Wiking Ship Hybrid Cable Application Hybrid cable for shipboard applications DATA ELEMENT Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T IEEE 802.5 16 MB; ISDN; FDDI; ATM Standards DATA ELEMENT EN 50173-1; EN 50288-10-1 ISO/IEC 11801; IEC 61156-5; FO ELEMENT EN 187 000; IEC 60794-2; IEC 60794-2-20; ISO/IEC 11801; EN 50 173-1 Due to constructional circumstances, cables elements will be longer than the overall length of the hybrid cable. Flame resistance DATA ELEMENT LSHF-FR(LSFROH): IEC 60754-2; IEC 61034; IEC 60332-1; IEC 60332-3-24 FO ELEMENT LSHF-FR (FRNC): IEC 60332-1-2; IEC 60332-3-24; IEC 60754-1; IEC 60754-2; IEC 61034 HYBRID CABLE LSHF IEC 60332-1-2; IEC 60754-1; IEC 60754-2; IEC 61034 Page 1 of 6
Wiking Mechanical properties Bending radius 250 mm Temperature range during operation -20 C to + 60 C Max pulling force during installation 0 C to + 50 C 1.500 N Construction Hybrid Cable Central Element Outer Layer Wrapping Filler made of LSOH Draka Data cable Draka Mini break-out cable with 8 fibres, glass yarns and FireRes sheath, waterblocked. VDE: U-VQ(ZN) H and Twisted with Fillers made of Polypropylene PET Foil + Kevlar Braid Sheath LSOH, orange Ø28.6 mm Printing SPEZIALHYBRID V-VI-C WIKING KABEL + 2x SM BendBright XS G.657.A2 + <batch number> <meter marking> m Page 2 of 6
Wiking Construction Data Element Conductor Insulation Twisting Cable lay up Pair screen Overall screen Bare copper wire Ø 0.62 mm (AWG22/1) PE, Ø 1.5 mm 2 cores to the pair 4 pairs Al-laminated plastic foil around each pair Copper braid, tinned Sheath Halogen free, fire retardant sheathing material; LSHF-FR, yellow RAL 1021 Ø 8.25 Printing UC1500 SUPER SCREEN 22 CATEGORY 7 S/FTP 4P IEC 61156-5 LSHF-FR <batch number> <element number> Electrical Properties Data Element at 20 C DC loop resistance 128 Ω/km Resistance unbalance 2% Insulation resistance (500 V) 5000 MΩxkm Capacitance at 800 Hz Nom. 43 nf/km Capacitance unbalance (pair to ground) 1500 pf/km Mean Characteristic impedance @ 100 MHz 100 ± 5 Ω Nominal velocity of propagation 79% Propagation delay 450 ns/100 m Delay skew 15 ns/100 m Transfer impedance bei 1 MHz 5 mω /m bei 10 MHz 5 mω /m Grade 1 bei 30 MHz 10 mω /m Coupling attenuation 85 db Type 1 Segregation classification acc. EN 50174-2 c Page 3 of 6
Wiking Electrical data (nominal) acc. to Cat.7 (at 20 C) F Attenuation NEXT PS-NEXT ACR PS-ACR ACRF PS- ACRF Return loss (MHZ) (db/100m) (db) (db) (db/100m) (db/100m) (db/100m) (db/100m) (db) 1.0 2,1 100 97 98 95 105 105-4.0 3,8 100 97 97 94 105 102 27 10.0 5,9 100 97 95 92 97 94 30 16.0 7,5 100 97 93 90 93 90 30 20.0 8,4 100 97 92 89 91 88 30 31.2 10,5 100 97 90 87 87 84 30 62.5 15,0 100 97 86 83 81 78 30 100.0 19,1 100 97 83 80 77 74 30 125.0 21,5 95 92 75 72 75 72 26 155.5 24,1 94 91 72 69 73 70 26 175.0 25,7 93 90 70 67 72 69 25 200.0 27,6 92 89 67 64 71 68 25 250.0 31,1 90 87 62 59 69 66 24 300.0 34,3 89 86 58 55 67 64 24 400.0 40,1 87 84 48 45 64 61 23 500.0 45,3 85 82 40 37 61 58 22 Page 4 of 6
Wiking Construction FO Element Fibre 2-24 TB9 tightly buffered fibres 900 m 50 m Fibre colour code 1 Red SM BendBright XS G.657.A2 Water blocking Strength member 2 Green SM BendBright XS G.657.A2 3 Blue MM MaxCap-BB-OM4 4 Yellow MM MaxCap-BB-OM4 5 White MM MaxCap-BB-OM4 6 Grey MM MaxCap-BB-OM4 7 Brown MM MaxCap-BB-OM4 8 Violet MM MaxCap-BB-OM4 Swellable tread and tape Low fuzz glass yarns Sheath colour Grey, RAL 7037 Sheath LSHF-FR fire retardant, UV stabilised, EN 50290-2-27 Printing I/O DI D LSHF-FR TB 2 SM7B + 6 OM4B <Item No>05<batch number><meter mark> m Physical properties FO Element Attribute IEC Limits 60794-1-2 Method Fibre count - 8 Nominal diameter [mm] - 6.6 Nominal weight [kg/km] - 48 Maximum installation load [N] E1 680 Permanent tensile strength [N] E1 340 Crush (compressive strength) E3 2000 [N/100 mm] Crush (compressive strength) E3 750 (mandrel/plate)[n] Impact [J] E4 10 Torsion E7 5 cycles 1 turn Flexing E8 1000 cycles Kink E10 The cables do not form a kink when a loop is drawn together to a diameter 12 times the cable nominal diameter Minimum bending radius (0.2 E11 50 db/ ± 5 turn) [mm] Cable bend at low temperature E11A No cracks or damage at -20 C Temperature range F1 Installation Operation Storage Water penetration F5 No water on free end Heat of combustion [MJ/km] [kwh/m] -20 C to 60 C -40 C to 70 C -40 C to 70 C - 765 0.21 Page 5 of 6
Wiking Product order data Product code Cable type Outer diameter Delivery length Weight Copper content Tensile force mm m kg/km N 60041178 Ship Hybrid DL 58 28.6 480 740 224 1500 Storage inside PRYSMIAN GROUP 2014, All Rights Reserved All sizes and values without tolerances are reference values. Specifications are for product as supplied by Prysmian Group: any modification or alteration afterwards of product may give different result. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed to be correct at the time of issue. Prysmian Group reserves the right to amend this specification without prior notice. This specification is not contractually valid unless specifically authorised by Prysmian Group. Page 6 of 6