DATA TRANSMISSION CABLES

Similar documents
COPPER + LWL RAW CABLES

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

NETWORK CONNECTIVITY SYSTEMS

Information technology. Generic cabling systems, General requirements

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION BUILDING MANAGEMENT SYSTEMS

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

UNIRAIL D RS485 and BUS cables

Instrumentation Cable PLTC/ITC and TC Types

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

DB EN valid from: Application SERVO LK SMS FX8PLUS SIGNAL

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

MULTIMEDIA CABLE H6091ZHB

Ship and Offhsore. Approved cables for ship- and offshoreindustry

CUSTOM DESIGN COAXIAL CABLES BY SICAB

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

Content. - DDF Frame Pair Screen Cable Pair Screen Cable

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

CAT 5e UTP Cable: NETSET BOX [305m], indoor

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

Selection table for flat & ribbon cables

Copyright June Nexans

Detailed Specifications & Technical Data

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description

Filled Solid ALPETH Cable

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

Detailed Specifications & Technical Data

List Price w.e.f. 02nd January, 2018

Detailed Specifications & Technical Data

CIR (Crush & Impact Resistant) VFD Power Cable

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

Detailed Specifications & Technical Data

16-2-C Series. Specification Table. Page <1> 19/06/10 V1.0. : Varies with colour and packing.

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Contents. Category7 SSTP Solid Indoor Cable - Page 03

SBCA Industry Standards Subcommittee. Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations

Cables for Data Transmission in Industrial Automation. Fieldbus Cables Copper Cables Fibre Optic Cables

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

Category 6 UTP EuroClass C ca Cables

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

Instrumentation Cables

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

Coaxial Cables Coax Serie. HF Steckverbinder für Mobilfunk-Anwendungen. in Bulk Rings or on Cable Drums

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

Coaxial Cables. Coaxial Cables. & Addison.

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

RG58 Coaxial Cable: 2) Approval:

- Characteristic impedance of cabling links is characterised by Return Loss

LTE high-performance coaxial cables (RG replacement)

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers)

Communication, Control, and Industrial Cable

FOR INTERCONNECT AND CROSS-CONNECT APPLICATIONS

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

Cables for data transmission in industrial automation

Kerman & Kavian Cable Industries ( KCI )

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

New Product Bulletin. Belden Digital Audio Cable. Belden Brilliance AES/EBU

WIRE&CABLE FILS&CÂBLES S I N C E

ABOUT US ABOUT US 1 CRANE CABLES

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

Detailed Specifications & Technical Data

* Peaks of 1.3mm MAX allowed only in a rate of 2% or less

Photo: HELUKABEL. Motor, Servo & Feedback Cables D 1

Transmission Media. Two main groups:

Motor, Servo & Feedback Cables

Medium Voltage Power Cables

Servo Cable Selection

Product information. Marine, Oil & Gas.

Cabling systems for LAN Office, LAN Home, LAN Industry, Access Networks, MAN, WAN and SAN. 10 GBit. ELine, MegaLine, FLine, GigaLine

Amphenol Cable. Features Allows for mass termination Up to 64 conductors

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

Connection technology for wireless communication systems

The Quality Connection. Flex Flexible Control Cable

Nexans Industrial Solutions PRODUCT CATALOG

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

EXCELLENT ELECTRICAL PERFORMANCES

Fireproof Cables (Fire Resistant LSOH Sheathed Cables) КИФнг(A)-HF for RS485

INDUSTRIAL DATA LAND. The best solution for the industrial automation.

ECOFLEX 10 Characteristics Diameter 10,2 mm. ECOFLEX 15 Characteristics Diameter 14,6 mm. AIRCOM PLUS Characteristics Diameter 10,3 mm

CABLE.

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED

Optical Systems Contents

H155A02. Product Description. Product Specifications. Technical Specifications. Application. Bend Radius. CCB-Sub-Crush Resistance.

SAC-5P- 1,5-PUR/M12FS SH

To keep your family safe and protected V-Guard Wires & Cables

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

Cable Type 125. CAI Certification Specification

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

Jumper cable. Feeder cable + connector. Cable clamp. Grounding kit

Detailed Specifications & Technical Data

Transcription:

DATA TRANSMISSION CABLES www.demes.com UTP 4x2x24 AWG Cat 5e 1- Conductor Solid copper wire 2- Insulation PE (ring coded) insulation 3- Cable core Pairs twisted in layers 4- Outer sheath PVC outer sheath (Ral-7001) 4 3 2 1 These connection cables are used in telecommunication networks for transmission of either analog or digital signals. Maximum working transmission speed 100 Mbit/sn. Solid conductor of bare copper wire (0.51 mm), PE insulation. Cores twisted in pairs, four pairs twisted in layers. PVC-based compound of outer sheath, gray. TECHNICAL CHARACTERISTICS Impedance 100Ω± %15 in range of 1-100 MHz Mutual Capacity Max. 56 nf/km (at 1 khz) Conductor Resistance Max. 94Ω/km Insulation Resistance Min. 5000 MΩ km Working Temperature -30 C to + 70 C Working Voltage 250 volt Test Voltage 1200 volt Min. Bending Radius 25 mm Frequency (MHz) Return loss (SRL) (db) Attenuations (db/100 m) Next (Near-End crosstalk) (db) 1.00 23 1.9 62 4.00 23 4.0 53 8.00 23 5.7 48 10.00 23 6.3 47 16.00 23 8.0 44 20.00 23 9.1 42 25.00 22 10.3 41 31.25 21 11.5 39 62.50 18 16.0 35 100.00 16 21.0 32 1

