PRODUCT LEAFLET AUGIER-BOX. Remote Monitoring Unit for Street Lighting /07/2011

Similar documents
Communication by power line carrier technology. For medium voltage networks

Power Meter Series PM3200 Functions and characteristics

TRMC-19 GSM/GPRS DATALOGGER. Applications. Product description. Measure and remote monitoring

02/11/2015

PECA 30E. Analyseur de signaux alternatifs Signal Analyser for Electrical Networks

DIRIS Ap RS485 JBUS/MODBUS COM. Systèmes de Coupure et de Protection Industrial Switching and Protection Systems ON 1

GEONICA, S.A. - Alejandro Rodríguez, nº Madrid - Spain Tel Fax

JOINT STOCK COMPANY. MULTICHANNEL RECEIVER RI-4010M (version RM ) User guide

SULTANATE OF OMAN METERING AND DATA EXCHANGE CODE

GPS&GPRS TRACKING SYSTEM GT3100

SINGLE PHASE STS PREPAID METER

ATB200. Datasheet. ATB200 GPRS / GPS based Fleet Management Terminal. 1

QUICK GUIDE for multiguard Light. Installation

R-Log Radio data logger

NETWORK ANALYZERS Analyzers

02/11/2015

Main Features. Highlights

Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3

R&D TECHNICAL SPECIFI

MT372 Three-phase electronic meter with built-in modem or RS485 communication interface

The wireless alternative to expensive cabling...

GPRS-T2. GPRS/SMS Reporting Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

DIRIS A40/A41 RS485 PROFIBUS DP. Operating instructions F GB D I NL E P. SOCOMEC GROUP switching PROTECTION & ups

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

Frequency selective monitoring and logging of environmental electromagnetic fields

JBUS/MODBUS communication card

Electrical network management. Schneider Electric. PM3200 Technical Datasheet

DIGITAL SWITCH MODE POWER SUPPLIES MAIN APPLICATIONS GENERAL INTRODUCTION TO QP23 SERIES

AUTOMATIC WEATHER AND HYDROLOGICAL STATIONS

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

English RACON SERIES II RADIO CONTROL SERVICE MANUAL

DIRIS A40/A41 RS485 PROFIBUS DP COM. Operating instructions. PROFIBUS Certification

U1601 ENERGY CONTROL SYSTEM

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

PLA 33. Power line analyzer. User and service manual. version 2.4

Street lights management solutions

HAWK5000 Operators Manual

SMS control unit for SRK transmitters

M-Bus Master MultiPort 250L Installation and User Guide

The wireless alternative to expensive cabling...

SonoMeter 31 Energy Meters

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

em4 em4 alert em4 alert 2G

KNC-SRV-FD423 Series Servo Driver

Energy Management Three-phase energy meter with output modules Type EM4-DIN

PQM4000RGW Class A DIN 192x144 power quality analyzer with Rogowski coils

Brochure nº

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Smart Energy & Power Quality Solutions. UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC)

8450 Series CellGuard TM Power / VSWR Monitors

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

LineTroll R110C GSM communication unit for LineTroll 110EµR phase-mounted fault indicator

U ACTIVE SAT DISTRIBUTION FIELD

Remote Site Monitoring

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

DL.WMS/GPRS/R/SDI-12. Watermanager solution CUSTOMER BENEFITS

SUPPLY NETWORK ANALYZER CVM-96 SERIES

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

IDA 4 XM V 1.X. Installation and configuration of IDA 4 XM User Manual

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Energy Management Energy Meter Type EM340

Watermanager solution DL.WMS/GPRS/R

( F L O W I Z F A M I L Y )

DIN Rail Kilowatt Hour Energy Meters

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

Protection components

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Control solutions Biofloor

Utility Communications Teleprotection Equipment TPT-200

Energy Management Modular Power Analyzers Type WM2-96

PowerPlex Compact Module PP-C-COM24

M.3. Electrical measurement and control. Electrical energy meters for partial consumption

RADIATED IMMUNITY TEST SYSTEM 6 GHz

Programmable AC Current Transducer MT418

METERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering

PQM3000R Class A network analyzer according to EN for power quality monitoring

Energy Management Compact Power Transducer Type CPT-DIN Basic version

Power IT LV Active Filters PQFI PQFM PQFK. The ABB comprehensive solution for active filtering of harmonics

DPF-MAC Auto power factor controller

E35C. AD-FG/CG/GG Version 3.2. Technical Data. Communication Module Residential

B850 Boiler House Energy Monitor

M508 GPS Tracking Device

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

Technical description MT24. User manual WARNING GENERAL INSTRUCTIONS GENERAL DESCRIPTION

The FM 3517i on-board computer interfaces directly with the vehicle s data bus supporting the CAN - J1939 and J1708 / J1587 standards.

