System Cabling Errors and DC Voltage Measurement Errors in Digital Multimeters

Similar documents
Keysight Technologies Eliminate Potential Measurement Errors and Achieve the Greatest Accuracy in Digital Multimeters

Agilent E8460A 256-Channel Reed Relay Multiplexer

Agilent 87415A, 87400A Microwave Amplifiers

Agilent 8761A/B Microwave Switches

Agilent 34970A Data Acquisition / Switch Unit

Agilent E9300 Power Sensors E-Series Technical Overview

PCI Express Receiver Design Validation Test with the Agilent 81134A Pulse Pattern Generator/ 81250A ParBERT. Product Note

Agilent 8902A Measuring Receiver Product Note

Agilent 8644A-1 Phase noise test with the Agilent 8644A and 8665A Signal Generators Product Note

6 Tips for Successful Logic Analyzer Probing

Agilent 8491A/B, 8493A/B/C, 11581A, 11582A and 11583C Coaxial Attenuators dc to 26.5 GHz

Agilent 970-Series Handheld Multimeters Data Sheet

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth

Agilent Highly Accurate Amplifier ACLR and ACPR Testing with the Agilent N5182A MXG Vector Signal Generator. Application Note

Agilent Combining Network and Spectrum Analysis and IBASIC to Improve Device Characterization and Test Time

Agilent 81600B All-band Tunable Laser Source Technical Specifications December 2002

Agilent E4438C ESG Vector Signal Generator Differential I/Q outputs. Product Note

Agilent dc Electronic Loads Models N3300A-N3307A

Phase Noise Measurement Personality for the Agilent ESA-E Series Spectrum Analyzers

Agilent 83440B/C/D High-Speed Lightwave Converters

Agilent Introduction to the Fixture Simulator Function of the ENA Series RF Network Analyzers: Network De-embedding/Embedding and Balanced Measurement

Agilent 8902A Measuring Receiver

Advanced Test Equipment Rentals ATEC (2832)

Characterizing High-Speed Oscilloscope Distortion A comparison of Agilent and Tektronix high-speed, real-time oscilloscopes

Agilent E8247/E8257C PSG CW and Analog Signal Generators

Agilent 81980/ 81940A, Agilent 81989/ 81949A, Agilent 81944A Compact Tunable Laser Sources

Advanced Test Equipment Rentals ATEC (2832)

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Phase Noise Measurements

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

Agilent 81662A DFB Laser Agilent 81663A DFB Laser Agilent Fabry-Perot Lasers

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832)

Product Note E5100A-2

How to Drive the Agilent Technologies Microwave Matrix and Transfer Switch via the E8483A Microwave Switch/Step Attenuator Driver.

Time-Domain Response of Agilent InfiniiMax Probes and Series Infiniium Oscilloscopes

Agilent PNA Microwave Network Analyzers

Agilent Technologies 8114A 100 V/2 A Programmable Pulse Generator

Base Station Installation and Maintenance

Agilent 4285A Precision LCR Meter

Obtaining Flat Test Port Power with the Agilent 8360 s User Flatness Correction Feature. Product Note

Agilent E8267C PSG Vector Signal Generator

Agilent PNA Series RF Network Analyzers

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Agilent 83711B and 83712B Synthesized CW Generators

Agilent E1345A 16-Channel Low-Offset Relay Multiplexer. Data Sheet. Description. Configuration. C-size Adapter

Agilent EPM Series Power Meters

National Instruments Switches

Using an MSO to Debug a PIC18-Based Mixed-Signal Design

Agilent E8267C/E8257C/E8247C PSG

Jitter Analysis Techniques Using an Agilent Infiniium Oscilloscope

Agilent On-wafer Balanced Component Measurement using the ENA RF Network Analyzer with the Cascade Microtech Probing System. Product Note E5070/71-3

Agilent Equalization Techniques and OFDM Troubleshooting for Wireless LANs

EEE 432 Measurement and Instrumentation

Agilent Technologies 3000 Series Oscilloscopes

Agilent 8766/7/8/9K Microwave Single-Pole Multi-Throw Switches

Agilent N5250A PNA Millimeter-Wave Network Analyzer 10 MHz to 110 GHz

Agilent Optimizing Your GSM Network Today and Tomorrow

Process Control Calibration Made Easy with Agilent U1401A

Agilent PNA Microwave Network Analyzers

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Agilent 83430A Lightwave Digital Source Product Overview

Agilent E1412A 6.5-Digit High-Accuracy Multimeter C-Size

IC Preamplifier Challenges Choppers on Drift

Fallstricke präziser DC- Messungen

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators Data Sheet

Improving TDR/TDT Measurements Using Normalization Application Note

Agilent 8560 E-Series Spectrum Analyzers

Agilent 8920A RF Communications Test Set Product Overview

Agilent Upgrade Guide for the 8510 Vector Network Analyzer Product Note

Precision in Practice Achieving the best results with precision Digital Multimeter measurements

A statistical survey of common-mode noise

expanding the possibilities

Agilent 84904/5/8M Programmable Step Attenuators for Microwave and RF Manufacturing Test Systems

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators

APPLICATION NOTE. Wide Range of Resistance Measurement Solutions from μω to PΩ

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for GSM and EDGE Measurements

EE 241 Experiment #4: USE OF BASIC ELECTRONIC MEASURING INSTRUMENTS, Part III 1

DC Biased Impedance Measurements MOSFET

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Agilent 8560 EC Series Spectrum Analyzers Data Sheet


Agilent PN 4395/96-1 How to Measure Noise Accurately Using the Agilent Combination Analyzers

Agilent 6800 Series AC Power Source/Analyzer

Agilent 4070 Series Accurate Capacitance Characterization at the Wafer Level

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price

Agilent PNA Microwave Network Analyzers

8 Hints for Better Spectrum Analysis. Application Note

Agilent N4000A, N4001A, N4002A SNS Series Noise Sources 10 MHz to 26.5 GHz

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

1433 SERIES. High-Accuracy Decade Resistor User and Service Manual


Agilent How To Accurately Evaluate Low ESR, High Q RF Chip Devices. Application Note

Picking the Optimal Oscilloscope for Serial Data Signal Integrity Validation and Debug

High Accuracy 8-Pin Instrumentation Amplifier AMP02

TL082 Wide Bandwidth Dual JFET Input Operational Amplifier

LF353 Wide Bandwidth Dual JFET Input Operational Amplifier

Keysight Technologies Accurate Capacitance Characterization at the Wafer Level

R-X SERIES. Decade Resistor

Maximizing your reference multimeter, minimizing measurement uncertainties

Transcription:

Digital Multimeter Measurement Errors Series System Cabling Errors and DC Voltage Measurement Errors in Digital Multimeters Application Note AN 1389-1 Introduction When making measurements with a digital multimeter (DMM), common errors will crop up. The following discussion will help you eliminate potential measurement errors and achieve the greatest accuracy with a DMM. This paper covers system cabling errors and dc voltage measurement errors. For an overview of ac voltage measurement errors, see Application Note AN 1389-3. For a discussion of resistance; dc current; ac current; and frequency and period measurement errors, see Application Note AN 1389-2. (NOTE: The Agilent 34401A, a 6-1/2-digit, high-performance DMM with both benchtop and system features, will be used as an example throughout this article).

System Cabling Errors Radio Frequency Interference Most voltage-measuring instruments can generate false readings in the presence of large, high-frequency signal sources such as nearby radio and television transmitters, computer monitors, and cellular telephones. Highfrequency energy can also be coupled to the multimeter on the system cabling. To reduce interference, try to minimize the exposure of the system cabling to high-frequency RF sources. If the application is extremely sensitive to RFI radiating from the multimeter, use a common mode choke in the system cabling, as shown in Figure 1, to attenuate multimeter emissions. Thermal EMF Errors Thermoelectric voltages, the most common source of error in lowlevel voltage measurements, are generated when circuit connections are made with dissimilar metals at different temperatures. Each metal-to-metal junction forms a thermocouple, which generates a voltage proportional to the junction temperature. It is a good idea to take the necessary precautions to minimize thermocouple voltages and temperature variations in lowlevel voltage measurements. The best connections are formed using copper-to-copper crimped connections. Figure 2 shows common thermoelectric voltages for connections between dissimilar metals. Figure 1. Noise Caused by Magnetic Fields When you make measurements near magnetic fields, take precautionary steps to avoid inducing voltages in the measurement connections. Voltage can be induced by either movement of the input connection wiring in a fixed magnetic field, or by a varying magnetic field. An unshielded, poorly dressed input wire moving in the earth s magnetic field can generate several millivolts. The varying magnetic field around the ac power line can also induce voltages up to several hundred millivolts. Be especially careful when working near conductors carrying large currents. Copper-to- Approx. µv/ C Copper < 0.3 Gold 0.5 Silver 0.5 Brass 3 Beryllium Copper 5 Aluminum 5 Kovar or Alloy 42 40 Silicon 500 Copper-Oxide 1000 Cadmium-Tin Solder 0.2 Tin-Lead Solder 5 Figure 2. Where possible, route cabling away from magnetic fields, which are commonly present around electric motors, generators, televisions and computer monitors. In addition, when you are operating near magnetic fields, be certain that the input wiring has proper strain relief and is tied down securely. Use twisted-pair connections to the multimeter to reduce the noise pickup loop area, or dress the wires as closely together as possible. 2

