SX (690 V) System configuration

Similar documents
SX (400 V) System configuration

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

SX (400V) System configuration

Emotron FDU 2.0 Variable Speed Drive

Emotron FDU 2.0 Variable Speed Drive

Dynamic drives for low power AC motors

ACH550 HVAC Drive Submittal

S11 Adjustable Speed Drive Engineering Specification

vacon nxs robust drive for heavy use

VF-nC1 Adjustable Speed Drive Engineering Specification

VFB40 Frequency inverters 004 to 016 (B1) VFX40 Frequency inverters 018 to 037 (S2)

FDU50 Frequency inverters 018 to 037 (S2) FDU50 Frequency inverters 046 to 060 (X2)

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

Inverter Drive /Vector Drive Motors & Controls

TECHNICAL CATALOGUE EMOTRON FLOWDRIVE EMOTRON FLOWDRIVE KW, V IP20, IP21 AND IP54

SJ700 series High performance with Many useful Functions and, yet User Friendly. WJ200 series Pursuing the Ideal Compact Inverter NEW

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

Fan and Pump AC Inverter

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Integrated servo motor

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

E3 Adjustable Speed Drive Engineering Specification

Version number A=standard P=Cold Plate (Frame A only) T=Brake chopper (Frame A only) Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ 43=400VAC

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

General Purpose Drives

SX-F INSTRUCTION MANUAL

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:

WJ200 series Pursuing the Ideal Compact Inverter

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

MICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

Emotron VFX 2.0 Variable Speed Drive

VEMoDRIVE Frequency Converter VSI2.0

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

ADJUSTABLE SPEED DRIVES. AS1 Drive

High power Direct Torque Control Inverters Model: SX-F 400 V Class Three-Phase Input 90 kw to 800 kw 690 V Class Three-Phase Input 90 kw to 1000 kw

PowerFlex 400 Submittal

FUJI Inverter. Standard Specifications

AC Variable Speed Drive. Powerful Performance. Advanced motor control. 0.75kW 250kW / 1.0HP 350HP V Single & 3 Phase Input

SJ series P1 High performance inverter with innovative ease-of-use and excellent driving performance

Manual Overview...1 2

EN 50178, IEC

NX series Constant and variable torque Variable Speed Drives for induction motors

The new Yaskawa Varispeed G7 Inverter

Variable frequency drives; 1-/3-phase 230 V; 10.5 A; 2.2 kw; EMC filters; braking transistor

General Specifications FECA-TE /2010. Phone: Fax: Web:

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

Frequency Inverters. VF-nC3 VF-S11 VF-FS1 VF-PS1 VF-AS1

AF91 Adjustable Frequency Drives Series B

TECO V33 Variable Speed Drive

ADJUSTABLE SPEED DRIVES FS1

Phoenix DX Clean Power (18 Pulse) AC Drive

FLOWDRIVE FDU. Valid for the following inverter Models: FDU to FDU40-1k1 FDU to FDU50-1k1 FDU to FDU69-1k1 Software version: 3.

MV1000 MEDIUM VOLTAGE AC DRIVE 175 HP TO 16,000 HP

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Design Characteristics. FlexDrive II. Series

BOSTON GEAR CONTROLLERS. ACE 20 Series 1/8 through 10 HP Adjustable Frequency AC Motor Controllers. MTY (81)

TDE MACNO Spa. AC&DC Drives, Servos and Drive System. AFE converters for Renewable Energies Regenerative (active) power supply (Active Front End)

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

ABB and Baldor Drives. CA769 Effective Date: June, 2015

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC

INTER PLANT STANDARD STEEL INDUSTRY VARIABLE VOLTAGE VARIABLE FREQUENCY SYSTEM (V.V.V.F.) V/F, VECTOR CONTROL / TORQUE CONTROL

PRODUCT OFFERING ADJUSTABLE SPEED DRIVES

vacon nx all in one application manual ac drives Phone: Fax: Web: -

Frequency Inverters. SJ700B Series. Powerful Inverter for General Purpose Use. SJ700B Series