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

sustainable savings that can be viewed directly on the internet

Documentation. Measurement and Control. Type: ELT-GP2

KanAtoN 1 / 3 AIS Transponder. Installation Manual

SOUTHERN AVIONICS COMPANY. SE125 Transmitter. SE125 Transmitter 1-1

ICARUS ELECTRONIC GAS VOLUME CONVERTER

PEM353. Universal measuring device

isma-b-w0202 Modbus User Manual GC5 Sp. z o.o. Poland, Warsaw

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

ELECTRONIC SINGLE PHASE AND THREE PHASE L.V. METER SPECIFICATIONS

TRX-300. GPS/GSM/GPRS Unit for fleet management PRELIMINARY PHOTO

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

2W UHF MHz Radio Transceiver

Transcription:

PRODUCT LEAFLET AUGIER-BOX Remote Monitoring Unit for Street Lighting 1 60 11432-04/07/2011

Put a TECHNICIAN in each street lighting cabinet, and control them 24H per day! The Augier-Box Programmable Logic Controller monitors all the elements of the electrical lighting cabinet and all events that occur on network. Augier-Box is equipped with a GSM / GPRS modem which warns you : By means of SMS, directly on your cellular phone. Through monitoring station. Reliable, Augier-Box profits from the experiances of AUGIER which is present since many years in street lighting equipment, lighting dimming and airfield lighting systems. Compact and easy to install, it fits easily in an existing installation, thanks to a reduced wiring. General-purpose, it adapts itself to any type of street lighting installation with or without dimmer. Economic at purchase and without maintenance, it allows a fast Return On Invest. Applications Control and monitoring of street lighting, roads and highways, industrial and commercial buildings, architectural and festive lighting, of by-pass and car parks, harbour and airport zones The AUGIER-Box includes An electronic board using a last generation of microprocessor, and allowing control, monitoring, time management, measurement, fault detection. A GSM / GPRS modem, with battery, support for SIM card, and an integrated antenna. An astronomical clock, for the lighting control. Communication ports : USB, RS485/422, CAN, EN62053. Wired Input / outputs : 2 logical inputs, 1 analogical input (4-20mA), 1 relay with one contact, free of voltage. Three state indicators (by LEDs). 2

AUGIER-Box Connectivity BOX N de série 25999/01 Identification BOX-001-50-A-0000 Tension nominale/ Consommation 230V / 5VA OK CAN L CAN H RX + RX - COM IN2 IN2 IN1 IN1 ANA - ANA + Ph A Mes. Ph B Mes. Ph C Mes. Neutre Mes. Phase Alim. Neutre Alim. K K A B C SIM card GSM antenna (local or distant) USB link Contactor control CAN Bus RS485 Pulses inputs (KWh) 2 x wired inputs Analogical Inputs 4-20mA Lighting voltage inputs Power supply 230V~ 120-240Vac AUGIER-Box Functionalities Installed inside the lighting cabinet, it allows to monitor and control all elements of the lighting network: Lighting / Extinction of lighting (control of the main contactor). Measurement of daily, monthly, cumulated consumption. Measurement of instantaneous consumption. Measurement of voltages of the lighting network. Disappearance / Reappearance of the supply and lighting voltages. Lack of engagement of lighting (contactor or control device faulty). Monitoring of a rupture of continuity in the network (cable cut, open protection of a feeder). Monitoring of the state of the lamps: associated with an energy meter, the Augier-Box carries out the follow-up of the consumption, which allows knowing the number of faulty lamps (an alarm will be generated on reaching a programmed threshold). Over-consumption (fault, overload, hacking). These measurements, detections and states are diffused thanks to the components according to: Wireless connection: the Augier-Box includes a modem allowing to communicate any alarm by SMS via the GSM network (tele-alarm sent on a cellular phone), and all other information or measurements via the GSM-data / GPRS network (control and monitoring). Autonomy: a reserve of a few days allows the diffusion of alarms also in the event of total cut of supply. In the event of total discharge of the internal battery, all the parameter setting remains preserved: no intervention is necessary at the time of the return the main voltage. Integrated Astronomical Clock: it is associated to an output relay allowing controlling the main contactor of the lighting installation. Bus Communication: the Augier-Box includes buses of different technologies (CAN, RS485, EN62053), authorizing direct connection with modules or others communicating equipment. 3

Communications Each Augier-Box has its own identity (coding on 16 characters), geographical coordinates of longitude and latitude (for the astronomical clock and a geo-localisation). It has in memory, phone numbers in order to send information towards the standby personnel, and also memorizes the log of the last events which have occurred. Communication with the standby personnel is carried out by mean of SMS via the GSM network, in a bidirectional way : the Augier-Box can be at the origin of the call (on alarm or event), or receive a call for consultation (remote readings operated from a cellular phone). Communication with a monitoring system is carried out via the GSM Data / GPRS network CAN, RS485 and EN62053 links allow all extensions towards other analysis systems, or other AUGIER equipment to be controlled (Dimmers type COMPACTO, OPTIMOFLUX, Augier swithgears type EP12-EP13 or CDE12-13). An USB socket in front allows the local connection of a notebook PC for control and parameter setting. A Very Simple User Interface OK Three indicators allow to know the operating condition of the Augier-Box : Yellow : Lighting fault (lack of control, lamps fault, etc ) Red : Augier-Box â fault (lack of GSM network, battery out of order, SIM not recognized, etc ) Green : Lighting as well as the Augier-Box â correctly working. Control Parameters A Plug & Play operation : the software installed on the PC detects automatically the Augier-Box â and presents a simple user interface allowing to fulfil the necessary parameters for an operational use (phone numbers in the event of alarm, thresholds, etc ). The Augier-Box is delivered regulated, ready to install. Using the provided software and a standard PC having an USB socket, it is possible to modify all parameters, which allows to adapt any particular application (Street Lighting installation with or without dimmer, metering, control of lighting, etc ). The Augier-Box can be parameterized without live voltage, which ensures a maximum safety. USB link 4

