Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

Similar documents
Stabilized Differential Relay SPAD 346. Product Guide

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

SPAD 346 C Stabilized differential relay

REK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual

SPAE 010, 011 High Impedance Protection Relay

SFIBER Fibre-optic Option Card for Lon Star Coupler RER 111. Technical Reference Manual

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

SPAD 346 C. Stabilized Differential Relay. User s manual and Technical description SPAD 346 C V ~ V. f n SPCD 3D53 SPCJ 4D28

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

REF 610 Feeder Protection Relay. Technical Reference Manual

SPAJ 144 C. Combined overcurrent and earth-fault relay SPAJ 144 C. User s manual and Technical description A CBFP V ~ V.

Protection and control. Sepam range Sepam 100 LA Self-powering protection. Merlin Gerin Square D Telemecanique

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

Type CP-S, CP-C & CP-A Switch mode

SPAS 120 C Directional earth-fault relay

)HDWXUHV Voltage restraint overcurrent stage with five different inverse or definite time characteristics

Harmonic restraint earth fault or single-phase overcurrent protection

SPAS 348 C. Feeder Protection Relay. User s manual and Technical description SPAS 348 C V ~ V. t 2 > [ s ] f n = 50Hz 60Hz

XUA1 - AC Voltage and phase balance relay

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

SPAA 341 C. Feeder Protection Relay. User s manual and Technical description SPAA 341 C. U aux V ~ V. f n. t 2 > [ s ] 0 I 0 >> Trip

SPAJ 111 C. Sensitive earth-fault relay SPAJ 111 C. User s manual and Technical description. U aux V ~ V. f n. n ( I o>> SPCJ 1C7

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

SPAJ 135 C. Combined overcurrent and earth-fault relay SPAJ 135 C. User s manual and Technical description. U aux V ~ V.

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

SPAA 120 C and SPAA 121 C Feeder protection relay

XI1-I Time overcurrent relay. (Januar 2007) Manual XI1-I (Revision New)

CAN-IO Custom IO remote module

Programmable AC Voltage Transducer MT416

Programmable AC Current Transducer MT418

SPAC 335 C and SPAC 336 C Feeder terminals

Phase and neutral overcurrent protection

Analog signal converters CC-E I/I

Multimeter 500CVD21 RTU500 series

Končar TMS - Bushing monitoring

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

MHCO MHCO-RI. General Characteristics The transducer MHCO provide a measurement of current or voltage fully isolated and safe.

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

SPAJ 110 C. Earth-fault relay SPAJ 110 C. User s manual and Technical description. U aux V ~ V f n. n ( I o>> SPCJ 1C8

satech SynchroStar GPS 200 Series

presentation contents application advantages

ISOMETER IRDH575. Approvals

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

XF2 Frequency Relay. Manual XF2 (Revision A)

Thermistor motor protection relays

Time over/underfrequency relay with protection assemblies

Complex Solution for the Distribution Substation REF 542plus. Application and Setting Guide

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Energy Management Three-phase energy meter with output modules Type EM4-DIN

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

Coupling Relays and Converters

SPAF 340 C Frequency Relay

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

Three-phase monitoring relays CM-PFE and CM-PFE.2

Plug-in microprocessor controlled multifuncional relay with automatic shorting of c.t.

Instantaneous Overcurrent Relay

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

VOLTAGE DETECTING SYSTEMS

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

FMR. Ultra Line FEEDER MANAGER RELAY

Time-overcurrent relays and protection assemblies

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

Time relay RXKA 1. (xx jpg) RXKA 1

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

XP2-R Power and Reverse Power Relay

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Overcurrent Protection / 7SJ45

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Protection Relays. U-MLEs-PLs-Ts. Ultra-Ts. DC SUBSTATION PROTECTIVE RELAY (single voltage Line Test) 32, 45, 49, 64, 76, 79, 80

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PVE

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

IB IL AI 2/SF. Function. INTERBUS Inline Terminal With Two Analog Input Channels. Data Sheet 5564A

Installation / Monitoring Technique

Three-phase monitoring relays

VersaPoint I/O Module

Thermistor motor protection relays

Electronic timer CT-MFS.21

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

Fixed Series Compensation

Transformer differential protection

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

MT 560/UMT TRANSDUCER & ANALYZER

Temperature Controller model MFC-301/T-Dry. Version for Dry Transformers and Motors. Technical Manual. Licht

