Integrated signal generator 80 MHz to 6 GHz Integrated RF switch network Integrated freely configurable pulse modulators ( µs to 00 s) for radar pulse profiles Multiple options.5 TFT color display Safety interlock function Remote control via US, RS or LN The consist of an integrated RF signal generator, RF switch and interfaces. The unit is designed for various radiated EMC applications in the 80 MHz to 6 GHz frequency range. In addition to the generator, the system includes the M and PM modulators necessary for EMC testing. The second generation, called, includes freely configurable pulse modulators ( µs to 00 s) for radar pulse profiles as required e.g. by Ford FMC78 or VW TL8000. The RF signal can be switched to one of four outputs, where up to four power amplifiers can be connected directly. Two RF switches are supplied for combining four amplifier into two antenna paths. interlock outputs ensure the activation of the power amplifier for only the selected signal path. The.5 color display shows the generator parameters. LEDs indicate the state of further functions. The is provided by six digital, one analog and one optical input, as well as four digital outputs. Up to three power meters PMR 6006 can be connected directly to the. The provides remote control through its network, RS and US interfaces. power meter inputs for PMR 6006 Indicators for RF-switch network and interlock functions.5 color display ports and user port for TTL inputs, TTL outputs and supply voltages Standards: IEC / EN 6000-- IEC / EN 6000--0 IEC / EN 6000-- Ford FMC78 VW TL8000 nd others Remote control via RS, LN or US Inputs for trigger, external M and PM, outputs for 0 MHz and PM Interlock RF-switch network with x SPDT relays generator outputs
lock diagram 0 MHz PM int. M ext. PM ext. Trigger User-Port-IN 0- reference Digital & input nalog input User-Port-OUT 0- Signal generator interface Control unit RF outputs RF switch x Interlock x SPDT x PMR 6006 power meter Remote control: LN, RS, US Technical specifications Generator RF Frequency range: 80 MHz to 6 GHz Resolution: Hz Reference frequency: 0 MHz Max. adjustment deviation: ±50 Hz ging: 5 ppm Level range: -60 dm to +0 dm (-60 dm to +8 dm at f> GHz & ϑ>0 C) Resolution: 0. d ccuracy: < d, typ. <0.5 d (+5 to +5 C) Spectral distortion Harmonics (level 0 dm): <-0 dc, typ. <-5 dc Harmonics (level +0 dm): <-5 dc Non harmonics: <-5 dc mplitude modulation Modulation depth: 0 to 00% Resolution: 0.5% Modulation frequency range: Hz to 0 khz Frequency resolution: Hz
Generator (continued) Pulse modulation Modulation frequency range: 5 mhz to MHz Frequency resolution: 5 mhz Duty cycle: 0.05% to 00% Pulse on time: 500 ns External amplitude modulation (M) Level: Vpp to get 00% M, Hz to 0 khz nalog ports Front panel input analog: User port: PIN 5: PIN : PIN : PIN 5 and 0: NC socket, 0- V Ri=5 kω, 6 mv resolution D-Sub 5 pole + V / max. 00 m - V / max. 00 m +5 V / max. 00 m GND ack panel Generator outputs: x N sockets 50 Ω, 80 MHz to 6 GHz Interlock outputs: x NC sockets External M input: NC socket, impedance >0 kω External PM input: NC socket, TTL External PM output: NC socket, TTL, impedance >. kω 0 MHz reference output: NC socket, approx. 0 dm / 50 Ω RF Switch network: Relay type x SPDT, N sockets 50 Ω up to 00 MHz: 500 W up to 00 MHz: 800 W up to GHz: 500 W up to GHz: 00 W up to 6 GHz: 00 W Digital ports Front panel meter inputs to : for connecting up to Teseq PMR 6006 digital input and : NC socket, 0 to V via optical coupler Ri=.5 kω, switching threshold approx. to V
Digital ports (continued) optical input: POF (Polymeric optical fiber), HP versatile link HFR050 series 0 kd, (avoid scattered light on the front panel) User port: D-Sub 5 pole, TTL inputs, TTL outputs with amplifiers in a rack ack panel Trigger input: Remote ports RS: US device connector: Network: NC socket, TTL for external triggering, max. frequency 00 Hz, trigger delay <50 ms D-Sub 9 pole, up to 500 d connector type RJ5, Ethernet 0 / 00 SE-T supply Operating range: consumption: Fuse: 00 to 0 VC, 50 / 60 Hz, autoranging 90 V.5 (slow) for 0 V, (slow) for 0 V General data Operating temperature range: 0 C to 0 C Storage temperature range: -0 C to 60 C Relative humidity: 95% / 0 C (no moisture condensation) EMC: DIN / EN 66-:006 Shock: DIN / EN 60068--7 Vibration: DIN / EN 60068--6 Protection class: DIN / EN 600- / IEC 600- Mechanical specifications Size (W x H x D) : 5 cm (9 ) x 0.6 cm (HU) x. cm Weight: approx. 9.5 kg Cardboard box: 60 cm x 55 cm x 7 cm (additional space for option PMR 6006 available), weight of cardboard box approx.. kg (empty)