DATA TRANSMISSION CABLES S/UTP 4x2x24 AWG Cat 5e F/UTP 4x2x24 AWG Cat 5e 1- Conductor Solid copper wire 2- Insulation PE (ring coded) insulation 3- Cable Base Pairs twisted in layers 4- Wrapping Tape PES tape 5- Drain wire Tinned copper wire 6- Screen ALPES tape 7- Outer Sheath PVC outer sheath, gray (Ral-7001) 7 6 4 5 3 2 1 These connection cables are used in telecommunication networks for transmission of either analog or digital signals. Maximum working transmission speed 100 Mbit/sn. Solid conductor of bare copper wire (0.51 mm), PE insulation. Cores twisted in pairs, four pairs twisted in layers, over the base polyster foil wrapping tape, tinned copper drain wire, over the cable static screen of plastic coated aluminum foil (AL-PES). PVC-based compound of outer sheath, gray. TECHNICAL CHARACTERISTICS Impedance 100Ω± %15 in range of 1-100 MHz Mutual Capacity Max. 56 nf/km (at 1 khz) Conductor Resistance Max. 94Ω/km Insulation Resistance Min. 5000 MΩ km Working Temperature -30 C to + 70 C Working Voltage 250 volt Test Voltage 1200 volt Min. Bending Radius 25 mm Frequency (MHz) Return loss (SRL) (db) Attenuations (db/100 m) Next (Near-End crosstalk) (db) 1.00 23 1.9 62 4.00 23 4.0 53 8.00 23 5.7 48 10.00 23 6.3 47 16.00 23 8.0 44 20.00 23 9.1 42 25.00 22 10.3 41 31.25 21 11.5 39 62.50 18 16.0 35 100.00 16 21.0 32 2

www.demes.com STP 4x2x24 AWG Cat 5e F/FTP 4x2x24 AWG Cat 5e 1- Conductor Solid copper wire 2- Insulation PE (ring coded) insulation 3- Pairs Screened twisted pairs 4- Cable Base Pairs twisted in layers 5- Wrapping Tape PES tape 6- Drain Tinned copper wire 7- Screen AL-PES-AL tape 8- Outer Sheath PVC outer sheath, gray (RAL-7001) 8 7 5 6 4 3 2 1 These connection cable are used in telecommunication networks for transmission of either analog or digital signals. Maximum working transmission speed 100 Mbit/sn. Solid conductor of bare copper wire (0.51 mm), PE insulation. Cores twisted in pairs, four individual screened pairs twisted in layers. Over the screened pairs twisted in layers; polyester tape, tinned copper wire and ALPESAL tape applied. PVC-based compound of outer sheath, gray. TECHNICAL CHARACTERISTICS Impedance 100Ω± %15 in range of 1-100 MHz Mutual Capacity Max. 56 nf/km (at 1 khz) Conductor Resistance Max. 94Ω/km Insulation Resistance Min. 5000 MΩ km Working Temperature -30 C to + 70 C Working Voltage 250 volt Test Voltage 1200 volt Min. Bending Radius 25 mm Frequency (MHz) Return loss (SRL) (db) Attenuations (db/100 m) Next (Near-End crosstalk) (db) 1.00 23 1.9 62 4.00 23 4.0 53 8.00 23 5.7 48 10.00 23 6.3 47 16.00 23 8.0 44 20.00 23 9.1 42 25.00 22 10.3 41 31.25 21 11.5 39 62.50 18 16.0 35 100.00 16 21.0 32 3

DATA TRANSMISSION CABLES C/STP 4x2x24 AWG Cat 5e S/FTP 4x2x24 AWG Cat 5e 1- Conductor Solid copper wire 2- Insulation PE (ring coded) insulation 3- Pairs Cores twisted in pairs 4- Drain Tinned solid copper wire 5-1 st Screen AL-PES-AL tape 6- Cable Base Four pairs twisted in layers 7-2 nd Screen Tinned copper wire braiding 8- Outer Sheath PVC outer sheath, gray (Ral-7001) 8 7 6 5 4 3 2 1 These connection cables are used in telecommunication networks for transmission of either analog or digital signals. Maximum working transmission speed 100 Mbit/sn. Solid conductor of bare copper wire (0.51 mm), PE insulation. Cores twisted in pairs and drain tinned copper wire covered with plastic coated aluminum foil (AL-PES-AL). Four pairs twisted in layers. Screen braiding of tinned copper wire. Outer sheath of PVC-based compound, gray. TECHNICAL CHARACTERISTICS Impedance 100 Ω± %15 in range of 1-100 MHz Mutual Capacity Max. 56 nf/km (at 1 khz) Conductor Resistance Max. 94Ω/km Insulation Resistance Min. 5000 MΩ km Working Temperature -30 C to + 70 C Working Voltage 250 volt Test Voltage 1200 volt Min. Bending Radius 25 mm Frequency (MHz) Return loss (SRL) (db) Attenuations (db/100 m) Next (Near-End crosstalk) (db) 1.00 23 1.9 62 4.00 23 4.0 53 8.00 23 5.7 48 10.00 23 6.3 47 16.00 23 8.0 44 20.00 23 9.1 42 25.00 22 10.3 41 31.25 21 11.5 39 62.50 18 16.0 35 100.00 16 21.0 32 4

www.demes.com U/UTP 4x2x26 AWG Cat 5e F/UTP 4x2x26 AWG Cat 5e 1- Conductor Stranded copper wire (7x0.16 mm) 2- Insulation PE (ring coded) insulation 3- Cable Core Pairs twisted in layers 4- Outer Sheath PVC outer sheath, gray (Ral-7001) 4 3 2 1 These connection cables are used in telecommunication networks for transmission of either analog or digital signals. Maximum working transmission speed 100 Mbit/sn. Fine stranded copper wire (7x0.16 mm), PE insulation. Cores twisted in pairs, four pairs twisted in layers. PVCbased compound of outer sheath, gray. TECHNICAL CHARACTERISTICS Impedance 100 Ω±%15 in range of 1-100 MHz Mutual Capacity Max. 56 nf/km (at 1 khz) Conductor Resistance Max. 138.Ω/km Insulation Resistance Min. 5000 MΩ km Working Temperature -30 C to + 70 C Working Voltage 250 volt Test Voltage 500 volt Min. Bending Radius 25 mm Frequency (MHz) Return loss (SRL) (db) Attenuations (db/100 m) Next (Near-End crosstalk) (db) 1.0 23 3.2 62 4.0 23 6.5 53 8.0 23 8.0 48 10.0 23 9.9 47 16.0 23 12.3 44 20.0 23 13.8 42 25.0 22 15.9 41 31.25 21 17.9 39 62.50 18 25.7 35 100.0 16 33.0 32 5

