SET. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023

Similar documents
Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023

URV. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023

ITEM. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023

Smart Field Communicator SET URV ITEM. Can be ordered separately see specification 34-ST-03-55

LGP Design. Can be ordered separately see specification 34-ST-03-55

URV LRV. Smart Field Communicator. Can be ordered separately see specification 34-ST-03-55

ST 3000 Smart Transmitter

ITEM. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023

LGP Design. Can be ordered separately see specification 34-ST-03-55

ST 3000 Smart Transmitter Series 100 Gauge Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /04

Specification and Model Selection Guide. Introduction 34-ST /04

ST 3000 Smart Transmitter Series 100 Remote Diaphragm Seals Models. Specification and Model Selection Guide. Introduction 34-ST /04

ST 3000 Smart Pressure Transmitter Series 900 Differential Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /24/06

ST 3000 Smart Transmitter Series 900 Remote Diaphragm Seals Models. Specification and Model Selection Guide. Introduction 34-ST /2002

LGP Design. Can be ordered separately see specification 34-ST-03-55

ST 3000 Smart Transmitter Series 900 Remote Diaphragm Seals Models. Specification and Model Selection Guide. Introduction 34-ST /04

ST 3000 Fieldbus Transmitter Series 100 Models

SFC Smart Field Communicator Model STS103. Specification 34-ST /24/06. Description. Function. Page 1 of 5

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Wireless Pressure Transmitter Differential Pressure Models Series XYR 6000 Specifications

Wireless Transmitter Gauge Pressure Models Series XYR 6000 Specifications

Specification and Model Selection Guide 34-ST /2003

Specification and Model Selection Guide. Introduction 34-XY /13/07

XYR 6000 Wireless Transmitter Absolute Pressure Model. Specification and Model Selection Guide. Introduction 34-XY /13/07

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor

Wireless Transmitter Series XYR 6000 Absolute Pressure Model STAW94L 0 to 500 psia 0 to 35 bara Specifications

PAD - Heavy Duty Differential Pressure Trasmitter

SmartLine. STR800 SmartLine Remote Diaphragm Seals Specification 34-ST Technical Information. Introduction

XYR 6000 Wireless High Level Analog Input Transmitter Model STIW600 0 to 5 Volts 1 to 5 Volts 0 to 20 ma 4 to 20 ma

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

Specifications. Range 5. ±0.075% of span. URL % of Span ± ±0.04% of span. Ranges 2-4. ±0.04% of span

ST 3000 Smart Transmitter Series 100 Flange Mounted Liquid Level Models. Specification and Model Selection Guide. Introduction 34-ST /08

A New Generation of Pressure Transmitters

Rosemount 2088 Absolute and Gage Pressure Transmitter A TRADITION OF EXCELLENCE IN PERFORMANCE FROM THE INDUSTRY LEADERS

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

Field IT 2600T Series Pressure Transmitters

Specification and Model Selection Guide. Introduction 34-XY /14/07. Figure 1 XYR6000 Temperature Transmitters

Smart Pressure Transmitter

General Specifications

A New Generation of Pressure Transmitters

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610f

Specification and Model Selection Guide. Introduction 34-ST /07

General Specifications

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

Rosemount 3101, 3102, and 3105

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

SmartLine Non-Contact Radar Level Meter Technical Datasheet. Specification. The Universal Radar Solution. Highlights. Industries.

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Wireless Multi Discrete Input Transmitter Series XYR 6000, Model STXW500 Specifications

PTG series Smart Pressure Transmitter

Accutech DP20. Wireless differential pressure field unit

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Wireless Base Radio. Wireless Transmitters

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

11A Series Absolute Pressure Transmitters

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

ST 3000 Smart Pressure Transmitter Series 900 Differential Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /08

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

STT 3000 Smart Temperature Transmitter

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

FIELD DEVICES PRESSURE

DRS390 High stability, flange mounting

Kotron Model 82 CE RF Level Transmitter

Echotel Model 910 Ultrasonic Level Switch

I/A Series Electronic Pressure Transmitters with 4 to 20 ma Analog Output for Absolute and Gauge Pressure Measurement

Compact Orifice Flow Meter

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE)

ST 3000 Smart Transmitter Series 900 Absolute Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /07

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

IAP10/IGP10 TRANSMITTER STRUCTURE CODES 52, 53, 60-63, D5, D6, S5, S6, SH, AND SJ

General Specifications

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Electro-Magnetic Flowmeters COPA-XE

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

DREXELBROOK DREXELBROOK. Impulse. Series IMPULSE. IMPULSE Series. Guided Wave Radar (TDR) for Total Level and Volumetric Measurements DATA SHEET

Level Measurement Continuous level measurement Radar transmitters

SmartLine Wireless Pressure Gauge Transmitter Specification

D E S C R I P T I O N F E A T U R E S A P P L I C A T I O N S. The Enhanced Jupiter Magnetostrictive level transmitter

Echotel Trident 91S/92S Ultrasonic Level Switches

ST 3000 Smart Transmitter Release 300 and Smart Field Communicator Model STS103. User s Manual. 34-ST February Honeywell Process Solutions

FCX. Series AII & AIIe Electronic Transmitters. Barton

FUNCTIONAL SPECIFICATIONS

OriMaster FPD500 Compact orifice flowmeter. Orifice-based flow metering made simple

Series Smart Pressure Transmitter

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products

IP26 Series Current to Pneumatic Converter

Submersible pressure sensor For oils and fuels Model LF-1

FIELD DEVICES PRESSURE

Fisher 4200 Series Electronic Position Transmitters

Fisher 646 Electro Pneumatic Transducer

Smart Displacer Level (Interface) Transmitter DLT100 Series

Fisher 646 Electro-Pneumatic Transducers

Transcription:

