Installation Instructions for 45HW & 47HW Electrified Mortise Locks

Similar documents
Installation Instructions for 45H & 47H Mortise Locks

INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

Installation Instructions For The 8850FL Series Mortise eboss

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

OVERVIEW. Mounting Post (2 places) Cylinder Cam. Handing Pin

Entry Mortise Handleset

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

Entry Mortise Lock Set Lever to Lever

No. 059FL. No. 251FL. No. 260FL. No. 305RE. Etruscan Bronze. Florentine Brass. Siena Brass (D) All designs available in these finishes.

Installation Instructions

Tools Required. * When installing on a fire door, please see instructions below. *

Installation Instructions For Profile Series v.g1 Exit Device

Installation Instructions

Where plans come together.

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

Passage Mortise Lock Set Lever to Lever

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

M O R T I S E L O C K S

Door Hardware Installation Instructions. For Assistance Call:

CM5500 COMPUTER MANAGED MORTISE LOCK INSTALLATION MANUAL

Installing Your Electronic Deadbolt

Installation Instructions For Profile Series v.g1 Cylindrical Lock

MORTISE LOCKS LA1Tx7 //DATASHEET

CM5100 COMPUTER MANAGED CYLINDRICAL LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

Tubular Latches. 3 a. Heavy Duty Lever Latches Series HLL Features Ordering String Functions Dummy Mounts Trim Sets Specifications

CM5500 COMPUTER MANAGED MORTISE LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

INSTALLATION INSTRUCTIONS CRL JACKSON

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

Mortise Locks. European Mortise Locks Series EML Features Ordering String Functions Trim Sets European Profile Cylinders Specifications

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

CRCODE-202. Mechanical Lock. Instruction and Programming Manual. Before Installing:

Installation Instructions

Certification Exhibit FCC ID: U4A-SCYPROX2 IC: 6982A-SCYPROX2. FCC Rule Part: IC Radio Standards Specification: RSS-210

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

Mortise Locks. Narrow Mortise Locks Series NML Features Ordering String Functions Trim Sets Cylinders Strikes Specifications

Congratulations! You are now on your way to enriching your life with! Figure #5. Step 5 Install the Dummy Deadbolt. Step 3 Drill the Door

1530(F) Mortise Exit Devices Installation Instructions

INSTALLATION INSTRUCTIONS CRL JACKSON

INSTRUCTIONS FOR HIT TEMPLATE FOR BEST 34H-37H MORTISE LOCK

WD WD7000 Series

TH955 & TH959. Heavy Duty Thumbpiece Trim For use with ED5000 Series Exit Device. Metal, Wood or Composite Doors

Installation Instructions. Installation Type

INSTALLATION INSTRUCTIONS

Installation Instructions. Installation Type

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock. MP9800 Series Multi-Point Lock Wood Doors. Wood Doors ASSA ABLOY.

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

MORTISE LOCK INSTALLATION INSTRUCTIONS

CL4500 Installation Instructions

Stage 2: Preparing the door (read in conjunction with Hole Drilling Options on back of Template).

Adams Rite. Standard & Heavy Duty Deadlatches Series Heavy Duty Deadlatch

INSTALLATION INSTRUCTIONS FOR ARCHITECTURAL VALUE SERIES ELECTRIC DOGGING / ELECTRIC LATCH RETRACTION AND "H" MODELS (HURRICANE) Endcap P/N:

EXIT DEVICE OPERATION FIRE DOOR LABELS, STRIKES AND FRAME SCREWS FOR INFORMATION CALL OR VISIT RITEDOOR.COM

Installation Instructions

Steel Hawk 4300 Electrified Deadlatch (elatch)

INSTALLATION INSTRUCTIONS CRL JACKSON

Bravura. UL Listed Commercial Locksets FORGED. Designs from Great European Homes. Fall 2009

PMR ELECTRONIC LOCK USER GUIDE

Metal Sound Retardant Door Hardware Information Bulletin

TRILENNIUM FULL SCOPE (FS) TEMPLATE INSTRUCTIONS

Installation Instructions 50 (06-09) 1-15/32 15/32 21/32. 1/4-20 x 5/8" FHMS or #14 x 1/2" FHWS 1/16 1/4. Floor Plate

