7RU SSPA Chassis. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

Similar documents
300W C-Band Second Generation 3RU SSPA Chassis with 1RU N+1 Power Supply

500W X-Band, 1:2 Redundant System in the 4RU chassis, with N+1 redundant power supplies

125W Ku-Band Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

800W C-Band Second Generation 3RU SSPA Chassis with 1RU N+1 Power Supply. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

150W Ku-Band Compact Outdoor 1:1 Redundant System. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

400W C-Band GaN Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

500W X-Band, 1:2 Redundant System in the 4RU chassis, with N+1 redundant power supplies

40W Ka-Band Compact Outdoor SSPA with AC Input Option B

High Power Outdoor. GaAs Solid State Power Amplifiers

400W C-Band GaN Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

High Power Outdoor. GaN Solid State Power Amplifiers

Indoor Rack Mount. GaN Solid State Power Amplifiers 3RU Rack Height

4RU Rack Mountable. Solid State Power Amplifiers

The New Standard in Outdoor High Power Redundant Microwave Amplifier Systems Has Arrived. Removable fan trays System is 100% field maintainable

The New Standard in Outdoor High Power Redundant Microwave Amplifier Systems Has Arrived. dundancy System Monitor and Control.

Phase Combined Systems

The New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived

High Power Outdoor. GaN Solid State Power Amplifiers

The New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived

The New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived

Compact Outdoor Solid State Power Amplifiers in S-, C-, X-, and Ku-Bands

328 Innovation Blvd. 1 Wheaton Road, Witham

328 Innovation Blvd. 1 Wheaton Road, Witham

Mini Compact Outdoor GaN SSPAs in C-, X-, and Ku-Bands

328 Innovation Blvd. 2&3 The Matchyns, London Road, Rivenhall End

Ku-Band VSAT Block Up Converters

C-Band VSAT Block Up Converters

MT3200A TRAVELING WAVE TUBE MEDIUM POWER AMPLIFIER

VSAT Redundant System Solutions

FEATURES: Reduced Depth. Output RF Power Hold. Easily Accessible Diagnostic Port. Programmable Alarms. Event And Maintenance Logs. Ethernet Interface

C-Band Redundant LNA Systems

X-Band Redundant LNA Systems

Ku-Band. Reliable Designed and built to survive in extremely adverse environmental conditions. Operates in ambient temperatures up to 60 C.

KU-BAND OUTDOOR BLOCK CONVERTERS

PowerMAX Redundant SSPA Systems. Soft-fail Redundancy Modular, Hot-swap Assemblies Indoor and Outdoor Packages

STA3318 Series StellarMini TM 180 W, Ku-Band Antenna Mount TWTA

INTRODUCTION STANDARD FEATURES. Option: High ambient temperature operation (up to 60 C) APPLICATION KU-BAND BOOSTER AMPLIFIER

Universal/Standard Ku-band 8W BUC MODEL No. NJT8318 series

1:1 AND 1:2 REDUNDANT LOW-NOISE AMPLIFIER SYSTEMS

Block Upconverters for Integration in High Power Amplifiers

J kw AM Transmitter

Universal/Standard Ku-band 8W BUC MODEL No. NJT8318 series

Universal/Standard Ku-band GaN 40W BUC MODEL No. NJT8371 series

Redundant LNA Systems

Standard C-band 10W BUC MODEL No. NJT5762 series

100U1000. Features. 100 watts CW 100kHz 1000MHz Class A Portable Full VSWR tolerant CE & RoHS Compliant High Efficiency

PARADISE DATACOM APPLICATION NOTE. Satellite Terminal System Planning using L Band Modems. AN_032 Issue 2

150W1000B. Features. 150 watts CW 80MHz 1000MHz Class A Portable Full VSWR tolerant CE & RoHS Compliant High Efficiency

Features 100A400AM20. 4kHz 400MHz Class A Portable Full VSWR tolerant CE & RoHS compliant High Efficiency

Universal/Standard Ku-band 16W BUC MODEL No. NJT8319 series

Solid State General Communication Power Amplifier

Solid State Broadband High Power Amplifier

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

Optiva OTS-2 18 GHz Amplified Microwave Band Fiber Optic Links

Ka-Band SSPA TSA GHz Airborne Applications

Digital Microwave Radios

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

NA100 NA200 NA300. NA Series Frequency Agile Medium Wave Broadcast Transmitters

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

Engineering the high quality cost effective solutions. Short form selection catalogue