ST 3000 Smart Transmitter Series 100 Remote Diaphragm Seals Models STR12D 0-10 to 0-400 inh 2 O 0-25 to 0-1000 mbar STR13D 0-5 to 0-100 psid 0-0.35 to 0-7 bar STR14G 0-5 to 0-500 psig 0-0.35 to 0-35 bar STR17G 0-100 to 0-3000 psig 0-7 to 0-210 bar STR14A 0-5 to 0-500 psia 0-0.35 to 0-35 bar 34-ST-03-64 11/98 Specification and Model Selection Guide Function Honeywell s microprocessor-based ST 3000 Series 100 Transmitter with Remote Diaphragm Seals (Figure 1) measures process pressures and levels, and transmits an output signal proportional to the measured variable. The output signal is transmitted in either an analog 4 to 20 milliampere format or in a digital DE protocol format for direct digital communications with our TDC 3000 X control system. A protocol option will let you use these transmitters in FOUNDATION Fieldbus¹ networks. You easily select the analog or digital transmission format through the Smart Field Communicator (SFC ) which is the common handheld operator interface for our Smartline Transmitters. All configuration, operation, and communications functions are under the control of the ST 3000 Smart Transmitter s micro-processor and are accessible through the SFC. Remote diaphragms seals are used: when the process medium is a slurry or has suspended solids that may clog the instrument line, when the process medium might freeze or solidify due to ambient or process temperature changes, with corrosive process mediums with high temperature processes, for Sanitary applications. TAG No. SFC WORKING... Can be ordered separately see specification 34-ST-03-55 ID CONF LRV 0% MENU ITEM DAMP UNITS URV 100% SET OUT- PUT NEXT STAT PREV 7 8 9 4 5 SPAN 6 NUM/ ALPHA 3 1 2 0. SHI FT Remote Diaphragm Seals Transmitter Model STR12D Smart Field Communicator COR- RECT +/- CLR (NO) ENTER (YES) 24260 Figure 1 ST 3000 Series 100 transmitter with remote diaphragm seals. ¹ FOUNDATION Fieldbus is a trademark of the Fieldbus Foundation. Industrial Automation and Control, 16404 N. Black Canyon Highway, Phoenix, AZ 85023 Printed in U.S.A. Copyright 1998 Honeywell Inc.

Page 2 Features Description Choice of linear or square root output conformity is a simple configuration selection. Direct digital integration with TDC 3000 X system provides local measurement accuracy to the system level without adding typical A/D and D/A converter inaccuracies. Unique piezoresistive sensor automatically compensates input for temperature and static pressure. (Static pressure measurement is not made on Inline Gauge and Absolute units.) Added smart features include configuring lower and upper range values, simulating accurate analog output, and selecting preprogrammed engineering units for display. Smart transmitter personality with local or remote interfacing means significant manpower efficiency improvements in commissioning, start-up, and ongoing maintenance functions. The ST 3000 transmitter can replace any 4 to 20 milliampere output transmitter in use today, and operates over a standard two-wire system. The measuring means is a piezoresistive sensor which actually contains three sensors in one: a differential pressure sensor, a temperature sensor, and a static pressure sensor. (Static pressure measurement is not made on In-line Gauge and Absolute units.) Microprocessorbased electronics provide major improvements over conventional transmitters: higher spanturndown ratio, improved temperature and pressure compensation, and improved accuracy. Like other Smartline Transmitters, the ST 3000 features two-way communication between the operator and the transmitter through our SFC. You can connect the SFC anywhere that you can access the transmitter signal lines, and it provides the capabilities of transmitter adjustments and diagnostics from remote locations, such as the control room. The transmitter s body and electronics housing resist shock, vibration, corrosion, and moisture. The electronics housing contains a compartment for the single-board electronics, which is isolated from an integral junction box. The single-board electronics is replaceable and interchangeable with any other ST 3000 Series 100 model transmitter. Specifications Operating Conditions All Models Para Reference Condition Rated Condition Operative Limits Transportation and Storage C F C F C F C F Ambient Temperature* 25 ±1 77 ±2 55 to 90 67 to 194 Humidity % RH 10 to 55 0 to 100 0 to 100 0 to 100 Overpressure Flange Rating ANSI Class 150 ANSI Class 300 Vacuum Region - Minimum Pressure mmhg absolute Supply Voltage, Current, and Load Resistance See Model Selection Guide. Atmospheric (See Figure 4 for Vacuum limitations.) Voltage Range: 10.8 to 42.4 Vdc at terminals Current Range: 3.0 to 21.8 ma Load Resistance: 0 to 1440 ohms (as shown in Figure 5) *Ambient Temperature Limit is a function of Process Interface Temperature. (See Figure 2.)

Page 3 Performance Under Rated Conditions* - Model STR12D (0-10 to 0-400 inh 2 O) Para Upper Range Limit** Minimum Span inh2o mbar inh2o mbar Description 400 (39.2 F/4 C is standard reference temperature for inh2o range.) 1000 10 Note: Recommended minimum span in square root mode is 20 inh2o (50 mbar). 25 Turndown Ratio 40 to 1 Zero Elevation and Suppression Accuracy (Reference Includes combined effects of linearity, hysteresis, and repeatability) Accuracy includes residual error after averaging successive readings. Combined Zero and Span Temperature Effect per 28 C (50 F) No limit except minimum span within ±100% URL. In Analog Mode: ±0.2% of calibrated span or upper range value (URV), whichever is greater, terminal based. For URV below reference point (50 inh2o), accuracy equals: 50 inh2o ±0.1 + 0.1 span inh2o or ±0.1 + 0.1 125 mbar span mbar In Digital Mode: ±0.175% of calibrated span or upper range value (URV), whichever is greater, terminal based. For URV below reference point (50 inh2o), accuracy equals: 50 inh2o ±0.075 + 0.10 span inh2o or ±0.075 + 0.10 125 mbar span mbar In Analog Mode: ±1.2% of span. For URV below reference point (100 inh2o), effect equals: ±0.2 + 1.0 100 inh2o span inh2o or ±0.2 + 1.0 250 mbar span mbar In Digital Mode: ±1.175% of span. For URV below reference point (100 inh2o), effect equals: 100 inh2o ±0.175 + 1.0 span inh2o or ±0.175 + 1.0 250 mbar span mbar *Performance specifications are based on reference conditions of 25 C (77 F), zero (0) static pressure, 10 to 55% RH, and 316L Stainless Steel barrier diaphragm. **Transmitter URL limit or maximum seal pressure rating, whichever is lower.

