A New Technology. for Measuring Overhead Line and Cable Impedance Values and the Ground Impedance of Large Substations. Feature

Similar documents
CP Cu1. Advanced Test Equipment Rentals ATEC (2832) Multi-purpose coupling unit for CPC 100. Measurement System for

Diagnostic testing of cast resin transformers

Summary of the Impacts of Grounding on System Protection

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

CP CU1. Coupling unit for line and ground testing

Preface...x Chapter 1 Electrical Fundamentals

Fatima Michael college of Engineering and Technology

INTEGRATED METHOD IN ELECTROMAGNETIC INTERFERENCE STUDIES

Safety earthing. Sector Energy PTI NC. Copyright Siemens AG All rights reserved. Theodor Connor

Experimental Investigations and Calculations in 6-35 kv Networks with Various Neutral Conditions

Field Instruction. Induced voltages can occur in overhead lines, underground cables, or in switchyards.

Specialists in HV and MV test and diagnostics. Testing in Substations

Analysis of lightning performance of 132KV transmission line by application of surge arresters

Overview of Grounding for Industrial and Commercial Power Systems Presented By Robert Schuerger, P.E.

CONTENTS. 1. Introduction Generating Stations 9 40

High Voltage DC Transmission Prof. Dr. S. N. Singh Department of Electrical Engineering Indian Institute of Technology, Kanpur

This webinar brought to you by The Relion Product Family Next Generation Protection and Control IEDs from ABB

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

CP CU1. Reference Manual COUPLING UNIT FOR LINE IMPEDANCE AND K FACTOR MEASUREMENTS, COUPLING MEASUREMENTS ON POWER LINES AND SIGNAL CABLES AND

EMC Philosophy applied to Design the Grounding Systems for Gas Insulation Switchgear (GIS) Indoor Substation

Distance Protection of Cross-Bonded Transmission Cable-Systems

Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables

1. Introduction to Power Quality

Introduce system protection relays like underfrequency relays, rate of change of frequency relays, reverse - power flow

Dielectric analysis of high-voltage power transformers DIAGNOSIS ABSTRACT KEYWORDS. 1. Introduction

High voltage engineering

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

CPC 100. Multi-functional Primary Test System for Substation Commissioning and Maintenance

PRACTICAL PROBLEMS WITH SUBSTATION EARTHING

SAFETY ISSUES RELATED TO THE CONNECTION OF MV AND HV GROUNDING

CP CU1. Reference Manual

Definitions of Technical Terms

PRELIMINARIES. Generators and loads are connected together through transmission lines transporting electric power from one place to another.

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

Topic 6 Quiz, February 2017 Impedance and Fault Current Calculations For Radial Systems TLC ONLY!!!!! DUE DATE FOR TLC- February 14, 2017

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 4 NOVEMBER 2009

ELECTROMAGNETIC INDUCTION AND ALTERNATING CURRENT (Assignment)

Earth Fault Protection

Roll No. :... Invigilator s Signature :.. CS/B.TECH(EE)/SEM-5/EE-502/ POWER SYSTEM-I. Time Allotted : 3 Hours Full Marks : 70

LONGITUDINAL INDUCTION VOLTAGE MEASUREMENT ON COMMUNICATION CABLES RUNNING PARALLEL TO OVERHEAD LINES

Education & Training

Grounding for Power Quality

Power Quality. Case Study. Conrad Bottu Laborelec January 2008

Protective earthing, protective conductor and automatic disconnection in case of a fault (Fault protection)

EMC filters. Mounting instructions. Date: January 2006

Overvoltage Protection

BASIC ELECTRICITY/ APPLIED ELECTRICITY

BASIC ELECTRICITY/ APPLIED ELECTRICITY

Curso de Transmissão em Corrente Continua Rio de Janeiro, de Junho, 2007

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

CPC 100. Multi-functional primary test system for substation commissioning and maintenance

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements

High Voltage Pylon earth Measurements. Tycom (Pty) Ltd Frank Barnes Comtest (Pty) Ltd Presented by Gavin van Rooy

High Voltage Pylon Earth Measurements

ECE 528 Understanding Power Quality

Industrial and Commercial Power Systems Topic 7 EARTHING

What Are We Protecting? Over-Voltage Protection for CP Systems. Personnel (primary) Equipment (secondary)

Device Interconnection

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4

Caution - leakage currents! Leakage currents in fault-current protected environments

The Ins and Outs of Audio Transformers. How to Choose them and How to Use them

EXPERIMENTAL INVESTIGATION OF A TRANSIENT INDUCED VOLTAGE TO AN OVERHEAD CONTROL CABLE FROM A GROUNDING CIRCUIT

C&G Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations. Earth Fault Loop Impedance Tests

N. TEST TEST DESCRIPTION

SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: Document Number: KUCSH0039 Rev: 4

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

Contents. Measurement and checking equipment for transformation centers Micro-ohmmeter MH-10 Page 3. Indirect earth contact simulator TL-5 Page 5

AC Voltage- Pipeline Safety and Corrosion MEA 2015

DesignCon Noise Injection for Design Analysis and Debugging

60Hz Ratings. Typical Applications. Features & Characteristics. Ratings

The study of ferroresonance effects in electric power equipment

WHY YOU NEED A CURRENT BALUN

Basic Electrical Training

TRANSFORMER OPERATION

MS2109A AC/DC Clamp Meter. User Manual. Contents

TDA4439. Video IF Amplifier for Multistandard TV and VTR. Technology: Bipolar. Features. Case: DIP18. TELEFUNKEN Semiconductors

Need for grounding Codes and Standards for grounding Wind Turbine Generator grounding design Foundation + Horizontal Electrode grounding design

Advanced Insulation Diagnostic by Dielectric Spectroscopy

Performing reliable and reproducible frequency response measurements on power transformers

Residual Current Operated Circuit-Breakers (RCCBs)

Power Electronics. Exercise: Circuit Feedback

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

Importance of Grounding in Power System. Presented by Mr. H Jayakumar Ex- Joint Director CPRI

Power Cables and their Application

ANALYSIS OF A FLASHOVER OPERATION ON TWO 138KV TRANSMISSION LINES

Modeling insulation in high-voltage substations

Contents. Core information about Unit

DESIGNING AND MANUFACTURING CURRENT TRANSMITTER ON MV SYSTEMS FOR SMART GRID APPLICATIONS

Grounding and Bonding of Service Equipment

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

6. Internal lightning protection

Power supply CP-E 24/2.5

Electric Power Systems Research

Section 6. Tone Generators & Operation

Electrical Theory. Power Principles and Phase Angle. PJM State & Member Training Dept. PJM /22/2018

1) The diagrams in the section Assembly notes were provided by Rittal GmbH Co. KG, Herborn and by Invensys Systems GmbH EUROTHERM, Limburg/ Lahn.

Stake-less earth / ground testing

Coil Products Beginnings 1960 State of the Art. Customer partnership around the globe. Continuous innovation since 1900

High Voltage DC Transmission Prof. Dr. S. N. Singh Department of Electrical Engineering Indian Institute of Technology Kanpur

Transcription:

Feature A New Technology for Measuring Overhead Line and Cable Impedance Values and the Ground Impedance of Large Substations Introduction The knowledge of overhead line and cable impedances is very important for the correct setting of impedance protection relays. Line-to-line impedances can be calculated with acceptable accuracy, but line-toground impedances have to be measured because the calculation does not fit within the real condition of the specific ground resistance with metallic pipes, cables, and other metallic parts in the ground. Also, the mutual coupling between power lines has to be measured. Conventional measurement principles are: Beat frequency method Test with normal and reverse polarity. These methods need high-test currents to get an acceptable signal-tonoise ratio, and they are not very precise. This article describes a new test method using frequencies different from the line frequency. The resulting excellent noise suppression allows for precise measurements under difficult conditions. u(t) = U Signal Generation and Measurement DSP 15-400Hz Generator Power Amplifier i(t) = I u(t) i(t) Figure 1 cos(ϖt) cos(ϖt) Re {u(t)} Im {u(t)} Re {i(t)} Im {i(t)} by Michael Krüger OMICRON electronics GmbH Austria Measuring Principle The measuring principle is shown in Figure 1. A digital signal processor generates sinusoidal signals in a frequency range of 15 to 400 hertz. This signal is fed to a switched-mode power amplifier. A transformer at the output matches the internal amplifier impedance with the test object impedance. A multiplication of the measured signals with the generated signal, sin(ωt), and the 90 shifted signal, cos(ωt), enables an excellent filtering of the noise and a measurement of the real and imaginary parts with high precision. Thus, complex impedances Z=R+jX can be measured. When the measurements are made at frequencies different from the line frequency, they also can be made under difficult conditions without any interference problems. The impedance value Spring 2005 1