Amplifier HF MHz

Keysight Technologies N9320B RF Spectrum Analyzer

Agilent N9320B RF Spectrum Analyzer

Continental's 816R -5B, 35 kw Single Tube Broadcast Transmitter. Includes the 802A solid -state exciter

IQgig-RF TM Model B Technical Specifications

Instruction Manual for Universal Ku-band 8W BUC [NJT5218 series]

Amplifier Systems. Ultra Low Noise LNAs. Back to. C-band LNAs X-band LNAs Ku-band LNAs

Scalable Ionospheric Analyser SIA 24/6

LNS ultra low phase noise Synthesizer 8 MHz to 18 GHz

1 KW TOTALLY SOLID STATE DIFFERENTIAL GPS TRANSMITTER ( khz)

SIR-4011 MICROWAVE WIDEBAND DSP RECEIVER. WIDE FREQUENCY RANGE: GHz

XR kw AM Medium Wave Broadcast Transmitter

Series OLH10KD 10kW HIGH VOLTAGE POWER SUPPLIES

120W UHF Transmitter/Repeater

INSTALLATION AND OPERATING MANUAL

khz to 2.9 GHz Spectrum Analyzer

8101 SPECIFICATION SHEET

High Power Amplifier, Solid State, Broadband MHz, 51dB Gain, SMA Female Connectors, 1dB GCP. RAMP M-51d-Sf-80W-e7

No. 1. BROADBAND RF-POWER-AMPLIFIERS 10 khz - 6 GHz. For immunity tests according to IEC, EN, ISO, SAE, MIL

2 GHz to 6 GHz, 500 W Power Amplifier HMC8113

RF Amplifier Data Sheet. BT02000-AlphaA-100ms 10kHz-3MHz 2kW. Scientific and Industrial Applications

Data Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved

TELEDYNE MICROWAVE SOLUTIONS. Summary. NF v1. the carrier (10MHz

The DR-2000 is a high-performance receiver designed to enable highly sophisticated data and signal processing over a wide frequency spectrum.

5199 SCA5000-FM-A0. Efficiency: 58% Temperature Range: 0 to 55 C Max VSWR: 3: Watts CW. Class:

Converter VSAT Dual Band BDC ITAR Free Airborne Compact Block Down Converter MFC146

RF Amplifier Data Sheet. BT01000-Gamma 5MHz-400MHz 1kW. Scientific and Industrial Applications

SATELLITE GROUND SEGMENT

5191 SCA3000-FM-A Watts CW. Efficiency: 68% Temperature Range: 0 to 55 C Max VSWR: 3:1. Class:

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.

RF Amplifier Data Sheet. BT00100-AlphaA-CW 10kHz-1MHz 100W. Scientific and Industrial Applications

Digital HF Receiver WJ-8723

TECHNICAL DESCRIPTION

DSA700 Series Spectrum Analyzer

Chapter 5 Specifications

RF Amplifier Data Sheet. BT00500-AlphaSA-CW 0.5MHz-150MHz 500W. Scientific and Industrial Applications

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

Ka Band Radar Transceiver

Series OLS10KD 10kW HIGH VOLTAGE POWER SUPPLY

2026Q CDMA/GSM Interferer MultiSource Generator

Transcription:

FEATURES DESCRIPTION 7RU SSPA Chassis Teledyne Paradise Datacom s 7RU Indoor, High Power Rack Mount series of SSPAs represent the industry s highest power density and most reliable high power amplifier systems. The High Power Rack Mount SSPA employs a modular design, which allows quick and easy replacement in the event of a catastrophic failure of one of the SSPA components. These modular assemblies include: hot-swap SSPA modules, front and rear fan trays; and a rear panel controller card. These amplifiers are powered via a separate power supply chassis. The power supply is configured as a n+1 redundant, hot swappable, power supply comprised of up to four modules. The power supply is configured such that one module is redundant. In the event of a single power supply module failure, the HPA system will not fail. The power supply module can then be changed without ever taking the HPA out of service. Extremely High Power Density: to 1.1 kw C-Band; to 1000W X-Band; to 500W Ku-Band. Hot Swap, n+1 Redundant Power Supply Power Factor Corrected Power Supply Modular (soft-fail) Architecture Removable fan assemblies Ethernet Port RF Output Sample Port Built-in 1:1 Redundancy Control Built-in Maintenance Switch Controller OPTIONS Extended Frequency Band L-Band Input Reflected Power Monitor Phase Combined Systems Remote Control Panel RF Input Sample Port Rear Panel Air Intake and Exhaust SPECIFICATIONS SSPA Chassis housing: 7 Rack Units (RU) 19.0 X 12.22 X 30.0 in 483 X 310 X 762 mm 180 lbs / 82 kg 1RU Power Supply: 19.0 X 1.75 X 16.1 in 483 X 44 X 409 mm 29 lbs / 13 kg Gray powder coat finish Operating temperature: 0 to +50 C Teledyne Paradise Datacom Teledyne Paradise Datacom Ltd. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End State College, PA 16803 www.paradisedata.com Witham, Essex CM8 3HA United Kingdom Tel: (814) 238-3450 Tel: +44(0) 1376 515636 Fax: (814) 238-3829 Fax: +44(0) 1376 533764 1 OF 7

