INLINE flowmeter for continuous flow measurement

Similar documents
INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement

Digital batch controller

Electromagnetic Flow Transmitter

FLOWave SAW-Flowmeter

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Insertion Flow sensor for continuous flow measurement

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

Digital inductive conductivity transmitter

Conductivity Transmitter

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

ph or ORP Transmitter

BPF8020. Insertion Paddle Wheel Flowmeter

Ultrasonic level transmitter, non-contact

Ultrasonic level measuring device, non-contact

Universal process controller econtrol

Universal process controller econtrol

The transducer component converts the measured signal and displays the actual value.

OEM radar transmitter, for aggressive media level measurement

Valve Island with Electronic I/O

Digital conductivity transmitter

Paddle wheel flow controller for On/Off control

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

Conductivity sensor for hygienic applications

Universal process controller econtrol

2/2 way Proportional Valve (motordriven)

2/2-Way Solenoid Control Valve

Technical Information Smartec CLD18

Technical Information Smartec CLD18

Design and applications

Explosion proof rotary actuator - On/Off or programmable regulating actuator

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Magnetic Inductive Flow Sensor induq

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

Magnetic Inductive Flow Sensors induq. Series VMI

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

Magnetic-Inductive flow Meter fmi

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

USER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER. Rev USER MANUAL DEI MODEL USFT-B

Product Overview Sensors, Transmitters and Controllers

DUK COMPACT ULTRASONIC FLOWMETER

Technical Information Smartec CLD18

Product Overview Sensors, Transmitters and Controllers

RCM DIRECT READING FLOWMETER

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS

KFS. Flap-type flow meter. Design and range of application

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

Ambient Conditions. Operating Conditions. Pressure

Mass Flowmeter CoriolisMaster FCM2000

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

OPTIFLUX 5000 Technical Datasheet

FLOMID FX Electromagnetic Flowmeter

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

High-quality pressure transmitter For general industrial applications Model S-10

OPTIMASS 1000 Technical Datasheet

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

TIDALFLUX 2300 F Technical Datasheet

Electromagnetic flowmeters and switches DWM 1000/2000

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

BATCHFLUX 5500 C Technical Datasheet

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Magnetic Inductive Flow Sensors VMI Series

OPTIFLUX 5000 Technical Datasheet

Ult r a s o n i c le v e l me t e r s ULM 55

SM-15. Features. Plastic Flowmeters as per the Variable Area Principle. Description: Application:

DUK. Compact Ultrasonic Flowmeter

Electronic temperature switch with display Model TSD-30

Float switch For industrial applications, plastic version Model RLS-2000

DVZ COMPACT VORTEX FLOWMETER

Pressure transmitter for general industrial applications Model A-10

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Pressure transmitter For general industrial applications Model A-10

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

Positive Displacement Flow sensors

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

Электромагнитные пропорциональные клапаны Burkert

Mass Flowmeter CoriolisMaster FCM2000

Model Sono-Trak Transit Time

Relative and absolute pressure transmitter type 528

Magnetic Inductive Flowmeter

Pressure transmitter for general industrial applications Model A-10

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

Electromagnetic flowmeter in all metal design Model MIM

4/3 Proportional Directional Valve, Size SAE 10

Plug & Play. No Calibration Required

Electronic Pressure Switch Type MEP

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

Transcription:

INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection to Bürkert devices in remote versions Type 8030 can be combined with Type 86 econtrol universal controller Type 80 Flow transmitter Type 869 multicell transmitter/controller Type 880 ELEMENT control valve system The paddle wheel flowmeter for continuous flow measurement is especially designed for use with neutral, slightly aggressive, solid free liquids. The flowmeter is made up of a compact sensor-fitting (S030) and a transmitter (SE30) quickly and easily connected together by a quarter-turn. The Bürkert designed sensorfitting system ensures simple installation of the devices into all pipes from DN06 DN6. The flowmeter produces a frequency signal, proportional to the flow rate, which can easily be transmitted and processed by a Bürkert transmitter/controller. General technical data Compatibility Materials Housing, cover, male connector Cable plug / seal / screws Wetted parts materials Sensor-fitting, sensor armature Paddle wheel Axis, bearing / Seal With Bürkert S030 INLINE sensor-fittings (see corresponding datasheet) PC PA / NBR / Stainless steel Brass, stainless steel.4404/36l, PVC, PP, PVDF PVDF Ceramics / FKM or EPDM (depending on sensor-fitting version) Electrical connection Cable plug EN 730-803 (Type 08) Connection cable max.. mm cross section; max. 0 m length, shielded Complete device data (sensor-fitting S030 + transmitter SE30) Pipe diameter DN06 DN6 Measuring range 0.3 m/s Fluid temperature with sensorfitting in PVC / PP Stainless steel, brass, PVDF Fluid pressure max. 0 + 0 C (+ 3 + F) / 0 + 80 C (+ 3 + 76 F) - + 0 C (+ + F) PN (with plastic sensor-fitting), PN6 (with metal sensor-fitting); (PN40 on request, see S030 datasheet) - see pressure/temperature chart 300 cst. max. / max. % (Size of particles 0. mm max.) Viscosity / Pollution Measurement deviation Teach-In ± % of Reading ) (at the teach flow rate value) Standard K-factor ±. % of Reading ) Linearity ± 0. % of F.S.* ) Repeatability ± 0.4 % of Reading ) Environment Ambient temperature - + 60 C (+ + 40 F) (operating and storage) Relative humidity 80 %, without condensation * F.S. = Full scale ( m/s) ) Under reference conditions i.e. measuring fluid = water, ambient and water temperature = 0 C (68 F), while maintaining the minimum inlet and outlet distances and the appropriate internal diameter of the pipes. ) = measurement bias as defined in the standard JCGM 00:0 www.burkert.com /

Electrical data Operating voltage Current consumption Hall version Hall Low power version Output: Frequency Hall version 36 V DC filtered and regulated (via Bürkert transmitter the device is connected for Low Power version) with sensor 30 ma 0.8 ma transistors NPN and PNP, open collector, max. 0 ma, frequency: 0 300 Hz; duty cycle ½ ± % NPN output: 0. 36 V DC PNP output: supply voltage transistor NPN, open collector, max. ma, Hall Low Power version frequency: 0 300 Hz; duty cycle ½ ± % Reversed polarity of DC Protected Standards, directives and certifications Protection class IP6 with connector plugged-in and tightened Standards and directives Pressure (S030 sensor-fitting, DN06 DN6, in PVC, PP, PVDF, stainless steel or brass The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable) Complying with article 4, of 04/68/EU directive* * For the 04/68/EU pressure directive, the device can only be used under the following conditions (depends on max. pressure, pipe diameter and fluid). Type of Fluid Conditions Fluid group, article 4,.c.i DN Fluid group, article 4,.c.i Fluid group, article 4,.c.ii Fluid group, article 4,.c.ii DN 3 or PN*DN 00 DN or PN*DN 000 DN 00 or PN or PN*DN 000 If the device is mounted in a humid environment or outside, then the maximum voltage allowed is 3 V DC instead of 36 V DC. Pressure/temperature chart Pressure (bar) 8 6 4 8 6 4 A 0-0 0 0 40 60 80 0 Fluid temperature C PVDF PVC PP Metal A: Application range for complete device (sensor-fitting + transmitter) /