R L = Lead Resistance R i = Multimeter Isolation Resistance V ground = Voltage Drop on Ground Bus Figure 3. Noise Caused by Ground Loops When you measure voltages in circuits where the multimeter and the device-under-test (DUT) are both referenced to a common earth ground, a ground loop is formed. As shown in Figure 3, any voltage difference between the two ground reference points (V ground ) causes a current to flow through the measurement leads. This causes errors, such as noise and offset voltage (usually powerline related), which are added to the measured voltage. The best way to eliminate ground loops is to maintain the multimeter s isolation from earth; do not connect the input terminals to ground. If the multimeter must be earth-referenced, be sure to connect it and the DUT to the same common ground point. This will reduce or eliminate any voltage difference between the devices. Also, whenever possible, make sure the multimeter and DUT are connected to the same electrical outlet. 3

DC Voltage Measurement Errors Common Mode Rejection Ideally, a multimeter is completely isolated from earth-referenced circuits. However, there is finite resistance between the multimeter s input LO terminal and earth ground, as shown in Figure 4. This can cause errors when you measure low voltages that are floating relative to earth ground. Noise Caused by Injected Current. Residual capacitances in the multimeter s power transformer cause small currents to flow from the LO terminal to earth ground. The frequency of the injected current is the power line frequency or possibly harmonics of the power line frequency. The injected current is dependent upon the power line configuration and frequency. A simplified circuit is shown in Figure 5. V f = Float Voltage R s = DUT Source Resistance Imbalance R i = Multimeter Isolation Resistance (LO-Earth) C i = Multimeter Input Capacitance ( 200 pf LO-Earth) Error (v) = V f x R s R s +R i Figure 4. Injected Current (50/60 Hz ac line leakage current) Figure 5. 4

Note: The measurement noise caused by injected current can be significantly reduced by setting the integration time of the DMM to 1 power line cycle (PLC) or greater. Figure 6. With Connection A (see Figure 6), the injected current flows from the earth connection provided by the circuit to the LO terminal of the DMM, adding no noise to the measurement. However, with Connection B, the injected current flows through the resistor R, thereby adding noise to the measurement. With Connection B, larger values of R will worsen the problem. Loading Errors Due to Input Resistance Measurement loading errors occur when the resistance of the DUT is an appreciable percentage of the multimeter s own input resistance. Figure 7 shows this error source. To reduce the effects of loading errors, and to minimize noise pickup, set the Agilent 34401A s input resistance to greater than 10 GΩ for the 100 mvdc, 1 Vdc, and 10 Vdc ranges. The input resistance is maintained at 10 MΩ for the 100 Vdc and 1000 Vdc ranges. V s = Ideal DUT Voltage R s = DUT Source Resistance R i = Multimeter Input Resistance (10 MΩ or >10 GΩ) Figure 7. Error (%) = 100 x R s R s +R i 5

Loading Errors Due to Input Bias Current The multimeter s input capacitance will "charge up" due to input bias currents when the terminals are open-circuited (if the input resistance is 10 GΩ). The multimeter s measuring circuitry exhibits approximately 30 pa of input bias current for ambient temperatures from 0 C to 30 C. Bias current will double (x2) for every 8 C change in ambient temperature above 30 C. This current generates small voltage offsets dependent upon the source resistance of the DUT. This effect becomes evident for a source resistance of greater than 100 kω, or when the multimeter s operating temperature is significantly greater than 30 C. i b = Multimeter Bias Current R s = DUT Source Resistance C i = Multimeter Input Capacitance Figure 8. Error (v) = i b x R s 6

Conclusion A modern DMM such as the 34401A has many features to help protect you from many common sources of error. However, when making low-level or precise measurements, you must be more aware of sources that contribution to measurement errors. Environmental conditions such as changes in temperature, RF signals and electromagnetic fields will have a significant impact on the quality of DMM measurements. Once the measurement environment has been optimized, proper cabling can significantly reduce measurement errors. The remaining sources of error can be calculated and added to the measurement uncertainty. For more information about the Agilent 34401A, go to www.agilent.com/find/34401a 7

Agilent Technologies' Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent's overall support policy: "Our Promise" and "Your Advantage." Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. By internet, phone, or fax, get assistance with all your test & measurement needs Online assistance: www.agilent.com/find/assist Phone or Fax United States: (tel) 1 800 452 4844 Canada: (tel) 1 877 894 4414 (fax) (905) 282 6495 China: (tel) 800 810 0189 (fax) 800 820 2816 Europe: (tel) (31 20) 547 2323 (fax) (31 20) 547 2390 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Korea: (tel) (82 2) 2004 5004 (fax) (82 2) 2004 5115 Latin America: (tel) (305) 269 7500 (fax) (305) 269 7599 Taiwan: (tel) 080 004 7866 (fax) 080 028 6331 Other Asia Pacific Countries: (tel) 1 800 375 8100 (fax) (65) 836 0252 (e-mail) tm_asia@agilent.com Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2002 Printed in the USA January 31, 2002 5988-5511EN