DATA TRANSMISSION CABLES FS/UTP 4x2x24 AWG Cat 5e F/UTP 4x2x24 AWG Cat 5e 1- Conductor Stranded copper wire (7x0.20 mm) 2- Insulation PE (ring coded) insulation 3- Cable Core Pairs twisted in layers 4- Wrapping Tape Polyster tape 5- Drain Multi stranded tinned copper wire 6- Screen AL-PES tape 7- Outer Sheath PVC outer sheath, gray (Ral-7001) 7 6 4 5 3 2 1 These connection cable are used in telecommunication networks for transmission of either analog or digital signals. Special flexible design for patch panels. Maximum working transmission speed 100 Mbit. Fine stranded cooper wire (7x0.20mm) conductor, solid PE insulation. Cores twisted in pairs, four pairs twisted in layers. Polyster wrapping tape. Multi stranded tinned copper wire drain wire. Screen of plastic coated aluminum foil. PVC-based compound of outer sheath, gray. (RAL 7001) TECHNICAL CHARACTERISTICS Impedance 100 Ω±%15 in range of 1-100 MHz Mutual Capacity Max. 56 nf/km (at 1 khz) Conductor Resistance Max. 88.Ω/km Insulation Resistance Min. 5000 MΩ km Working Temperature -30 C to + 70 C Working Voltage 250 volt Test Voltage 1200 volt Min. Bending Radius 25 mm Frequency (MHz) Return loss (SRL) (db) Attenuations (db/100 m) Next (Near-End crosstalk) (db) 1.0 23.0 2.2 62 4.0 23.0 4.8 53 8.0 23.0 6.4 48 10.0 23.0 7.5 47 16.0 23.0 8.7 44 20.0 23.0 10.2 42 25.0 22.0 12.0 41 31.25 21.0 13.9 39 62.50 18.0 19.7 35 100.0 16.0 24.0 32 6

www.demes.com FC/UTP 4x2x26 AWG Cat 5e S/UTP 4x2x26 AWG Cat 5e 1- Conductor Stranded copper wire (7x0.16 mm) 2- Insulation PE (ring coded) insulation 3- Cable Core Pairs twisted in layers 4- Wrapping Tape Polyster tape 5- Screen Tinned copper wire braiding 6- Outer Sheath PVC outer sheath, gray (Ral-7001) 6 5 4 3 2 1 These connection cables are used in telecommunication networks for transmission of either analog or digital signals. Special flexible design for patch panels. Maximum working transmission speed 100 Mbit. Fine stranded copper wire (7x0.20 mm) conductor, solid PE insulation. Cores twisted in pairs, four pairs twisted in layers. Polyster wrapping tape. Screen braiding of tinned copper wire. Outer sheath of PVC-based compound, gray (RAL 7001). TECHNICAL CHARACTERISTICS Impedance 100 Ω±%15 in range of 1-100 MHz Mutual Capacity Max. 56 nf/km (at 1 khz) Conductor Resistance Max. 138.Ω/km Insulation Resistance Min. 5000 MΩ km Working Temperature -30 C to + 70 C Working Voltage 250 volt Test Voltage 1200 volt Min. Bending Radius 26 mm Frequency (MHz) Return loss (SRL) (db) Attenuations (db/100 m) Next (Near-End c rosstalk) (db) 1.0 23.0 3.2 62 4.0 23.0 6.5 53 8.0 23.0 8.0 48 10.0 23.0 9.9 47 16.0 23.0 12.3 44 20.0 23.0 13.8 42 25.0 22.0 15.9 41 31.25 21.0 17.9 39 62.50 18.0 25.7 35 100.0 16.0 33.0 32 7

DATA TRANSMISSION CABLES UTP 4x2x24 AWG Cat 6 1- Conductor Solid copper wire (0.51 mm) 2- Insulation Polyolefin (ring coded) 3- Cable Core Pairs twisted in layers 4- Outer Sheath PVC-based, gray (Ral-7001, Ral-7032) 4 3 2 1 These connection cables are used in telecommunication networks for transmission of either analog or digital signals. Maximum working transmission speed 125 Mbit/sn. Solid conductor of bare copper wire (0.51 mm), Polyelefin insulation. Cores twisted in pairs, four screened pairs twisted in layers. PVC-based compound of outer sheath, gray. TECHNICAL CHARACTERISTICS Impedance 100 Ω±%15 in range of 1-100 MHz 100 Ω±%22 in range of 125 MHz Efective Capacity Max. 56 nf/km (at 1 khz) Conductor Resistance Max. 94.Ω/km Insulation Resistance Min. 5000 MW.km Temperature Range -30 C to + 70 C Working Voltage 250 volt Test Voltage 1200 volt Min. Bending Radius 25 mm Frequency (MHz) Return loss (SRL) (db) Attenuations (db/100 m) Next (Near-End crosstalk) (db) 1.0 23 2.1 72 4.0 23 3.8 63 8.0 24.5 5.8 58 10.0 25 6.0 57 16.0 25 7.6 54 20.0 25 8.5 53 25.0 24.3 10.3 51 31.25 23.6 10.8 50 62.5 21.5 15.5 45 100.0 20.1 19.9 42 125 19.4 22.5 41 200 18 29.2 38 250 17.3 33.0 36 8

www.demes.com RS 232/00 1- Conductor Fine stranded tinned annealed copper wire 2- Insulation PVC insulation 3- Wrapping Tape PES tape 4- Drain Stranded tinned copper wire 5- Screen Tinned copper wire braiding 6- Outer Sheath PVC outer sheath, gray (Ral-7032) 6 5 3 4 2 1 These connection cables are used in telecommunication networks and electronic control systems for signal transmission. Fine stranded tinned annealed copper wire, semi rigid PVC-based insulation. Cores twisted in pairs, pairs twisted in layers, polyster wrapping tape with drain stranded annealed tinned copper wire. Screen braiding of tinned copper wire. Outer sheath of PVC- based compound, gray (RAL-7032). TECHNICAL CHARACTERISTICS Mutual Capacity AWG 22.24 : max. 100 nf/km AWG 20 : max. 120 nf/km Working Temperature -30 C to + 70 C Insulation Resistance 50 MΩ Working Voltage 250 volt Test Voltage 1200 volt Min. Bending Radius 15xCable diameter Number of cores and Approx. outside diameter (mm) Copper factorial (per km) Approx. weigth (kg/km) cross-section (mm 2 ) DAT-232/00 AWG 24 2x2x0.22 6.4 29.1 67.4 3x2x0.22 6.7 34.2 76.5 4x2x0.22 7.2 42.6 89.9 5x2x0.22 8.2 47.2 109.5 6x2x0.22 8.8 55.2 123.4 7x2x0.22 8.8 59.4 130.4 8x2x0.22 9.3 64.2 140.5 9x2x0.22 10.3 72.4 156.4 10x2x0.22 10.4 77.5 165.0 12x2x0.22 10.8 87.8 183.0 14x2x0.22 11.5 98.9 203.0 16x2x0.22 12.1 109.9 222.7 9

