OVERVIEW. Mounting Post (2 places) Cylinder Cam. Handing Pin

Similar documents
4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

BEFORE STARTING INSTALLATION

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

Installation Instructions

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

LATCHBOLT FILLER PLATE ASA FILLER PLATE A. SINGLE DOOR B. DOUBLE DOOR WITH MULLION C. DOUBLE DOOR WITHOUT MULLION END COVER MOUNTING BRACKET

98/ Customer Service # Dogging Key (use to lock down pushbar)

TH955 & TH959. Heavy Duty Thumbpiece Trim For use with ED5000 Series Exit Device. Metal, Wood or Composite Doors

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

CONCEALED ROD CRASH BAR PR-7085 SERIES EXIT DEVICE ASSEMBLY DETAILS PR mm. 10mm. Lock cylinder. 10mm. Cross bar length (see note #8) Dogging

1800 Series. Flatbar Exit Devices. An ASSA ABLOY Group brand

7130(F) Series Mortise Exit Devices Installation Instructions

INSTALLATION INSTRUCTIONS CRL JACKSON

This is a printable pdf document. For Smartphone-friendly version, tap or click here.

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions

1790 Touchbar. Installation Instructions. Rim Panic Device ININST Index:

Exit Device 5820 SERIES GRADE 1 PUSH BAR SPECIFICATIONS HEAD COVER OPTIONS STRIKES APPLICATION.

ED5200(A) Series Rim Exit Devices

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

MORTISE LOCK INSTALLATION INSTRUCTIONS

Installation Instructions for 45H & 47H Mortise Locks

ED1100 /1100F SERIES RIM EXIT DEVICE INSTALLATION INSTRUCTIONS

55 Series Exit Device

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

An ASSA ABLOY Group brand Series. Flatbar Exit Devices

Shim (2) Supplied. Strike Plate. (3) x 5/8" PFHMS or 10 x 1" PFHWS. Top Latch. (3) x 1/4" PRHMS. Latch Cover. (2) 8 x 3/8" PFH AB SMS

Installation Instructions ED4400, ED4400M & ED4400MA Series Surface Vertical Rod Exit Devices

1530(F) Mortise Exit Devices Installation Instructions

Installation Instructions For The 8850FL Series Mortise eboss

CONCEALED VERTICAL ROD PANIC EXIT DEVICE

INSTALLATION INSTRUCTIONS CRL JACKSON

33/3550AWDC. Fire-Rated Devices include these. additional. components. 1-Point Latch (LBL) Metal Edge Wrap required for 60 and 90-minute applications

FRAME PREPARATION 3900/8900 SURFACE LATCH CONCEALED ROD EXIT DEVICE INSTALLATION INSTRUCTIONS HOW TO FIND BACKSET. Date: Appvd: *13/16 2 3/4" 3/4 HOLE

55 Series. Exit device

EXIT DEVICE OPERATION FIRE DOOR LABELS, STRIKES AND FRAME SCREWS FOR INFORMATION CALL OR VISIT RITEDOOR.COM

ED5200S(A) Series ED5200S(A) Series x M107 Windstorm Series SecureBolt Exit Device

INSTALLATION INSTRUCTIONS CRL JACKSON

1500(F) Rim Exit Devices Installation Instructions

Installation Instructions

2100 series exit devices. rugged reliability

Installing Your Electronic Deadbolt

Entry Mortise Lock Set Lever to Lever

7210 Surface Vertical Rod Exit Device Installation Instructions. Outside Trim

Installation Instructions for 45HW & 47HW Electrified Mortise Locks

Metal Sound Retardant Door Hardware Information Bulletin

CRCODE-202. Mechanical Lock. Instruction and Programming Manual. Before Installing:

88 Series. Exit device

* * 22 & 22-F. Please give these instructions to building owner after device is installed BS EN 1125 : 2008

3000 Series Exit Devices Premier Product

* * 9875/ Customer Service #10-24 # Dogging Key (use to lock down pushbar)

7100(F) series. A conventional exit device for single swing doors or pairs of doors of metal, wood or composite construction.

Monarch XX Series. Crossbar Exit Device

Passage Mortise Lock Set Lever to Lever

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK

7100(F) series. A conventional exit device for single swing doors or pairs of doors of metal, wood or composite construction.