Hookbolt. Non Handed. Flat LH Bevel RH Bevel Radius Radius with Weather-strip. Radius Flat Bevel

INSTRUCTIONS FOR HIT LOCK MORTISER

P USHbutton 500 series

Model 2740B High Security Safe Lock. Installation Instructions. Mounting Considerations:

INSTALLATION INSTRUCTIONS REPLACING EXISTING DEADBOLT ASSEMBLY

Installation Instructions FE6800 Series Multi-Point Lock

Installation Instruction

Shim (2) Supplied. Strike Plate. (3) x 5/8" PFHMS or 10 x 1" PFHWS. Top Latch. (3) x 1/4" PRHMS. Latch Cover. (2) 8 x 3/8" PFH AB SMS

INSTRUCTIONS FOR HIT TEMPLATE FOR SARGENT MORTISE LOCKS

7130(F) Series Mortise Exit Devices Installation Instructions

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions

Tubular Deadbolts. Deadbolt Series HDD Features Ordering String HDD Functions Trim Sets Suggested Specification

33/3550AWDC. Fire-Rated Devices include these. additional. components. 1-Point Latch (LBL) Metal Edge Wrap required for 60 and 90-minute applications

Installation Instructions

Installation Instructions II-2/4/5K-0608

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009)

Hardware Installation. Do this first:

ASSA ABLOY Series Installation Instructions. Regular Arm. Parallel Arm. Top Jamb Mount. Multi-Sized 1 thru 6 Non-Hold Open and Hold Open Models

DB1000 SERIES. Heavy-Duty Tubular Grade 1 Deadbolts. Standard Features. Optional Features. Options

Installation Instructions ED4400, ED4400M & ED4400MA Series Surface Vertical Rod Exit Devices

Sliding Glass Door Assembly and Installation Guide

Security Mortise Locks

3000 Series Exit Devices Premier Product

Hardware Fitting Accessories Bolts

Congratulations! You are now on your way to enriching your life with!

# in 1 Metal Worker Auxiliary Operating Instructions

Heavy-Duty Bypass Track System

CONCEALED VERTICAL ROD PANIC EXIT DEVICE

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock. MP9800 Series Multi-Point Lock Hollow Metal & Aluminum Doors

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUH (HOLD OPEN) ARMS

How To Measure Your Finished Opening

Transcription:

Installation Instructions for 45HW & 47HW Electrified Mortise Locks Contents These installation instructions describe how to install your 45HW & 47HW Electrified Mortise Lock. Topics covered include: Finishing the preparation... Configuring and installing the mortise case... 6 Installing the trim... 8 Finishing the installation...13 J E A B C / D F J E For hole sizes, see the H15 Template (T81163). G H G A Figure 1 Identifying holes to drill Power () Power supply Sensor wires Latchbolt or deadbolt status () Door status () RQE status () Access control panel Temperature control module Wire transfer hinge Lock Wiring diagram for 45HW & 47HW Electrified Mortise Locks 1

