TS-700/1000 INVERTER Instruction Manual

Similar documents
Sine Wave Power Inverter GD150/GD300 Series User s Manual

SA-150, SA-300 Series Pure Sine Wave Inverter User s Manual

SHI Series Pure Sine Wave Inverter (SHI2000 AND SHI3000) User s Manual

User s Manual Before using the inverter, you need to read and save the safety instructions.

Operation Manual. Congratulations on purchasing your high quality AIMS Power pure sine inverter!

SK Series Pure Sine Wave Inverter User s Manual

AC-DC BATTERY CHARGER 120~230W Portable Battery Charger 300~1000W Stationary Battery Charger

SK Series Pure Sine Wave Inverter. User s Manual

Pure sine wave inverter USER S MANUAL

AC-DC BATTERY CHARGER 120~326W Portable Battery Charger 300~1000W Stationary Battery Charger

Dawson DDM190. Digital Multimeter User s Manual

AC MASTER Switch mode sine wave inverter

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

Precautions in Using the product:

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

- 1 - GTI Grid Series. GTI Series Inverters For Grid User Manual

DVM1190 DIGITAL MULTIMETER

Product Catalog PRODUCT CATALOG. Power supply system & test equipment

GTI Series Inverters User Manual

Operation Manual. SWF Series Switch Mode Power Supply. SANKEN ELECTRIC CO., LTD No.PAN E-01.

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

SR-1600 User s Manual. Telecom / Datacom PURE SINE WAVE INVERTER

AV30MX-2 Operation Manual

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

SK200,SK350 Series Pure Sine Wave Inverter User s Manual

THMS WATT WATT PEAK Other Models

MS2109A AC/DC Clamp Meter. User Manual. Contents

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

DLP/E Series Instruction Manual

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

DDM350 Pen-Type Digital Multimeter User s Manual

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

Capacitive Proximity Sensor

AMM-1022 Digital Multimeter USER`S MANUAL

Tel: Fax:

C-Bus 8 Channel Low Voltage Relay

DCM730. Digital Clamp Meter User s Manual

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

ProfiScale MULTI Multimeter

Challenger 400. Instruction manual

VC835 DIGTAL MULTIMETER Operation Manual

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

O. S. WALKER MICROPROCESSOR CHUCK CONTROL MODEL MSB SERIES TABLE OF CONTENTS

2015 RIGOL TECHNOLOGIES, INC.

Multifunction Digital

Power supply CP-D 24/4.2 Primary switch mode power supply

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

MASS SINE 12/800, 24/800 & 48/ V sine wave inverter

INSTALLATION & OPERATION MANUAL

Aqua-Gen 3PV INSTRUCTIONS

AC/DC CLAMP METER USER S MANUAL

DIGIT & POINTER MULTIMETER

Aqua-Gen 3BR INSTRUCTIONS

Power supply CP-D 12/2.1

OPERATOR S INSTRUCTION MANUAL

MC450/MC650 (MC750) OPERATING INSTRUCTIONS

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

24 VDC, 1000 Watt/ 48 VDC, 2000 Watt Rectifier Installation / Operation Manual

Instruction Manual. The AquaSun 3RP is a premium automatic solar controller with temperature adjustment, manual, winter mode features.

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

REVAMP4120T Instruction manual

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

NOVA ELECTRIC A DIVISION OF

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

High Frequency SineWave Guardian TM Filter

Power supply CP-D 24/1.3

DIGITAL MULTIMETER INSTRUCTION MANUAL

SPECIFICATION EP 1000/1500/2000 Series

200A type has been added. High Capacity of Max. 1,000 V DC Cut-off Possible

Contents. Instruction Leaflet IL E Effective March HMi VU Series Instruction Leaflet. Description... Page. Preface...

SD Series User s Manual SD2500 / SD3500 PURE SINE WAVE INVERTER

DIGITAL RADIO INCLUDING FM, DAB AND DAB+

CONTENTS MS2033A. 1.Introduction Safety Information...01

Jameco SKU Number:

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES ECE R10-05

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

XES-M50 Operating Instructions

Power supply CP-E 24/0.75

Fuzzy Temperature Controllers E5AF

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

Thank you for purchasing a qualiton A20i power amplifier!

