17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China ADAPTIVE EDDY CURRENT FLAW DETECTORS

Similar documents
DIGITAL PROCESSING METHODS IN EDDY-CURRENT FLAW DETECTION

ELECTROMAGNETIC ON-LINE TESTING OF ROLLED PRODUCTS AND TUBES. PROBLEMS AND SOLUTIONS.

PORTABLE EDDY CURRENT FLAW DETECTOR VD3-81 EDDYCON

2.5D Finite Element Simulation Eddy Current Heat Exchanger Tube Inspection using FEMM

Array Eddy Current for Fatigue Crack Detection of Aircraft Skin Structures

Modern Electromagnetic Equipment for Nondestructive Testing

LOW FREQUENCY ACOUSTIC (IMPEDANCE) FLAW DETECTORS OF THE NEW GENERATION AND THEIR APPLICATION

Magnetic Eddy Current (MEC) Inspection Technique

DETECTION OF THE SUBSURFACE CRACKS PROPAGATED FROM RIVET HOLES IN THE MULTILAYER AIRCRAFT STRUCTURES

PORTABLE EDDY CURRENT FLAW DETECTOR VD3-71 NK-IVU.

Eddy current flaw detector «Eddycon C»

New portable eddy current flaw detector and application examples

Data Processing at the Flaw Detector with Combined Multisector Eddy-Current Transducer

Eddy Current Nondestructive Evaluation Based on Fluxgate Magnetometry Umberto Principio Sponsored by: INFM

VD3-71 universal eddy current flaw detector application for field inspection of aeronautical engineering

PORTABLE EDDY CURRENT FLAW DETECTOR VD3-71 NK-IVU.

High-Precision Internal Diameter Measurements Using Eddy Current Arrays

SonaFlex. Set of Portable Multifunctional Equipment for Non-contact Ultrasonic Examination of Materials

BGA Solder Balls Formation by Induction Heating

R&D of Multi-Frequency ECT Algorithms for FBR SG Tubes

APPROACHES FOR ANALOG FRONT END DESIGN IN ELECTRIC POWER SYSTEM PARAMETERS MEASURING

A Prototype Wire Position Monitoring System

DEEP FLAW DETECTION WITH GIANT MAGNETORESISTIVE (GMR) BASED SELF-NULLING PROBE

Application of Ultrasonic Guided Wave to Heat Exchanger Tubes Inspection

Signal Processing in an Eddy Current Non-Destructive Testing System

A COMBINED ACFM-SMFM SYSTEM FOR REAL-TIME DETECTION AND. S. H. H. Sadeghi and D. Mirshekar-Syahkal

EDDYCON C AIRCRAFT SET OF EDDY CURRENT FLAW DETECTOR FOR AIRCRAFTS TESTING. CE MARKING

Enhancement of Technical Parameters of Eddy-Current Flaw Detectors Designed for Lengthy Metal Products On-Line Examination

PORTABLE EDDY CURRENT FLAW DETECTOR

Modelling III ABSTRACT

Resonant Mode of Inductors with Reactive Power Self-compensation

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

EDDYCON C FOR AIRCRAFTS TESTING. CE MARKING

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

High Resolution Eddy Current Testing of Superconducting Wires using GMR-Sensors

Ripple and Uniformity Measurement of a Phased-Array Testing-Machine for round-bar Testing

IMPROVEMENT OF DETECTION OF SMALL DEFECTS LOCATED NEAR OR FAR FROM WELDS OF MAGNETIC STEAM GENERATOR TUBES USING REMOTE FIELD EDDY CURRENT

D DAVID PUBLISHING. Eddy Current Test for Detection of Foreign Material using Rotating Probe. 2. Theory. 1. Introduction

Inter-Ing INTERDISCIPLINARITY IN ENGINEERING SCIENTIFIC INTERNATIONAL CONFERENCE, TG. MUREŞ ROMÂNIA, November 2007.

Electromagnetic Eddy Current Sensors for Evaluation of Sea-Cure and 2205 Duplex Condenser Tubing

1112. Dimensional evaluation of metal discontinuities by geometrical parameters of their patterns on imaging flaw detector monitor

MEMS Optical Scanner "ECO SCAN" Application Notes. Ver.0

Novel Demagnetization Method after Magnetic Particle Testing

EDDY CURRENT MEASUREMENT OF REMOTE TUBE POSITIONS IN CANDU REACTORS S.T. Craig, T.W. Krause, B.V. Luloff and J.J. Schankula Atomic Energy of Canada

Steam Generator Tubing Inspection

Smartphone turns into eddy current instrument

AA&S Conference 2018 Eddy Current Array for Aircraft

Weld gap position detection based on eddy current methods with mismatch compensation

MATHEMATICAL MODELS OF GEAR TOOTH SPEED SENSORS WITH DUAL OUTPUTS

Step vs. Servo Selecting the Best

Corrosion Assessment of Offshore Oil Pipeline Based on Ultrasonic. Technique

Giant Magnetoresistance Based Eddy-Current Sensor for High-Speed PCB Defect Detection

Testing Critical Medical Tubing Using High Frequency Eddy Current Coils

A Numerical Study of Depth of Penetration of Eddy Currents

MULTI-CHANNEL EDDY CURRENT FLAW DETECTOR VD-ОКО-01.

Application Information

A Portable Magnetic Flux Leakage Testing System for Industrial Pipelines Based on Circumferential Magnetization

2014 EDDY CURRENT BENCHMARK

Telemetrie-Messtechnik Schnorrenberg

Section 1. Fundamentals of DDS Technology

Magnetic Flux Leakage Measurement System to Detect Flaws in Small Diameter Metallic Wire Ropes

Instruction Manual Veritest

Detection and Imaging of Internal Cracks by Tangential Magnetic Field Component Analysis using Low-Frequency Eddy Current Testing

FLAW DETECTION USING ENCIRCLING COIL EDDY CURRENT SYSTEMS

Eddy Current Array for Aerospace

Flexible PCB-Based Eddy Current Array Probes for the Inspection of Turbine Components

Detection of Internal OR External Pits from Inside OR Outside a tube with New Technology (EMIT)

ADVANCED COMBINATION PROBE FOR TESTING FERRITIC SEA-CURE CONDENSER TUBING

A Method for Quantitative Analysis of Transient Eddy Current Testing

A PRACTICAL IMPLEMENTATION OF TRANSIENT EDDY CURRENTS FOR CORROSION AND CRACK DETECTION

CA330 RTD Calibrator: High-speed Response and High-resolution Resistance Simulator

Qualitative Measurement of Moisture Absorption in GFRP Utilizing Electromagnetic Induction

CHAPTER 2 CURRENT SOURCE INVERTER FOR IM CONTROL

A FPGA Based Platform for Multi-Frequency Eddy Current Testing

A SOLUTION TO THE PERMEABILITY AND LIFT-OFF PROBLEMS IN ELECTROMAGNETIC FLAW DETECTION

MULTI-CHANNEL ULTRASONIC FLAW DETECTOR ОКО-22М-UT THE BEST INDUSTRIAL OEM SOLUTION FOR IN-LINE AND IN-SERVICE SYSTEMS

Shielding Effect of High Frequency Power Transformers for DC/DC Converters used in Solar PV Systems

Analysis of Indirect Temperature-Rise Tests of Induction Machines Using Time Stepping Finite Element Method

Usage of Magnetic Field Sensors for Low Frequency Eddy Current Testing

A Novel Self Calibrating Pulsed Eddy Current Probe for Defect Detection in Pipework

Implementation of Transient Eddy Currents from Lab Bench to the Production Environment

EDDY CURRENT TESTING

Fourier Transform. louder softer. louder. softer. amplitude. time. amplitude. time. frequency. frequency. P. J. Grandinetti

CHAPTER 4 CONTROL ALGORITHM FOR PROPOSED H-BRIDGE MULTILEVEL INVERTER

KAERI Feeder Tube Inspection Using EMAT Generated Circumferential Guided Waves

Functional Description

Eddy Current Nondestructive Evaluation Using SQUID Sensors

Position Sensors. The Potentiometer.

Job Sheet 2 Servo Control

MULTI CHANNEL EDDY CURRENT FLAW DETECTOR EDDYCON D

Effect of fatigue crack orientation on the sensitivity of eddy current inspection in martensitic stainless steels

Research & Development of Integrated MMM/EC/MFL Testing System

10. Phase Cycling and Pulsed Field Gradients Introduction to Phase Cycling - Quadrature images

Research Article Miniaturized Circularly Polarized Microstrip RFID Antenna Using Fractal Metamaterial

USE OF INDUCTIVE PROXIMITY SENSORS IN VITAL SIGNAL APPLICATIONS

Global Journal of Engineering Science and Research Management

COMPUTER MODELING OF EDDY CURRENT TRANSMIT-RECEIVE PROBES FOR. S.P. Sullivan, V.S. Cecco, L.S. Obrutsky, D. Humphrey, S.P. Smith and K.A.

Keywords: ultrasonic shadow method, measuring the width of the packaging tape, primary measuring transducers of width.

AVL X-ion. Adapts. Acquires. Inspires.

EMA TRANSFORMATION IN PULSED MAGNETIC FIELD AND ITS USE IN PORTABLE INSTRUMENTS FOR ACOUSTIC MEASUREMENTS

Transcription:

17th World Conference on Nondestructive Testing, 25-28 Oct 28, Shanghai, China ADAPTIVE EDDY CURRENT FLAW DETECTORS Peter N. SHKATOV P, Genndy A. DIDIN, Vadim K. GARIPOV Moscow state university of instrument making and informatics, Russia E-mail: petr_shkatov@mail.ru, 362@mail.ru, garvad@mail.ru For reliable revealing of defects it is necessary to correct adjustment eddy current flaw detector at transition from one controllable object to another or change of conditions of the control. In existing flaw detectors there is an opportunity of creation of the appropriate library of adjustments. However conditions of the control and parameters of controllable object on its various sites can differ. The variant is possible, at which these parameters, for example, type of metal or thickness of a sheeting, beforehand are unknown. Application adaptive eddy current flaw detectors, varying the adjustment automatically in this case is expedient, depending on electromagnetic properties of metal, its thickness, thickness of a sheeting etc. Two are considered new adaptive eddy current flaw detectors «ZOND AVD-96» and «GALS VD-13» below. Flaw detector «GALS VD-13» is designed as a tester with parametrical superimposed eddy current probe. The device is intended only for revealing superficial cracks in any metal objects and works on the fixed frequency. It does not require manual installation of sensitivity of the control and offsetting the interfering factors like a change of a working backlash and eddy current probe axle skew relatively an controllable surface. Depending on a type of metal, identifying by the defect eddy current probe itself, mathematical processing parameters are modified. It supports establishing the necessary sensitivity and suppression of influence of interfering factors. Work of «GALS VD-13» based on fundamental ideas of eddy current testing. When scanning on surface of object, we have complex signal from probe. Real and Imagine components of signal depends on some reasons, such as electrical conductivity, magnetic permittivity, distance between metal surface and probe etc. A small variation of properties makes small variations of signal. In easy case, interesting for us, there are variations of GAP (blue vector) and (red vector) (fig. 1). Im Ferromagnetic Fig. 2. Signals from surface cracks and variations of (lift-off effect) Re Re_IZM,IM_IZM Re_VNOS,IM_VNOS x, x7fffff Non-Ferromagnetic Re_NACH,IM_NACH Re_MAT,IM_MAT Re_VOZD,IM_VOZD BB11,BB21 Picture 1. BB11,BB21= 1 Re_MAT,IM_MAT Fig. 1. Complex plane of eddy current probe x8, x Fig. 3. x, x As we can see, both reasons ( and ) influence on both components (Real and Imagine). To separate the reasons we must rotate signal vector, so that signal from was

horizontally oriented (has only Real component), in such a manner Image component of signal signal from. (fig.2). For a small depth of cracks (less than diameter of probe) Imagine part of signal approximately ratio to depth of crack. Rotation of vector is simple mathematical operation multiplying rotation matrix on vector. Rotation matrix consist of trigonometrically functions (sinus and cosines) of φ angle of rotation. There is easy way to calculate components of rotation matrix. If we have vector A- difference signal between air and metal, we must calculate vector B=1/A. After that we multiply all new signals on vector B (equivalent multiplying on matrix). Signal from automatically will be horizontal. More of that, this way allows make automatic gain change. Another function for the fine tuning of components of rotation matrix delta phi - allows change angle of rotation φ approximately ±7 degrees. It made by multiplying initial matrix on matix 1 Sin(delta) -sin(delta) 1 Because delta angle is small (7 º =.125 rad), we use formula sin(f)=f. Using 1 instead cos(f) we make mistake less than 1% (1/128). PROGRAMM GAINED AMPLIFIER SINUS GENERATOR SINHRO DETECTOR LOW PASS FILTERS ANALOG TO DIGITAL CONVERTER SENSOR MICROPROCESSOR SWITCHING REGULATOR +5v MATRIX INDICATOR 7X5 MATRIX INDICATOR 7X5 Fig. 4. Gals structural scheme. Such, main calculating procedure: Each time ADC sends to microprocessor 24-bit (3-byte) integer number. It stores in RE_IZM or IM_IZM address, depend on selected channel of ADC ( CS, 12 pin of ADS, 11 pin of PIC). Each Compensation procedure (push Metal key, or set REJIM,2 bit) accumulates 256 signals RE_IZM and IM_IZM in RE_VOZD and IM_VOZD addresses conformably.