DATA TRANSMISSION CABLES RS 232/00 Number of cores and Approx. outside diameter (mm) Copper factorial (per km) Approx. weigth (kg/km) cross-section (mm 2 ) DAT-232/00 AWG 24 18x2x0.22 12.6 122.8 244.2 20x2x0.22 13.2 133.6 263.3 25x2x0.22 14.6 178.1 329.2 DAT-232/00 AWG 22 2x2x0.34 7.5 39.2 77.1 3x2x0.34 7.8 47.7 91.3 4x2x0.34 8.5 57.1 107.7 5x2x0.34 9.2 67.0 125.1 6x2x0.34 10.1 76.1 146.5 7x2x0.34 10.1 83.7 158.1 8x2x0.34 10.7 92.8 174.3 9x2x0.34 12.3 104.3 207.3 10x2x0.34 12.4 111.8 219.7 12x2x0.34 13.0 127.3 246.5 14x2x0.34 14.0 159.5 292.7 16x2x0.34 14.7 177.1 322.9 18x2x0.34 15.4 194.8 352.9 20x2x0.34 16.0 211.5 381.6 25x2x0.34 17.5 253.9 453.4 DAT-232/00 AWG 20 2x2x0.5 8.8 52.7 102.0 3x2x0.5 9.3 64.6 122.8 4x2x0.5 10.1 78.4 147.2 5x2x0.5 11.0 92.2 172.1 6x2x0.5 12.1 106.2 202.9 7x2x0.5 12.1 116.4 219.8 8x2x0.5 13.1 144.6 259.6 9x2x0.5 15.0 162.9 306.3 10x2x0.5 15.1 174.0 325.3 12x2x0.5 15.8 198.5 367.3 14x2x0.5 16.8 224.4 412.8 16x2x0.5 17.7 249.7 457.2 18x2x0.5 18.6 274.7 501.1 20x2x0.5 19.4 299.7 544.6 25x2x0.5 21.3 361.9 652.2 10

www.demes.com RS 422/00 1- Conductor Stranded tinned copper wire 2- Insulation PE insulation 3- Wrapping Tape Polyster tape 4- Screen AL-PES tape 5- Drain Stranded tinned copper wire 6- Screen Tinned copper wire braiding 7- Outer Sheath PVC outer sheath, gray (Ral-7032) 7 6 4 3 5 2 1 These connection cables are used in telecommunication networks and electronic control systems for signal transmission. Fine stranded tinned annealed copper wire, PE core insulation. Cores twisted in pairs, pairs twisted in layers, polyster wrapping tape. Screen of aluminum coated polyester foil. Screen braiding of tinned copper wire with tinned copper wire drain. Outer sheath of PVC- based compound, gray. (RAL-7032) TECHNICAL CHARACTERISTICS Mutual Capacity max. 50 nf/km Working Temperature -30 C to + 80 C Insulation Resistance 5 GΩkm Working Voltage 250 volt Test Voltage 1200 volt Min. Bending Radius 15xCable diameter Number of cores and Approx. outside diameter (mm) Copper factorial (per km) Approx. weigth (kg/km) cross-section (mm 2 ) DAT-422/00 AWG 24 2x2x0.22 7.0 30 72 3x2x0.22 7.4 35 81 4x2x0.22 7.9 44 94 5x2x0.22 8.6 51 107 6x2x0.22 9.5 57 124 7x2x0.22 9.5 62 130 8x2x0.22 10.0 70 143 10x2x0.22 11.2 81 164 15x2x0.22 12.9 121 222 20x2x0.22 14.4 146 266 11

DATA TRANSMISSION CABLES RS 422/00 Number of cores and Approx. outside diameter (mm) Copper factorial (per km) Approx. weigth (kg/km) cross-section (mm 2 ) DAT-422/00 AWG 22 2x2x0.34 8.2 44 85 3x2x0.34 8.6 51 98 4x2x0.34 9.4 59 113 5x2x0.34 10.2 72 133 6x2x0.34 11.2 79 154 7x2x0.34 11.2 86 163 8x2x0.34 11.9 99 183 10x2x0.34 13.9 130 243 15x2x0.34 16.1 191 334 20x2x0.34 18.0 235 407 DAT-422/00 AWG 20 2x2x0.5 8.6 53.4 99 3x2x0.5 9.1 63.9 116 4x2x0.5 9.9 77.6 138 5x2x0.5 10.8 91.7 161 6x2x0.5 12.1 120.1 205 7x2x0.5 12.1 130.7 220 8x2x0.5 12.8 143.0 241 10x2x0.5 14.8 173.8 304 12

www.demes.com TWINAXIAL 105 Ω 1- Conductor Solid electrolitic copper wire 2- Insulation Foam PE 3- Paired cores Two cores twisted in pairs 4-2nd Screen Braiding of tinned copper wire 5-3rd Screen AL-PES-AL 6-4th Screen Braiding of tinned copper wire 7- Outer Sheath PVC compound, gray 6 5 4 3 2 1 These LAN data transmission cables are used for ethernet networks. Can be used to link main units, Data transmission speed is 10 mbit/s. Solid electrolitic copper wire, Foam PE insulation. Screen of aluminum coated polyester foil (AL-PES). Screen braiding of tinned copper wire. Screen of aluminum coated polyester foil; two sided (AL-PES-AL). Screen braiding of tinned copper wire. Outer sheath of PVC compound, yellow. TECHNICAL CHARACTERISTICS Impedance Efective capacity Conductor resistance Insulation resistance Temperature range Working voltage Test voltage Min. bending radius 50 ± 2Ω max. 85 nf/m max. 4.7 Ω/km min. 5.000 MΩ km -30 C to +70 C max. 2.5 V max. 5.0 V 200 mm Frequency (MHz) 100 200 400 600 800 Attenuation (db/100 m) 5.5 7.7 11 14.4 16.8 13