Page 4 Performance Under Rated Conditions* - Model STR13D (0-5 to 0-100 psid) Para Description Upper Range Limit** Minimum Span psid bar psid bar 100 7 5 0.35 Turndown Ratio 20 to 1 Zero Elevation and Suppression Accuracy (Reference Includes combined effects of linearity, hysteresis, and repeatability) Stated accuracy does not apply for models with 2.9 inch dia remote seal diaphragms. Accuracy includes residual error after averaging successive readings. No limit except minimum span within 18% and +100% of URL. Specifications valid from 5% to 100% of URL. In Analog Mode: ±0.1% of calibrated span or upper range value (URV), whichever is greater, terminal based. For URV below reference point (30 psi), accuracy equals: ±0.05 + 0.05 30 psi span psi or ±0.05 + 0.05 2 bar In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever is greater, terminal based. For URV below reference point (30 psi), accuracy equals: ±0.025 + 0.05 30 psi span psi or ±0.025 + 0.05 2 bar Combined Zero and Span Temperature Effect per 28 C (50 F) In Analog Mode: ±0.33% of span. For URV below reference point (30 psi), effect equals: ±0.05 + 0.28 30 psi span psi or ±0.05 + 0.28 2 bar In Digital Mode: ±0.305% of span. For URV below reference point (30 psi), effect equals: ±0.025 + 0.28 30 psi span psi or ±0.025 + 0.28 2 bar *Performance specifications are based on reference conditions of 25 C (77 F), zero (0) static pressure, 10 to 55% RH, and 316L Stainless Steel barrier diaphragm. **Transmitter URL limit or maximum seal pressure rating, whichever is lower.

Page 5 Performance Under Rated Conditions* - Model STR14G (0-5 to 0-500 psig) Para Description Upper Range Limit** Minimum Span psig bar psig bar 500 35 5 0.35 Turndown Ratio 100 to 1 Zero Elevation and Suppression Accuracy (Reference Includes combined effects of linearity, hysteresis, and repeatability) Accuracy includes residual error after averaging successive readings. Combined Zero and Span Temperature Effect per 28 C (50 F) No limit except minimum span from absolute zero to 100% of URL. Specifications valid over this range. In Analog Mode: ±0.1% of calibrated span or upper range value (URV), whichever is greater. For URV below reference point (20 psi), accuracy equals: ±0.05 + 0.05 20 psi span psi or ±0.05 + 0.05 1.4 bar In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever is greater. For URV below reference point (20 psi), accuracy equals: ±0.025 + 0.05 20 psi span psi In Analog Mode: ±1.88% of span. or ±0.025 + 0.05 1.4 bar For URV below reference point (75 psi), effect equals: ±0.2 + 1.68 75 psi span psi or ±0.2 + 1.68 5.25 bar In Digital Mode: ±1.855% of span For URV below reference point (75 psi), effect equals: ±0.175 + 1.68 75 psi span psi or ±0.175 + 1.68 5.25 bar *Performance specifications are based on reference conditions of 25 C (77 F), zero (0) static pressure, 10 to 55% RH, and 316L Stainless Steel barrier diaphragm. **Transmitter URL limit or maximum seal pressure rating, whichever is lower.

Page 6 Performance Under Rated Conditions* - Model STR17G (0-100 to 0-3000 psig) Para Description Upper Range Limit** Minimum Span psig bar psig bar 3000 210 100 7 Turndown Ratio 30 to 1 Zero Elevation and Suppression Accuracy (Reference Includes combined effects of linearity, hysteresis, and repeatability) Accuracy includes residual error after averaging successive readings. Combined Zero and Span Temperature Effect per 28 C (50 F) No limit except minimum span from absolute zero to 100% of URL. Specifications valid over this range. In Analog Mode: ±0.15% of calibrated span or upper range value (URV), whichever is greater. For URV below reference point (300 psi), accuracy equals: ±0.10 + 0.05 300 psi span psi or ±0.10 + 0.05 21 bar In Digital Mode: ±0.125% of calibrated span or upper range value (URV), whichever is greater. For URV below reference point (300 psi), accuracy equals: ±0.075 + 0.05 300 psi span psi or ±0.075 + 0.05 21 bar In Analog Mode: ±0.70% of span. For URV below reference point (500 psi), effect equals: ±0.20 + 0.50 500 psi span psi or ±0.2 + 0.50 34.5 bar In Digital Mode: ±0.675% of span. For URV below reference point (500 psi), effect equals: ±0.175 + 0.50 500 psi span psi or ±0.175 + 0.50 34.5 bar *Performance specifications are based on reference conditions of 25 C (77 F), zero (0) static pressure, 10 to 55% RH, and 316L Stainless Steel barrier diaphragm. **Transmitter URL limit or maximum seal pressure rating, whichever is lower.

Page 7 Performance Under Rated Conditions* - Model STR14A (0-5 to 0-500 psia) Para Description Upper Range Limit** psia bar absolute 500 35 Minimum Span psia bar absolute 5 0.35 Turndown Ratio 100 to 1 Zero Elevation and Suppression Accuracy (Reference Includes combined effects of linearity, hysteresis, and repeatability) Accuracy includes residual error after averaging successive readings. Combined Zero and Span Temperature Effect per 28 C (50 F) No limit except minimum span from 0 to 100% URL. In Analog Mode: ±0.1% of calibrated span or upper range value (URV), whichever is greater. For URV below reference point (20 psi), accuracy equals: ±0.05 + 0.05 20 psi span psi or ±0.05 + 0.05 1.4 bar In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever is greater. For URV below reference point (20 psi), accuracy equals: ±0.025 + 0.05 20 psi span psi or ±0.025 + 0.05 1.4 bar In Analog Mode: ±1.88% of span. For URV below reference point (50 psi), effect equals: ±0.2 + 1.68 50 psi span psi or ±0.2 + 1.68 3.5 bar In Digital Mode: ±1.855% of span For URV below reference point (50 psi), effect equals: ±0.175 + 1.68 50 psi span psi or ±0.175 + 1.68 3.5 bar *Performance specifications are based on reference conditions of 25 C (77 F), zero (0) static pressure, 10 to 55% RH, and 316L Stainless Steel barrier diaphragm. **Transmitter URL limit or maximum seal pressure rating, whichever is lower.