3B SCIENTIFIC PHYSICS

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL

INSTALLATION & OPERATION MANUAL

DPA-1200 ORDERCODE D4180 DPA-2400 ORDERCODE D4181 DPA-3400 ORDERCODE D4182

USER'S MANUAL DMR-6700

CLASS D MONO AMPLIFIER GM-D8601 GM-D9601. Owner s Manual

Autoranging Multimeter Extech EX503

HOT ROD 500S OPERATOR S MANUAL IM /2016 REV05 ENGLISH

AC750 DIGITAL CLAMP METER

Ver Tornado KT2 - KT2C KTL2 - KTL2C. USER GUIDE English KT2 KTL2 KT2C KTL2C

Transcription:

TS-700/1000 INVERTER Instruction Manual

TS-700/1000 Instruction Manual Index 1. Safety Guidelines... 1 2. Introduction... 1 2.1 Features... 1 2.2 Main Specification... 2 3. User Interface... 2 3.1 Front Panel... 2 3.2 LED Indicator on Front Panel... 3 3.3 Rear Panel... 3 4. Setup (Output Voltage, Frequency, and Saving Mode)... 4 4.1 Initial State... 4 4.2 Procedure of Setting Up Output Voltage, Frequency, and Saving Mode... 4 5. Protection... 6 5.1 Input Protection... 6 5.2 Output Protection... 6 6. Installation & Wiring... 7 7. Failure Correction Notes... 10 8. Warranty... 10

1.Safety Guidelines (Please read through this manual before assembling TS- 700/1000) Risk of electrical shock and energy hazard. All failures should be examined by the qualified technician. Please do not remove the case of the inverter by yourself! Please do not install the inverter in places with high moisture or near water. Please do not install the inverter in places with high ambient temperature, under direct sunlight or near flame source. Please only connect batteries with the same brand and model number in one battery bank. Using batteries from different manufacturers or different capacity is strictly prohibited! Never allow a spark or flame in the vicinity of the batteries because it may generate explosive gases during normal operation. Make sure the air flow from the fan is not obstructed at both sides (front and back) of the inverter. Please allow at least 15cm of space. Please do not stack any object on the inverter. Warning: Batteries will have aging problem after years of operation. It is suggested to execute regular maintenance for the batteries every year. Once aged, the batteries should be changed by professional technician, or the failed batteries may cause explosion or fire hazard. Don't disassemble Away from moisture Away from fire or high temperature Don't stack on the inverter Keep good ventilation WARNING : This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. 2.Introduction Fully digital controlled by an advanced CPU, TS-700/1000 is a true sine wave DC/AC, Drawing power from battery bank and converting it into AC voltage. With pure sine wave output, TS-1000 can provide 1000W continuously, 1150W for 3 minutes, and surge power 2000W. (TS-700 can provide 700W continously, 800W for 3 minutes, and surge power 1400W.) General applications include PC, ITE, vehicles, yachts, home appliances, motors, power tools, industrial control equipments, AV systemsand etc... 2.1 Features True sine wave output (THD < 3.0% ) 700W / 1000W rated output High efficiency up to 92% Complete LED indication for operation status low alarm and indicator Output voltage / Frequency selectable 1