IRI1-ER - Stabilized Earth Fault Current Relay

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

Liquid level monitoring relay CM-ENS.2x

S200 I/O System Units

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Transcription:

Issued: April 1999 Status: Updated Version: B/08.11.200 Data subject to change without notice Features Versatile, multifunction line fault indicator for distribution networks Overcurrent, earth-fault and phase unbalance indication in one Definite time operation characteristic and wide setting ranges Two current sensors available: type KOHU 24A1 and type KOKU 072G3 Set values, measured values, fault records, event records and diagnostic data can be read locally and remotely via the serial port Serial communication between fault indicator and substation control level system Alternative analog or digital outputs, where no fibre-optic SPA bus is available Improved system reliability supported by a built-in sophisticated self-supervision system High immunity to conducted electromagnetic interference Snap-on mounting on standard DIN rail or surface mounting on cabinet wall Member of the SPACOM product family and ABB s Substation Automation system Application The fault indicator type is used in association with disconnector terminal units (DTUs) for detection of short circuits, earth faults and phase discontinuity in distribution networks. The fault indicator functions a data acquisition unit which allows measured information and alarms from a DTU to be read by a remote control system. The information can be used e.g. for locating faults in the distribution network. If no serial bus (SPA bus) is available, information can be obtained via the relay outputs and the analog outputs of the fault indicator. 1

Design The fault indicator is energized from current sensors type KOHU 24A1 or KOKU 072G3. The current sensors isolate the power network from the electronics and match the phase currents to suit the measuring circuits of the fault indicator. The fault indicator comprises three functional units, i.e. an overcurrent unit, an earth-fault unit and a phase unbalance unit. Further, the indicator includes a serial communication unit which communicates with hierarchically superior systems via the serial bus. The overcurrent unit monitoring the three phase currents starts if one or more of the supervised phase currents exceed the set start value I>. If the fault persists, an alarm will be given after a set time t>. The earth-fault unit monitoring the residual current starts if the residual current exceeds the set start value I 0 >. If the fault persists, an alarm will be given after a set time t 0 >. The phase unbalance unit monitoring the phase currents starts if the phase unbalance exceeds the set start value I>. If the fault persists, an alarm will be given after a set time t >. The fault indicator is provided with three analog outputs, one for the load current, one for the earth-fault current and one for the phase unbalance. Further, the indicator has three contact alarm outputs. Data communication The indicator is provided with a serial interface connecting the equipment to the SPA bus. Self-supervision The indicator incorporates a sophisticated self-supervision system with auto-diagnosis, which increases the availability of the device and the reliability of the system. The selfsupervision system continuously monitors the hardware and the software of the indicator. When a permanent internal relay fault is detected, the IRF indicator on the relay front panel is lit. At the same time a fault message is transmitted to the higher-level system over the serial bus. Further, in most fault situations, a fault code is shown on the display of the device. The fault code indicates the type of the fault that has been detected. Auxiliary supply voltage The fault indicator is powered from an external 24 V dc source (20 30 V dc). The power consumption is 1.5 3 W, depending on the state of the indicators and output relays. 2

Technical data 7DEOH(QHUJL]LQJLQSXWV Type Primary current KOHU 24A/ KOKU 073G2 secondary current Measuring range of phase current input 0 700 A 0 0.175 A Thermal withstand continuously 400 A 0.1 A for 1 s, with connection 20 ka (I th ) 2.3 A box SPEC 3 Dynamic current withstand, including connection box SPEC 3 Half-wave value 50 ka (I dyn ) 5.7 A Earth-fault protection measuring range 0 70 A - Input impedance <100 Ω Rated frequency f n, according to order 50 Hz or 60 Hz 7DEOH2YHUFXUUHQWXQLW Start current I> 30 300 A Start time, typically Operate time t> 0.06 300 s Reset time, typically Drop-off/pick-up ratio, typically 0.95 Operate time accuracy ±2% of set value or ±25 ms Operation accuracy ±3% of set value 7DEOH(DUWKIDXOWFXUUHQWXQLW Start current I 0 > 2 20 A Start time, typically Operate time t> 0.1 300 s Reset time, typically Drop-off/pick-up ratio, typically 0.95 Operate time accuracy ±2% of set value or ±25 ms Operation accuracy ±5% of set value or ±1% of I load 7DEOH3KDVHXQEDODQFHXQLW Start current I> 10 60% of I n Start time, typically 90 ms Operate time t> 0.1 300 s Reset time, typically 90 ms Drop-off/pick-up ratio, typically 0.90 Operate time accuracy ±2% of set value or ±75 ms Operation accuracy ±5% of displayed value 7DEOH2XWSXWFRQWDFWUDWLQJV According to IEC 255-0-20 Rated voltage Breaking capacity (L/R < 7 ms) Making capacity Minimum load 250 V ac 2 A, 20 V dc or 250 V ac 5 A, 0.5 s 10 ma at 5 V dc Contact material AgCdO 2 3