Page 8 Performance Under Rated Conditions General for all Models Para Description Output (two-wire) Supply Voltage Effect Damping Time Constant RFI Protection (Standard) CE Conformity (Europe) Analog 4 to 20 ma or digital communications DE mode. ±0.005% span per volt. Adjustable from 0 to 32 seconds digital damping. Negligible (20 to 1000 MHz at 30 volts per ). 89/336/EEC, Electromagnetic Compatibility (EMC) Directive. Physical and Approval Bodies Para Description Process Interface Seal Barrier Diaphgram Seal Gasket Materials Mounting Bracket See Model Selection Guide for Material Options for desired seal type. 316L Stainless Steel, Monel, Hastelloy C, Tantalum Klinger C-4401 (non-asbestos) Grafoil Carbon Steel (Zinc-Chromate plated) or Stainless Steel. Fill Fluid (Meter Body) Silicone (DC 200) S.G. @ 25 C = 0.94 CTFE (Chlorotrifluoroethylene) S.G. @ 25 C = 1.89 Fill Fluid (Secondary) Silicone (DC 200) S.G. @ 25 C = 0.94 CTFE (Chlorotrifluoroethylene) S.G. @ 25 C = 1.89 Silicone (DC 704) S.G. @ 25 C = 1.07 NEOBEE M-20 S.G. @ 25 C = 0.90 Syltherm 800 S.G. @ 25 C = 0.93 Electronic Housing Capillary Tubing Epoxy-Polyester hybrid paint. Low copper-aluminum alloy. Meets NEMA 4X (watertight) and NEMA 7 (explosion proof). Stainless steel optional. Armored Stainless Steel or PVC Coated Armored Stainless Steel. Length: 5, 10, 15, 20, 25, and 35 feet (1.5, 3, 4.6, 6.1, 7.5, and 10.7 s). 2 or 6 inches (51 to 152 millis) long close-coupled nipple is also available. Refer to Figure 3 for guide to maximum capillary length vs. diaphragm dia. Wiring Accepts up to 16 AWG (1.5 mm dia). Mounting See Figure 6. Dimensions Transmitter: See Figures 9 and 10. Seal: See Model Selection Guide. Net Weight Approval Bodies Transmitter: 15.4 pounds (7 Kg). Total weight is dependent on seal type and capillary length. Approved as explosion proof and intrinsically safe for use in Class I, Division 1, Groups A, B, C, D locations, and nonincendive for Class I, Division 2, Groups A, B, C, D locations. Approved EEx ia IIC T5 and EEx d IIC T6 per CENELEC standards; and Ex N II T5 per BS 6941.

Page 9 Maximum Ambient Temperature ( F) 200 180 160 140 120 100 80 60 40 20 0 185 185 165 165 140 140 200 350 450 ST3000 DP/I LGP/I & AP/I Process Interface Temperature ( F) 20385 Figure 2 Ambient temperature and process interface chart. Maximum Length (ft.) S100e Remote Seal Maximum Capillary Length 35 30 25 20 15 10 5 0 1.9 2.4 2.9 3.5 4.1 Diaphragm Size (in.) This chart is intended to serve as a guide in selecting the appropriate diaphragm size for the required capillary length. ST3000 DP/I with 2 seals LGP/I & AP/I & DP/I with 1 seal 20337 Figure 3 Maximum capillary length and diaphragm size chart.

Page 10 Maximum Pressure Limited by Flange Rating of Seal 10000 9000 8000 7000 6000 5000 4000 3000 2000 Silicone DC704 30 to 450 F Silicone DC200-40 to 350 F 193 psig 1000 900 800 700 600 500 400 300 200 100 90 80 70 60 50 40 30 20 Pressure (mmhga) 10-100 Maximum Pressure Limited by Flange Rating of Seal CTFE 5 to 300 F Special High Vacuum Construction required. Consult STC. 1Atm 0 psig -14-40 5 25 30 175 350 450 psig 0 100 200 300 400 500 Process Temperature (Degrees F) -9 psig 10000 9000 8000 7000 6000 5000 4000 3000 2000 NEOBEE M-20 30 to 400 F Syltherm 800-40 to 600 F 193 psig 90 psig 1000 900 800 700 600 500 400 300 200 100 90 80 70 60 50 40 30 20 Pressure (mmhga) 10-100 -40 5 25 30 0 100 1Atm 0 psig -9 psig -14 175 450 550 psig 200 400 500 600 Process Temperature (Degrees F) 20335 Figure 4 ST 3000 Remote Seals operable limits for pressure vs. temperature.

Page 11 1440 1200 Operating Area Loop Resistance (ohms) 800 650 450 250 0 10.8 16.28 20.63 25 28.3 37.0 42.4 NOTE: A minimum of 250 ohms of loop resistance is necessary to support communication. Loop resistance equals barrier resistance plus wire resistance plus receiver resistance. Also, 45 volt operation is permitted if not an intrinsically safe installation. Supply Voltage 20338 Figure 5 Supply voltage/loop resistance chart. LP Side Maximum level H2 Fixed ref. leg Variable Head H1. Minimum level HP Side 24249 NOTE: Lower flange seal should not be mounted over 22 feet below or above the transmitter for silicone fill fluid (11 feet for CTFE fill fluid) with tank at one atmosphere. The combination of tank vacuum and high pressure capillary head effect should not exceed 9 psi vacuum (300 mmhg absolute). Consult Honeywell for installation of STR13D. Figure 6 The ST 3000 transmitter with remote diaphragm seals shown mounted on a tank.