Installation Instructions for 45HW & 47HW Electrified Mortise Locks Finishing the preparation Functions Holes by Function TWEL, TWEU, DEL, DEU TDEL, TDEU WEL, WEU LEL, LEU NXEL, NXEU Holes to drill I/S O/S I/S O/S I/S O/S I/S O/S I/S O/S A M & N forged trim ( holes) B J trim C Standard cylinder or D High security cylinder E H, R & S trim thumb turn mounting screw ( holes) F Emergency key / thumb turn access G Trim mounting ( holes) 1 Identify holes to drill 1 Determine the lock function to be installed. Determine the inside and outside, hand, and bevel of the. 3 See the Holes by Function table and Figure 1 on page 1 to determine the holes to be drilled for the lock function. H Lever Determine trim holes based on trim type. To qualify for the UL 437 high security listing, use the M escutcheon and the 1E7J4 cylinder. The 1E7K4 cylinder is available for use with either M trim or sectional trim, but does not qualify for the UL437 high security listing. Because these holes pass through the mortise pocket, it is recommended that each hole be drilled separately rather than straight through. Align templates Door edge template Centerline Figure Strike lip Align to edge of. Low edge (narrow side) High edge (wide side) Hole Descriptions A M & N forged trim () B J trim (1) C Cylinder (1) D High security cylinder (1) E H, R, & S trim thumb turn mounting screw () F Emergency key / thumb turn access (1) G Trim mounting () H Lever (1) J H & R trim visual indicator mounting screw () Horizontal centerline of lever A B G H Note: Use this template for the inside of a LH or LHRB or the outside (keyed side) of a RH or RHRB. For metal s, see the H16 Template Installation Specifications for 45H & 47H Mortise Locks (T81166). A Vertical centerline of lever 5/8 in 16 mm 3/8 in 10 mm 1 1/4 in 3 mm Horizontal centerline of lock 7/8 in 3 mm G 3/8 in 1 3/4 in 45 mm D C J J E F 1/8 in E 1/ in 13 mm Aligning the templates 1/8 in 3 mm 3 mm 10 mm Installation template Centerline Note: If the is a fabricated hollow metal, determine whether it is properly reinforced to support the lock. If reinforcement is not adequate, consult the manufacturer for information on proper reinforcement. For dimensions for preparing metal s, see the H19 Template Installation Specifications for 45HW & 47HW Electrified Mortise Locks (T81611). 1 Separate the 4 templates provided on the H15 Template Installation Template for 45H & 47H Mortise Locks and 45HW & 47HW Electrified Mortise Locks (T81163). Position one of the edge templates on the, making sure that the lock case mortise shown on the template aligns with the mortise pocket prepared in the. 3 Using the centerlines on the edge template as a guide, position the appropriate template on each side of the. You need to take the bevel into account. Tape the templates to the.

1 mortise pocket extension Drill 3/8 dia channel at the base of the pocket Drill 1 dia hole at the base of the pocket TCM (Temperature Control Module) 1 dia x 3 deep hole

Installation Instructions for 45HW & 47HW Electrified Mortise Locks Finishing the preparation 6 Determine wire gauge for power wiring 1 Calculate the total length of the power wire run by summing: The distance from the power supply to the first. If powering more than one daisy-chained to the same power supply, add the total distance of the power runs between the s. For both 1 volt and 4 volt locks, refer to the table below to determine the minimum wire gauge based on the number of s sharing the power supply and the total length of the wire run. 1 s 3 s 4 s Min. wire gauge 50 ft. 15 ft. 75 ft. 60 ft. 18 AWG 400 ft. 00 ft. 130 ft. 100 ft. 16 AWG 600 ft. 300 ft. 185 ft. 150 ft. 14 AWG Field wiring Door frame Figure 7 Running field wiring Door 7 Prepare for wire transfer hinge and run field wiring 1 Drill a wire access hole through the frame side of the hinge mortise where you removed the hinge in Task 4, Step 1 on page 3. Drill holes (or pockets) for splice connectors in the frame and. Refer to the hinge manufacturer s specifications for the hole location. 3 De-burr the holes to prevent damage to the hinge leads. 4 Run the power field wiring from the location for the lock s power supply to the location for the wire transfer hinge. Note: To match the lock s wire color, use yellow for 1 volts DC power and blue for 4 volts DC power. 5 If the lock has an optional status sensor, latchbolt status sensor, deadbolt status sensor, and/or RQE status sensor, run the sensor wiring from the location of the access control panel to the location for the wire transfer hinge. (Continued) 4

Configuring & installing the mortise case Installation Instructions for 45HW & 47HW Electrif ied Mortise Locks To match the sensor wire colors, refer to the table below. Wire Connection 4V Power 1V Power Door Status Sensor Latchbolt Status Sensor RQE Status Sensor Color Blue Yellow White Violet Brown & Orange No. of Wires () Sets - 4 wires* Type Power Power NO NC NO * Only wires used at hinge see Page 6, Step 10, Notes 1 & for explanation Normally Open Normally Closed 7 Pull the field wiring down the wall and through the access hole in the frame. Door status switch Shield 8 Install status switch (optional for deadbolt function locks) 1 Position the shield on the status switch with the notch facing downwards (towards the mortise pocket). Caution: Make sure the wires are not routed across any sharp edges or over any surface that could damage its sleeving. Feed the wires for the status switch into the status switch hole and through the channel into the mortise cavity. 3 Insert the status switch assembly into the status switch hole. Figure 8 Installing the status switch 9 Rotate latchbolt (if necessary) 1 Determine whether you need to rotate the latchbolt to match the handing of the. Note: The angled surface of the latchbolt must contact the strike when the closes. If you need to rotate the latchbolt, insert a flat blade screwdriver into the latch access point approximately 1/ʺ into the case and press to extend the latch out of the case (Figure 9). 3 Rotate the latchbolt past 180 degrees, keeping constant pressure on it. Then allow it to retract into the case. Latch access point Figure 9 Rotating the latchbolt Rotate past 180 degrees, then allow it to retract into the case. 5