This Chapter contains:

Medium Voltage VFD. Perfect Energy Saving Drive 3kV 200kVA ~ 3,700kVA / 4kV 250kVA ~ 4,700kVA 6kV 400kVA ~ 7,500kVA / 10kV 600kVA ~ 11,000kVA

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

G+ Mini Transition Guide. Product Transition Guide P3 Series 2 to G+ Mini

Intelligent Drive Systems, Worldwide Services SK 700E F 3070 GB

SV2Dx Servo Drives SV200 Servo Drives for DC-Powered Applications

Altivar 28 drive Altivar 28 enclosed drive

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

Design Specifications Operator Keypad Environmental and Operating Conditions

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

TOSVERT TM VF-nC3 Parameter List

GS1 Parameter Summary Detailed Parameter Listings...4 9

Power Regenerative Converter, THYFREC CV240S

Specifications of ASDA A2-E_220V Series

Softstarters. Specification guide. Type PST. Low Voltage Products & Systems

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

Emotron VFX size C Variable Speed Drive

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

The Drive & Control Company. Frequency Converter. VFC 3610 / VFC 5610 Series. Quick Start Guide R Edition 10

MH300 Series / MS300 Series

CTi Automation - Phone: Fax: Web: -

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

Product description. At a glance. Customer benefits

Transcription:

SX (690 V) High performance Vector Control IP54 full range Compact design & Robustness Built-in Filter according to C3 Class Built-in Fuses (From 200 kw) Safety according EN13849-1 and EN62061 standards Load curve control HCB technology (Half controlling Bridge) Logic programmability Pre-maintenance alarms Options flexibitity (I/O s, Fieldbus, PTC/PT, Multiple Pump control, Encoder, Crane control) Communication options (EtherCAT, PROFINET, Modbus, DeviceNet, PROFIBUS, Modbus TCP) 24 VDC control board supply Liquid cooling drive version 12-pulse rectifier option Flexible cable connections & User Friendly wiring connection CE, UL, RoHS, DNV Ratings 690 V Class three-phase 90 to 0 kw System configuration Power supply Panel kit I/O option board Communication option board SX-D Feedback speed option card PTC/PT option card Output coils Brake resistor Motor Ground Overshoot clamp SX (690 V) 1

Specifications Type designation SX series Protection Class: D: IP54 A: IP20 Voltage: 4: 400/480 VAC 6: 690 VAC S X-D6160-EF-OPTIONS Rated Power: 090: 90 kw ~ 1k0: 0 kw Check below table Control type: V: V/Hz F: Direct Torque Control Market: E: Europe E1: Europe IP54 cabinet with front door fan Options available Options Letter (? means no character) Options Letter (? means no character)? = No option Control panel? = Standard control panel (Std.PPU) Option board I = Encoder A = Blank control panel (Blank PPU) position 3 J = PTC/PT K = Extended I/O Built-in EMC filter Built-in brake chopper Standby power supply Safe stop Coated boards Option board position 1 Option board position 2 690 V class? = Standard EMC inside (Category C3) B = IT-Net (filter disconnected from ground)? = No brake chopper or DC-connection included C = Brake chopper & DC-connection included D = Only DC-connection included? = Not included E = Standby power supply included? = Not included F = Safe stop included? = No coating G = Coated boards? = No option H = Crane I/O I = Encoder J = PTC/PT K = Extended I/O? = No option I = Encoder J = PTC/PT K = Extended I/O Option board Fieldbus position 4 Liquid Cooling Standard Marine Cabinet input options Cabinet output options? = No option L = DeviceNet M = PROFIBUS-DP M1 = PROFINET N = RS232/485 O = Ethernet Modbus TCP O1 = EtherCAT? = No Liquid Cooling P = Liquid Cooling? = IEC Q = UL? = No marine option R = Marine option included? = No cabinet input options S = Main switch included T = Main contactor included U = Main switch + contactor included? = No cabinet output options included V = dv/dt filter included W = dv/dt filter + Overshoot clamp included X = Sinusfilter included X1 = All-pole sinus filter included Three-phase: SX-D6@@-E@ 90 110 132 160 200 250 315 355 450 500 600 630 710 800 900 1K0 Motor For HD setting 75 90 110 132 160 200 250 315 315 355 450 500 600 650 710 800 kw *1 For ND setting 90 110 132 160 200 250 315 355 450 500 600 630 710 800 900 0 Max output current (A) 108 131 175 210 252 300 360 450 516 600 720 780 900 1032 1080 1200 Rated output current (A) at HD 72 87 117 140 160 200 240 300 344 400 480 520 576 640 720 800 Rated output current (A) at ND 3 90 109 146 175 200 250 300 375 430 500 600 650 720 800 900 0 Output voltage 0 to Mains supply voltage Max. output frequency 400 Hz Rated input voltage and frequency 3-phase 500 to 690 V, 50/60 Hz Allowable voltage fluctuation +10% to 15% Allowable frequency fluctuation 45 to 65 Hz *1 Based on a standard 4-pole motor for maximum applicable motor output Output characteristics Power supply 2 Frequency inverters

Common specifications Control functions Model number SX- Specifications Control methods V/f control for V type V/f control, Vector control with or without feedback for the F type Output frequency range 0.0 to 400 Hz Frequency tolerance Analogue set value: 1% + 1.5 LSB fsd Digital set value: 0.1 Hz Resolution of frequency set value Analogue set value: 0.03 Hz / 60 Hz (11 bit + sign) Resolution of output frequency 0.1 Hz Frequency set value 10 to +10 V (20 k ), 0 to 20 ma (250 ), frequency setting value (selectable) Starting Torque 150% for Heavy duty, 120% for Normal duty Torque static accuracy <3% in Vector control with feedback <3% in vector control without feedback if speed between 10 and %, <10% at 0 Hz 1 ms for 0% to 90% speed Torque response 5 ms for 90% to % speed (Close and open loop) V/f control 1% Speed Control Accuracy Vector control without feedback 0.1% Vector control with feedback 0.01% Speed Response 0.4% without encoder feedback 0.2% with encoder feedback Torque Limit From Analog input Accel/Decel Time 0.0 to 3600.0 s Braking torque 5% to 10% (% with external braking resistor) Functionality Protection functions Ambient conditions Main Control Functions Motor protection Momentary overcurrent Protection Overload Protection Overvoltage Protection Undervoltage Protection Momentary power loss Ride-Thru Low voltage override function Heatsink Overheat Protection Braking Resistance Overheat Protection Stall prevention Power charge indication Ambient Temperature Ambient humidity Storage temperature PID, sleep function, brake control, torque control (Direct torque control model), Pump/Fan control, Logic functions, virtual connections, overvoltage control, undervoltage override, autoreset, two motor support, Lim Switch, External trip, Preset Speeds, MotPot Up Down, Pump Feedb, Timer, Mot PreMag, Jog, Ext Mot Temp, Loc/Rem, AnIn select, Brk Ackn. Motor overheat protection based on output current or PTC by option board Drive stops when output current exceeds 200% of peak current Drive stops after 1 min at 150% of rated output current (Heavy Duty Rating) Drive stops after 1 min at 120% of rated output current (Normal Duty Rating) (1 min every 10 min) Line Overvoltage: 1120 VDC during more than 10 s for 690 V class Fast Overvoltage: 1220 for 690 VDC 500 for 690 V class (Adjustable by input power supply parameter) Protected by thermistor Hardware short circuit protection Current limit function Power LED remains lit while capacitors are charged 0 to +40 C, up to 45 C with derating 90% RH or less (without condensation) 20 C to +60 C (short-term temperature during transportation) Altitude Up to 0 meters (output derating of 1% per m above 0 m, max. 2000 m) Vibration / Shock According to IEC 600068-2-6, Sinusodial vibrations: 10<f<57 Hz, 0.075 mm, 57<f<150 Hz, 1g Contamination, according to IEC 60721-3-3 Protection Design No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materials. Chemical gases, class 3C2. Solid particles, class 3S2 IP54 enclosure according to the EN 60529, IP20 SX (690 V) 3

R ITTA L Dimensions Standard dimensions IP54 SX-D6250 to D6355-E1F/V SX-D6090 to D6200 22.50 300 150 344,5 335 925 952,50 922,50 2250 2000 150 Ø16(3x) 10 30 Ø9(x6) 314 600 600 SX-D6450 to D6600-E1F/V SX-D6630 to D6800-E1F/V 2250 2000 2250 2000 150 150 900 600 1200 600 4 Frequency inverters

SX-D6900 to D61K0-E1F/V 2250 2000 150 1800 1500 600 Standard dimensions IP20 SX-A6250 to A6355 500 SX-A6450 to A6600 730 1176 1176 450 450 SX (690 V) 5

SX-A6630 to A6800 1 SX-A6900 to A61K0 1365 1176 1176 450 450 Weight and Air flow Model Weight (kg) Air flow SX- SX-D (IP54) SX-A (IP20) (m 3 /hour) 090 to 160 77-800 200 to 355 399 176 1600 450 to 500 563 257 2400 600 to 630 773 352 3200 710 to 1K0 1 514 4800 LCD operator 6 Frequency inverters

Output coils Figure 1 Figure 2 PE c c n2 a n1 b n2 a n1 b Type Fig a b c n2 n1 Fix Weight Connection 473169 00 190 120 235 170 66 M6 8.4 kg 35 mm 2 1 473170 00 190 140 260 170 77 M6 10.2 kg 35 mm 2 473171 00 210 160 180 175 97 M6 13.4 kg M10 2 473172 00 230 170 200 175 95 M6 18.4 kg M10 Specifications Model Rated current Inductance Rated voltage Max carrier Max output frequency 473169 00 90 A 0.1 mh 473170 00 146 A 0.05 mh 6 khz 200 Hz 800 V 473171 00 175 A 0.05 mh 473172 00 275 A 0.032 mh 1.5 khz Hz Max temp Protection Class 40ºC IP00 SX (690 V) 7

Installation Standard connections L1 L2 L3 RFIfilter U V W Motor PE Alternative for potentiometer control Optional DC+ R 1 2 3 4 5 6 7 8 9 10 11 15 16 17 18 19 22 +10 VDC AnIn 1: Reference AnIn 2 AnIn 3 Common AnIn 4 AnOut 1 10 VDC AnOut 2 Common DigOut 1 DigIn 1:RunL* DigOut 2 DigIn 2:RunR* DigIn3 +24 VDC Relay 1 Common DigIn 4 DigIn 5 DigIn 6 Relay 2 DigIn 7 DigIn 8:Reset* DC 12 13 21 14 20 21 31 32 33 41 42 43 Relay 3 51 52 Other options Fieldbus option or PC Option board * Default settings NG_06-F27 8 Frequency inverters

Main circuit Terminal Name Function (signal level) L1, L2, L3 Main circuit power supply input Used to connect line power to the drive. U, V, W Inverter output Used to connect the motor DC, DC+, R DC link connections, Brake resistor The brake resistor must be connected terminals DC+ and R (Terminals are only fitted if the Brake Chopper Option is built-in) PE Safety earth Protected earth Grounding Motor earth Control Circuit Type No. Signal name Function Signal level 8 DigIn 1 RunL (reverse) 9 DigIn 2 RunR (forward) Digital input signals 10 DigIn 3 Off 16 DigIn 4 Off 17 DigIn 5 Off 18 DigIn 6 Off 19 DigIn 7 Off 22 DigIn 8 RESET High > 9 VDC Low < 4 VDC Max 30 VDC Impedance 4.7 kw for < 3.3 VDC 3.6 kw for > 3.3 VDC 11 +24 V +24 VDC supply voltage 15 Common Signal ground 1 +10 V +10 VDC supply voltage Max ma Analog input signals 2 AnIn 1 Process Ref 3 AnIn 2 Off 4 AnIn 3 Off 5 AnIn 4 Off 6 10 V 10 VDC supply voltage 10 to 10 VDC 0 to 20mA Max 30V/30mA Impedance 20 kw Voltage 250 W Current Digital output signals 7 Common Signal ground 20 DigOut 1 Ready 21 DigOut 2 Brake 12 Common Signal ground 31 N/C 1 32 COM 1 33 N/O 1 41 N/C 2 42 COM 2 43 N/O 2 Relay 1 output Trip, active when the VSD is in a TRIP condition. Relay 2 output Run, active when the VSD is started. High > 20 VDC @50 ma > 23 VDC open Low <1 VDC @ 50 ma ma max together with +24VDC 0.1 to 2 A 250 VAC or 42 VDC 51 COM 3 52 N/O 3 Relay 3 output Off Analog output signals 12 Common Signal ground 13 AnOut1 Min speed to max speed 14 AnOut2 0 to max torque 0 to 10 V/0 to 20 ma Max 15V @ 5mA Impedance: 10 W (Voltage) SX (690 V) 9

