Standard TOP Monitoring System Conditions

Similar documents
Standard COM Communications

NORMES DE FIABILITÉ DE LA NERC (VERSION ANGLAISE)

Standard VAR Voltage and Reactive Control

VAR Generator Operation for Maintaining Network Voltage Schedules

VAR Generator Operation for Maintaining Network Voltage Schedules

VAR Generator Operation for Maintaining Network Voltage Schedules

VAR Generator Operation for Maintaining Network Voltage Schedules

5. Effective Date: On the first day of the first quarter, after applicable regulatory approval.

Standard BAL Frequency Response and Frequency Bias Setting

A. Introduction. VAR Voltage and Reactive Control

THIS DOCUMENT IS RETIRED BY FERC EFFECTIVE SEPTEMBR 5, 2018.

VAR Voltage and Reactive Control

VAR Generator Operation for Maintaining Network Voltage Schedules

Standard VAR-002-2b(X) Generator Operation for Maintaining Network Voltage Schedules. 45-day Formal Comment Period with Initial Ballot June July 2014

Standard VAR-002-2b(X) Generator Operation for Maintaining Network Voltage Schedules

Standard VAR-002-2b(X) Generator Operation for Maintaining Network Voltage Schedules

Final ballot January BOT adoption February 2015

Standard PRC Coordination of Generating Unit or Plant Voltage Regulating Controls with Generating Unit or Plant Capabilities and Protection

Standard PRC Generator Frequency and Voltage Protective Relay Settings. A. Introduction

Final ballot January BOT adoption February 2015

VAR Voltage and Reactive Control. A. Introduction

Standard PRC Generator Frequency and Voltage Protective Relay Settings. A. Introduction. See the Implementation Plan for PRC

Standard PRC Coordination of Generating Unit or Plant Capabilities, Voltage Regulating Controls, and Protection

Standard Development Timeline

Standard VAR b Generator Operation for Maintaining Network Voltage Schedules

Standard PRC Coordination of Generating Unit or Plant Capabilities, Voltage Regulating Controls, and Protection

August 25, Please contact the undersigned if you have any questions concerning this filing.

Standard MOD Area Interchange Methodology

August 25, 2017 VIA ELECTRONIC FILING

generation greater than 75 MVA (gross aggregate nameplate rating) Generation in the ERCOT Interconnection with the following characteristics:

WECC Standard VAR-002-WECC-2 Automatic Voltage Regulators

Standard Development Timeline

PRC Generator Relay Loadability. A. Introduction 1. Title: Generator Relay Loadability 2. Number: PRC-025-1

PRC Generator Relay Loadability. A. Introduction 1. Title: Generator Relay Loadability 2. Number: PRC-025-1

Standard MOD Verification of Models and Data for Generator Excitation Control System or Plant Volt/Var Control Functions

Standard MOD Verification of Models and Data for Generator Excitation Control Sys tem or Plant Volt/Var Control Functions

(Circuits Subject to Requirements R1 R5) Generator Owner with load-responsive phase protection systems as described in

Standard Development Timeline

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION ) )

Standard BAL b Automatic Generation Control

Standard BAL b3 Automatic GenerationBalancing Authority Control DRAFT

Standard BAL b Automatic Generation Control

Cover Sheet. Technical Justification Retirement of WECC Regional Reliability Standard VAR-002-WECC-2 Automatic Voltage Regulators (AVR)

Standard Development Timeline

May 30, Errata to Implementation Plan for the Revised Definition of Remedial Action Scheme Docket No. RM15-13-_

Implementation Plan Project Modifications to PRC Reliability Standard PRC-025-2

PRC Disturbance Monitoring and Reporting Requirements

Definition of Bulk Electric System Phase 2

NORTH AMERICAN ELECTRIC RELIABILITY COUNCIL

Implementation Plan Project Balancing Authority Reliability-based Controls - Reserves

4.2.1 Generators Transformers Transmission lines. 5. Background:

Standard Development Timeline

Standard BAL-005-0b Automatic Generation Control

VAR Outreach Presentation

September 19, Errata to Implementation Plan for the Revised Definition of Remedial Action Scheme

BEFORE THE ALBERTA ELECTRIC SYSTEM OPERATOR

Voltage and Reactive Procedures CMP-VAR-01

At generating sites with 1200MW or greater of installed generating capacity.

Alberta Reliability Standard Frequency Response and Frequency Bias Setting BAL-003-AB-1.1

Transmission Availability Data System Phase II Final Report

SECTION SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES

Project Balancing Authority Reliability-based Controls Reliability Standard BAL-005-1

Transmission Availability Data System (TADS) DATA REPORTING INSTRUCTION MANUAL

FACILITY RATINGS METHOD TABLE OF CONTENTS

EUROPEAN COMPLIANCE PROCESSES (post RfG Implementation) CONTENTS. (This contents page does not form part of the Grid Code) Paragraph No/Title

Reliability Guideline Integrating Reporting ACE with the NERC Reliability Standards

Document C-29. Procedures for System Modeling: Data Requirements & Facility Ratings. January 5 th, 2016 TFSS Revisions Clean Open Process Posting

Overview of Metering Assurance in the Capacity Market

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section SCADA Technical and Operating Requirements

FCC Test Report. Report No.: AGC FE08 MODEL NAME : TH 9800,TH 9800D,TH 7800,TH 7900 CLIENT : TYT ELECTRONICS CO., LTD

Ch. 813 INTERACTIVE GAMING ADVERTISEMENTS CHAPTER 813. INTERACTIVE GAMING ADVERTISEMENTS, PROMOTIONS AND TOURNAMENTS TEMPORARY REGULATIONS

1 SERVICE DESCRIPTION

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENT 1073 PRECAST CONCRETE CERTIFICATION PROGRAM JULY 20, 2018

Transmission Availability Data System (TADS) Data Reporting Instruction Manual

Rule 21 Working Group 3.