2.2 Main Specification TS-700 O U T P U T I N P U T TS-1000 O U T P U T I N P U T Fully digital controlled including monitoring & display Compliance to UL458(only TS-1000) / FCC / E 13 / CE Can be used for most electronic products with AC input 2 years global warranty Model Rated power AC voltage Waveform Protection Bat. voltage range DC current Efficiency Off mode current draw Protection Model Rated power AC voltage Waveform Protection Bat. voltage range DC current Efficiency Off mode current draw Protection 112 10.5 ~ 15.0V 21.0 ~ 30.0V 42.0 ~ 60.0V 10.5 ~ 15.0V 21.0 ~ 30.0V 42.0 ~ 60.0V 75A 86% Under 1.0mA at power switch OFF 112 10.5 ~ 15.0V 21.0 ~ 30.0V 42.0 ~ 60.0V 10.5 ~ 15.0V 21.0 ~ 30.0V 42.0 ~ 60.0V 100A 88% 124 700W max. continuously, 800W max. for 180 seconds, 1050W max. for 10 seconds 1400W (30cycles) 38A 88% 124 2000W (30cycles) 50A 89% 148 19A 89% 148 25A 90% Under 1.0mA at power switch OFF 75A 89% 100A 90% 38A 90% 50A 91% 19A 91% 1000W max. continuously, 1150W max. for 180 seconds, 1500W max. for 10 seconds AC short Overload Over Temperature AC short Overload Over Temperature 212 True sine wave (THD <3.0%) at rated input voltage 212 224 224 248 Over current battery polarity reverse by fuse battery low shutdown battery low alarm True sine wave (THD <3.0%) at rated input voltage 248 25A 92% Over current battery polarity reverse by fuse battery low shutdown battery low alarm 3.User Interface 3.1 Front Panel A POWER ON/OFF switch: The inverter will turn OFF if the switch is in the OFF position. B AC output outlet: For application demands of different geographic areas all over the world, there are many different kinds of optional AC outlets to choose from. 2

C Ventilation holes: The inverter requires suitable ventilation to work properly. Please make sure there is good ventilation and the lifespan of the inverter can be preserved. D Function Setting: Output voltage, frequency, and saving mode can be set through this button. E LED Indicating Panel: Operating status, battery status, load condition, and all kinds of warnings will be displayed on this panel. B C AC Output A ON OFF Setting D E Remote port Figure 3.1: Front Panel 3.2 LED Indicator on Front Panel LED: Represents current operating status LED color Note: Refer to section 5.2 for explanation of abnormal status LED LED color capacity LOAD LED LED color percentage 3.3 Rear Panel A B input (+),(-) Green Normal Represents the remaining capacity of external batteries Green >70% Represents the magnitude of output load Green Fan ventilation opening C Frame ground (FG) Orange Saving mode Orange 40 ~ 70% Orange Red Abnormal Red <40% Red <50% 50 ~ 80% >80% WARNING: B NEG Reverse Polarity Will Damage The Unit. BATTERY POS Cat.No.(1GG1HS-212) Wire Range(10-4 AWG Str Cu Soldered Wires) Torque (17.7-26.5 in lb) A Chassis Ground C Fig 3.2: Rear Panel 3

4.Setup (Output Voltage, Frequency, and Saving Mode) 4.1 Initial State The initial state is 110Vac/60Hz or 230Vac/50Hz and the "Saving Mode" is activated. If users need to revise it for certain application, it can be done the setting button on the front panel (Please refer to section 4.2). The unit will start up automatically after the setting procedure is finished and the new settings will be executed. These new settings will be kept even if the unit is power off/on for any reason. 4.2 Procedure of Setting up Output Voltage, Frequency, and Saving Mode STEP 1: The inverter should be turned off while resetting. Input batteries should be connected and the loads should be removed. STEP 2: Use an insulated stick to press the setting button and then turn on the power switch. Orange led indication will flash ON and OFF. after pressing for 5 seconds, the inverter will send out a "Beep" sound. Users can release the button and go into the setting procedure. STEP 3: Please refer to Table 4-1 and check whether the combination of output voltage and frequency is the one you need. If yes, please jump to STEP 5. If not, start from STEP 4. AC Output ON OFF Setting Use an insulated stick to press this setting button Remote port Figure 4.1: Adjustment of Output Voltage, Frequency, and Saving Mode Table 4-1: LED Indication of Output Voltage / Frequency Combination Output Voltage Frequency 50Hz 60Hz 100Vac (200Vac) 110Vac 115Vac 120Vac (220Vac) (230Vac) (240Vac) Light Dark Flashing 4

