Inductive sensor slot-type SI2-K08-AP7

Similar documents
Inductive sensor BI2-Q4,7-AN6X

Isolators A3/1. Vibration Transducer Supply Unit Series

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1.

Binary Output Series 9175

Isolating Repeater Input Series 9163

KFS. Flap-type flow meter. Design and range of application

Design and applications

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Binary Output without Power Supply Series 9176

... for hydraulic and general applications in hazardous areas

Assembly. Front view. HiC2441. SL2 1b. Termination Board

SALES SERVICE +358 (0)

Temperature Input Module for Zone 1 Series 9482/32

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Inductive angle sensor. 4-wire, analog output. Ri360P1-QR14-ELiU5X2-0,3-RS5. Rectangular, plastic Many mounting possibilities

Analog Universal Module HART for Zone 2 Series 9468/33

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Inductive linear position sensor LI400P0-Q25LM0-LIU5X3-H1151

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Technical Data. General specifications. Rated operating distance s n 3 mm

Digital Input Output Module for Zone 2 Series 9470/33

Magnetically Actuated Linear Position Sensor WIM100-Q25L-LIU5X2-H1141

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Digital Input Output Module for Zone 2 Series 9470/33

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Inductive Linear Position Sensor LI800P0-Q25LM0-LIU5X3-H1151

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Isolators A3/1.

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Digital Input Output Module for Zone 1 Series 9470/32

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

Inductive Angle Sensor With Analog Output RI360P1-QR14-ELIU5X2

Inductive Linear Position Sensor IO-Link LI100P0-Q25LM0-ELIUPN8X3-H1151

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Temperature transmitter itemp RTD DIN rail TMT 127

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

4-20 ma Vibration Transmitter, Top connector

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Safety Instructions Nivotester FTC625, FTC325

Resistance thermometer Model TR30, compact design

Rail mounted Temperature Transmitter TH102/TH102-Ex

Assembly. Front view. Switch Power Rail

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Operating Instructions

MINI MCR-SL-UI-I-LP-NC

Relative and absolute pressure transmitter type 528

Positioner with HART Communication Type 3780

Resistance thermometer Model TR30, compact design

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Connection. Input EEx ia IIC. Input I. Input II R 1 R 1 A B A 2+ B LB SC. yellow. red. Composition

A6500-UM Universal Measurement Card

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

INSTRUCTION MANUAL (ATEX / IECEx)

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

Fieldbus Isolating Repeater Series 9185/11

SINEAX TI 807 Passive DC signal isolator

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10

0 2 1 â Ó. itemp HART TMT182. Technical Information

Operating Instructions

Technical Information Barrier RB223

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Temperature Transmitter itemp RTD DIN rail TMT 127

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Assembly. Front view. Switch Power Rail

Single-Channel Safety Barriers Series 9001

Assembly. Front view. Power Rail

Remote I/O. 74 Remote I/O. Remote I/O System

Any installation position possible. 1K5, but C. < 2 % of the control range. < 0,2 % / 0,1 bar, type 824.P < 0,1 % / 0,1 bar. Approx.

CE620. Piezoelectric accelerometer with integrated electronics. IECEx

Intrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

Digital I/O Coupler (4-wire) Series 9413/21

Temperature transmitter itemp PCP DIN rail TMT 121

Remote Switching Unit nivotester FTL 320

Signal conditioner - MACX MCR-UI-UI-NC

Rudder or propeller angular position transmitter KINAX WT720

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

Inductive Linear Position Sensor LI200P0-Q25LM0-HESG25X3-H1181

Transcription:

SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type code SI2-K08-AP7 Ident no. 1719501 Slot width 2 mm Repeatability ð 2 % of full scale Temperature drift 10 % Hysteresis 3 15 % Ambient temperature -25 +70 C Operating voltage Residual ripple DC rated operational current No-load current I 0 Residual current Rated insulation voltage Short-circuit protection Voltage drop at I e Wire breakage / Reverse polarity protection Output function Switching frequency 10 30VDC ð 10 % U ss ð 100 ma ð 10 ma ð 0.1 ma ð 0.075 kv no ð 1.5 V yes/ yes (voltage supply) 3-wire, NO contact, PNP 1 khz Functional principle Inductive sensors detect metal objects contactless and wear-free. For this purpose they use a high-frequency electromagnetic AC field that interacts with the target. The sensors hosting a ferrite core coil generate the AC field through an LC resonant circuit. Design slot sensor, K08 Dimensions 11 x 15 x 8 mm Housing material plastic, PP Material active area Plastic, PP Connection cable Cable quality 0.8 mm, Lif91Y, TPE-O, 0.5m Cable cross section 1 x 0.1 mm 2 Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP67 MTTF 2283 years acc. to SN 29500 (Ed.99) 40 C

SI2-K08-AP7 Distance D Distance T Distance S Distance G Distance A Distance C 5 mm 1 mm

ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) Cable connection Wiring diagram Type code Ident no. 1007700 Slot width 2 mm Repeatability ð 2 % of full scale Temperature drift 10 % Hysteresis 1 10 % Ambient temperature -25 +70 C Output function Switching frequency Voltage Non-actuated current consumption Actuated current consumption 2-wire, NAMUR 2.5 khz Nom. 8.2 VDC ï 2.1 ma ð 1.2 ma Approval acc. to KEMA 02 ATEX 1090X Internal capacitance (C i) / inductance (L i) 250 nf / 350 µh Device designation É II 1 G Ex ia IIC T6 Ga/II 1 D Ex ia IIIC T95 C Da (max. U i = 20 V, I i = 60 ma, P i = 130 mw) Functional principle Inductive sensors detect metal objects contactless and wear-free. For this purpose they use a high-frequency electromagnetic AC field that interacts with the target. The sensors hosting a ferrite core coil generate the AC field through an LC resonant circuit. Design Dimensions Housing material Material active area Connection slot sensor, K08 11 x 15 x 8 mm plastic, PP Plastic, PP cable two Cable quality 1 mm, LifY, PVC, 0.5m Cable cross section 2 x 0.08 mm 2 Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP67 MTTF 6198 years acc. to SN 29500 (Ed.99) 40 C

Distance D Distance T Distance S Distance G Distance A Distance C 5 mm 1 mm

Accessories Type code Ident no. Description Dimension drawing IM1-22EX-R 7541231 Isolating switching amplifier, dual-channel; 2 relay outputs NO; input NAMUR signal; selectable ON/OFF mode for wirebreak and short-circuit monitoring; adjustable signal flow (NO/ NC mode); removable terminal blocks; 18 mm width; universal voltage supply unit

Operating manual Intended use This device fulfills the directive 94/9/EC and is suited for use in explosion hazardous areas according to EN60079-0:2012, -11:2012, -26:2007. Further it is suited for use in safety-related systems, including SIL2 as per IEC 61508. In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives. For use in explosion hazardous areas conform to classification II 1 G and II 1 D (Group II, Category 1 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for dust atmospheres). Marking (see device or technical data sheet) É II 1 G und Ex ia IIC T6 Ga acc. to EN60079-0 and -26 and É II 1 D Ex ia IIIC T95 C Da acc. to EN60079-0 Local admissible ambient temperature ATEX category II 2 G electrical equipment -40 +70 C, category II 1 D -25 +70 C. The corresponding temperature classes are provided in the ATEX type-examination certificate. Installation / Commissioning These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas. Please verify that the classification and the marking on the device comply with the actual application conditions. This device is only suited for connection to approved Exi circuits compliant to EN60079-0 and -11. Please observe the maximum admissible electrical values. After connection to other circuits the sensor may no longer be used in Exi installations. When interconnected to (associated) electrical equipment, it is required to perform the "Proof of intrinsic safety" (EN60079-14). When employed in safety systems to IEC 51408 it is required to assess the failure probability (PFD) of the complete circuitry. Installation and mounting instructions Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device. If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields. The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet. service / maintenance Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed.