Safety Instructions Proline Promass 300

Similar documents
Safety Instructions Proline Promag 500

Safety Instructions Proline Promass 100

Proline Promass 83, 84

Proline Promass 40. Safety Instructions. NEPSI Zone 1, Zone 21

Power supply. Calibration. Surface finishing. Seal. Process connection

Safety Instructions Micropilot NMR81, NMR84

PROline promag 53 Division 1

FM Control Drawing Class I Division 2 / Class I Zone 2. Compact version PROMAG 10

Safety Instructions Nivotester FTC625, FTC325

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

User's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R

Ex instruction manual. Rotamass Coriolis mass flow meter. IECEx. IM 01U10X02-00EN-R_002, 2nd edition,

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

OPTIWAVE 7300 C Supplementary instructions

ProcessMaster, HygienicMaster FEX300, FEX500

Ex instruction manual. Rotamass Coriolis mass flow meter ATEX. IM 01U10X01-00EN-R_002, 2nd edition,

Attachment to Certificate IECEx PTB X

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

ATEX Installation Drawings and Instructions

FLEX Ex V ac In/Quad-Ex dc Out Power Supply

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

FLEX Ex Power Supplies

Coriolis Massflowmeter

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis Mass Flowmeter

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

ProcessMaster / HygienicMaster

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

CERTIFICATE OF COMPLIANCE

Rosemount 5408 and 5408:SIS Level Transmitters

Coriolis Massflowmeter

Special Documentation Levelflex FMP51, FMP52, FMP55, FMP57

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Rosemount 5400 Series Radar Level Transmitter

DPharp Differential Pressure and Pressure Transmitters

Level Measurement Continuous level measurement Radar transmitters

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

INSTRUCTION MANUAL (ATEX / IECEx)

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

Industrial Pressure Transducers

Compact Orifice Flow Meter

Proline Promass F 300, 500

Certificate of Compliance

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Technical Information Cubemass

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

ATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier

Technical Information CNGmass DCI

Intrinsic Safety Control Drawing

Coriolis Mass Flow Meter Model TM

Brief Operating Instructions Proline Promag 50

[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011

Technical Information LPGmass

Technical Information LNGmass

JB/T Translated English of Chinese Standard: JB/T

TMU. Coriolis Mass Flow Meter. for liquids and gas

Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc

Flow Measurement SITRANS F M

OPTIMASS / 300 / 010 Guidelines for the use of Coriolis meters in hazardous areas

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Rosemount 753R Remote Web Based Monitoring Indicator

Certificate of Compliance

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Isolators A3/1.

CERTIFICATE OF COMPLIANCE

Description of equipment

General Specifications

Fisher 4200 Series Electronic Position Transmitters

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Single-Channel Safety Barriers Series 9001

The World's Most Versatile Range of. Coriolis Flowmeters

Technical Information Condumax CLS15D/CLS15

Condumax CLS21 and CLS21D

Installation guide 971 SmartRadar LTi

Coriolis Massflowmeter

FM Safety Manual. Omni-ID UHF Tags

Condumax CLS15 and CLS15D

Indumax CLS50/CLS50D. Technical Information

Technical Information Nivector FTC968, FTC968Z

Alphaline Temperature Transmitters

The World's Most Versatile Range of. Coriolis Flowmeters

The World's Most Versatile Range of. Coriolis Flowmeters

OriMaster FPD500 Compact orifice flowmeter. Orifice-based flow metering made simple

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Inductive sensor slot-type SI2-K08-AP7

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters

Condumax W CLS15 and CLS15D

CNGmass DCI. Technical Information. Coriolis mass flow measuring system For fueling with compressed natural gas (CNG)

The World's Most Versatile Range of. Coriolis Flowmeters

Technical Information Proline Prosonic Flow B 200

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

Transit Time Ultrasonic Flow Measuring System PROline prosonic flow 93 P

RMA42. Technical Information

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Proline Prosonic Flow B 200

Transcription:

XA01507D/06/EN/01.16 71327925 Products Solutions Services Safety Instructions Proline Promass 300 Class I, Zone 2 AEx/Ex na ic IIC Class I, Zone 2, AEx/Ex na nc ic IIC Class I Division 2 C US Document: XA01507D Safety instructions for electrical apparatus for explosionhazardous areas classified according to the National Electrical Code (NEC) and Canadian Electrical Code (CEC) 3

Proline Promass 300 XA01507D Proline Promass 300 Table of contents Associated documentation... 4 Manufacturer's certificates... 5 Extended order code... 5 Safety instructions: General... 8 Safety instructions: Installation... 8 Temperature tables... 9 Connection data: Signal circuits... 21 Endress+Hauser 3

XA01507D Proline Promass 300 Associated documentation All documentation is available: On the CD-ROM supplied (not included in the delivery for all device versions). Available for all device versions via: Internet: www.endress.com/deviceviewer Smart phone/tablet: Endress+Hauser Operations App In the Download Area of the Endress+Hauser web site: www.endress.com Download This document is an integral part of the following Operating Instructions: Measuring device Documentation HART FOUNDATION Fieldbus PROFIBUS PA Modbus RS485 Promass A 300 BA01482D BA01515D BA01504D BA01493D Promass E 300 BA01484D BA01517D BA01506D BA01495D Promass F 300 BA01485D BA01518D BA01507D BA01496D Promass H 300 BA01486D BA01519D BA01508D BA01497D Promass I 300 BA01487D BA01520D BA01509D BA01498D Promass O 300 BA01488D BA01521D BA01510D BA01499D Promass P 300 BA01489D BA01522D BA01511D BA01500D Promass Q 300 BA01490D BA01523D BA01512D BA01501D Promass S 300 BA01491D BA01524D BA01513D BA01502D Promass X 300 BA01492D BA01525D BA01514D BA01503D Additional documentation: Document type Contents Documentation code Special documentation Safety instructions Control drawing Remote display and operating module DKX001 Remote display and operating module DKX001: Class I, Zone 2, Class I Division 2 SD01763D XA01513D As wanted on the nameplate. Please note the documentation associated with the device. 4 Endress+Hauser

Proline Promass 300 XA01507D Manufacturer's certificates Certificate number CSA 16.70087388 Notified body CSA: Canadian Standards Association Extended order code The extended order code is indicated on the nameplate, which is affixed to the device in such a way that it is clearly visible. Additional information about the nameplate is provided in the associated Operating Instructions. Structure of the extended order code * * * * * * _ * * * * * * * * * * + A*B*C*D*E*F*G* Device type Basic specifications Optional specifications * = Spaceholder: At this position, an option (number or letter) selected from the specification is displayed instead of the placeholders. Device type The device and the device design is defined in the "Device type" section (Product root). Basic specifications The features that are absolutely essential for the device (mandatory features) are specified in the basic specifications. The number of positions depends on the number of features available. The selected option of a feature can consist of several positions. Optional specifications The optional specifications describe additional features for the device (optional features). The number of positions depends on the number of features available. The features have a 2-digit structure to aid identification (e.g. JA). The first digit (ID) stands for the feature group and consists of a number or a letter (e.g. J = test, certificate). The second digit constitutes the value that stands for the feature within the group (e.g. A = 3.1 material (wetted parts), inspection certificate). More detailed information about the device is provided in the following tables. These tables describe the individual positions and IDs in the extended order code which are relevant to hazardous locations. Endress+Hauser 5

XA01507D Proline Promass 300 Device type Item Order code for Selected option Description 1 Instrument family 8 Coriolis flowmeter 2 Sensor A, E, F, H, I, O, P, Q, S, X Sensor type 3 Transmitter 3 Transmitter type: 4-wire, compact version 4 Generation index B Platform generation 5, 6 Nominal diameter 1 to 350 1: 01 2: 02 to 350: 3E, 3F, 3R Nominal diameter of sensor Basic specifications Position 1, 2 Order code for "Approval" Option selected Type of protection Transmitter Sensor CS Cl.I, Div.2, Gps. A-D Cl.I, Div.2, Gps. A-D CZ Cl.I, Zone 2, AEx/Ex na nc IIC... Gc 1) Cl.I, Zone 2, AEx/Ex na IIC... Gc Cl.I, Zone 2, AEx/Ex na nc IIC... Gc 2) 1) The marking Ex na nc [ic] IIC Gc is only available for devices with order code "Output; Input 1", option HA or TA 2) The marking Ex na nc is only applicable for sensor versions without purge connection or rupture disk. Position Order code for Option selected Description 4, 5 Output, input 1 BA 4-20mA HART GA HA MA SA TA PROFIBUS PA PROFIBUS PA Ex-i Modbus RS485 FOUNDATION Fieldbus FOUNDATION Fieldbus Ex-i 6 Output, input 2 A W/o; B C D E F 4-20mA 4-20mA Ex-i Configurable I/O initial setting off Pulse/freq./switch output Pulse output, phase-shifted 6 Endress+Hauser

Proline Promass 300 XA01507D Position Order code for Option selected Description G H I J Pulse/freq./switch output Ex-i Relay 4-20mA input Status input 7 Output, input 3 A W/o; B C D E F G H I J 4-20mA 4-20mA Ex-i Configurable I/O initial setting off Pulse/freq./switch output Pulse output, phase-shifted Pulse/freq./switch output Ex-i Relay 4-20mA input Status input 8 Display, Operation A W/o; via communication F G 4-line, illuminated; touch control 4-line, illuminated; touch control + WLAN 17, 18 Device model A1 1 M W/o; prepared for remote display DKX001 1) O Separate, with remote display DKX001 1), 4-line, illuminated; 10m/ 30ft cable; touch control 1) DKX001 is approved according to CSA 160686-70030937. Optional specifications ID Order code for Option selected Description Jx Test, Certificate JP Ambient temperature of measuring device 50 C Cx Sensor option CA Rupture disk Cx Sensor option CH Rinse connection Endress+Hauser 7

XA01507D Proline Promass 300 Safety instructions: General Staff must meet the following conditions for mounting, electrical installation, commissioning and maintenance of the device: Be suitably qualified for their role and the tasks they perform. Be trained in explosion protection. Be familiar with national regulations (e.g. CEC or NEC). Install the device according to the manufacturer's instructions and national regulations. Do not operate the device outside the specified electrical, thermal and mechanical parameters. Only use the device in media to which the wetted materials have sufficient durability. Refer to the temperature tables for the relationship between the permitted ambient temperature for the sensor and/or transmitter, depending on the range of application, and the temperature classes. Modifications to the device can affect the explosion protection and must be carried out by staff authorized to perform such work by Endress+Hauser. Observe all the technical data of the device (see nameplate). LWARNING Substitution of components is not permitted. Substitution of components may impair suitability for Class I, Division 2. Safety instructions: Installation In the event of potentially explosive vapor/air mixtures, only operate the device under atmospheric conditions. Temperature: 20 to +60 C Pressure: 80 to 110 kpa (0.8 to 1.1 bar) Air with normal oxygen content, usually 21 % (V/V) If no potentially explosive mixtures are present, or if additional protective measures have been taken, the device may also be operated under non-atmospheric conditions in accordance with the manufacturer's specifications. 8 Endress+Hauser

Proline Promass 300 XA01507D Continuous service temperature of the connecting cable: 40 to +80 C ( 50 to +80 C for optional specification, ID Jx (Test, Certificate) = JP); but at least according to the service temperature range of the application taking into account additional influences of the process conditions (,min and,max + 20 K). Only use certified cable entries suitable for the application. Observe selection criteria as per CEC or NEC. When the measuring device is connected, attention must be paid to explosion protection at the transmitter. In potentially explosive atmospheres: Do not disconnect the electrical connection of the power supply circuit when energized. Do not open the connection compartment cover when energized. Install the transmitter circuit wiring according to Canadian Electrical Code (CEC) respective National Electrical Code (NEC) using threaded conduit or other wiring methods in accordance with articles 500 to 510. AEx/Ex na type of protection In potentially explosive atmospheres: Do not disconnect the electrical connection of the power supply circuit. Seal unused entry glands with approved sealing plugs that correspond to the type of protection. The plastic transport sealing plug does not meet this requirement and must therefore be replaced during installation. Only use certified cable entries or sealing plugs. The metal sealing plugs supplied meet this requirement. When operating in Zone 2 type of protection AEx/Ex na: Ensure that temporary interference does not cause the maximum operating voltage to be exceeded by more than 40 % (see nameplate). Intrinsic safety Observe the guidelines for interconnecting intrinsically safe circuits (e.g., Proof of Intrinsic Safety). Potential equalization Integrate the device into the local potential equalization. If the ground connection has been established via the pipe as specified, it is also possible to integrate the sensor into the potential equalization system via the pipe. Temperature tables Ambient temperature Minimum ambient temperature: = 40 C Endress+Hauser 9

XA01507D Proline Promass 300 Maximum ambient temperature: = +60 C depending on the medium temperature and temperature class Medium temperature Minimum medium temperature: Promass A, F, H, I, P, Q, S, X: T m = 50 C Promass E, O: T m = 40 C Promass F, Q with cryogenic temperature version (order code for "Measuring tube material", Option LA): T m = 200 C Maximum medium temperature: T m for depending on the maximum ambient temperature ( ) = The maximum permitted medium temperatures in brackets only apply if the sensor is installed in such a way that the transmitter is not mounted above the sensor and free convection can occur on all sides. Promass A Compact version Without thermal insulation T m 1 4 50 205 90 1) 130 170 2) 205 205 60 130 170 2) 205 205 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 195 C Promass E T m 8 15 50 150 80 1) 115 2) 150 150 150 55 115 2) 150 150 150 60 (115 2) ) (140 3) ) (150) (150) 25 80 50 150 80 1) 95 2) 140 3) 150 150 10 Endress+Hauser

Proline Promass 300 XA01507D T m 55 95 2) 140 3) 150 150 60 (95 2) ) (140 3) ) (150) (150) 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 130 C 3) For sensors with type of protection Ex na nc applies: T m = 150 C Promass F 1) T m 08 15 50 150 2) 80 3) 115 4) 150 150 150 60 115 4) 150 150 150 50 240 80 3) 115 4) 170 5) 240 240 55 115 4) 170 5) 240 240 60 115 4) 170 170 (240) 170 (240) 25 80 50 150 2) 60 3) 95 4) 150 150 150 60 95 4) 150 150 150 50 240 60 3) 95 4) 160 5) 240 240 55 95 4) 160 5) 240 240 60 95 4) 150 6) 170 (240) 170 (240) 50 350 85 3) 120 4) 185 5) 280 7) 350 60 120 4) 185 5) 280 7) 350 100 250 50 150 2) 60 3) 95 4) 150 150 150 60 95 4) 150 150 150 50 240 60 3) 95 4) 160 5) 240 240 Endress+Hauser 11

XA01507D Proline Promass 300 1) T m 55 95 4) 160 5) 240 240 60 95 4) 160 6) 170 (240) 170 (240) 1) Maximum temperature range see nameplate 2) Cryogenic temperature version: T m = -196 150 C 3) For sensors with type of protection Ex na nc applies: T m = 95 C 4) For sensors with type of protection Ex na nc applies: T m = 130 C 5) For sensors with type of protection Ex na nc applies: T m = 195 C 6) For sensors with type of protection Ex na nc applies: T m = 170 C 7) For sensors with type of protection Ex na nc applies: T m = 290 C Promass H T m 8 50 150 1) 80 2) 115 3) 150 150 150 60 115 3) 150 150 150 8 50 205 4) 80 2) 115 3) 165 5) 205 205 60 115 3) 165 5) 205 205 15 50 50 150 1) 60 2) 95 3) 130 6) 150 150 60 95 3) 130 6) 150 150 15 50 50 205 4) 60 2) 95 3) 130 5) 205 205 60 95 3) 130 5) 205 205 1) Measuring tube material tantalum 2) For sensors with type of protection Ex na nc applies: T m = 95 C 3) For sensors with type of protection Ex na nc applies: T m = 130 C 4) Measuring tube material zirconium 5) For sensors with type of protection Ex na nc applies: T m = 195 C 6) For sensors with type of protection Ex na nc applies: T m = 150 C 12 Endress+Hauser

Proline Promass 300 XA01507D Promass I T m 8 80 50 150 60 1) 95 2) 150 150 150 55 95 2) 150 150 150 60 (95 2) ) (150) (150) (150) 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 130 C Promass O T m 80 250 50 205 60 1) 95 2) 160 3) 205 205 55 95 2) 160 3) 205 205 60 95 2) 160 4) 180 (205) 180 (205) 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 130 C 3) For sensors with type of protection Ex na nc applies: T m = 195 C 4) For sensors with type of protection Ex na nc applies: T m = 180 C Promass P 1) T m 8 50 150 80 2) 115 3) 150 150 150 60 115 3) 150 150 150 50 205 80 2) 115 3) 170 4) 205 205 60 115 3) 170 4) 205 205 15 50 50 150 60 2) 95 3) 150 150 150 60 95 3) 150 150 150 Endress+Hauser 13

XA01507D Proline Promass 300 1) T m 50 205 60 2) 95 3) 160 4) 205 205 60 95 3) 160 4) 205 205 1) Maximum temperature range see nameplate 2) For sensors with type of protection Ex na nc applies: T m = 95 C 3) For sensors with type of protection Ex na nc applies: T m = 130 C 4) For sensors with type of protection Ex na nc applies: T m = 195 C Promass Q 1) T m 25 100 50 205 60 2) 95 3) 160 4) 205 205 60 95 3) 160 4) 205 205 25 100 50 150 5) 60 2) 95 3) 150 150 150 60 95 3) 150 150 150 1) Maximum temperature range see nameplate 2) For sensors with type of protection Ex na nc applies: T m = 95 C 3) For sensors with type of protection Ex na nc applies: T m = 130 C 4) For sensors with type of protection Ex na nc applies: T m = 195 C 5) Cryogenic temperature version: T m = -196 150 C Promass S T m 8 50 150 80 1) 115 2) 150 150 150 60 115 2) 150 150 150 15 50 50 150 60 1) 95 2) 150 150 150 60 95 2) 150 150 150 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 130 C 14 Endress+Hauser

Proline Promass 300 XA01507D Promass X T m 350 50 180 60 1) 95 2) 160 3) 180 180 55 95 2) 160 3) 180 180 60 (95 2) ) (160 3) ) (180) (180) 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 130 C 3) For sensors with type of protection Ex na nc applies: T m = 180 C Promass A With thermal insulation according to Endress+Hauser specifications For information on the thermal insulation of the device, see the "Thermal insulation" section of the "Technical Information" document T m 1 4 50 205 90 1) 130 170 2) 205 205 55 (130) (170 2) ) (205) (205) 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 195 C Promass E T m 8 50 50 150 80 1) 115 2) 150 150 150 55 (115 2) ) (140 3) ) (150) (150) 80 50 150 60 1) 95 2) 140 3) 150 150 55 (95 2) ) (140 3) ) (150) (150) 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 130 C 3) For sensors with type of protection Ex na nc applies: T m = 150 C Endress+Hauser 15

XA01507D Proline Promass 300 Promass F 1) T m 08 15 50 150 2) 80 3) 115 4) 150 150 150 55 (115 4) ) (150) (150) (150) 50 240 80 3) 115 4) 170 5) 240 240 55 (115 4) ) (170 5) ) (240) (240) 25 80 50 150 2) 60 3) 95 4) 150 150 150 55 (95 4) ) (160 5) ) (240) (240) 50 240 60 3) 95 4) 160 5) 240 240 55 (95 4) ) (160 5) ) (240) (240) 50 350 85 3) 120 4) 185 5) 280 6) 350 60 120 4) 185 5) 280 6) 350 100 250 50 150 2) 60 3) 95 4) 150 150 150 55 (95 4) ) (160 5) ) (240) (240) 50 240 60 3) 95 4) 160 5) 240 240 55 (95 4) ) (160 5) ) (240) (240) 1) Maximum temperature range see nameplate 2) Cryogenic temperature version: T m = -196 150 C 3) For sensors with type of protection Ex na nc applies: T m = 95 C 4) For sensors with type of protection Ex na nc applies: T m = 130 C 5) For sensors with type of protection Ex na nc applies: T m = 195 C 6) For sensors with type of protection Ex na nc applies: T m = 290 C Promass H T m 8 50 150 1) 80 2) 115 3) 150 150 150 55 (115 3) ) (150) (150) (150) 8 50 205 4) 80 2) 115 3) 165 5) 205 205 55 (115 3) ) (165 5) ) (205) (205) 15 50 50 150 1) 60 2) 95 3) 130 6) 150 150 55 (95 3) ) (130) (150) (150) 16 Endress+Hauser

Proline Promass 300 XA01507D T m 15 50 50 205 4) 60 2) 95 3) 130 5) 205 205 55 (95) (130) (205) (205) 1) Measuring tube material tantalum 2) For sensors with type of protection Ex na nc applies: T m = 95 C 3) For sensors with type of protection Ex na nc applies: T m = 130 C 4) Measuring tube material zirconium 5) For sensors with type of protection Ex na nc applies: T m = 195 C 6) For sensors with type of protection Ex na nc applies: T m = 150 C Promass I T m 8 80 50 150 60 1) 95 2) 150 150 150 60 (95 2) ) (150) (150) (150) 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 130 C Promass O T m 80 250 50 205 60 1) 95 2) 160 3) 205 205 55 (95 2) ) (160 3) ) (205) (205) 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 130 C 3) For sensors with type of protection Ex na nc applies: T m = 195 C Promass P 1) T m 8 50 150 80 2) 115 3) 150 150 150 55 (115) (150) (150) (150) 50 205 80 2) 115 3) 170 4) 205 205 Endress+Hauser 17

XA01507D Proline Promass 300 1) T m 55 (115 3) ) (170 4) ) (205) (205) 15 50 50 150 60 2) 95 3) 150 150 150 55 95 3) 150 150 150 60 (95 3) ) (150) (150) (150) 50 205 60 2) 95 3) 160 4) 205 205 55 95 3) 160 4) 205 205 60 (95 3) ) (160 4) ) (205) (205) 1) Maximum temperature range see nameplate 2) For sensors with type of protection Ex na nc applies: T m = 95 C 3) For sensors with type of protection Ex na nc applies: T m = 130 C 4) For sensors with type of protection Ex na nc applies: T m = 195 C Promass Q 1) T m 25 100 50 205 60 2) 95 3) 160 4) 205 205 55 (40) (95) (160) (205) (205) 25 100 50 150 5) 60 2) 95 3) 150 150 150 55 (40) (95) (150) (150) (150) 1) Maximum temperature range see nameplate 2) For sensors with type of protection Ex na nc applies: T m = 95 C 3) For sensors with type of protection Ex na nc applies: T m = 130 C 4) For sensors with type of protection Ex na nc applies: T m = 195 C 5) Cryogenic temperature version: T m = -196 150 C Promass S T m 8 50 150 80 1) 115 2) 150 150 150 55 (115) (150) (150) (150) 15 50 50 150 60 1) 95 2) 150 150 150 18 Endress+Hauser

Proline Promass 300 XA01507D T m 55 95 2) 150 150 150 60 (95 2) ) (150) (150) (150) 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 130 C Promass X T m 350 50 180 60 1) 95 2) 160 3) 180 180 55 (95 2) ) (160 3) ) (180) (180) 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 130 C 3) For sensors with type of protection Ex na nc applies: T m = 180 C With thermal insulation without Endress+Hauser specifications 1 A B 1 Position of the reference point for temperature measurement A Standard version B Extended temperature version, cryogenic temperature version, hightemperature version 1 Reference point A0031198 Endress+Hauser 19