DATA TRANSMISSION CABLES RG-62 A/U INDOOR 1- Conductor Copper clad steel wire 2- Insulation Semi-solid PE insulation 3- Screen Annealed copper wire braiding 4- Outer sheath PVC outer sheath, black 4 3 2 1 These data transmission cables are used IBM networks as data transmission cable. No outdoor use. Copper clad, steel wire, semi-solid PE-air spaced-insulation. Screen braiding of electrolitic annealed copper wire. Outer sheath of PVC compound, black. TECHNICAL CHARACTERISTICS Impedance Mutual capacity Conductor resistance Insulation resistance Working temperature Working voltage Test voltage Min. bending radius 93 ± 5Ω max. 43 pf/km max. 144 Ω/km (29ºC) min. 2000 MΩ km -40 C to +70 C max. 2.5 kv max. 5.0 kv 5xD mm Frequency (MHz) 100 200 400 600 800 1000 Attenuation (db/100 m) 9 14 18 23 27 29 14

www.demes.com RG-62 A/U OUTDOOR 1- Conductor Copper clad steel wire 2- Insulation Semi-solid PE insulation 3- Screen Annealed copper wire braiding 4- Wrapping tape Polyester tape 5- Outer sheath PVC outer sheath, black 5 3 4 2 1 These data transmission cables are used IBM networks as data transmission cable. Application for outdoor use. Copper clad, steel wire, semi-solid PE-air spaced-insulation. Screen braiding of electrolitic annealed copper wire. Outer sheath of PE compound, black. TECHNICAL CHARACTERISTIC Impedance Mutual capacity Conductor resistance Insulation resistance Working temperature Working voltage Test voltage Min. bending radius 93 ± 5Ω max. 43 pf/km max. 144 Ω/km (29ºC) min. 2000 MΩ km -40 C to +70 C max. 2.5 kv max. 5.0 kv 5xD mm Frequency (MHz) 100 200 400 600 800 1000 Attenuation (db/100 m) 9 14 18 23 27 29 15

DATA TRANSMISSION CABLES RG-59 / U-4 1- Conductor Ø 0.83 mm electrolitic copper wire 2- Insulation Ø 3.90 mm foam polyethylene insulation 3-1 st Screen AL-PES tape 4-2 nd Screen Tinned copper wire braiding 5- Outer sheath PVC outer sheath, Ø 6.0 mm, white 5 4 3 2 1 Used as connection cable in CATV, CCTV and satellite and common antenna TV systems. Electrolitic annealed copper wire conductor. Foam Polyethylene insulation. Screen of plastic coated aluminum foil AL-PES-AL (100% coverage). Screen braiding of tinned copper wire (85% coverage). Outer sheath of PVC compound, white. TECHNICAL CHARACTERISTICS Impedance Mutual capacity Conductor resistance Insulation resistance Working temperature Working voltage Test voltage Min. bending radius 75 ± 3Ω max.61 pf/km max. 144 Ω/km (29ºC) min. 2000 MΩ km -40 C to +70 C max. 1.1 kv 2.5 kv 10xD mm Frequency (MHz) 100 200 450 600 800 1000 Attenuation (db/100 m) 9 13 16 20 28 31 16

www.demes.com TVVF-F2/TVGF 1- Conductor Solid conductor 2- Insulation PVC or halogen-free insulation 3- Wrapping Polyester tape 4- Drain wire Solid tinned copper 5- Screen ALPES tape 6 6- Outer sheath Flame retardant PVC or halogen-free outer sheath 5 3 4 2 1 Flame retardent or halogen free telephone and fire alarm systems cables for interior installations. Solid bare copper conductor, PVC or halogen free insulated, cores twisted in pairs, pairs twisted in layers over the base polyester foil wrapping tape, tinned copper drain wire over the cable static screen of plastic coated aluminum foil (ALPES). temperature range Occasional flexing -5 C to +70 C Fixed installation -30 C to +70 C test voltage 1000 V (AC) bending radius 10xD FIRE PERFORMANCE Flame retardant No flame propagation IEC 60332-1, DIN EN 50265-1/-2-1, VDE 0482 P265-1/2-1 IEC 60332-3-10/-3-24, DIN EN 50266-1/-2-4, VDE 0482 P266-1/-2-4 MATERIAL PROPERTIES FOR HALOGEN FREE Halogen-free IEC 60754-1, VDE 0482 P267-2-1, DIN EN50267-2-1 No corrosive gases IEC 60754-2, VDE 0482 P267-2-2, DIN EN 50267-2-2 Low smoke emission IEC 61034-1/-2, VDE 0482 P268-1/-2, DIN EN 50268-1/-2 17

DATA TRANSMISSION CABLES TVVF-F2/TVGF Number of cores x Approx. outside diameter (mm) Net weight approx.(kg/km) nominal conductor diameter (mm) 1x2x0.6 4.7 28 2x2x0.6 5.4 39 3x2x0.6 5.8 48 4x2x0.6 6.3 58 5x2x0.6 6.8 68 6x2x0.6 7.2 77 8x2x0.6 7.9 95 10x2x0.6 8.5 113 12x2x0.6 9.1 132 14x2x0.6 9.6 149 15x2x0.6 9.8 157 20x2x0.6 11.4 211 1x2x0.8 5.5 37 2x2x0.8 6.5 55 3x2x0.8 7.2 71 4x2x0.8 7.9 88 5x2x0.8 8.5 104 6x2x0.8 9.1 120 8x2x0.8 10.1 150 10x2x0.8 11.0 179 12x2x0.8 11.8 210 14x2x0.8 12.5 238 15x2x0.8 12.9 252 20x2x0.8 14.8 340 18

www.demes.com TWAVB 1- Conductor Solid bare conductor 2- Insulation PE insulation 5 3- Filler Extruded PVC filler 4- Armour 2Galvanized steel tape with drain wire or galvanized steel wires 5- Outer Sheath Flame retardant PVC outer sheath 4 3 2 1 Telephone and signalisation cables, cores twisted in pairs, armoured and flame retardant, for outdoor installations. Solid bare copper conductor, Polyethylene insulated, armoured and flame retardant PVC outer sheathed cables. temperature range Occasional flexing -5 C to +70 C Fixed installation -30 C to +70 C test voltage bending radius 1000 V (AC) 15xD FIRE PERFORMANCE Flame retardant IEC 60332-1, DIN EN 50265-1/-2-1, VDE 0482 P265-1/2-1 Number of cores x Approx. outside diameter (mm) Net weight approx.(kg/km) nominal conductor diameter (mm) 1x4x0.8 12.0 280 4x2x0.8 14.6 400 5x2x0.8 15.3 440 7x2x0.8 16.2 500 10x2x0.8 18.3 606 12x2x0.8 19.3 681 16x2x0.8 20.2 666 19x2x0.8 21.3 737 21x2x0.8 22.0 782 27x2x0.8 24.0 915 30x2x0.8 25.0 980 40x2x0.8 28.3 1375 52x2x0.8 32.2 1740 61x2x0.8 34.1 1930 80x2x0.8 37.6 2316 100x2x0.8 41.0 3705 19

