MULTIBLOC 4a.ST8 Size 4a, 690VAC, 1600A, 690VAC, Design for Bottom Fitting, 1-, 3-pole

Similar documents
MULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole

NH Plastic Bases. NH Plastic Bases IEC NH FUSE BASES FEATURES & BENEFITS APPLICATIONS STANDARDS TECHNICAL DATA OVERVIEW

400 Va.c., 500 Va.c., 690 V a.c. Rated current I n. 120 ka

isw switches Control Local control IEC/EN , isw switch with indicator light. IEC/EN , isw switch without indicator light.

Fuse Links NV/NH gg with Striker Pin Dimensions

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

NS..S contactor relays - with spring terminals AC operated

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

Type CP-S, CP-C & CP-A Switch mode

Technical features table for miniature circuit-breakers SH 200 Series

Modular equipment. Presentation, standards. Standard contactors TeSys GC

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

Current transformers TI current transformers 0

Control module CP-A CM

COMPONENTS. Power contactor Type BMS09.08 / BMS18.08

Control Stations ø 22

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Use RH covers when starting with a LH feed unit or when reaching the LH board. HIGH RATING

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

Three-phase monitoring relays CM-PFE and CM-PFE.2

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Safety switches with slotted hole lever

Complete units: Mushroom heads ø 22mm

Complete units: Push-buttons ø 22mm

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

FM series position switches

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

MEDIUM VOLTAGE PRODUCT. PARAMETERS GUIDE How to specify the indoor instrument transformers correctly

Complete units: Selector switches ø 22mm

NZMH4, NZM(H)6(B), NZM(H)9, NZM12 Technical Data

Type: DILM40(RDC24) Article No.:

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Operator Heads: ø 22mm

3 - Protection components Circuit-breakers

Maintenance/Connection/Installation Service life C/O cyclesx1000

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A

Installation and Operating Instructions for Phase Demodulator Type _.2

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description:

4/2 Introduction. Marshaling Boxes 4/8 8GK1 surface-mounting distribution boards

EN 50178, IEC

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Moeller Electric Corporation

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Thermistor motor protection relays

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts

Separate units: Blocks

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Position switches FM series

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Operator Heads: ø 22mm

Modular Devices and Enclosures

Coupling Relays and Converters

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Semiconductor contactors, Solid-state relays

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

TRANSFORMERS FOR GIS APPLICATIONS VOLTAGE VOLTAGE TRANSFORMERS FOR GIS APPLICATIONS

Electronic timer CT-TGD.22

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Electronic timer CT-SDD.22

N. TEST TEST DESCRIPTION

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

Components for safety applications

Characteristics 5 TeSys k contactors and reversing contactors

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Three-phase monitoring relays

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE

Three-phase monitoring relay CM-PFS

2/2 Introduction. Unequipped Distribution Boards 2/5 8GK1 surface and flush-mounting distribution boards

Low voltage switchgear

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

Semiconductor (AC) fuses

Transformers, Power Supply Units and Socket Outlets

Transcription:

MULTIBLOC 4a.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS Touch protection IP 20 Safe on load connection/disconnection in accordance with IEC 609473 The production programme of MULTIBLOC series 4a.ST8 1600 A comprises NH fuse switch disconnectors for 1600A. They are designed for bottom fitting/panel installation and are available in single pole and triple pole units. MULTIBLOC size 4a are designed for NH fuselinks in accordance with IEC/EN 602692, VDE 06362, size 4a. MULTIBLOC offers the user the possibility of fast and easy installation as well as a high degree of security during installation and maintenance. TECHNICAL DATA OVERVIEW Voltage AC 690 VAC Amper (A) 1600 A Size per Standard 4a Ue = AC 400 V; Ie = 1600 A SCCR Ue = AC 500 V; Ie = 1600 A Ue = AC 690 V; Ie = 1600 A Mounting bottom fitting/panel Switchability 1,3pole switching APPLICATIONS Panel boards for industrial use Feeder pillars for industrial use Meter distribution units Measuring transformer cabinets Transmitting stations for telecommunications STANDARDS IEC/EN 60 9473 For NHfuse links size 4a in accordance with IEC/EN 60 2692, VDE 06362 EP.MERSEN.COM 1