Power Specifications BAND PARAMETER NOTES LIMITS UNITS Frequency Range (see options for extended band) 5.850 to 6.425 GHz C-BAND X-BAND Output Power @: Saturation/P 1 (Typical/Guaranteed minimum) Power Requirements Line Frequency Power Factor Line Power (Voltage) (typical @ 220 VAC) HPAC7800ARXXXXX HPAC7900ARXXXXX HPAC711KARXXXXX HPAC7800ARXXXXX HPAC7900ARXXXXX HPAC711KARXXXXX P sat / P 1 59.0 (800) / 58.0 (630) 59.5 (900) / 58.5 (700) 60.4 (1100) / 60.0 (1000) 47 to 63.90 4150 (180 to 265) 4850 (180 to 265) 6000 (180 to 265) m (W) m (W) m (W) Hz Frequency Range 7.9 to 8.4 GHz Output Power @: Saturation/P 1 (Typical/Guaranteed minimum) Power Requirements Line Frequency Power Factor Line Power (Voltage) (typical @ 220 VAC) HPAX7700ARXXXXX HPAX710KARXXXXX HPAX7700ARXXXXX HPAX710KARXXXXX P sat / P 1 58.5 (700) / 58.1 (650) 60.0 (1000) / 59.5 (900) 47 to 63.90 5500 (180 to 265) 6000 (180 to 265) m (W) m (W) Hz Frequency Range (see options for extended band) 14.0 to 14.5 GHz KU-BAND Output Power @: Saturation/P 1 (Typical/Guaranteed minimum) Power Requirements Line Frequency Power Factor Line Power (Voltage) (typical @ 220 VAC) HPAK7250ARXXXXX HPAK7400ARXXXXX HPAK7500ARXXXXX Power Factor Corrected HPAK7250ARXXXXX HPAK7400ARXXXXX HPAK7500ARXXXXX P sat / P 1 54.0 (250) / 53.0 (200) 56.0 (400) / 55.0 (300) 57.0 (500) / 56.0 (400) 47 to 63.90 2200 (180 to 265) 4600 (180 to 265) 5100 (180 to 265) m (W) m (W) m (W) Hz Extended C-Band 5.850 to 6.725 GHz 5.750 to 6.670 GHz Options De-rate power by 1.0 linearly from 6.425 to 6.725 GHz De-rate power by 1.0 linearly from 6.425 to 6.670 GHZ and by 0.5 from 5.750 to 5.850 HPAC7XXXBRXXXXX HPAC7XXXCRXXXXX Extended Ku-Band 13.75 to 14.5 GHz De-rate power by 1.0 linearly from 13.75 to 14.0 GHz HPAK7XXXBRXXXXX Reflected Power Monitor See Configuration Matrix RF Input Sample Port (-10 ) See Configuration Matrix 2 OF 7

