ex approvals CLS50 ATEX II 1G Ex ia IIC T3/T4/T6 ATEX II 3G Ex nl IIC T4/T6 + NEPSI Ex nl IIC T4/T6 FM/CSA IS NI Cl. I, II, III, Div. 1 & 2; Group A - G in connection with a Liquiline CM42 or Mycom CLM153 transmitter NEPSI Ex ia IIC T4/T6 Endress+Hauser 13

Accessories Measuring cables For CLS50D CYK81 measuring cable Non-terminated measuring cable for extension of sensor cables of e.g. Memosens sensors, CUS31/CUS41 2 wires, twisted pair with shield and PVC-sheath (2x2x 0.5 mm 2 + shield) Sold by the meter, order no.: 51502543 Junction box RM For cable extension (e.g. for Memosens sensors) 5 terminals Cable entries: 2 x Pg 13.5 Material: PC Ingress protection: IP 65 Order no.: 51500832 For CLS50 Extension cable CLK5 For inductive conductivity sensors, for extension via the VBM junction box, sold by the meter Order no.: 50085473 Junction box VBM For cable extension 10 terminals Cable entries: 2 x Pg 13.5 or 2 x NPT ½" Material: aluminum Ingress protection: IP 65 (i NEMA 4X) Order numbers: cable entries Pg 13.5: 50003987 cable entries NPT ½": 51500177 Transmitters For CLS50D Liquiline CM44x Multiple-channel transmitter for the connection of digital sensors with Memosens technology Power supply: 85 to 265 V AC, 18 to 36 V DC or 20 to 28 V AC (not CM448) Universally upgradeable SD card slot Alarm relay IP 66 Ordering acc. to product structure (Technical Information TI444C/07/en) For CLS50 Liquiline CM42 (for analog conductivity sensors and digital conductivity sensors with Memosens technology) Modular two-wire transmitter for Ex and non-ex areas Hart, PROFIBUS or FOUNDATION Fieldbus available Ordering acc. to product structure, see Technical Information (TI381C/07/en) Liquisys CLM223/253 (for analog conductivity sensors) Transmitter for conductivity, field or panel-mounted housing, Hart or PROFIBUS available Ordering acc. to product structure, see Technical Information (TI193C/07/en) Mycom CLM153 (for analog conductivity sensors) Transmitter for conductivity, one or two channel version, Ex or Non-Ex, Hart or PROFIBUS available Ordering acc. to product structure, see Technical Information (TI234C/07/en) 14 Endress+Hauser

Assemblies Calibration solutions Dipfit CLA111 Immersion assembly for open and closed tanks with flange DN 100; Ordering acc. to product structure, see Technical Information TI135C/07/en Dipfit CLA140 For the inductive sensor CLS50/CLS50D Immersion assembly with flange connection for highly demanding processes; Ordering acc. to product structure, see Technical Information TI196C/07/en Immersion assembly Dipfit CYA611 For sensor immersion in basins, open channels and tanks, PVC Ordering acc. to product structure, see Technical Information TI166C/07/en Precision solutions, traceable to SRM (standard reference material) by NIST, for qualified calibration of conductivity measurement systems according to ISO 9000, with temperature table CLY11-B 149.6 μs/cm (reference temperature 25 C / 77 F), 500 ml / 16.9 fl.oz Order no. 50081903 CLY11-C 1.406 ms/cm (reference temperature 25 C / 77 F), 500 ml / 16.9 fl.oz Order no. 50081904 CLY11-D 12.64 ms/cm (reference temperature 25 C/ 77 F), 500 ml / 16.9 fl.oz Order no. 50081905 CLY11-E 107.0 ms/cm (reference temperature 25 C / 77 F), 500 ml / 16.9 fl.oz Order no. 50081906 Endress+Hauser 15

Instruments International Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel.+41 61 715 81 00 Fax+41 61 715 25 00 www.endress.com info@ii.endress.com TI182C/07/EN/03.10 71099527 FM+SGML 6.0