XA01507D Proline Promass 300 T m 63 72 75 77 77 20 Endress+Hauser

Proline Promass 300 XA01507D Connection data: Signal circuits The following tables contain specifications which are dependent on the transmitter type and its input and output assignment. Compare the following specifications with those on the nameplate of the transmitter. Terminal assignment Transmitter: supply voltage, input/outputs HART Supply voltage Input/output 1 Input/output 2 Input/output 3 1 (+) 2 ( ) 26 (+) 27 ( ) 24 (+) 25 ( ) 22 (+) 23 ( ) Device-specific terminal assignment: adhesive label in terminal cover. FOUNDATION Fieldbus Supply voltage Input/output 1 Input/output 2 Input/output 3 1 (+) 2 ( ) 26 (A) 27 (B) 24 (+) 25 ( ) 22 (+) 23 ( ) Device-specific terminal assignment: adhesive label in terminal cover. PROFIBUS PA Supply voltage Input/output 1 Input/output 2 Input/output 3 1 (+) 2 ( ) 26 (B) 27 (A) 24 (+) 25 ( ) 22 (+) 23 ( ) Device-specific terminal assignment: adhesive label in terminal cover. Modbus RS485 Supply voltage Input/output 1 Input/output 2 Input/output 3 1 (+) 2 ( ) 26 (B) 27 (A) 24 (+) 25 ( ) 22 (+) 23 ( ) Device-specific terminal assignment: adhesive label in terminal cover. Endress+Hauser 21

XA01507D Proline Promass 300 Remote display and operating module DKX001 1 Vcc Gnd 81 82 A 83 B 84 2 81 82 83 84 3 Vcc Gnd A B A0027518 1 Remote display and operating module DKX001 2 Connecting cable 3 Measuring device Safety-related values Order code for "Output; input 1" Option BA Output type Current output 4 to 20 ma HART U N = 30 V U M = 250 V Safety-related values "Output; input 1" 26 (+) 27 ( ) Option GA PROFIBUS PA U N = 32 V U M = 250 V Option MA Modbus RS485 U N = 30 V U M = 250 V Option SA FOUNDATION Fieldbus U N = 32 V U M = 250 V Order code for "Output; input 2"; "Output; input 3" Option B Option D Output type Current output 4 to 20 ma User configurable input/output Safety-related values Output; input 2 Output; input 3 24 (+) 25 ( ) 22 (+) 23 ( ) U N = 30 V U M = 250 V U N = 30 V U M = 250 V 22 Endress+Hauser

Proline Promass 300 XA01507D Order code for "Output; input 2"; "Output; input 3" Option E Output type Pulse/frequency/ switch output Safety-related values Output; input 2 Output; input 3 24 (+) 25 ( ) 22 (+) 23 ( ) U N = 30 V U M = 250 V Option F Double pulse output U N = 30 V U M = 250 V Option H Relay output U N = 30 V I N = 100 ma DC/500 ma AC U M = 250 V Option I Current input 4 to 20 ma U N = 30 V U M = 250 V Option J Status input U N = 30 V U M = 250 V Intrinsically safe or NIFW values Order code for "Output; input 1" Output type Intrinsically safe or NIFW values "Output; input 1" 26 (+) 27 ( ) Option HA PROFIBUS PA Ex i AEx ic, Ex ic, NIFW U i = 32 V l i = 570 ma P i = 8.5 W L i = 10 µh C i = 5 nf Option TA FOUNDATION Fieldbus Ex i AEx ic, Ex ic, NIFW U i = 32 V l i = 570 ma P i = 8.5 W L i = 10 µh C i = 5 nf Endress+Hauser 23

XA01507D Proline Promass 300 Order code for "Output; input 2"; "Output; input 3" Output type Intrinsically safe or NIFW values Output; input 2 Output; input 3 24 (+) 25 ( ) 22 (+) 23 ( ) Option C Current output 4-20 ma Ex i U i = 30 V l i = 100 ma P i = 1.25 W L i = 0 C i = 0 Option G Pulse/frequency/ switch output Ex i U i = 30 V l i = 100 ma P i = 1.25 W L i = 0 C i = 0 Remote display DKX001 Basic specification, position 1, 2 Approval Terminal assignment Basic specification, position 8 Display; Operation Option O Option CS, CZ 81, 82, 83, 84 U n = 3.3 V I n = 150 ma 24 Endress+Hauser

www.addresses.endress.com