RDITED IMMUNITY TEST SYSTEM 80 MHz - 6 GHz Generator Interlock Switch RDITED IMMUNITY TEST SYSTEM 80 MHz - 6 GHz Generator Interlock Switch Digital 0.. V Digital 0.. V Digital nalog 0.. V 0.. V Digital nalog 0.. V 0.. V The included software allows configuration and application of the as an signal generator with many additional features like scalar quadripole measurements for measuring, for example, the insertion loss of the RF cable. For EMC testing, the can be used in combination with Teseq s WIN 6000 or Compliance comprehensive test system software. pplication with power amplifiers and antenna : analog, digital, optical to Generator out to x Switch / PM channel to amplifier and Switch (part of ) pplication with power amplifiers and antenna : analog, digital, optical to Generator out to x Switch / PM channel to Switch (part of ) amplifier to
RDITED IMMUNITY TEST SYSTEM 80 MHz - 6 GHz Generator Interlock Switch RDITED IMMUNITY TEST SYSTEM 80 MHz - 6 GHz Generator Interlock Switch Digital 0.. V Digital 0.. V Digital nalog 0.. V 0.. V Digital nalog 0.. V 0.. V pplication with power amplifiers and antennas : analog, digital, optical to Generator out to x Switch / PM channel to Switch (part of ) amplifier to pplication with power amplifiers and antennas : analog, digital, optical to Generator out to x Switch / PM channel to amplifier to Switch (part of )
RDITED IMMUNITY TEST SYSTEM 80 MHz - 6 GHz Generator Interlock Switch RDITED IMMUNITY TEST SYSTEM 80 MHz - 6 GHz Generator Interlock Switch Digital 0.. V Digital 0.. V Digital nalog 0.. V 0.. V Digital nalog 0.. V 0.. V pplication with up to GHz with power amplifiers, GTEM cell and connection to the emissions measuring system Generator out to x Switch / : analog, digital, optical to PM channel to meter PMR 6006 Switch (part of ) amplifier and to emission measuring system GTEM cell pplication with power amplifiers and GTEM cell Generator out to x Switch / : analog, digital, optical to PM channel to Switch (part of ) GTEM cell amplifier to
Model range and options Part number Description meter PM 6006, available as PMR 6006 or PMU 6006 RF-Switch network SW 60 WIN 6000, Test house software Teseq GmbH Landsberger Str. 55 6 erlin Germany T + 9 0 56 59 88 5 F + 9 0 56 59 88 deinfo.teseq@ametek.com www.teseq.com 5005 Immunity test system, 80 MHz to 6 GHz RF generator, RF switch network, system, country version EU, UK, US / JP 97-5005 -TC Traceable calibration (ISO705), order only with the device 98-5005 -DkkS DkkS calibration (ISO705), order only with the device 575 PMR 6006 meter PM 6006, MHz to 6 GHz, version R for direct connection to, cable LE - included (length m) 576 PMR 6006-0 meter PM 6006, MHz to 6 GHz, version R for direct connection to, cable LE -0 included (length 0 m) 576 PMU 6006 meter PM 6006, MHz to 6 GHz, version US for direct connection to PC, cable LE (length m) and storage case included 97-575 PM 6006-TC Traceable calibration (ISO705), order only with the device 98-575 PM 6006-DkkS DkkS calibration (ISO705), order only with the device 589 SW 60 Option for : RF-Switch network x SPDT 577 USO 0-RS-0 Converter US-to-serial / optical, 0 m POF, optical-to-rs 5700 IO 000 Input / output box, battery operated system with optical interface, incl. USO 0, 0 m fiber optical cable and storage case included 575 WIN 6000 Test house software with 5 months support January 06 Teseq Specifications subject to change without notice. Teseq is an ISO-registered company. Its products are designed and manufactured under the strict quality and environmental requirements of the ISO 900. This document has been carefully checked. However, Teseq does not assume any liability for errors or inaccuracies. For power amplifiers, directional couplers and antennas see www.teseq.com. 8-5005 E0 January 06