DATA TRANSMISSION CABLES SVV-F2/SVG-F2 1- Conductor Solid bare conductor 2- Insulation PVC or halogen-free insulation 3- Outer Sheath Flame retardant PVC or halogen-free outer sheath 3 2 1 Telephone and signalisation cables, cores laid up concentric layers and flame retardant, for interior installations. Halogen free version is SVG-F2. Solid bare copper conductor, PVC or halogen-free insulated, flame retardant PVC or halogen-free outer sheathed (low smoke) cables. temperature range Occasional flexing -5 C to +70 C Fixed installation -30 C to +70 C test voltage 2500 V (AC) bending radius 15xD FIRE PERFORMANCE Flame retardant No flame propagation IEC 60332-1, DIN EN 50265-1/-2-1, VDE 0482 P265-1/2-1 IEC 60332-3-10/-3-24, DIN EN 50266-1/-2-4, VDE 0482 P266-1/-2-4 MATERIAL PROPERTIES FOR HALOGEN FREE Halogen-free IEC 60754-1, VDE 0482 P267-2-1, DIN EN50267-2-1 No corrosive gases IEC 60754-2, VDE 0482 P267-2-2, DIN EN 50267-2-2 Low smoke emission IEC 61034-1/-2, VDE 0482 P268-1/-2, DIN EN 50268-1/-2 Number of cores x Approx. outside diameter (mm) Net weight approx.(kg/km) nominal conductor diameter (mm) 2x0.8 4.1 21 4x0.8 4.9 37 6x0.8 5.7 51 8x0.8 6.5 68 10x0.8 7.7 91 12x0.8 8.1 108 14x0.8 8.4 122 16x0.8 8.8 136 20x0.8 9.7 164 24x0.8 10.6 193 20

www.demes.com TPVF-F2/TPGF 1- Conductor Solid tinned conductor 2- Insulation PE insulation 3- Pairs Screened twisted pairs 4- Cable Base Pairs twisted in layers 5- Drain Solid tinned copper wire 6- Wrapping Polyester tape 5 7- Outer Sheath Flame retardant PVC or halogen free outer sheath 4 3 2 1 Telephone and signalisation cables, cores twisted in pairs and pairs shielded, flame retardant, for interior installations. Halogen free version is TPGF. Solid tinned copper conductor, Polyethylene insulated, flame retardant PVC or halogen-free (low smoke) outer sheathed cables. temperature range Occasional flexing -5 C to +70 C Fixed installation -30 C to +70 C test voltage 1000 V (AC) bending radius 10xD FIRE PERFORMANCE Flame retardant No flame propagation EC 60332-1, DIN EN 50265-1/-2-1, VDE 0482 P265-1/2-1 IEC 60332-3-10/-3-24, DIN EN 50266-1/-2-4, VDE 0482 P266-1/-2-4 MATERIAL PROPERTIES FOR HALOGEN FREE Halogen-free IEC 60754-1, VDE 0482 P267-2-1, DIN EN50267-2-1 No corrosive gases IEC 60754-2, VDE 0482 P267-2-2, DIN EN 50267-2-2 Low smoke emission IEC 61034-1/-2, VDE 0482 P268-1/-2, DIN EN 50268-1/-2 Number of cores x nominal conductor diameter (mm) Approx. outside diameter (mm) Net weight approx. (kg/km) 1X2X0.6 5.0 26 2X2X0.6 6.0 38 3X2X0.6 6.5 49 4X2X0.6 7.2 59 6X2X0.6 8.3 78 8X2X0.6 9.0 97 10X2X0.6 10.3 126 12X2X0.6 11.0 145 15X2X0.6 12.0 172 20X2X0.6 13.4 217 26X2X0.6 14.8 270 30X2X0.6 15.7 305 50X2X0.6 19.8 495 Number of cores x nominal conductor diameter (mm) Approx. outside diameter (mm) Net weight approx. (kg/km) 1X2X0.8 6.2 42 2X2X0.8 7.4 63 3X2X0.8 8.5 82 4X2X0.8 9.3 101 5X2X0.8 10.0 18 6X2X0.8 10.5 135 8X2X0.8 11.5 169 10X2X0.8 13.0 216 12X2X0.8 14.0 251 15X2X0.8 15.3 302 20X2X0.8 17.3 384 26X2X0.8 19.5 491 30X2X0.8 20.7 555 50X2X0.8 26.2 898 21

DATA TRANSMISSION CABLES VVT-F2/GGT-F2 1- Conductor Solid tinned conductor 2- Insulation PVC or halogen-free insulation 3- Earth Wire PVC or halogen-free insulated solid tinned copper 4- Wrapping Tape Polyester tape 5- Outer Sheath Flame retardant PVC or halogen-free outer sheath 5 4 3 2 1 Telephone and signalisation cables, twisted pairs laid up concentric layers with insulated earth wire and flame retardant, for interior installations. Halogen free version is GGT-F2. Solid tinned copper conductor, PVC or halogen-free insulated, flame retardant PVC or halogen-free outer sheathed (low smoke) cables. temperature range Occasional flexing -5 C to +70 C Fixed installation -30 C to +70 C test voltage 1000 V (AC) bending radius 20xD FIRE PERFORMANCE Flame retardant No flame propagation IEC 60332-1, DIN EN 50265-1/-2-1, VDE 0482 P265-1/2-1 IEC 60332-3-10/-3-24, DIN EN 50266-1/-2-4, VDE 0482 P266-1/-2-4 MATERIAL PROPERTIES FOR HALOGEN FREE Halogen-free IEC 60754-1, VDE 0482 P267-2-1, DIN EN50267-2-1 No corrosive gases IEC 60754-2, VDE 0482 P267-2-2, DIN EN 50267-2-2 Low smoke emission IEC 61034-1/-2, VDE 0482 P268-1/-2, DIN EN 50268-1/-20268-1/-2 22

www.demes.com VVT-F2/GGT-F2 Number of cores x Approx. outside diameter (mm) Net weight approx.(kg/km) nominal contuctor diameter (mm 2 ) 1x2x0.6 5.0 27 2x2x0.6 5.6 37 3x2x0.6 6.2 46 4x2x0.6 6.7 55 6x2x0.6 7.5 72 8x2x0.6 8.2 88 10x2x0.6 8.8 111 12x2x0.6 9.4 127 14x2x0.6 9.9 143 20x2x0.6 11.2 190 26x2x0.6 12.6 245 30x2x0.6 13.2 275 40x2x0.6 15.0 358 50x2x0.6 16.5 435 100x2x0.6 22.5 850 23