Gain Gain Flatness General Specifications: 7RU RM Series PARAMETER NOTES LIMITS UNITS Gain Slope Gain Variation vs. Temperature Gain Stability Gain Adjustment minimum full band Extended C-Band units per 40 MHz 0 C to +50 C at constant temperature 0.1 resolution 75 ± 1.0 ± 1.5 ± 0.3 ± 1.0 ± 0.25 20 /40 MHz /24 hours Intermodulation Distortion 3 back off relative to P 1-25 c AM/PM Conversion (@ rated P 1 ) (@P 1-3 ) Spurious Harmonics Input/Output VSWR (@ rated P 1 ) (@ rated P 1-3 ) 3.5 0.5-65 -50 All units except Extended C-Band 1.30:1 Extended C-Band units 1 1.50:1 Noise Figure at maximum gain 12 Group Delay (per 40 MHz segment) Noise Output Residual AM Noise Phase Noise Size HPA Chassis Linear Parabolic Ripple TX Band RX Band (C- or Ku-Band) RX Band (X-Band) 0-10 KHz 10 KHz - 500 KHz 500 KHz - 1 MHz Mechanical width X height X depth 0.01 0.003 1.0-75 -150-100 -45-20 (1.25 + log F) -80 IESS 308/309-10 19.0 X 10.47 X 30.0 483 X 266 X 762 Power Supply Chassis width X height X depth 19.0 X 1.75 X 16.1 483 X 44 X 409 Weight HPA Chassis Power Supply Chassis (1RU) 180 (82) 29 (13) / / c c ns/mhz ns/mhz 2 ns p-p W/4 KHz W/4 KHz W/4 KHz c c c inches mm inches mm lbs.(kg) lbs.(kg) Finish powder coat Gray Environmental Operating Temperature Ambient 0 to +50 C Storage Temperature Ambient -20 to +75 C Operating Relative Humidity Non-condensing 95 % Storage Relative Humidity Non-condensing 90 % Cooling System Integrated Forced air Operational Altitude From sea level +10,000 (+3,048) ft. (m) 1 Extended C-Band units may meet 1.30:1 as a special option. Discuss with your sales representative. 3 OF 7

Monitor & Control (J7) Parallel Port Outputs Power Supply Fault Auxiliary Fault Mute BUC Fault Temperature Fault Voltage Fault DC Current Fault Low RF Fault Monitor & Control (J7) Parallel Port Inputs Mute Input Local / Remote Fault Clear Standby Select Auxiliary Fault Main Serial Port (J4) Auxiliary Serial Port (J5) Link Port (J8) Switch Port (J3) Connectors Interface Specifications; 7RU RM Series PORT NOTES LIMITS PIN-OUT RS232 / RS485 DB9 (F) RS232 / RS485 DB9 (F) 1:1 Redundant System Control Link DB9 (F) Redundant Switch Control Molex (43810-0002) RS232 Out, RS485 TX- RS232 In, RS485 RX- RS485 RX+ RS485 TX+ Service Request 1 Service Request 2 Service Request Common Termination RS232 In, RS485 RX- RS232 Out, RS485 TX- RS232 DTR, RS485 TX+ RS485 RX+ Termination RS485+ RS485- Link Out Link In +28 VDC RF Switch 1, pos 1 RF Switch 1, pos 2 RF Switch 2, pos 1 RF Switch 2, pos 2 Program Port (J6) Flash Firmware Program Port DB25(F) - Ethernet Port (J9) RJ45 TX+ TX- RX- RX+ RF Input, Input & Output Sample RF Output HPAK7XXXR HPAC7XXXR HPAX7XXXR Line Power Type N WR75 Waveguide WR137 Waveguide WR112 Waveguide (3) IEC feeds Pin 4 Pin 1 Pin 6 Pin 8 Pin 7 Pin 9 Pin 4 Pin 1 Pin 9 Pin 1,4,3 Pin 6,7 Pin 8,9 Pin 1,4 Pin 6 Pin 1 Pin 6 Pins 4,5,7,8 Female Grooved (PBR-120) CPR137G flange CPR112G (PDR-84) Plug 4 OF 7

Power Supply Options At all power levels, the 7RU Chassis is fitted with the standard 1RU, four-module power supply configuration. Hot-Swap SSPA Modules Four SSPA modules are phase combined inside the 7RU Rack Mountable SSPA to produce the amplifiers total output power. Each of the SSPA modules is hot-swappable, allowing the unit to remain in service while a failed SSPA module is replaced. The chassis front panel is removable to access the SSPA modules, even while the unit is in operation. 5 OF 7