Installation Instructions for 45HW & 47HW Electrif ied Mortise Locks Configuring & installing the mortise case 10 Position hub toggles (if necessary) Left Hand (LH) Outside Right Hand (RH) 1 Check whether the hub toggles are in the proper position for the lock (Figure 10). The inside hub toggle should be down (always latched) and the outside hub toggle should be up (lockable). Note 1: For LH & LHRB s, the inside is the back side of the case and the outside is the cover side of the case. For RH & RHRB s, the inside is the cover side of the case and the outside is the back side of the case. The cover is mounted to the case with 4 screws. Note : If the lock has an optional RQE status sensor, two RQE status switches are installed in the mortise case. However, only the switch for the inside of the lock needs to be connected. Before you install the mortise case in the, determine whether you need to connect the Case Side pair of RQE wires (LH & LHRB) or the Cover Side pair of RQE wires (RH & RHRB), based on the handing of the. (See handing chart to the left for reference). Left Hand Reverse Bevel (LHRB) Door handing chart Outside Right Hand Reverse Bevel (RHRB) To change the position of a hub toggle, remove the toggle screw, move the toggle into the desired position, and re-tighten the screw. 11 Connect Temperature Control Module Figure 10 Figure 11 Hub toggle Positioning the hub toggles Mortise case Connect TCM to lock case For more information, see TCM booklet. Hub toggle Mortise cavity TCM Push TCM into this one inch hole Connecting and positioning TCM 1 Connect the Temperature Control Module (TCM) to the lock as shown in Figure 11. Fish the TCM wires through the channel, making sure to position the TCM inside the one inch diameter hole extension at the base of the mortise cavity as shown in Figure 11. See also Figure 4. Note: In some applications (for example fire s), it may not be possible to make extra holes into the. In such scenarios, the TCM may be installed in a secure location at no more than 0 feet from the. 6

Installation Instructions for 45HW & 47HW Electrified Mortise Locks Configuring & installing the mortise case 1 Install mortise case 1 Drill the holes for the case mounting screws. Insert the mortise case into the mortise cavity, feeding all sensor and solenoid wires into the mortise cavity. Note: The armored front of the mortise case self-adjusts to the bevel. 3 From the hinge edge of the, fish all sensor and solenoid wires from the mortise cavity through the wire channel to the hinge mortise. 4 Secure the mortise case with the case mounting screws (Figure 1). 13 Install wire transfer hinge Note: Stanley recommends one of the following concealed electric hinges from Stanley Security Solutions. For more information, contact your Stanley representative. Hinge Description CECB 179-66 Standard weight; steel CECB 168-66 Heavy weight; steel CECB 191-66 Standard weight; brass All hinges measure 4.5 4.5 and have a 6D finish. All hinges have two 4 AWG wires rated for A at 1 or 4 volts (AC or DC) and four 8 AWG wires rated for 1 A at 1 or 4 volts (AC or DC). 1 Trim the power and sensor wires that you pulled through the hinge edge of the. Leave sufficient length to connect to the wire transfer hinge and to allow for future splices. Splice the field wires to the leads on the frame side of the hinge, following the hinge manufacturer s instructions. 3 Splice the power and sensor wires from the lock to the leads on the side of the hinge, matching each lead to its corresponding wire. Note: If the lock has an optional RQE status sensor, splice only the pair of RQE wires for the switch on the inside of the, which you identified in Task 10 on page 6. Put the unused pair of RQE wires in the. Installation Instructions for 45HW & 47HW Electrified Mortise Locks Figure 1 Installing the mortise case Door frame Door Figure 13 Installing the wire transfer hinge Wire transfer hinge 7

