REGULATED DC POWER SUPPLY OPERATION MANUAL

Similar documents
DC POWER SUPPLY AX-3003L-3 AX-3005L-3. Users manual

MULTI-OUTPUT DC REGULATED POWER SUPPLY

FUNCTION GENERATOR OPERATION MANUAL

Pen-type DIGITAL MULTITESTER

SPECIFICATIONS for SPEAKER TEST OSCILLATOR Model OG-484

Model 1737 Dual Range DC Power Supply

USER MANUAL VIVALDI MZ550A. Distribution Mixer Amplifier

TEST & MEASURING INSTRUMENT CATALOG

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

P5201 Universal Programmable Transmitters with Galvanic Isolation

POWER ANALYZER OPERATION MANUAL. Model : DW-6090A

Random & Sinusoidal Jitter Injector. Main Unit Operation Manual

DSSIU-6-1U-V. Features VOM:

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

True RMS Bench Multimeters 2831E and 5491B

ET-3888 True RMS Clamp Meter. User Manual

TORKEL 900-series Battery Load Unit

Printing Humidity/Temperature Meter

SOLDERING TESTER TM-200. Thank you for buying Soldering Tester TM-200. Please read this Owner's Operation Manual before using your soldering tester.

DSSIU-6-1U. Dedicated 6-channel system interface unit for ultra-stable, high precision fluxgate technology DS series current transducers.

PM 6669 High-Precision Frequency Counter Specifications

T 1000 PLUS Secondary Injection Relay Test Set

TORKEL 900-series Battery Load Unit

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

Agilent E3633A and E3634A DC Power Supplies

Model 4007DDS. 7 MHz Sweep Function Generator

VC835 DIGTAL MULTIMETER Operation Manual

OPERATOR S INSTRUCTION MANUAL

LIGHT TRANSMITTER OPERATION MANUAL. 4 to 20 ma. Model : TR-LXT1A4

True RMS. AUTO RANGE MULTIMETER CAT III-1000 V category, Auto range, REL, Capacitance Hz, Duty, ACV, ACA, DCV, DCA, Ohms

1. BP4620 SPECIFICATIONS

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

SCOPE TRM 25 TRM 25+ Transformer Winding Resistance Meter. The most advanced Transformer Winding Resistance Meter injects up to 25A DC...

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

METRAVI. Table of Contents

PowerBar 4 Manual SAFETY NOTES WARNING! IMPORTANT:

10-CH Digital Thermometer Module

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

USB Multifunction Arbitrary Waveform Generator AWG2300. User Guide

True RMS Bench Multimeters 2831E and 5491B

ADAE portable X ray machine Operation manual

Manual Electric resistance tester PCE-MO 2001

Agilent E3631A Triple Output DC Power Supply

Manatronics 110V / 100 Amp Load

10-CH, 100 ks/s Digitizer Module

Manatronics 48V / 300 Amp Load

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

USER MANUAL FOR VISIBLE SPECTROPHOTOMETER

Particle / Dust Sensor Module

Part No. Z , IB Operation Manual. Pseudo Voice Generator KSG3600

AM/FM SYNTHESIZER TUNER DT-920. TOA Corporation OPERATING INSTRUCTIONS

CPE 100L DIGITAL LOGIC DESIGN I DESIGN LABORATORY LABORATORY 1 LAB SAFETY QUIZ & LAB EQUIPMENT USE TUTORIAL UNIVERSITY OF NEVADA, LAS VEGAS GOALS:

POWER AMPLIFIER. Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes CLIP SIGNAL TEMP PROTECTION POWER

Pen Multimeter. Model

PH METER OPERATION MANUAL. Model : PH-208

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

Earth 2/3 MI 2126 Instruction Manual Version 1.0, Code No

Operating Manual. Model Channel. DC Signal Conditioner Amplifier

PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS

Model 4402B. Ultra-Pure Sinewave Oscillator 1Hz to 110kHz Typical Distortion of % Serial No. Operating Manual

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

TEGAM, INC. SINGLE/DUAL CHANNEL HIGH VOLTAGE AMPLIFIER MODEL 2340/2350. Instruction Manual PN# CD Publication Date: June 2006 REV.

Advanced Test Equipment Rentals ATEC (2832)

True RMS Bench Multimeter 5492B

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

DPAfour125, DPAfour250 AMPLIFIERS. Operating Manual

2000 A DCA/ACA CLAMP + DMM,

M302RM OPERATING MANUAL

SAFETY PRECAUTIONS: Before use, read the following safety precautions

DC Electronic Loads 8500 Series

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Programmable DC Electronic Load

Pulse Amplifier DIV 20 Instruction Manual 03/2016

General Specifications

DC Resistance Meters 2840 Series

Dawson DDM190. Digital Multimeter User s Manual

True RMS Bench Multimeter 5492B

RT-5005/5006/5007/5008

Battery Analyzers BA6010 Series

DC Electronic Loads 8500 series

XES-M50 Operating Instructions

MODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division

USER MANUAL. Goldmund TELOS 390 INTEGRATED AMPLIFIER

DIGITAL MULTIMETER OPERATING INSTRUCTIONS MODEL CDM-35. Part No

LAB-AUTO AUTORANGING DC POWER SUPPLY

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

High-Reliability DC Power Supplies PAN-A Series

Variable-switching Regulated DC Power Supplies PAS Series

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Signal Input and Trigger

Operation manual. Thanks very much for purchasing this. cutter/plotter. To ensure you make best use of your machine,