After first Compensation procedure RE_VOZD and IM_VOZD values loaded to RE_NACH and IM_NACH numbers. It is signals from probe on air. Next Compensation procedures gives RE_VOZD and IM_VOSD signal from probe on crackles metal, more of than difference signal on metal and signal on air is vector of metal properties. RE_MAT=RE_VOZD-RE_NACH IM_MAT=IM_VOSD-IM_NACH If module of this vector quite big, we calculates inverted vector BB11, BB21 and after that rotation matrix AA. The block diagram flaw detector «GALS VD-13» is given in a fig. 4. Due to the developed algorithm flaw detector provides effective отстройку from change of a working backlash (lift-off effect) and is automatically adjusted according to electromagnetic properties of metal of controllable object. One of important for air engineering of tasks consists in detection of corrosion defeats in the plating glider. The similar defects successfully come to light eddy current flaw detector «ZOND VD-96» with eddy current by the converter such as UVTP. The given converter has a stimulating winding with the U-figurative core and measuring windings placed between end faces of the core. Optimum for revealing corrosion defeats the working frequency essentially depends on thickness of the plating, and sensitivity - from thickness of sheetings. It is illustrated a fig. 5. Dependences received on duraluminium plates of various thickness Т (1 mm, 2 mm, 3 mm, 4 mm and 5 mm) with deaf apertures by a diameter of 5 mm and depth h=,1т,,2т and,3т, located with the back party of plates here are given. Uvn, 1 8 6 4 2 U=,53f 3-1,9386f 2 + 29,151f - 3,524 U=,345f 3-2,472f 2 + 23,946f - 14,746 U=,151f 3-1,411f 2 + 12,38f - 11,354 Fig. 5. Dependence U vn from frequency fa Т=3 mm, d=5 mm. h=,9 mm h=,6 mm h=,3 mm 2 4 6 8 1 12 14 frequency, khz optimum frequency, khz 2 15 1 5 fа,max = -7,7594Ln(Т) + 15,83 1 2 3 4 5 6 7 thickness Т, mm Fig. 6. Dependence of optimum frequency fa,max from thickness Т. With accuracy, acceptable to practice, the dependence of optimum frequency f a,max from thickness Т can be submitted by expression f a,max = 7,76 Ln(T) +15,8 (1)

The appropriate dependence is given in a fig. 6. At change of distance Z from eddy current of the converter up to a surface of metal the pressure brought in by defect, changes under the law close to an exhibitor. The appropriate dependences are given in a fig. 7, where То=Т-h. Thus, it is necessary to correct working frequency and sensitivity. At change of distance Z from eddy currentof the converter up to a surface of metal the pressure, brought in by defect, changes under the law close to an exhibitor. Thus, it is necessary to correct working frequency and sensitivity flaw detector depending on thickness Т, backlash Z and depth of defect h.,7,6,5,4,3,2,1 Н д То=1, mm 1,1 mm 1,2 mm 1,3 mm 1,4 mm 1,5 mm 1,6 mm 1,7 mm 1,8 mm 1,9 mm Z, mm, 1, 2, 3, 4, 5, 6, Fig. 7. Dependence Н д,max = Н д,max (Z,T ): f=44 KHz, Т=2 mm. On a basis analysis of researches «ZOND AVD-96» with modernized eddy current by the converter such as UVTP-M ensuring complete automation of process of measurements was developed adaptive eddy current flaw detector. The device has three channels: first - flaw detector, second - measurement of a backlash and third - measurement of thickness. The block diagram of the device is submitted in a fig. 8. Fig. 8. The block diagram adaptive eddy current flaw detector «ZOND AVD-5»

Flaw detector contains modernized eddy current converter UVTP-M, generator, flaw detector channel, channel of measurement of a working backlash and channel of measurement of frequency, analog-digital converter, processor and indicator. Each of measuring channels contains the synchronous detector SD, connected by an alarm input through the amplifier to the appropriate winding eddy current converter and basic input to an output of synthesization. The modernized converter UVTP - М has two additional measuring windings. The measuring winding of the channel of measurement of a working backlash is placed on a lateral surface of the П-figurative core, and channel of measurement of thickness - covers ferromagnetic core. The received information on size of a working backlash allows automatically to correct sensitivity on flaw detector to the channel and channel of measurement of thickness according to changes of a working backlash, for example, because of presence varnished of coverings or layer hermetic. The choice of working frequency of the device is carried out by results of measurement of thickness according to the received expression (1).