Installation Instructions for 45HW & 47HW Electrified Mortise Locks Installing the trim 4 Insert the wires and splice connectors into the holes or pockets in the and frame, being careful not to pinch the wires. Install the wire transfer hinge. 14 Install trim mounting plates Outside mounting plate Inside mounting plate 1 For J trim, position the J alignment plate (Figure 16b) on the outside of the. For all trim, insert the outside trim mounting plate through the and mortise case. 3 Position the inside trim mounting plate opposite the outside trim mounting plate and screw them securely in place. Caution: Do not overtighten the trim mounting plate screws. Overtightening may damage the locking mechanism. Figure 14 Installing the trim mounting plates Cylinder retainer screw 15 Install concealed cylinder (N trim only) 1 Use a cylinder wrench to thread the cylinder into the mortise case so that the groove around the cylinder is even with the surface. Caution: A malfunction can occur if the cylinder is threaded in too far. Secure the cylinder in the mortise case with the cylinder retainer screw. Figure 15 Installing the concealed cylinder 8

Installing the trim Installation Instructions for 45HW & 47HW Electrified Mortise Locks 16 Install roses or escutcheons For sectional trim (Figure 16a) 1 Position the inside rose on the so it is centered on the trim mounting plate. Use the spanner wrench to install the rose ring onto the inside mounting plate. 3 Position the outside rose on the so it is centered on the trim mounting plate. 4 Use the spanner wrench to install the rose ring onto the outside mounting plate. For J trim (Figure 16b) 1 Position the inside escutcheon on the so it is centered on the trim mounting plate. Install the escutcheon screw. Use the spanner wrench to install the trim ring onto the inside mounting plate. 3 Position the outside escutcheon on the over the alignment plate. 4 Use the spanner wrench to install the trim ring onto the outside trim mounting plate. Alignment plate Figure 16a Installing the roses Escutcheon screw Rose ring Rose Trim ring Inside escutcheon Figure 16b Installing the J trim escutcheons 9

Installation Instructions for 45HW & 47HW Electrified Mortise Locks Installing the trim Escutcheon screw Inside escutcheon Trim ring For M trim (Figure 16c) or N trim (Figure 16d) 1 Position the inside and outside escutcheons on the so they are centered on the trim mounting plates. Install the upper and lower escutcheon screws from the inside of the. 3 Use the spanner wrench to install the trim rings onto the inside and outside trim mounting plates. Figure 16c Installing the M trim escutcheons (47H M trim shown) Escutcheon screw Inside escutcheon Trim ring Figure 16d Installing the N trim escutcheons 10

Installing the trim Installation Instructions for 45HW & 47HW Electrified Mortise Locks 17 Install thumb turn or emergency access plate (if necessary) Note 1: Install the thumb turn on the inside of the for the following lock functions: TDEL TDEU LEL LEU Note : Install the emergency access plate on the outside of the for privacy function (LEL and LEU) locks. 1 Orient the thumb turn so it points up when the deadbolt is retracted and towards the hinge edge of the when the deadbolt is extended. Install the thumb turn or emergency access plate using the two screws provided (Figure 17). Thumb turn Figure 17 Installing the thumb turn or emergency access plate 11

Installation Instructions for 45HW & 47HW Electrified Mortise Locks Installing the trim 18 Install standard or high security cylinder (if necessary) Back view of cylinder Set screw location Cam in 1 o clock position Figure 18a Installing the standard cylinder Cylinder retainer screw 1 Using a narrow-blade screwdriver, insert the blade into the cylinder s figure-8 opening and back the set screw into the cylinder until the tip of the set screw is below the threads of the cylinder. Make sure the washer (standard cylinder only) and cylinder ring are positioned on the cylinder. 3 Rotate the cylinder cam to the 1 o clock position. 4 Use a cylinder wrench to thread the cylinder into the mortise case. For a standard cylinder, rotate the cylinder until the cylinder ring is flush against the. For a high-security cylinder, rotate the cylinder until the cylinder head touches the inside rim of the cylinder ring. Caution: A malfunction can occur if the cylinder is threaded in too far. 5 Using a narrow-blade screwdriver, insert the blade into the figure-8 opening and tighten the small set screw (installed in the cylinder) into the lock case. 6 Secure the cylinder in the mortise case with the cylinder retainer screw. Cylinder retainer screw Figure 18b Installing the high-security cylinder 1