DATA TRANSMISSION CABLES LOUD SPEAKER 1- Conductor Fine stranded copper conductor 2- Insulation PVC insulation 2 1 These cables are used in professional broadcasting systems for the transmission of analogue audio signals. The cable consists of stranded multiwire copper conductors and PVC insulated according to BS EN 60228 standard. Type Nominal cable dimension MAX. conductor Weight (Thicknessx width) (mm) resistance (Ohm/km) (kg/km) 2x0.35 1.60x3.2 53.0 5.0 2x0.50 1.90x3.8 39.0 7.5 2x0.75 2.10x4.2 26.0 8.5 2x1.00 2.30x4.6 19.5 9.5 2x1.50 2.55x5.1 13.3 11.0 2x2.50 3.00x6.0 8.0 13.0 2x4.00 3.50x7.1 5.0 16.0 2x6.00 4.30x8.5 3.3 23.0 24

www.demes.com Technical Data British and US Dimensions for Cable and Leads In the US area of influence the dimensions of copper conductors for power and data transmission purposes are usually expressed in AWG Nos*. The corresponding values are: AWG Diameter Cross-section Conductor resistance No. mm mm² Ω/km 500 17.96 253 0.07 350 15.03 177 0.10 250 12.70 127 0.14 4/0 11.68 107.2 0.18 3/0 10.40 85.0 0.23 2/0 9.27 67.5 0.29 1/0 8.25 53.5 0.37 1 7.35 42.4 0.47 2 6.54 33.6 0.57 4 5.19 21.2 0.91 6 4.12 13.3 1.44 8 3.26 8.37 2.36 10 2.59 5.26 3.64 12 2.05 3.31 5.41 14 1.63 2.08 8.79 AWG Diameter Cross-section Conductor resistance No. mm mm² Ω/km 16 1.29 1.33 14.7 18 1.204 0.823 23.0 20 0.813 0.519 34.5 22 0.643 0.324 54.8 24 0.511 0.205 89.2 26 0.405 0.128 149 28 0.320 0.0804 232 30 0.255 0.0507 350 32 0.203 0.0324 578 34 0.160 0.0200 899 36 0.127 0.0127 1426 38 0.102 0.00811 2255 40 0.079 0.00487 3802 42 0.064 0.00317 5842 44 0.051 0.00203 9123 General Dimensions The basic units are in the English gravitational system in the English obsolute system Lenght (ft)-force (lbf=lb)-time (s) Lenght (ft)-mass (lb)-time (s) Lenght Dimensions Cubic Dimensions 1 ml =0.0254 mm 1 cubic inch =16.39 cm³ 1 inch (in, ) =25.4 mm 1 cubic foot = 0.0283 cm³ 1 foot (ft, ) =0.305 m 1 cubic yard = 0.765 mm² 1 yard (yd) = 0.914 m 1 US liquid galon = 3.791 1 chain (ch) =20.1 m 1 pint = 0.4731 1 statue mile = 1.61 km 1 quart = 0.9461 1 nautical mile = 1.835 km 1 brit gallon =4.531 1 statue mile = 1760 yards 1 barrel = 119.21 Area Dimensions 1 circ. mil (CM) = 0.507 10 ³ mm² 1 MCM = 0.5067 mm² 1 square inch (sg. in.) = 645.16 mm² 1 square foot (sq. ft.) = 0.0929 m² 1 square yard = 0.836 m² 1 acre = 0.00405 km² 1 square mile = 2.59 km² 1m2 = 10.764 sq. ft. Mass Units English gravitation system 1 slug = 1 lbs s²/ft English 1 pound = 1 lb 1 slug = 32.174 lb, with 32.174 ft/s² as the standard value of acceleration due to grativity. Conversion to metric units 1 grain = 64.80 mg 1 dram = 1.770 g 1 ounce (oz) = 16 drams = 28.35 g 1 pound (lb) = 16 oz = 453.59 g 1 stone = 14 lbs = 6.35 kg 1 US ton (short ton) = 0.907 t 1 Brit. Ton (long ton) = 1.016 t Units of Force English gravitational systems: pound-force 1 lbf = 1 Lb English absolute systems: poundal 1 pdl = 1 lb ft / s² 1 lbf = 32.174 pdl 9.80665 lb m/s² Conversion to metric units 1 pound-force (lbf) = 0.454 kp 1 Brit. ton force = 1016 kp 1 poundal (pdl) = 0.1383 N 1 lbf = 4.445 N Electrical units per unit lenght Density 1 μf per mile =0.62μF/km 1 lb/ft3 = 16.02 kg/m³ 1 megohm per mile = 1.61 MΩ km 1 decibel per mile = 71.5 m/n/km Weight (specific weight) 1 μf per foot =3.28 pf/m 1 lbf/ft3 = 16.02 kp/m³ 1 decibel per 100 ft =3.77 N/km 1 ohm per 1000 ft = 3.28 Ω /km Copper wire weight per mile 1 ohm per 1000 yd = 1.0936 Ω/km lb/ mile Ø mm 5 0.404 Weight per unit lenght 6.5 0.51 1 lb per foot = 1.488 kg/m 7.5 0.55 1 lb per yard = 0.469 kg/m 10 0.64 1 lb per mile = 0.282 kg/m 20 0.90 40 1.27 Units of Energy 1 horsepower = 0.746 kw (H.P.) 1 brit. therm unit = 0.252 kcal The insulation wall thicknesses are often expressed in n/64 inches, 1.64 inch being rougly equal to 0.4 mm Further dimensions for wire weights and for electrical field strengths: lbf pr. MFeet = 1.488 kg/km 40 V/mil =1.6 kv/mm lbf pr. Mile = 0.282 kg/km 80V/mil = 3.2 kv/mm 100V/mil =4.0 kv/mm 250V/mil =10.0 kv/mm 25

DATA TRANSMISSION CABLES Drum Capacities for Plastic-Insulated Cable in Metres to DIN 46 391 Reel Cables 6 9 12 15 20 25 30 40 50 60 80 61 1113 472 253 179 93 - - - 71 2024 892 468 297 165 - - - 81 2755 1152 643 430 219 151 - - 91-2202 1206 749 402 285 162-101 - - 1540 1000 576 365 220-121 - - - 1991 1139 688 450 249 141 - - - 2479 1352 839 564 327 161 - - - - 2435 1608 1025 549 319 181 - - - - - 1867 1197 640 373 246 201 - - - - - 2522 1583 812 558 296 163 221 - - - - - - 2383 1328 678 566 278 250 - - - - - - - 2892 1107 699 363 TYPE Diameter in mm Width in mm Max. load Weight Drum No Drum size d1 d2 d4 L1 L4 kg kg 061 06 630 315 56 415 315 250 17 071 07 710 355 80 525 400 400 27 081 08 800 400 80 525 400 600 33 091 09 900 450 80 685 560 800 46 101 10 1000 500 80 685 560 900 57 121 12 1250 630 80 870 666 1700 119 141 14 1400 710 80 870 660 2000 154 161 16/8 1600 800 80 1100 844 3000 254 162 16/10 1600 1000 80 1100 835 3000 269 181 18/10 1800 1000 100 1100 835 4000 334 182 18/12 1800 1250 100 1100 825 4000 352 201 20/12 2000 1250 100 1345 1345 5000 524 202 20/14 2000 1400 100 1345 1035 5000 524 221 22/14 2240 1400 125 1475 1140 6000 704 222 22/16 2240 1600 125 1475 1130 6000 738 250 25/14 2500 1600 125 1475 1140 7500 839 251 25/16 2500 1600 125 1475 1130 7500 872 252 25/18 2500 1800 125 1475 1120 7500 909 281 28/18 2800 1800 140 1635 1280 10000 1121 282 28/20 2800 2000 140 1635 1270 10000 1166 26