L-Band Operation Teledyne Paradise Datacom amplifiers are available with an integrated L-Band Block Up Converter. L-Band units utilize Teledyne Paradise Datacom s proprietary zbuc technology. The addition of a zbuc converter to the SSPA typically increases the gain by 2-4. The advantages of zbuc technology include: zbuc converter can detect and switch to an extenally supplied reference. Optional internal high stability (10MHz) reference. zbuc converter can lock to an externally supplied reference of 10 or 50 MHz. zbuc converter can accept a wide range of external reference power (-10 to +5 m). Electrical Specifications for 7RU RM SSPA with ZBUC converter PARAMETER NOTES LIMITS UNITS Gain Gain Flatness Gain Slope Gain Adjusted Range Gain Stability Phase Noise Spurious Nominal setting full band (C-,X-,Ku-bands) per 40 MHz (C-,X-,Ku-bands) Typical C-Band Adj. Range Typical Ku-Band Adj. Range -40 to +60 C Offset frequency from carrier 10 Hz 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz Available Frequency Plans Band Frequency Plan IF Input LO Frequency RF Output C Sub-Band A 950-1525 MHz 4.900 GHz 5.850-6.425 GHz C Sub-Band B 950-1825 MHz 4.900 GHz 5.850-6.725 GHz C Sub-Band C 950-1870 MHz 4.800 GHz 5.750-6.670 GHz C Sub-Band E 950-1250 MHz 5.475 GHz 6.425-6.725 GHz C Sub-Band F 950-1250 MHz 5.775 GHz 6.725-7.025 GHz C Sub-Band G 950-1675 MHz 4.800 GHz 5.750-6.475 GHz X Sub-Band A 950-1450 MHz 6.950 GHz 7.900-8.400 GHz Ku Sub-Band A 950-1450 MHz 13.050 GHz 14.00-14.50 GHz Ku Sub-Band B 950-1700 MHz 12.800 GHz 13.75-14.50 GHz Absolute max. -30-60 -70-80 -90-90 In-Band Signal Related (C-/Ku-Band) (Extended C-Band) Close to Carrier Spurious ( 20 MHz) Local Oscillator C-band (typ.) -60-74 -84-100 -105-125 75 ± 2.0 ± 0.5 20 60-80 57-77 ± 1.5 X-band (typ.) -58-70 -80-94 -97-122 -50-40 -50-30 Ku-band (typ.) -56-67 -78-91 -94-120 /40 MHz c/hz c/hz c/hz c/hz c/hz c/hz c c c m Noise Figure At Maximum gain 20 Transmit Band Noise Output Power Density Tx Band at Maximum gain -65 W/4kHz Input VSWR L-Band 1.5 : 1 Internal Reference Option Reference Accuracy (initial) Aging per day (after 30 days) ± 1 10-8 ± 1 10-9 Aging per year (after 30 days) ± 6 10-8 Reference Stability over Temperature (-40 to +40 C, ambient) ± 1 10-8 6 OF 7

Band C - C-Band X - X-Band K - Ku-Band HPA Part Number Configuration Matrix 7 R X Configuration Modifier 3 X = Standard E 1 = Rear Panel Exhaust Adapters 1 Not available with package options Y and Z. Power Level (in Watts) C-Band 800, 900, 1100 (11K) X-Band 700, 1000 (10K) Ku-Band 250, 400, 500 Frequency Sub Band C-Band A* - 5.850-6.425 GHz B* - 5.850-6.725 GHz C* - 5.750-6.670 GHz E* - 6.425-6.725 GHz (Palapa) F* - 6.725-7.025 GHz (Insat) G* - 5.750-6.475 GHz X-Band A* - 7.90-8.40 GHz B - 7.50-8.50 GHz C - 9.50-10.50 GHz D - 7.70-8.40 GHz Ku-Band A* - 14.00-14.50 GHz B* - 13.75-14.50 GHz * Available with optional BUC Configuration Modifier 2 X = Standard V = Reflected Power Monitor Configuration Modifier 1 D = Redundant 1RU Power Supply E = Redundant 1RU Power Supply & Input Sample Port System Configuration X = Standalone See the following datasheets system options: Redundant SSPA Systems (203583) Phase Combined SSPA Systems (203584) Block Up Converter M = Internal Reference P = External Reference X = N/A Package R = Rack Mount (Standalone) Example - A standalone 800W C-Band high power rack mount SSPA operating at 5.85 to 6.425 GHz, with a 1RU redundant power supply and optional input sample port is part number: HPAC7800ARXXEXX. Use and Disclosure of Data The items described herein are controlled by the U.S. Government and authorized for export only to the country of ultimate destination for use by the ultimate consignee or end-user(s) herein identified. They may not be resold, transferred, or otherwise disposed of, to any other country or to any person other than the authorized ultimate consignee or end-user(s), either in their original form or after being incorporated into other items, without first obtaining approval from the U.S. government or as otherwise authorized by U.S. law and regulations. Proprietary and Confidential The information contained in this document is the sole property of Teledyne Paradise Datacom. Any reproduction in part or as a whole without the written permission of Teledyne Paradise Datacom is prohibited. Specifications are subject to change without notice. 7 OF 7