PRODUCT RANGE MULTIBLOC 4a.ST8 size 4a 1600A, 690VAC bottom fitting, single pole Catalog Reference Poles Cable termination components Weight kg 1 Package 1.000.084 X1023083 1 2xM12 terminal screws 5.00 1 piece 1.000.084 1 weight in kg per piece or set including package MULTIBLOC 4a.ST8 size 4a 1600A, 690VAC bottom fitting, triple pole Catalog Reference Poles Cable termination components Design Weight kg 1 Package 1.000.091 1.000.091 Y1023084 3 2xM12 terminal screws single pole switching 13.70 1 piece 1.000.092 Z1023085 3 2xM12 terminal screws triple pole switching 13.90 1 piece 1 weight in kg per piece or set including package 1.000.092 EP.MERSEN.COM 2

TECHNICAL DATA IN ACCORDANCE WITH EN / IEC 60947 4a.ST8 single pole 4a.ST8 triple pole Number of poles/phases 1 3 Size 4a 4a Conventional free air thermal current with NHfuse links I th 1600 A 1600 A Max. power dissipation of fuse links P n 140 W 140 W Conventional free air thermal current with solid links I th 1800 A 1800 A Max. power dissipation of solid links P n 42 W 42 W Utilization category to IEC/EN 609473 U e = AC 400 V; I e = 1250 A U e = AC 400 V; I e = 1600 A U e = AC 690 V; I e = 1600 A U e = DC 0 V; I e = 1600 A U e = DC 440 V; I e = 1250 A AC B AC 21 B DC 21 B DC 21 B AC 21 B Rated operational voltage U e 690 V 690 V Rated insulation voltage U i 800 V 800 V Rated impulse withstand voltage U<sub>imp</sub> 8 kv 8 kv Rated frequency 50... 60 Hz 50... 60 Hz Degree of protection IP 20 IP 20 Degree of pollution 3 3 Rated duty uninterrupted duty uninterrupted duty Rated conditional shortcircuit current with fuse links U e = AC 400 V; I e = 1600 A U e = AC 500 V; I e = 1600 A U e = AC 690 V; I e = 1600 A Rated short circuit making capacity with solid links I cm 100 kasw 100 kasw Rated shorttime withstand current I cw 50 ka / 1 s 50 ka / 1 s Power dissipation by I th without NHfuse links 80 W 270 W Power dissipation by I th without solid links 80 W 270 W Installation mode bottom fitting bottom fitting Cable terminal connection Standard cable terminal M16 M16 for copper bars with max. dimensions 50 x 10 mm 50 x 10 mm EP.MERSEN.COM 3

DIMENSIONS MULTIBLOC 4a.ST8 NHfuse switch disconnector single pole design for bottom fitting (M02002) MULTIBLOC 1250A top terminal Ø 18 dimension x = 181.5 126 ±1 MULTIBLOC 1600A flat copper 50 x 10 158 151 35 (1250 A) 39 (1600 A) 233 340 270 50 Ø13 Ø18 333 160 110 104 330 141,5 50 MULTIBLOC 1250A bottom terminal Ø 18 dimension x = 186.5 14 6 172 409 425 mm required to remove switch operating cover Dimensions in mm EP.MERSEN.COM 4

50 110 270 104 MULTIBLOC 4a.ST8 DIMENSIONS MULTIBLOC 4a.ST8 NHfuse switch disconnector triple pole design for bottom fitting (M02003a) flat copper 50 x 6 mm (1250 A) flat copper 50 x 10 mm (1600 A) M16 2 x M12 35 233 330 256 340 160 126 +1,5 126 +1,5 13 126 +1,5 126 +1,5 378 +3 terminal connection 1250 A 1600 A 15 1 158 17 2 409 6 Dimensions in mm 18 50 x 6 20 14 50 x 10 14 EP.MERSEN.COM 5