Ordering information Power supply A Panel kit B I/O option board SX-D C Communication option board D Feedback speed option card E PTC/PT option card G Output coils Motor Ground H F Overshoot clamp Brake resistor SX Specifications IP54 Model IP20 Model Voltage Heavy duty Normal duty Direct torque control V/F Direct torque control V/F 75 kw 72 A 90 kw 90 A SX-D6090-EF SX-D6090-EV 90 kw 87 A 110 kw 109 A SX-D6110-EF SX-D6110-EV 110 kw 117 A 132 kw 146 A SX-D6132-EF SX-D6132-EV 132 kw 140 A 160 kw 175 A SX-D6160-EF SX-D6160-EV 160 kw 160 A 200 kw 200 A SX-D6200-E1F SX-D6200-E1V 200 kw 200 A 250 kw 250 A SX-D6250-E1F SX-D6250-E1V SX-A6250-EF SX-A6250-EV 250 kw 240 A 315 kw 300 A SX-D6315-E1F SX-D6315-E1V SX-A6315-EF SX-A6315-EV 690 V 315 kw 300 A 355 kw 375 A SX-D6355-E1F SX-D6355-E1V SX-A6355-EF SX-A6355-EV 315 kw 344 A 450 kw 430 A SX-D6450-E1F SX-D6450-E1V SX-A6450-EF SX-A6450-EV 355 kw 400 A 500 kw 500 A SX-D6500-E1F SX-D6500-E1V SX-A6500-EF SX-A6500-EV 450 kw 480 A 600 kw 600 A SX-D6600-E1F SX-D6600-E1V SX-A6600-EF SX-A6600-EV 500 kw 520 A 630 kw 650 A SX-D6630-E1F SX-D6630-E1V SX-A6630-EF SX-A6630-EV 600 kw 576 A 710 kw 720 A SX-D6710-E1F SX-D6710-E1V SX-A6710-EF SX-A6710-EV 650 kw 640 A 800 kw 800 A SX-D6800-E1F SX-D6800-E1V SX-A6800-EF SX-A6800-EV 710 kw 720 A 900 kw 900 A SX-D6900-E1F SX-D6900-E1V SX-A6900-EF SX-A6900-EV 800 kw 800 A 0 kw 0 A SX-D61K0-E1F SX-D61K0-E1V SX-A61K0-EF SX-A61K0-EV 10 Frequency inverters