PIECAL 211 Automated RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

CPE 310L EMBEDDED SYSTEM DESIGN LABORATORY

Transcription:

REGULATED DC POWER SUPPLY OPERATION MANUAL

ACCESSORIES: Power Cord 1pc User s Manual 1pc Fuse 1pc CAUTION: 1 If there is no problem with the line power and CV indicator dose not light after power on, the fuse probably was broken. Power off and disconnect the power cord, and change the fuse. 2 When working in Constant Voltage state,if output voltage lower than what was preset and CC indicator lights, the instrument automatically turn to Constant Current state. You must check the load or increase the output current. 3 When working in Constant Current state, if output current lower than what was preset and CV indicator lights, the instrument automatically turn to Constant Voltage state. You must check the load or increase the output voltage. INDEX 1. Introduction (2) 2. Model type (3) 3. Specifications (4) 4. Front panel & operations (5) 5. Front panel......(6) 6. Operation.....(7) 7. Accessories & Maintenance...(8) 4 When the instrument is unstable in Constant Voltage state, Probably the line voltage is under 90% of the rated value. If the problem is not caused by the line voltage, contact your nearest dealer. 8 1

INTRODUCTION 300 series power supply is a newly developed model with high stability and accuracy. It has over-current, over-voltage, over-heat functions(overall output protection).its unique block-like structure makes it easily to be extended from single channel to multi-channel. It is an ideal instrument for R&D departments, colleges and factories. Operation Connection of output ports: Port No.2 and No.3 is in floating mode, you can get different polarity voltage by connecting positive or negative terminal on both sides to the ground-terminal in the middle. Port No.1 is a fixed output. Its negative terminal had been grounded internally. Voltage Setting: Adjust voltage knob to get desired voltage. Current Setting: Turn current control knob CCW to get a small value of current, short cut output port, adjust current knob to get a desired value. Serial Usage: Select series mode with Buttons (5), Use + end of port no.3 and - end of port no.2 as output terminal. Output voltage is the summation of channel A and channel B. Parallel Usage: Select series mode with Buttons (5), Use either one of output terminals of two channels, a doubled current can be acquired. 2 7

Functions of the controls on front panel (1)(2) 3 digit LED display of voltage and current. (3)(4) CV and CC indicators. If the current (calculated by Ohm s law) through the load is lower than the preset current value of the power supply, CV indicator lights, the power supply is working in Constant Voltage status. Otherwise, CC indicator lights, the power supply is in Constant Current status. And the actual current though the load is limited to the preset current value. (5) Independent/Series/Parallel Controls. When the power supply is set in series mode, two channels are connected serially. Voltage of Channel A will follow that of Channel B. Then a pair of same value and different polarity voltage is acquired, and you can get a doubled voltage from positive port of CH-B and negative port of CH-A. When the power supply is set in parallel mode, two channels are connected parallel. And you can get a doubled current from either port of two channels. (6) Power switch. (7)(8) Voltage adjustment. If in tracking state, the switches of channel A are not available. (9)(10) Current adjustment, to set constant current value. (11) Output port No.1, fixed 5V/3A output. (12) Output port No.2, it is controlled by switch (7) and (9). (13) Output port No.3, it is controlled by switch (8) and (10). 6 MODELS Model Voltage 0~30V 0~2 A Current 0~3A 0~5A 0~10A 0~20A Fixed output 5V/3A Dual output 302A 303A 305A 3010A 3020A 302B 302B 302B 302DII 303DII 305DII 3010DII Input Voltage: 240VAC±10%50/60HZ Rated Output Power: 60W X 2 = 120w(2A) 90W X 2 =180w(3A) 150W X 2 =300w(5A) Operating Ambient: Temperature:0-40 Humidity: 90%RH Storage Ambient: Temperature:.20-80 Humidity: 80%RH 3 Single output

SPECIFICATIONS Model: Dual output models Single output models Variable Output: Output Voltage: 0~30V continuously adjustable Output Current: 0~ specified value continuously adjustable Source Regulation: 0.01% +3mV Load Regulation: 0.01% +3mV Ripple & Noise: 1mVrms Tracing Error: 0.5% +10mV --------- Display: 4 sets of 3 digit LED 2 sets of 3 digit LED Display Error: 0.5% + 1digit Fixed Output Output Voltage: 5V, 3.3(only for models of single channel) Output Current: 3A Source Regulation: 5mV Load Regulation: 15mV Ripple & Noise: 2mVrms Others: Line Power Supply 240V±10% Dimension: 240X150X270(mm) 120X150X270(mm) Weight: Approx. 10kg Approx. 5kg FRONT PANEL & OPERATION For 2A, 3A and 5A models For 10A, 20A models 4 5