www.demes.com DIN 47100 Colour Codes The colour code for DEMTRONIK and DEMFLEKS cables is in accordance with DIN 47100/Nov. 1979. In each pair there is always one A-core and one B-core. Upwards of 23 pairs, the identification repeats itself for the first time and from 45 pairs fort he second time. The first is always the basic colour of the core and the second colour is applied in ring-form. No of Pairs Colour a-core Colour b-core No of Pairs Colour a-core Colour b-core 1 white brown 13 white/black brown/black 2 green yellow 14 grey/green yellow/grey 3 grey pink 15 pink/green yellow/pink 4 blue red 16 green/blue yellow/blue 5 black violet 17 green/red yellow/red 6 grey/pink red/blue 18 green/black yellow/ black 7 white/green brown/green 19 grey/blue pink/blue 8 white/yellow yellow/brown 20 grey/red pink/red 9 white/grey grey/brown 21 grey/black pink/black 10 white/pink pink/brown 22 blue/black red/black 11 white/blue brown/blue 23-44 see above see above 12 white/red brown/red 45-66 see above see above DIN 47100 Colour Codes (without colour repetition) The core insulation gives the first colour the second colour is provided by a coloured ringing or band. Where three colours are specified the second and third colours are printed alternately over the basic colour (1 st colour). 1 white 22 brown/ blue 43 blue/black 2 brown 23 white/red 44 red/black 3 green 24 brown/red 45 white/brown/black 4 yellow 25 white/black 46 yellow/green/black 5 grey 26 brown/black 47 grey/pink/black 6 pink 27 grey/green 48 red/blue/black 7 blue 28 yellow/grey 49 white/green/black 8 red 29 pink/green 50 brown/green/black 9 black 30 yellow/pink 51 white/yellow/black 10 violet 31 green/blue 52 yellow/brown/black 11 grey/pink 32 yellow/blue 53 white/grey/black 12 red/blue 33 green/red 54 grey/brown/black 13 white/green 34 yellow/red 55 white/pink/black 14 brown/green 35 green/black 56 pink/brown/black 15 white/yellow 36 yellow/black 57 white/blue/black 16 yellow/brown 37 grey/blue 58 brown/blue/black 17 white/grey 38 pink/blue 59 white/red/black 18 grey/brown 39 grey/red 60 brown/red/black 19 white/pink 40 pink/red 61 black/white 20 pink/brown 41 grey/black 21 white/blue 42 pink/black LAN (Local area network) a-wire pair nr. b-wire white-blue 1 blue white-orange 2 orange white-green 3 green white-brown 4 brown 27

DATA TRANSMISSION CABLES www.demes.com Network Structure Ring Star Bus Mesh Tree CODE DESIGNATION ACCORDING TO VDE ACR Attenuation to Crosstalk Ratio ISDN Integrated Services Digital Network BD Building Entrance Facilities ISO International Organisation for Standardization BFOC B-ISDN Bayonet Fibre Optic Connector Broadband ISDN ITU-T International Telecommunication Union Telecommunication Standardization Bureau (formerly CCITT) BRI Basic Rate ISDN JTC Join Technical Commitee CD Campus Distributor LAN Local Area Network c Speed of light LCL Longitudinal Conversion Loss CISPR International Special Committee on Radio Interference LCTL Longitudinal Conversion Transfer Loss CSMA/CD Carrier Sence Miltiple Access with Collision Detection N/A Not Applicable DCE Data Circuit Terminating Equipment N-BNC N type to BNC Convertor DTE Data Terminal Equipment NEXT Near And Crosstalk DUT Device Under Test OTDR Optical Time Domain Reflectometer EMC Electromagnetic Compability PBX Private Branch Exchange EMI Electromagnetic Interference PDAM Proposed Draft Amendment ER Equipment Room PMD Physical Layer Medium Dependent FD Floor Distributor SC Subsscriber Connector (Optical fibre connector) FDDI Fibre Distributed Data Interface SC-D Duplex SC connector FOIRL Fibre Optic Inter-Repeater Link STI Surface Transfer Impedance FWHM Full Width Half Maximum TC Telecommunications Closet IC Integrated Circuit TDR Time Domain Reflectometer IDC Insulation Displacement Connection TO Telecommunications Outlet IEC International Electrotechnical Commission TP Transition Point CAT2 CAT3 CAT4 CAT5 Frequency Attenuation Next Attenuation Next Attenuation Next Attenuation Next MHz db/100m (max) db (min) db/100m (max) db (min) db/100m (max) db (min) db/100m (max) db (min) 0.772 2.2-2.2 43 1.9 58 1.8 64 1 2.6-2.6 41 2.2 56 2.0 62 4 - - 5.6 32 4.3 47 4.1 53 8 - - 8.5 27 6.2 42 5.8 48 10 - - 9.7 26 6.9 41 6.5 47 16 - - 13.1 23 8.9 38 8.2 44 20 - - - - 10.0 36 9.3 42 25 - - - - - - 10.4 41 31.25 - - - - - - 11.7 39 62.5 - - - - - - 17.0 35 100 - - - - - - 22.0 32 Cable level Data speed 1 ve 2 Ses Frekans Sistemleri 3 10 MBit/s 4 16 MBit/s 5 100 MBit/s 6 300 MBit/s 28

NOTE

NOTE

NOTE

NOTE

DEMES KABLO SAN. TİC. LTD. ŞTİ Kıraç Bel. 3. Bölge Feyzi Çakmak Cd. No: 56 B. Çekmece - İST Telefon: +90 212 689 49 00/Pbx Faks: +90 212 689 00 17 www.demes.com