A Panel Kit Type Model Description Function Panel kit SX-OP02-00-E Panel kit Complete panel kit including operator SX-OP02-01-E Blank panel kit Complete panel kit including a blank operator Operator SX-OPHH-00-E Handheld control panel Complete handheld control panel SX-OP01-00-E Digital operator Inverter digital operator SX-OP01-11-E Blank operator Blank operator B I/O option board Model Description Function 01-3876-01 Additional I/O option Provides 3 extra relay outputs and 3 additional digital inputs 01-3876-07 Crane option Dedicated option board for crane application, including additional I/O and functions C Communication option board Type Model Description Function 01-3876-04 RS232/485 MODBUS RTU serial communication by RS232 or RS485 interface with galvanic isolation 01-3876-05 PROFIBUS-DP Used for operating the inverter through PROFIBUS-DP communication with the host controller. 01-3876-06 DeviceNet Used for operating the inverter through DeviceNet communication with the host controller. 01-3876-09 Modbus/TCP, Ethernet Used for operating the inverter through Modbus/TCP communication with the host controller. 01-3876-10 EtherCAT Used for operating the inverter through EtherCAT communication with the host controller. 01-3876-11 PROFINET (1-port) Communication option board 01-3876-12 PROFINET (2-ports) D Encoder feedback option card E PTC/PT option card Used for operating the inverter through PROFINET communication with the host controller. Model Description Function 01-3876-03 Encoder option Used for connection of the actual motor speed via encoder. Up to khz with TTL and HTL incremental encoders with 5/24 V power supply Model Description Function 01-3876-08 Thermal protection Allows to connect a motor thermistor to the inverter F Braking chopper and braking resistor All inverter sizes could be fitted with an optional built-in brake chopper from factory but is not possible to install it later. The choice of the resistor depends on the application switch-on duration and duty-cycle Following tables describes the activation level of the built-in braking chopper and the minimum resistor that could be used depending on the input voltage. 600V Type Rmin for different input votlage ( 500 to 525 VAC 550 to 600 VAC 660 to 690 VAC SX-D6090-EF 4.9 5.7 6.5 SX-D6110-EF 4.9 5.7 6.5 SX-D6132-EF 4.9 5.7 6.5 SX-D6160-EF 4.9 5.7 6.5 SX-D6200-EF 2 4.9 2 5.7 2 6.5 SX-D6250-EF 2 4.9 2 5.7 2 6.5 SX-D6315-EF 2 4.9 2 5.7 2 6.5 SX-D6355-EF 2 4.9 2 5.7 2 6.5 SX-D6450-EF 3 4.9 3 5.7 3 5.7 SX-D6500-EF 3 4.9 3 5.7 3 5.7 SX-D6600-EF 4 4.9 4 5.7 4 5.7 SX-D6630-EF 4 4.9 4 5.7 4 5.7 SX-D6710-EF 6 4.9 6 5.7 6 5.7 SX-D6800-EF 6 4.9 6 5.7 6 5.7 SX-D6900-EF 6 4.9 6 5.7 6 5.7 SX-D61K0-EF 6 4.9 6 5.7 6 5.7 Supply voltage (VAC) Built-in brake chopper trigger level (VDC) 500 to 525 860 550 to 600 0 660 to 690 1150 SX (690 V) 11

G Output coils Output coils above SX-D6160-E should be order from factory as they should be installed inside of the cabinet Voltage Inverter model Model Rated current Inductance Rated Voltage Max carrier Max output frequency SX-D6090-EF 473169 00 90 A 0.1 mh 6 khz 200 Hz 690 V SX-D6110-EF SX-D6132-EF 473170 00 146 A 0.05 mh 800 V 6 khz 200 Hz SX-D6160-EF 473171 00 175 A 0.05 mh 6 khz 200 Hz Max temp 40ºC H Overshoot clamp Only two types of overshoot clamps could be order for after mounting Computer software Model Inverter Function 52163 SX-6090 to SX-6160 Together with the output coils, the overshoot clamp restricts the voltage and the dv/dt on the motor winding. Inverters must be ordered including the option DC+/DC connectors. 52220 SX-6200 to SX-61K0 Together with the output coils, the overshoot clamp restricts the voltage and the dv/dt on the motor winding. Doesn t require the DC+/DC option. Types Model Description Installation CX-Drive Computer software Configuration and monitoring software tool Software CX-One Computer software Configuration and monitoring software tool Saver Computer software Software tool for Energy Saving calculation ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. I125E-EN-04B In the interest of product improvement, specifications are subject to change without notice. 12 Frequency inverters