Page 12 Application Data* Liquid Level: Closed Tank Determine the minimum and maximum pressure differentials to be measured (Figure 7). Max Level b LP P Min = (SG p x a) (SG f x d) = LRV when HP at bottom of tank = URV when LP at bottom of tank P Max = (SG p x b) (SG f x d) Min Level Transmitter above datum a HP = URV when HP at bottom of tank = LRV when LP at bottom of tank Max Level LP Where: b Minimum level at 4 ma Maximum level at 20 ma Min Level a HP a = distance between bottom tap and minimum level Transmitter at datum b = distance between bottom tap and maximum level d = distance between taps Max Level LP SG f = Specific Gravity of capillary fill fluid (see page 8 for values) b SG p = Specific Gravity of process fluid Min Level a HP Transmitter below datum 24253 Figure 7 Closed tank liquid level measurement distances. * Contact STC-Phoenix concerning applications for model STR13D.

Page 13 Density or Interface* Calculate the minimum and maximum pressure differentials to be measured. P min = (SG min - SG f ) x (d); minimum density, 4mA output LP P max = (SG max - SG f ) x (d); maximum density, 20mA output Where: HP d = SG max = SG min = SGf = distance between the taps maximum Specific Gravity minimum Specific Gravity Specific Gravity of capillary fill fluid (see page 8 for values) 24257 Figure 8 Density, direct acting instrument configuration. * Contact STC-Phoenix concerning applications for model STR13D.

Page 14 With Smart Removal 45.7 Clearance 1.8 for All Caps 82.9 3.26 53.1 2.09 Without 94.9 3.74 65.1 2.56 Without With Analog 23.5.925 Reference Dimensions: millis inches 55.3 2.18 135 5.32 3.6 0.14 Plug Optional s Optional external ground STR12D, STR13D DP/I Remote Seal with Horizontal Pipe Mount 85 3.35 Rotational lock LP seal omitted for clarity With Smart Removal 45.7 Clearance 1.8 for All Caps 82.9 3.26 53.1 2.09 Without 94.9 3.74 65.1 2.56 Without With Analog 23.5.925 Optional external ground STR14A AP/I Remote Seal with Horizontal Pipe Mount 55.3 2.18 42.5 1.67 135 5.32 50 1.97 3.6 0.14 Plug Optional s Rotational lock 71.1 2.80 SQ. Seal omitted for clarity With Smart Removal 45.7 Clearance 1.8 for All Caps 82.9 3.26 53.1 2.09 Without 94.9 3.74 65.1 2.56 Without With Analog 23.5.925 Optional external ground STR14G, STR17G LGP/I Remote Seal with Horizontal Pipe Mount 55.3 2.18 135 5.32 3.6 0.14 Plug Optional s Rotational lock Seal omitted for clarity 24261 Figure 9 Approximate horizontal mounting dimensions for Remote Seal Transmitter.

Page 15 With Smart Removal 45.7 Clearance 1.8 for All Caps 82.9 3.26 53.1 2.09 Without 94.9 3.74 65.1 2.56 Without With Analog 23.5.925 Optional external ground Reference Dimensions: millis inches 55.3 2.18 135 5.32 3.6 0.14 Plug Optional s Rotational lock LP seal omitted for clarity STR12D, STR13D DP/I Remote Seal with Vertical Pipe Mount 85 3.35 SQ With Smart Removal 45.7 Clearance 1.8 for All Caps 82.9 3.26 53.1 2.09 Without 94.9 3.74 65.1 2.56 Without With Analog 23.5.925 Optional external ground STR14A AP/I Remote Seal with Vertical Pipe Mount 42.5 1.67 55.3 2.18 50 1.97 135 5.32 3.6 0.14 Plug Optional s Rotational lock 71.1 2.80 SQ. Seal omitted for clarity With Smart Removal 45.7 Clearance 1.8 for All Caps 82.9 3.26 53.1 2.09 Without 94.9 3.74 65.1 2.56 Without With Analog 23.5.925 STR14G, STR17G LGP/I Remote Seal with Vertical Pipe Mount (Flat Bracket) 55.3 2.18 135 5.32 3.6 0.14 Plug Optional s Optional external ground Rotational lock Seal omitted for clarity 24262 Figure 10 Approximate vertical mounting dimensions for Remote Seal Transmitter.

Page 16 Options Ordering Information Mounting Bracket The angle mounting bracket is available in either zinc-plated carbon steel or stainless steel and is suitable for horizontal or vertical mounting on a two inch (50 milli) pipe, as well as wall mounting. An optional flat mounting bracket is also available in carbon steel for two inch (50 milli) pipe mounting. Indicating Meter Two integral options are available. An analog (option ME) is available with a 0 to 100% linear scale. The Smart Meter (option SM) provides an LCD display for both analog and digital output and can be configured to display pressure in pre-selected engineering units. Lightning Protection A terminal block with circuitry that protects the transmitter from transient surges induced by nearby lightning strikes is available. Tagging (Option TG) Up to 30 characters can be added on the stainless steel nameplate mounted on the transmitter s electronics housing at no extra cost. Note that a separate nameplate on the body contains the serial number and body-related data. A stainless steel wired on tag with additional data of up to 4 lines of 28 characters is also available. The number of characters for tagging includes spaces. Transmitter Configuration (Option TC) The factory can configure the transmitter linear/square root extraction, damping time, LRV, URV and mode (analog/digital) and enter an ID tag of up to eight characters and scratchpad information as specified. Custom Calibration and ID in Memory (Option CC) The factory can calibrate any range within the scope of the transmitter s range and enter an ID tag of up to eight characters in the transmitter s memory. FOUNDATION Fieldbus (Option FF) Equips transmitter with FF protocol for use in 31.25 kbit/s FF networks. See document 34-ST-03-72 for additional information on ST 3000 Fieldbus transmitters. Contact your nearest Honeywell sales office, or In the U.S.: Honeywell Industrial Automation & Control 16404 N. Black Canyon Highway Phoenix, AZ 85023 1-800-288-7491 In Canada: The Honeywell Centre 155 Gordon Baker Rd. North York, Ontario M2H 3N7 1-800-461-0013 In Latin America: Honeywell Inc. 480 Sawgrass Corporate Parkway, Suite 200 Sunrise, FL 33325 (954) 845-2600 In Europe: Honeywell PACE 1, Avenue du Bourget B-1140 Brussels, Belgium [32-2] 728-2111 In Asia: Honeywell Asia Pacific Inc. Room 3213-25 Sun Hung Kai Centre No. 30 Harbour Road Wanchai, Hong Kong 2829-8298 In the Pacific: Honeywell Limited 5 Thomas Holt Drive North Ryde NSW 2113 Australia (61 2) 9353 7000 Or, visit Honeywell on the World Wide Web at: http://www.honeywell.com Specifications are subject to change without notice.