PC Software for AUGIER-Box parameters Each AugierBox could be adjusted using the supplied PC sofware. The main parameters are date, time, GPS positions, alarms settings, cellular phone numbers for alarm sending. Global Supervision This window give information regarding: State of the GSM connexion, Current time & date, Sun set and sun rise times calculated by the astronomical clock, Voltage on the 3 phases (if connected). Power per phase and total power (connexion with an optionnal energy meter or a dimmer type Compacto II), Total energy consomption (same option) Estimated load, in ohms (same option), Calculated power factor (same option). Astronomical Clock Settings This window manages the astro. clock: Typing the GPS position of the cabinet Increasing or decreasing the proposed times for switching ON & OFF the lighting contactor with a time delay from 1 to 60 mn (for example: if shadow from mountains or buildings), Managing the times to force a switching on & off of the lighting contactor, Displaying the state of the forced position Settings of the Sim card & Telephonic modem Typing PIN code, Technicians cellular tel numbers, Limitation of SMS sent per day, password of AugierBox Alarm settings & labels Typing the thresholds for all alarms, Typing the label of 2 alarms connected on inputs 5

Interfaces with Monitoring Systems The Augier-Box is mainly used for Communication between a dimmer type Compacto (I or II) and / or an electrical energy metering unit. The Augier-Box sends alarms & states, via SMS or through GSM communication, or via an optic fibre network. The Augier-Box also transfers commands: changement of voltage thresholds, on/off, Site installation in cabinets There are 3 kinds of installation, on site: The Augier-Box stands alone for voltage control and alarms, The Augier-Box could communicate, by serial link RS485 with : - an energy meter, - a system to monitor each lamp, by power carrier line technolgy. The Augier-Box could be associated with some dimmers type Augier Compacto or equivalent. In this application, the Augier-Box operates as a GSM modem for the PC software of the dimmer, which parameters such as times Or voltages of cost saving periods could be modified. 6

Insertion in a Street Lighting network POWER SUPPLY NETWORK One phase or three phases network The Augier-Box is easy to install in the lighting cabinet : 230V~ From power supply between 120 to 240 Vac, Contactor with the lighting contactor from the relay «K», with some Augier Compacto dimmers by CAN bus, with an energy meter by serial link RS485, COMPACTO 1 or 3 phases K K CAN H Box Line supply CAN L Neutral supply with the voltage network (in general after the dimmer), By the 3 phases and neutral inputs Ph C Mes. Ph B Mes. Ph A Mes. Neutral Mes. with 2 logical inputs for alarms (for example a contact «door opened», and a contact ENERGY METER (Kwh, Cos phi, KVAR) RS485 output RX+ RX- free of voltage from a external equipment) with 1 analogical input 4 20 ma (use to be defined) LIGHTING CABINET LIGHTING NETWORK Electrical Characteristics : Mechanical Characteristics : Power Supply : 120-230V +-10%, 45 Hz - 65 Hz. Consumption : 2W (5W in GSM communication). CAN L, CANH : 12V / 250 KBauds RX+, RX- : RS485, MODBUS Protocol. A, B, C, COM : Impulse inputs (EN62053-31). IN1, IN2 : Inputs contacts free of voltage 5V/10mA ANA-, ANA+ : Input 4-20mA (R input = 500Ω). Meas. Phase A, B, C : Inputs 80/250V~ (precision ±1%). K Output : contact free of voltage NO (250V~ 6A). USB socket : Standard connector B. GSM socket : FME Male. GSM/GPRS Unit : 850, 900, 1800, 1900 MHz. Protection : Internal fuse. Protection : IP 20. Fixing : DIN rail EN 60715 TH35. Dimension : 9 units, L 160 x P 58 x H 90 mm Ambient temperature : from -20 C to +55 C. Humidity : from 0 to 85 % without condensation. Altitude : lower or equal to 2000 m. Weight : 350 g. Dimensions to be added, for the options: 1 unit DIN (L = 18mm) per phase, in the case of a simple power measurement. 6 units DIN (L = 107mm) for an improved meter integrating measurements of power-factor and reactive energy. 7

AUGIER EST CERTIFIE ISO 9001 DEPUIS 1995 Dans un souci d'améliorations constantes, le fabricant se réserve le droit de modifier ses modèles sans préavis. 8