8030 / SE30 Design and operating principle The 8030 device is made up of a compact INLINE sensor-fitting (S030) equipped with a sensor with paddle wheel and a transmitter (SE30). In a 3-wire system, the signal can be displayed or processed directly. The output signal is provided via cable plug according to EN 730-803. When liquid flows through the pipe, the paddle wheel with 4 inserted magnets is set in rotation, producing a measuring signal in the sensor (Hall sensor). The frequency modulated induced voltage is proportional to the flow velocity of the fluid. A conversion coefficient (K-factor in Pulse/l available in the instruction manual of the sensor-fitting), specific to each pipe (size and material) enables the conversion of this frequency into flow rate Two transmitter versions with frequency output are available: - with two transistor outputs NPN and PNP. An external power supply of 36 V DC is required. It is designed for connection to any system with open collector NPN or PNP frequency input. - with one NPN transistor Low Power output. An external power supply of 36 V DC is required. Can only be connected to remote versions of flow transmitters Type 80/803. Installation The sensor-fitting (S030) ensures simple installation into pipes from DN06 DN6. The transmitter SE30 can easily be installed into any Bürkert INLINE sensor-fitting system (S030), by means of a quarter-turn. Minimum straight upstream and downstream distances must be observed. According to the pipe s design, necessary distances can be bigger or use a flow conditioner to obtain the best accuracy. Fore more information, please refer to EN ISO 67-. EN ISO 67- prescribes the straight inlet and outlet distances that must be complied with when installing sensor-fittings in pipe lines in order to achieve calm flow conditions. The most important layouts that could lead to turbulence in the flow are shown below, together with the associated prescribed minimum inlet and outlet distances. These ensure calm, problem-free measurement conditions at the measurement point. DN = Orifice Fluid direction Regulating valve* x 90 elbow joint Expansion** 0 x DN x DN x DN x DN 8 x DN x DN x 90 elbow joint 3 dimensional 90 elbow joint or T-piece Reduction 40 x DN x DN 0 x DN x DN * If the valve cannot be mounted after the measuring device, the minimal distances have to be respected. ** If an expansion cannot be avoided, the minimal distances have to be respected. x DN x DN The device can be installed into either horizontal or vertical pipes. Important criteria for this are; ensure that the measurement pipe is fully filled and that the measurement pipe is air bubble free. Pressure and temperature ratings must be respected according to the selected sensor-fitting material. The suitable pipe size is selected using the diagram flow rate/velocity/dn. The flowmeter is not designed for gas and steam flow measurement. 3/

Diagram flow rate/velocity/dn Example: Specification of nominal flow: m 3 /h Ideal flow velocity: 3 m/s For these specifications, the diagram indicates a pipe size of DN40 (or DN0 for (*) mentioned sensor-fittings) Flow rate gpm 00 00 00 0 l/min 3000 000 00 00 m 3 /h 00 0 0 0 Not recommended DN6 DN0 (DN6)* DN40 (DN0)* DN3 (DN40)* DN (DN3)* 0 00 DN0 (DN)* 0 0 DN (DN or DN0)* 0 DN08 0 DN06 0. 0. 0. 0. 0. 0.0 0. 0. 0.0 0.0 0. 0.0 0. 0.3 0. 3 0.3 0. 3 30 fps Flow velocity * for following sensor-fittings with: external threads acc. to SMS 4 weld ends acc. to SMS 3008, BS48-/ASME BPE/DIN 866 series C or DIN 80 series /DIN 866 series A/DIN EN 37 series A Clamp acc. to SMS 307, BS 48-3/ASME BPE or DIN 3676 series A m/s Dimensions [mm] of 8030 flowmeter Transmitter SE30 3 9 40 66 H DN H with S030 sensor-fitting 06 9. 08 9. 0. 0 98.0 98.0 3.0 40. 0.0 6.0 44 Flowmeter 4 4/

Ordering chart for flowmeter Type 8030 A complete 8030 flowmeter consists of an SE30 flow transmitter and a Bürkert S030 INLINE sensor-fitting. The following information is necessary for the selection of a complete device: Article no. of the desired SE30 flow transmitter (see ordering chart, below) Article no. of the selected S030 INLINE sensor-fitting (DN06 DN6, see separate datasheet) You have to order the two components separately. SE30 flow transmitter Description Voltage supply Output Electrical connection Article no. Hall version flowmeter (connectable to 36 V DC Frequency, transistors NPN and Cable plug EN 730-803 4393 Type 80 universal transmitter, batch controller or konti-dos; 803; 869; PNP PLC) Hall Low Power version flowmeter (connectable to Types 80, 803 transmitter) from associated transmitter Frequency, transistor NPN Cable plug EN 730-803 4394 Ordering chart for accessories (has to be ordered separately) Specifications Cable plug EN 730-803 with cable gland (Type 08) Cable plug EN 730-803 with NPT ½" reduction without cable gland (Type 09) Article no. 4388 6673 Interconnection possibilities with other Bürkert products Type 80 Universal, konti-dos flow transmitter/batch controller Type 803 Flow switch/transmitter Type 80 Flow transmitter Type 803 Flow switch/transmitter PLC Type 8030 Flowmeter with Hall transducer (NPN and PNP transistor outputs) Type 8030 Flowmeter with Hall Low Power transducer (NPN output) To find your nearest Bürkert facility, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. Subject to alteration. Christian Bürkert GmbH & Co. KG 80/_EU-en_0089778 /