at line frequency can be determined by interpolating the curve impedance versus frequency. The described method is also ideal for ground impedance and coupling measurements. Capacitive and Inductive Coupling Without special equipment, measurements on overhead lines can be quite dangerous. A calculation for 220 kilovolts was made. The capacitive coupled voltage was approximately 48 kilovolts (both ends open), and the current through the coupling capacitance (one end grounded) was approximately 280 milliamperes per kilometer. If a second system on the tower had a fault current of 3000 amperes, the induced voltage in the measured system would be calculated to 400 volts per kilometer, or four kilovolts for the whole length of 10 kilometers. To avoid any danger during the measurements, a special coupling unit was used between the test equipment and the overhead line. A separation transformer with reinforced insulation and measuring transformers allowed a complete potential separation. The coupling unit was situated near the overhead line, far away from the operation unit. Overvoltage arresters made the operation as safe as possible. For such situations, test currents up to 20 amperes can be generated. The ground impedance Z m can be calculated by subtracting Z 1,sym /3 from the ground loop impedance (see Figure 3). (L1+L2+L3) - E Phase L1 Phase L2 Phase L3 Earth Substation A Figure 3 Substation B On-Site Tests In the first example, a measurement was made on a 220-kilovolt overhead line with a length of 80 kilometers (Figure 4). Line Impedance Measurement For determination of the symmetric line impedance, ground impedance, and ground factor (k0), the following measurements are necessary: L1-L2, L2-L3, and L3-L1 loops L1+L2+L3 (in parallel) to ground. The symmetric line impedance Z 1,sym can be easily determined out of the line-to-line impedances (see Figure 2). Phase L1 L3-L1 L1-L2 L2-L3 Phase L2 Phase L3 Earth Substation A Substation B Figure 2 Figure 4 2 NETA WORLD

Figure 5 Figure 6 The whole test could be prepared ahead of time, so the actual measurements of all parameters would take approximately 30 minutes of on-site time. The calculation of Z 1,sym, Z m, and the ground factor k 0 was done automatically (Figure 5). Very often the ground factor is set to one. In this case, a ground factor of 0.47 was measured. If a fault had occurred in the first part of the second zone, the relay would have tripped instantaneously, so the selectivity of the protection was not provided. A second example was measured on a high-voltage cable connection. The length was nine kilometers, and the cable screens were crossbonded. The ground factor of the protection relay was set to 0.8. The measured ground factor was 0.3. It is also interesting to note that the inductive component (X) of the ground impedance was negative. The reason for this was the relatively big inductance between the inner cable conductors (distance between the phases =30 cm) compared to the small inductance between inner conductor and screen, so the difference became negative. Noise Suppression All the measured results in Figures 5 and 6 are interpolated values. The real measurement was made at different frequencies to get the impedance curve over the frequency. In Figure 7, the noise at 50 hertz can be seen clearly. By interpolating the impedance curve for 50 hertz, this value can be determined with high precision. Although high, 50 hertz noise is around. Also, the impedance values at the harmonics can be determined. Figure 7 Spring 2005 3

Current through Earth Wire I L Line Disconnectors Line Disconnectors CPC 100 Test Current I E CP CU20 Overhead Line as auxiliary Wire for the Test Current Earthing Disconnectors 10 x a U 3... 5 x a Auxiliary electrode U Auxiliary electrode I V Measuring Electrode Earth System under Test Current back through the Earth I B Earth System of a second Substation as Auxiliary Earth a Substation ground Figure 9 a Figure 8 Ground Impedance of Large Substations For measuring the ground impedance of substations, the auxiliary line for the current loop should be at least 10 times the maximum longitude of the substation. Otherwise, the potential gradient area of the auxiliary electrode would influence the potential gradient area of the substation ground system, which is measured. For large substations, out-of-service overhead lines or cables are used as auxiliary line. The principle is shown in Figures 8 and 9. Figure 10 shows the ground impedance curve. A distance of more than 2000 meters is needed between the measuring electrode and the substation ground to get the complete impedance value. Due to the measurement of the complex impedance, voltages, which may be induced in the voltage-measuring path, can be eliminated. Normally, not only the ground feeds the current flowing back to the substation, but also all metallic line, tubes, pipes, the ground cable on the tower top, and cable screens feed parts of the current flowing back. Sometimes it is important to determine the current balance of all described paths. This can be done, if the paths are accessible, by using current clamps, which are put around the line. Figure 10 4 NETA WORLD

Earth grip connection points In Figure 11, the principle of ground grid measurement is shown. With this measurement, contact resistances of ground grid connections can be measured and corrosion of the grid itself can be detected. Earth Grid Figure 11 Michael Krüger is product-line manager for primary testing with OMICRON electronics GmbH, Austria. He studied electrical engineering at the University of Aachen (RWTH) and the University of Kaiserslautern (Germany) and graduated in 1976 (Dipl.-Ing.). In 1990 he received the doctorate of technology from the University of Vienna. Michael Krüger has more than 25 years experience in power engineering, particularly in high-voltage engineering and insulation diagnosis. He is member of VDE and IEEE. Spring 2005 5