Note: The above indication will be shown in green STEP 4: The LEDs will change state each time you press the setting button for 1 second and then release (refer to Figure 4.2). Please select the suitable combination of output voltage and frequency you need. 100Vac (200Vac) 50Hz 110Vac (220Vac) 50Hz 120Vac (240Vac) 60Hz 115Vac (230Vac) 50Hz 115Vac (230Vac) 60Hz 120Vac (240Vac) 50Hz 110Vac (220Vac) 60Hz 100Vac (200Vac) 60Hz Figure 4.2: State Circulation Diagram of Output Voltage and Frequency STEP 5: After selecting the output voltage and frequency, press the setting button for 3~5 seconds and the inverter will send out a "Beep" sound. The button can be released and it goes into the setting section of "Saving Mode". STEP 6: Please refer to Table 4-2 and check whether the "Saving Mode" is already set as you desired. If yes, please jump to STEP 8. If not, start from STEP 7. Table 4-2 : LED Indication of Saving Mode Selection Saving Mode ON Saving Mode OFF Note: The above indication will be shown in green Light Dark Flashing STEP 7: The LEDs will change state each time you press the setting button for 1 second and then release. Please activate or cancel the "Saving Mode" function as desired. STEP 8: After activating or canceling the "Saving Mode", press the setting button for around 5 seconds and the inverter will send out a "Beep" sound. The button can be released and all the settings are finished. The inverter will automatically store all the settings and start to operate. 5

5.Protection 5.1 Input Protection (A) Polarity Protection: If the battery input is connected in reverse polarity, the internal fuse of the inverter would blow and the inverter should be send back to MEAN WELL for repair. (B) Under Voltage Protection: When the battery voltage is lower than the preset value, the inverter will automatically terminate the output thus protect the battery from damage. Please refer to Table 5-1 for more detail about the failure signals. (C) Over Voltage Protection: When the battery voltage is too high, inverter will automatically terminate the output providing and the built-in buzzer will be activated to inform the users. Please refer to Table 6.1 for more detail about the failure signals. Warning: Please choose suitable batteries that is compatible with the rated input DC voltage of TS-700/1000 (refer to the SPEC). If the input DC voltage is too low (ex. using 12Vdc battery bank for 24Vdc input models), TS-700/1000 can not be started up properly. If the input DC voltage is too high (ex. using 48Vdc battery bank for 24Vdc input models), TS-700/1000 will be damaged! 5.2 Output Protection The display panel will show failure status when inverter is faced with abnormal operating conditions (refer to Table 5-1). This lets the user know what could be the problem. (1)OTP: When the internal temperature is higher than the limit value, the "Over Temperature Protection" will be activated. The unit will automatically turn off and should be restarted again. (2)AC output abnormal protection: When the AC output voltage of the inverter is too high or too low, the unit will turn off and should be restarted again. (3)AC output short circuit protection: When a short circuit situation occurs at the output side of the inverter or the loads increase greatly in a short period of time, the unit will turn off and should be restarted again. (4) voltage abnormal protection: When the battery voltage is too high or too low, this protection will be activated. The inverter will auto recover after the battery voltage go back to a safe level and users do not need to restart it. ( 5 ) O L P : W h e n o u t p u t i s o v e r l o a d e d b e t w e e n 7 3 5 ~ 8 0 0 W ( T S - 700)/1050~1150W(TS-1000), the inverter can still continuously provide power for 3 minutes. After that, if the overload condition is not removed, overload protection will activate. When the load is higher than 1050W(TS- 700)/1500W(TS-1000), the overload protection will be activated instantly. For these overload protections, once activated, the unit must reset to recover. 6

Failure Message Output Overload (105~115% load) Output Overload (115~150% load) Output Overload (150% load) Over Temperature Table 5-1: Failure Messages On Front Panel LED Indicator Note: The above indication will be shown in red Failure Message Abnormal AC Output Voltage AC Output Short Circuit Abnormal Voltage LED Table 6-1: Suggestion for Wire Selection LED Indicator Light Dark Flashing 6.Installation & Wiring (A)Wiring for Batteries: Wire connections should be as short as possible and less than 1.5 meter is highly recommended. Make sure that suitable wires are chosen based on the rating of current. Too small of a cross-section will result in overheating that could induce certain danger. Please refer to Table 6-1 and consult our local distributors if you have any questions. Rated Current of Equipment (Amp) Cross-section of Lead (mm 2 ) 16A ~ 25A 25A ~ 32A 32A ~ 40A 2.5 4 6 12 10 8 Model using 48V battery 40A ~ 63A 63A ~ 80A 10 16 6 4 Model using 24V battery 80A ~ 100A 100A ~ 125A 125A 25 35 50 2 1 0 Model using 12V battery (B)Suggested battery type and capacity type Capacity Lead-acid battery 112 212 124 224 148 248 12V / 120Ah ~ 24V / 60Ah ~ 48V / 30Ah ~ 12V / 400Ah 24V / 200Ah 48V / 100Ah 7