Page 17 Model Selection Guide 34-ST-16-32,33 Instructions Select the desired Key Number. The arrow to the right marks the selection available. Make one selection from each table, I and II, using the column below the proper arrow. Select as many Table III options as desired (if no options are desired, specify 00). A dot denotes unrestricted availability. A letter denotes restricted availability. Restrictions follow Table IV. Key Number I II III (Optional) IV - _ - -, + XXXX KEY NUMBER Selection Availability Description 0-10" to 0-400" H2O/0-25 to 0-1000 mbar STR12D (Note) Body Rating*: 2500 psi (172 bar) Compound Characterized 0-5 to 0-100 psi/0-0.34 to 0-7 bar STR13D Body Rating*: 2500 psi (172 bar) 0-5 to 0-500 psi/0-0.34 bar to 0-35 bar STR14G Body Rating*: 500 psi (35 bar) 0-100 to 0-3000 psi/0-7 bar to 210 bar STR17G Body Rating*: 2500 psi (172 bar) 0-5 to 0-500 psia/0-0.34 to 0-35 bar STR14A Body Rating*: 500 psi (35 bar) Note: With Model STR12D, Table III, Option CM must be specified. * Remote seal system pressure rating is body rating or seal rating, whichever is less. TABLE I - METER BODY 1 Remote Seal (High Side)+G40 1 Number of Seals 2 Remote Seals 2 1 Remote Seal (Low Side) 3 Fill Fluid Silicone (DC 200) _ 1 _ (Meter Body) CTFE _ 2 _ q q q q q Construction Non-Wetted Adapter Head Material 316 St. St. A Standard Dual Head Carbon St. (zinc-plated) B 316 St. St. for Close-Couple D y y Standard In-line 316 St. St. Bonnet A Design 316 St. St. Bonnet for Close-Couple D y y Standard Single 316 St. St. Adapter Head A Head Design 316 St. St. Head for Close-Couple D y

Page 18 Model Selection Guide, continued STR14A STR1_G STR1_D TABLE II - SEALS Selection 2 3 4 7 Format for Seal Selection: Specify 12 characters Common Required Seal Note: The first 3 characters are common to all seals. When selecting required seal, you must specify only the 9 selections within the required seal. Silicone (DC 200) 1 _ Secondary CTFE 2 _ Fill Silicone (DC 704) 3 _ p p p p p Neobee(M20) ** 4 _ Syltherm 800 *** 5 _ p p p p p 5 feet 1.5 m _ A 10 feet 3.0 m _ B 15 feet 4.5 m SS Armor _ C 20 feet 6.1 m _ D 25 feet 7.5 m _ E Connection Capillary 35 feet 10.7 m _ F of Remote Length 5 feet 1.5 m _ G Seal to 10 feet 3.0 m PVC Coated _ H Meter Body 15 feet 4.5 m SS Armor _ J 20 feet 6.1 m _ K 25 feet 7.5 m _ L 35 feet 10.7 m _ M 2 inch long SS nipple close-coupled _ 2 z z z z z 6 inch long SS nipple close-coupled _ 6 z z z z z No Selection 0 _ Diaphragm Flange Flange Pressure Dia Size Rating * ANSI Class 150 _ AFA Flush 3.5" 3" ANSI Class 300 _ AFC Flanged DIN DN80-PN40 _ AFM Seal Diaphragm Upper Insert 316L SS 316 St. St. AA Wetted Material Hastelloy C 316 St. St. AB Hastelloy C Hastelloy C AC Monel Monel AE Non-Wetted CS with Polyester 1 _ Material (upper) Powder Coating 316 St. St. 2 _ Bolts No Selection _ 0 Sytles No Selection 0 _ Gasket No Selection _ 0 * Standard facing 125-250 AARH RF (raised face) serrated surface finish. Table II continued next page ** Limited vacuum availability. *** Minimum static pressure requirement. No vacuum allowed. See Specifications Figure 4.

Page 19 STR14A STR1_G STR1_D TABLE II - SEALS (continued) Selection 2 3 4 7 Diaphragm Flange Flange Const. - See Construction - See Spec. Dia Size Pressure Spec. Figure 34-ST-03-64 figure Rating * 34-ST-03-64 1" ANSI 150 11 _ BCA t ANSI 300 11 _ BCC t 2.4" 1-1/2" ANSI 150 11 _ BGA t ANSI 300 11 _ BGC t 2" ANSI 150 11 _ BDA t ANSI 300 11 _ BDC t 3" ANSI 150 11 _ BFA t ANSI 300 11 _ BFC t 1/2" ANSI 150 12 _ CAA t t 1" ANSI 150 12 _ CCA t t ANSI 300 12 _ CCC t t 2.9" 1-1/2" ANSI 150 11 _ CGA t t ANSI 300 11 _ CGC t t 2" ANSI 150 11 _ CDA t t ANSI 300 11 _ CDC t t 1/2" ANSI 150 12 _ DAA 1" ANSI 150 12 _ DCA ANSI 300 12 _ DCC Flush 1-1/2" ANSI 150 12 _ DGA Flanged 4.1" ANSI 300 12 _ DGC Seal with 2" ANSI 150 12 _ DDA Lower ANSI 300 11 _ DDC 3" ANSI 150 11 _ DFA ANSI 300 11 _ DFC Diaphragm Lower 316L SS 316 St. St. BA Wetted Material Hastelloy C 316 St. St. BB Hastelloy C Hastelloy C BC Monel Monel BE Tantalum 316 St. St. BF Tantalum Hastelloy C BG Non-Wetted Upper Upper Insert Material (upper, 316 St. St. 316 St. St. 4 _ upper insert) CS 316 St/ St. 5 _ Bolts No Selection _ 0 Without 1/4" NPT Flushing 0 _ Styles Connection With 1/4" NPT Flushing 7 _ Connection Gasket Klinger C-4401 _ K c c c c c (non-asbestos) Grafoil _ G d d d d d Table II continued next page * Standard facing 125-250 AARH RF (raised face) serrated finish.