Technical data (cont d) 7DEOH$QDORJRXWSXWV Voltage range 0 5 V dc Load impedance, min. 10 kω Response delay <500 ms Accuracy I load when current >5 A 5% or 30 mv I 0 5% or ±30 mv I when I phase (I L1, I L2 or I L3 ) 10 A ±200 mv 7DEOH([WHUQDOFRQWUROLQSXW Control voltage Control current at activated input, typically 7DEOH'DWDWUDQVPLVVLRQ Transmission mode Transmission protocol Data transfer rate, selectable 7DEOH3RZHUVXSSO\ Supply voltage Power consumption, depending on relays and indicators 18 30 V dc 10 ma Serial bus SPA bus 4800 Bd or 9600 Bd 20 30 V dc 1.5 3 W 7DEOH7HVWVDQGVWDQGDUGV Test voltages (for the output relays) Interference tests (the test arrangement includes the connection box SPEC 3 and a 2 m connection cable) Insulation test (IEC 255-5) Impulse test (IEC 255-5) Insulation resistance (IEC 255-5) High frequency disturbance test (IEC 255-6), common mode High frequency disturbance test (IEC 255-6), differential mode Electrostatic discharge test (IEC 255-22-2, class III), air discharge Electrostatic discharge test (IEC 255-22-2, class III), contact discharge 2 kv, 50 Hz, 1 min 5 kv, 1.2/50 µs, 0.5 J >100 MΩ, 500 V dc 2.5 kv, 1 MHz 1.0 kv, 1 MHz Fast transient test (IEC 255-22-4, 2 kv class III) Environmental conditions Specified ambient service -10 +55 C temperature range Transport and storage -40 +70 C temperature range Climatic environmental tests Damp heat test (IEC 68-2-30) RH=93%, +55 C, 6 cycles Dry heat test (IEC 68-2-2) +55 C/16 h Dry cold test (IEC 68-2-1) -10 C/16 h Degree of protection by enclosure IP 20 of the device case (IEC 529) Weight about 1.3 kg 8 kv 6 kv 4

Block diagram KOHU 24A1 L1 L2 L3 M Motor operating device Control unit SPOC 21XC Can be used instead of the serial communication interface IL1 IL2 IL3 SPEC 3 + 24 Vdc - Unbalance load (analog out) X1-1 X1-2 X1-3 X1-7 X1-17 X1-18 X1-12 X1-13 X2 Control input BS X1-6 Serial port X1-8 IRF X1-9 Overcurrent contact (SPST,NO) X1-10 Earth-fault contact (SPST,NO) X1-11 Unbalance contact (SPST,NO) X1-14 Common X1-15 I load (analog out) X1-16 Io load (analog out) + - 3 I> Imax-Imin Imax DI HW å SGB 1..3 Io Reset - relays - registers - indicators Reset 1 Alarm Fig. 1 Block diagram and sample connection diagram 5

Ordering :KHQRUGHULQJSOHDVHVSHFLI\ Ordering information Ordering example 1. Type designation and quantity, 5 pieces 2. Order number RS 489 001-AA 3. Rated frequency f n = 50 Hz 4. Special requirements - 2UGHUQXPEHUV Fault indicator The last two letters of the order number indicate the rated frequency f n of the indicator as follows: RS 489 001-AA, BA AA equals f n = 50 Hz BA equals f n = 60 Hz References $GGLWLRQDOLQIRUPDWLRQ Colour brochure Fault indicator User s manual and technical description Fault indicator 1MRS 750021-MDS EN 34 SPEF 1 EN1 ABB Oy P.O. Box 699 FIN-65101 Vaasa, Finland Tel +358 10 224 000 Fax +358 10 224 1094 www.abb.com/substationautomation