8000 SERIES SERIES HEAVY-DUTY MODELS

Introduction Exit Hardware Rim device... 4 Surface mounted vertical rod device... 6 Mortise lock device... 5

88 Series. Exit device

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

1.8. Panic Exit Devices. ED22 Series, ED2227 Series, ED22M Series, Accessories and Parts. Mechanics

ED5200(A) Series Rim Exit Devices

Entry Mortise Handleset

ED3000 Series. Exit Device Parts Manual

CL4500 Installation Instructions

7100(F) series. A conventional exit device for single swing doors or pairs of doors of metal, wood or composite construction.

WD WD7000 Series

CM5500 COMPUTER MANAGED MORTISE LOCK INSTALLATION MANUAL

CM5500 COMPUTER MANAGED MORTISE LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK

Installation Instructions For Profile Series v.g1 Exit Device

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock. MP9800 Series Multi-Point Lock Wood Doors. Wood Doors ASSA ABLOY.

Installation Instructions II-2/4/5K-0608

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock. MP9800 Series Multi-Point Lock Hollow Metal & Aluminum Doors

WOOD DOOR INSTALLATION

Door Hardware Installation Instructions. For Assistance Call:

Hookbolt. Non Handed. Flat LH Bevel RH Bevel Radius Radius with Weather-strip. Radius Flat Bevel

INTELLIKEY. Lock Identification GENIUS AT YOUR FINGERTIPS. 1 rev:

Tools Required. * When installing on a fire door, please see instructions below. *

376E Series Exit devices

INSTALLATION INSTRUCTIONS REPLACING EXISTING DEADBOLT ASSEMBLY

INSTALLATION INSTRUCTIONS FOR ARCHITECTURAL VALUE SERIES ELECTRIC DOGGING / ELECTRIC LATCH RETRACTION AND "H" MODELS (HURRICANE) Endcap P/N:

1510(F) Surface Vertical Rod Exit Devices Installation Instructions

Endcap P/N: X. Endcap Bracket P/N: Endcap Bracket with 9V battery holder P/N: Fillerplate SubAssembly

No. 059FL. No. 251FL. No. 260FL. No. 305RE. Etruscan Bronze. Florentine Brass. Siena Brass (D) All designs available in these finishes.

930 Series Mortice Exit Device

Installation Instructions for Deadbolt Models OP 8102LT

Shetland Stalls Installation Instructions

CrossOver X25 Lock Installation Need another copy of these installation sheets? You can download one at

Adams Rite. Standard & Heavy Duty Deadlatches Series Heavy Duty Deadlatch

Cross bar. Exit devices

Transcription:

DEVICES COVERED IN THIS DOCUMENT: 46CE Cylinder Escutcheon Key locks and 46DT Dummy Trim Pull when dogged unlocks lever 46BE Blank Escutcheon Always operable 46NL Night Latch Key retracts latchbolt 46NK Night Lever (09 Function) Lever operable when key is turned. Key removable only when locked. OVERVIEW (46CE Cylinder Escutcheon Shown) Cylinder Collar Cylinder Nut Mounting Post (2 places) Cylinder Cam Mortise Cylinder Lever Handle Handing Pin Adjustable Tailpiece 46CE Cylinder Escutcheon Key Locks & Unlocks Levers Requires a mortise cylinder (3902) and L Cam (3976) with radius 0.637 (16mm). Both sold separately. 46NK Night Lever Lever Operable When Key Is Turned. Key Removable Only When Locked Requires a mortise cylinder (3902) and L Cam (3976) with radius 0.637 (16mm). Both sold separately. 46BE Blank Escutcheon Always Operable 46DT Dummy Pull When Exit Device Is Dogged 46NL Night Latch Key Retracts Latchbolt Requires a RIM cylinder (3901) and extra long tailpiece (2-639-7058). Both sold separately. Rev 2, Rev Date: 2/4/2014 27390048 Page 1 of 5

APPLICATIONS 4950 BLADE STOP STRIKE SINGLE DOOR 4920 STANDARD STRIKE SINGLE DOOR 4950 Blade Stop Strike Application Single Door Panic Exit Hardware 4920 Standard Strike Application (4920F Strike Available for Fire Rated Applications) 4920 STANDARD STRIKE AND MULLION 4952 SEMI-FLUSH STRIKE AND MULLION 4920 Standard Strike Application (4912 strike available for fire-rated applications) 4952 Semi-Flush Strike Application TOOLS REQUIRED Rev 2, Rev Date: 2/4/2014 27390048 Page 2 of 5