Page 20 Model Selection Guide, continued STR14A STR1_G STR1_D TABLE II - SEALS (continued) Selection 2 3 4 7 Diaphragm Flange Flange Pressure Dia Size Rating * 2.9" 3" ANSI Class 150 _ EFA t t (2.85") (2.85" OD ANSI Class 300 _ EFC t t extension) DIN DN80-PN40 _ EFM t t Flange 4" ANSI Class 150 _ FGA Seal with 3.5" (3.70" OD ANSI Class 300 _ FGC Extended extension) DIN DN100-PN40 _ FGP Diaphragm Diaphragm Lower 316L SS 316 St. St. EA Wetted Material Hastelloy C 316 St. St. EB Hastelloy C Hastelloy C EC Non-Wetted CS with Polyester Powder 7 _ Material (flange) Coating Bolts No Selection _ 0 Extension 2" 2 _ Length 4" 4 _ 6" 6 _ Gasket No Selection _ 0 Diaphragm Flange Flange Pressure Rating ** Dia Size Dependent on customer flange 3.5" 3" ANSI Class 150/300/600 _ GFA Diaphragm Body Pancake 316L SS 316 St. St. GA Seal Wetted Material Hastelloy C 316 St. St. GB Hastelloy C Hastelloy C GC Monel Monel GE Non-Wetted No Selection 0 _ Material Bolts No Selection _ 0 Styles No Selection 0 _ Gasket No Selection _ 0 Table II continued next page * Standard facing 125-250 AARH RF (raised face) serrated finish. ** Caution: Maximum working pressure of STR14G and STR14A transmitter is 500 psig and STR17G is 3000 psig. Damage to sensosr may result if pressure limit is exceeded.

Page 21 STR14A STR1_G STR1_D TABLE II - SEALS (continued) Selection 2 3 4 7 Diaphragm Flange Flange Pressure Dia Size Rating ** Taylor 3.5" Wedge 750 psi _ HM0 v v Chemical 5" O.D. Tee "Taylor" Diaphragm Lower Wedge Wetted Material 316L SS 316 St. St. HA Hastelloy C 316 St. St. HB Non-Wetted No Selection 0 _ Material Bolts No Selection _ 0 Styles No Selection 0 _ Gasket No Selection _ 0 Diaphragm Threaded Process Pressure Dia Connection Size Rating (NPT Female) CS Bolts 304 SS Bolts 1/2" NPT _ JJG t 2.4" 3/4" NPT _ JKG t 1" NPT 2500 1250 _ JLG t 1/2" NPT psi psi _ KJG t t 2.9" 3/4" NPT _ KKG t t 1" NPT _ KLG t t 1/2" NPT _ LJG 4.1" 3/4" NPT 1500 750 _ LKG Seal with 1" NPT psi psi _ LLG Threaded Diaphragm Lower Process 316L SS CS JA Connection Wetted Material 316L SS 316 St. St. JB Hastelloy C 316 St. St. JC Hastelloy C Hastelloy C JD Monel Monel JE Tantalum 316 St. St. JF Tantalum Hastelloy C. JG Non-Wetted CS with Polyester Material Powder Coating A _ (upper) Stainless Steel C _ w w w w w Bolts C.S. _ C 304 St. St. _ D Styles W/O Flushing Connection A _ With Flushing Connection F _ Gasket Klinger C-4401 _ K c c c c c (non-asbestos) Grafoil _ G d d d d d Table II continued next page ** Caution: Maximum working pressure of STR14G and STR14A transmitter is 500 psig and STR17G is 3000 psig. Damage to sensor may result if pressure limit is exceeded.

Page 22 Model Selection Guide, continued STR14A STR1_G STR1_D TABLE II - SEALS (continued) Selection 2 3 4 7 Diaphragm Flange Pressure Rating Dia Size 1.9" 2" _ MD0 2.4" 2-1/2" Customer clamp rating or _ NE0 2.9" 3" 600 psi, whichever is less _ PF0 t t 4.1" 4" _ QG0 Sanitary Diaphragm Body Seal Wetted Material 316L SS 316 St. St. N A Non-Wetted No Selection 0 _ Material Bolts No Selection _ 0 Styles Tri-Clover Tri-Clamp 8 _ Gasket No Selection _ 0 Diaphragm Size and Seal Pressure Rating * * Dia Bolt C.S. Bolts 304 St. St. Pattern Bolts for 3" 2.4" pipe- _ RPK t Conoflow 1250 psi 1250 psi or 4" or _ RQK t larger pipe- Conoflow Saddle Diaphragm Lower Housing Seal 316L SS C. S. RA 316L SS 316 St. St. RB Wetted Material Hastelloy C 316 St. St. RC 316 LSS N/A-Body Only SB Hastelloy C N/A-Body Only SC Non-Wetted Body Bolts * Material C. S. C. S. B _ 316 St. St. 304 St. St. C _ No Selection _ 0 Styles No Selection 0 _ Gasket No Selection _ 0 Note: All sanitary seals have dairy grade 3A approval. * Bolts are not included with "Body Only" selection. ** Caution: Maximum working pressure of STR14G and STR14A transmitter is 500 psig and STR17G is 3000 psig. Damage to sensor may result if pressure limit is exceeded.