Finishing the installation Installation Instructions for 45HW & 47HW Electrified Mortise Locks 19 Install inside and outside levers For standard lever installation (Figure 19) 1 Unscrew the inside spindle one full turn to allow the spindles to turn freely. Note: Remove the label from the inside spindle. With the handle pointing toward the hinges, insert the outside lever and spindle assembly into the lock from the outside of the. Note: The 17 style lever is handed. The lever should curve downward when installed on the. 3 Slide the inside lever onto the inside spindle and secure it with the set screw. 4 Turn the levers to check that they operate smoothly. Spindle assembly Figure 19 Outside of Installing the levers Inside of Location of set screw 0 Install mortise case faceplate 1 Secure the mortise case faceplate to the mortise case with the faceplate mounting screws. Check the lock for proper operation. Figure 0 Installing the mortise case faceplate 13

Installation Instructions for 45HW & 47HW Electrified Mortise Locks Finishing the installation 1 Install strike box and strike plate 1 If the jamb has not been mortised for the strike box and strike plate, perform these steps: a On the jamb, locate the horizontal centerline of the strike (3/8 above the centerline of the lock), as well as the vertical centerline of the strike. b Mortise the jamb to fit the strike box and strike plate. c Drill the holes for the screws used to install the strike box and strike plate. If using a strike box with a magnet (for the optional status sensor), orient the strike box so that the magnet is at the top of the strike box. 3 Insert the strike box into the mortise in the jamb. Place the strike plate over the strike box and secure the strike with the screws provided. 4 Check the position of the auxiliary bolt against the strike plate. Note: The recommended gap between the and jamb is 1/8. Strike box with magnet Magnet Strike plate Strike box Figure 1 14 Installing the strike box and strike plate

Finishing the installation Installation Instructions for 45HW & 47HW Electrified Mortise Locks Install status magnet (optional for deadbolt function locks) 1 On the jamb, mark the drill point for the status magnet hole. Note: This hole should be directly opposite the status switch when the is closed. Drill a 1 diameter hole for the magnet, at least 1 3/4 deep. 3 Insert the magnet into the hole. Door status magnet 3 Install cores 1 For a high-security cylinder, slide the cylinder face down over the core. Insert the control key into the core and rotate the key 15 degrees to the right. 3 With the control key in the core, insert the core and cylinder face (high-security cylinder only) into the cylinder. 4 Rotate the control key 15 degrees to the left and withdraw the key. Caution: The control key can be used to remove cores and to access s. Provide adequate security for the control key. Figure Installing the status magnet Cylinder Core Control key View of high-security cylinder Cylinder face Figure 3 Installing the core(s) 15

Installation Instructions for 45HW & 47HW Electrif ied Mortise Locks Finishing the installation 4 Install lock power supply Determine the power supply requirements for the lock. For a lock with a 1 volt solenoid, use a regulated power supply rated for 1 volts DC at 1.1 amps. For a lock with a 4 volt solenoid, use a regulated power supply rated for 4 volts DC at 0.75 amps. To power more than one lock with the same power supply, sum the total volt-amps (power) for the circuit and then multiply that number by 1.5. This is the minimum power rating in volt-amps recommended for the power supply. Example for two locks powered by one supply: Both locks are rated at 1 volts, 1.1 amps (1 volts x 1.1 amps) + (1 volts x 1.1 amps) = 6.4 volt-amps 6.4 volt-amps x 1.5 = 39.6 volt-amps Choose a power supply with a rating of 39.6 volt-amps or higher. 6 Check operation 1 Supply power to the lock and check its operation. For example, check that: latches and opens properly deadbolt operates properly key access works gap is 1/8 auxiliary bolt is held inside the case when the is closed. When installation of the access control system has been completed, apply power to the system and check that the s sensors operate properly. For assistance, contact your local Stanley representative. 5 Make sensor connections Connect the field wiring for the lock sensors to the access control panel. Refer to the table below and the manufacturer s instructions for the access control panel. Wire Connection 4V Power 1V Power Door Status Sensor Latchbolt Status Sensor RQE Status Sensor Color Blue Yellow White Violet Brown & Orange No. of Wires () Sets - 4 wires* Type Power Power NO NC NO * Only wires used at hinge see Page 6, Step 10, Notes 1 & for explanation Normally Open Normally Closed 006-009 Stanley Security Solutions, Inc. and Stanley Logistics, Inc. T8161/Rev C 1907197 ER-7991-1 Apr 015 16