1. SET TRIM HANDING A. Rotate lever handle to the right or left direction to match the desired door handing. B. Align the handle for the desired door handing position and then insert the square handing pin into the trim escutcheon as shown below. Square Handing Pin Left Hand Reverse (LHR) shown 2. INSTALL MORTISE CYLINDER (for CE and NK trim only) A. Install mortise cylinder into collar and escutcheon trim. B. From the back of the trim escutcheon Cylinder Nut screw cylinder nut onto mortise cylinder until secure. 5/8 Collar Test Installation (CE trim only) Insert the key and rotate counterclockwise. Turn the lever handle and observe the tailpiece. It should be unlocked and the tailpiece will rotate. Rotate the key clockwise to lock the trim. Verify that the tailpiece does not rotate when the handle is turned. Test Installation (NK trim only) Insert the key and rotate counterclockwise. While keeping the key rotated, turn the lever Handle and observe the tailpiece to see if it has rotated. The handle should cause the tailpiece to turn only when the key remains turned. Release the key. Rotate the lever handle and confirm that the tailpiece is not turning. 46CE Cylinder Escutcheon Mortise Cylinder Part # 3902 with 3976 Cam R 0.637 (16mm) (Ordered separately) Rev 2, Rev Date: 2/4/2014 27390048 Page 3 of 5

Note A 3. INSTALL NIGHT LATCH RIM CYLINDER (for NL trim only) A. Replace standard length tailpiece with extra-long tailpiece (2-3/8 ). B. Install rim cylinder into collar and escutcheon trim. C. Install cylinder mounting bracket from back side of escutcheon trim as shown below. D. Adjust break-off screws to eliminate excess length and secure rim cylinder. E. Insert key and rotate. Observe the back of the trim and verify that the tailpiece rotates. 4600 Series Narrow Stile Trim #12-24 Break-off screws 46NL Night Latch 5/8 Collar RIM Cylinder Part No. 3901 & Extra Long Tailpiece Part # 2-639-7058 (Both Sold Separately) Cylinder Mounting Bracket 4. DRILL MOUNTING HOLES FOR ESCUTCHEON TRIM A. Mark horizontal centerline by matching it to exit device centerline, which can be found on the push side of the door. B. Mark vertical centerline by matching it to exit device centerline, which can be found on the push side of the door. Refer to Applications section on page 2 to determine the location of the vertical centerline. C. Apply template to door using centerlines. D. Mark and drill holes as shown below. i. Note that the mounting holes are the same for all functions but the tailpiece clearance hole is different depending on function. Note: Available templates include T-ED01194 4600 Trim Template (BE, CE,DT) and T-ED01195 46NL Trim Template Door Stile (Pull Side) Note B Note C Frame Note A Notes: A. Trim centerline corresponds to exit device centerline. B. Trim mounting clearance holes (2 places): i. Drill ø 1/2 [13] holes on pull side. ii. Drill ø 5/16 [8] holes on push side. C. Trim tailpiece clearance hole: i. For CE, NK and BE functions: 1. Drill ø 3/4 [19] hole on pull side. 2. Drill ø 1/2 [13] hole on pull side. ii. For NL function, drill ø 1/2 [13] thru hole. iii. Not required for DT function. Rev 2, Rev Date: 2/4/2014 27390048 Page 4 of 5

2-1/2 1-3/4 (Factory preset 3 2-1/4 2 4600 Series Narrow Stile Trim 5. ADJUST TELESCOPING ACTUATING SHAFT (for BE, CE and NK trim only) A. The telescoping actuating shaft is preset at the factory for a 1-3/4 thick door. For thicker door applications follow these steps: i. Remove the small screw on the side of the actuating shaft and keep it handy for the next step. ii. Use the chart below to choose the appropriate setting for your door application. For other door/shim kit thicknesses, use the closest larger size. iii. Slide the center shaft out until it lines up properly with the setting you chose in the last step. iv. Replace the screw and secure. v. Check for proper engagement with the exit device in the next step. Telescoping Actuating Shaft Remove Screw Adjust Shaft Length Preset Door Thickness Positions For Telescoping Actuating Shaft Replace Screw 6. INSTALL ESCUTCHEON TRIM A. Insert trim mounting posts and actuating shaft through door. B. Mate trim actuating shaft with cam on back of exit device. C. Secure from push side of door with provided ¼ -20 machine screws. D. Test installation by rotating lever handle or key to 46CE Cylinder Escutcheon verify trim functions properly. Door Stile ¼ -20 Mounting Screws 4600 Narrow Stile Exit Device Rev 2, Rev Date: 2/4/2014 27390048 Page 5 of 5