(C)Requirement of Installation: The unit should be mounted on a flat surface or holding rack with suitable strength. In order to ensure the lifespan of the unit, please refrain from operating in environment of high dust or high moisture. This is a power supply with built-in DC fan. Please make sure that ventilation is not blocked. There should be no barriers within 15cm of the ventilating holes. >15cm Air >15cm Air Figure 6.1: Example of Installation (D)Mounting Suggestion : There are 4 semi-circular cutout on the side flanges of the inverter. It can be used for fixing TS-700/1000 onto the system enclosure. We high recommend mounting in the horizontal position. Please make sure ventilation openings are free from obstruction. (E)Example of system diagram As short as possible AC O/P Larger than 15cm LOAD + - Larger than 15cm TS-700/1000 DC I/P - + Chassis Should less than 1.5m Wall or system FG 8

Where, the DC I/P and chassis fix manner as following : 1. Company Name : Mean Well Enterprises Co Ltd 2. Model Name : 1GG1HS-191 3. Rating : 150A 4. Torque : 106.2 Ib.in max. 5. Suitable Wire : Copper wire (temp rating : 75C ) 6. Intended for termination onto a Listed ring tongue connector 7. To Be Sold Only With Installation Instructions 8. A mounting screw that is first inserted through the tang and is threaded into the connector to secure the connector to the tang shall be torqued to 32 in-lbs minimum 9. Mounting Screws - Plated Steel. Two provided, size M4 Cat.No.(1GG1HS-212) Wire Range(10-4 AWG Str Cu Soldered Wires) Torque (17.7-26.5 in lb) Chassis (F)Derating 100 100 80 80 LOAD (%) 60 40 LOAD (%) 60 40 20 20 0 10 20 30 40 50 60 70 Ambient Temperature ( ) 10.5VDC 21VDC 42VDC 11.5VDC 23VDC 46VDC 15VDC 30VDC 60VDC (HORIZONTAL) Figure 6.2: Output Derating Curve Input Voltage (V) Figure 6.3: Input Derating Curve (G) Notes on output load: TS-700/1000 Series can power most of equipments that need an AC source which can provide 700W(TS-700)/1000W(TS-1000) continuously. But for certain load type, the unit may not work properly. 9

(1)Since inductive loads or motor based equipments need a large start up current (6~10 times of its rated current), the inverter may not start up successfully with these kinds of load. (2)When the output are capacitive or rectified equipments (such as switching power supply), it is suggested to operate these equipment at no load or light load. To ensure proper operation, you should increase the loads only after TS-700/1000 has started up. 7. Failure Correction Notes TS-700/1000 should be serviced by a professional technician. Any improper usage or modification may damage the unit or result in shock hazard. If you are not able to clear the failure condition, please contact Mean WELL or any of our distributors for repair service. Possible Reasons Ways to Eliminate No AC output voltage Discharging period of batteries is too short Fan does not spin Abnormal input Over temperature protection Overload protection Short circuit protection Batteries are aged or broken capacity is too small Clog with foreign bodies Malfunction of the fan Check the AC or DC input sources. Make sure the voltage is within the required range. Make sure that the ventilation is not blocked or whether the ambient temperature is too high. Please derating the output usage or reduce the ambient temperature. Make sure the output load does not exceed the rated value or the instantaneous start up current is not too high. (for inductive or capacitive loads) Make sure the output is not overloaded or short circuited Replace the batteries Reconfirm the specification and enlarge the battery capacity as suggested Remove the foreign objects Repair required. Please send it back to us or any of our distributors 8. Warranty Two years of global warranty is provided for TS-700/1000 under normal operating conditions. Please do not change components or modify the unit by yourself or MEAN WELL may reserve the right not to provide the complete warranty. 10