Page 23 Model Selection Guide, continued STR14A STR1_G STR1_D TABLE III - OPTIONS 2 3 4 7 FOUNDATION Fieldbus Communications FF a a a a a Compound Characterized Meter Body CM s Mounting Bracket - Carbon Steel MB Mounting Bracket - ST. ST. SB b Flat Mounting Bracket FB 316 ST.ST. Electronics Housing with M20 Conduit Connections SH n n n n n 1/2" NPT to M20 316SS Conduit Adapter (BASEEFA EEx d IIC) A1 n n n n n b 1/2" NPT to 3/4" NPT 316 SS Conduit Adapter A2 u u u u u Lightning Protection LP Analog Meter (0-100 Even 0-10 Square Root) ME Smart Meter SM b A286SS (NACE) Bolts and 302/304SS (NACE) Nuts for Heads CR Stainless Steel Customer Wired-On Tag TG (4 lines, 28 characters per line, customer supplied information) Stainless Steel Customer Wired-On Tag (blank) TB Custom Calibration and I.D. in Memory CC Transmitter Configuration - non-fieldbus TC b Transmitter Configuration - Fieldbus FC a a a a a Write Protection WP Clean Transmitter for Oxygen or Chlorine Service with Certificate 0X h h h h h Over-Pressure Leak Test with F3392 Certificate TP Calibration Test Report and Certificate of Conformance (F3399) F1 b Certificate of Conformance (F3391) F3 Certificate of Origin (F0195) F5 NACE Certificate (F0198) F7 o o o Additional Warranty - 1 year W1 Additional Warranty - 2 years W2 b Additional Warranty - 3 years W3 Additional Warranty - 4 years W4 Local Zero & Span ZS m m m m m b Local Zero LZ x x x x x Table III continued next page

Page 24 STR14A STR1_G STR1_D TABLE III - OPTIONS (continued) Selection 2 3 4 7 Approval Body Approval Type Location or Classification Explosion Proof Class I, Div. 1, Groups A,B,C,D Factory Dust Ignition Proof Class II, III Div. 1, Groups E,F,G Mutual Non-Incendive Class I, Div. 2, Groups A,B,C,D F1D3 Intrinsically Safe Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G Explosion Proof Class I, Div. 1, Groups B,C,D CSA Dust Ignition Proof Class II, III, Div. 1, Groups E,F,G C1C3 Intrinsically Safe Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G Zone 2 Self-Declared Ex II 3 GD T (1) X (Europe) per 94/9/EC (1) T4 at Tamb. 93 o C, T5 at Tamb. H2D5 (ATEX4) 80 o C, T6 at Tamb. 65 o C b SA Intrinsically Safe Ex ia IIC T4 A0CA Non-Incendive Ex n IIC T6 (T4 with SM option) Flame Proof/ EEx d IIC T6 CENELEC LCIE Intrinsically Safe/ EEx ia IIC T5 E1D8 CENELEC Flame Proof/ EEx d IIC T6 E1D3 CENELEC No hazardous location approvals 9X Explosion Proof Class I, Div. 1, Groups A,B,C,D Factory Dust Ignition Proof Class II, III Div. 1, Groups E,F,G Mutual Non-Incendive Class I, Div. 2, Groups A,B,C,D 1C Intrinsically Safe Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G Explosion Proof Class I, Div. 1, Groups B,C,D CSA Dust Ignition Proof Class II, III, Div. 1, Groups E,F,G 2J Intrinsically Safe Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G Zone 2 Self-Declared Ex II 3 GD T (1) X (Europe) per 94/9/EC (1) T4 at Tamb. 93 o C, T5 at Tamb. 3N (ATEX4) 80 o C, T6 at Tamb. 65 o C SA Intrinsically Safe Ex ia IIC T4 4H a a a a a (Australia) Non-Incendive Ex n IIC T6 (T4 with SM option) Flame Proof Ex d IIC T6 Flame Proof/ EEx d IIC T6 3A CENELEC LCIE Intrinsically Safe/ EEx ia IIC T5 CENELEC Flame Proof/ EEx d IIC T6 3D CENELEC TABLE IV Factory Identification XXXX

Page 25 Model Selection Guide, continued RESTRICTIONS Restriction Available Only With Not Available With Letter Table Selection Table Selection a Pending b Select only one option from this group c II BF, BG, JF, JG, d II BF, BG, JF, JG, h I, II _ 2 _ - 2 _ m III 1C, 2J, 3N, 4G, 3A, 9X III ME, FF n III F1D3, C1C3,1C, 2J o III CR p II DC704 and Syltherm 800 fills and close-couple require SS seal upper. _ CAA 5 _, _ CCA 5 _, _ CCC 5 _, _ DAA 5 _, _ DCA 5 _, _ DCC 5 _, _ DGA 5 _, _ DGC 5 _, _ DDA 5 _, GE, A _ B _, _ BCA 5 _ q II 2, 4 r III 1C, 2J, 3N, 9X III SH, TC, ME See Figure 12 in Specification t II _ A, _ G, _ B, _ H, _ 2, _ 6, u III F1D3, C1C3, 1C, 2J w II _ JA x III FF, SM Restrictions continued next page

Page 26 Model Selection Guide, continued RESTRICTIONS - (continued) Restriction Available Only With Not Available With Letter Table Selection Table Selection y II _ 2, III MB, SB, FB _ 6 II DC704 and Syltherm 800 fills and close-couple require SS seal upper. _ CAA 5 _, _ CCA 5 _, _ CCC 5 _, _ DAA 5 _, _ DCA 5 _, _ DCC 5 _, _ DGA 5 _, _ DGC 5 _, _ DDA 5 _, GE, A _ B _, _ BCA 5 _ z I D NotSee 13:ST-27 for Published Specials with pricing. See 13:ST-29 and User s Manual for part numbers. See 13:ST-OE-9 for OMS Order Entry Information including TC, manuals, certificates, drawings and SPINS. See 13:ST-OD-1 for tagging, ID, Transmitter Configuration (TC) and calibration including factory default values. To request a quotation for a non-published "special", fax RFQ with Application Data Sheet (34-ST-18-01) to Marketing Applications. See Specification 34-ST-03-64 for seal dimensions.