WFPS1 WIND FARM POWER STATION GRID CODE PROVISIONS

Implementation Plan Project Alignment of Terms

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section SCADA Technical and Operating Requirements

Procedure for ERO Support of Frequency Response and Frequency Bias Setting Standard. Event Selection Process

Calculating and Using Reporting ACE in a Tie Line Bias Control Program

PRC Compliance Using Bitronics 70 Series Recorders

Appendix A. NERC Transmission Vegetation Management Plan. F:\P2000\ \A89\VMP\Final_VMP_ docx

GUIDELINES FOR THE APPLICATION FOR PUBLIC RADIOCOMMUNICATIONS SERVICE (PRS) LICENCES

Summary of Relaying Reviews Reporting

RISE OF THE HUDDLE SPACE

Functional Specification Revision History

NPCC Regional Reliability Reference Directory # 12. Underfrequency Load Shedding Program Requirements

DIVISION 1 - GENERAL REQUIREMENTS SECTION SUBMITTALS

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications

Date Description Revision May 19, 2008

Recently, the SS38 Working Group on Inter-Area Dynamic Analysis completed two study reports on behalf of the UFLS Regional Standard Drafting Team.

TECHNICAL SPECIFICATIONS AND OPERATING PROTOCOLS AND PROCEDURES FOR INTERCONNECTION OF GENERATION FACILITIES NOT SUBJECT TO FERC JURISDICTION

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications

Procedure for Obtaining Verification of a Stormwater Manufactured Treatment Device from New Jersey Corporation for Advanced Technology

A. Action Submittals: Written and graphic information that requires Engineer's responsive action.

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

Canadian Technology Accreditation Criteria (CTAC) POWER SYSTEMS ENGINEERING TECHNOLOGY - TECHNICIAN Technology Accreditation Canada (TAC)

SULTANATE OF OMAN METERING AND DATA EXCHANGE CODE

CHAPTER ELECTRIC AND MAGNETIC FIELDS

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements

Transcription:

A. Introduction 1. Title: Monitoring System Conditions 2. Number: TOP-006-2 3. Purpose: To ensure critical reliability parameters are monitored in real-time. 4. Applicability 4.1. Transmission Operators. 4.2. Balancing Authorities. 4.3. Generator Operators. 4.4. Reliability Coordinators. 5. Proposed Effective Date: In those jurisdictions where no regulatory approval is required, the standard shall become effective on the latter of either April 1, 2009 or the first day of the first calendar quarter, three months after BOT adoption. In those jurisdictions where regulatory approval is required, the standard shall become effective on the latter of either April 1, 2009 or the first day of the first calendar quarter, three months after applicable regulatory approval. B. Requirements R1. Each Transmission Operator and Balancing Authority shall know the status of all generation and transmission resources available for use. R1.1. R1.2. Each Generator Operator shall inform its Host Balancing Authority and the Transmission Operator of all generation resources available for use. Each Transmission Operator and Balancing Authority shall inform the Reliability Coordinator and other affected Balancing Authorities and Transmission Operators of all generation and transmission resources available for use. R2. Each Reliability Coordinator, Transmission Operator, and Balancing Authority shall monitor applicable transmission line status, real and reactive power flows, voltage, load-tap-changer settings, and status of rotating and static reactive resources. R3. Each Reliability Coordinator, Transmission Operator, and Balancing Authority shall provide appropriate technical information concerning protective relays to their operating personnel. R4. Each Transmission Operator, and Balancing Authority shall have information, including weather forecasts and past load patterns, available to predict the system s near-term load pattern. R5. Each Reliability Coordinator, Transmission Operator, and Balancing Authority shall use monitoring equipment to bring to the attention of operating personnel important deviations in operating conditions and to indicate, if appropriate, the need for corrective action. R6. Each Balancing Authority and Transmission Operator shall use sufficient metering of suitable range, accuracy and sampling rate (if applicable) to ensure accurate and timely monitoring of operating conditions under both normal and emergency situations. R7. Each Reliability Coordinator, Transmission Operator, and Balancing Authority shall monitor system frequency. C. Measures Page 1 of 6

M1. The Generator Operator shall have and provide upon request evidence that could include but is not limited to, operator logs, voice recordings, electronic communications, or other equivalent evidence that will be used to confirm that it informed its Host Balancing Authority and Transmission Operator of all generation resources available for use. (Requirement 1.1) M2. Each Transmission Operator and Balancing Authority shall have and provide upon request evidence that could include but is not limited to, operator logs, voice recordings, electronic communications, or other equivalent evidence that will be used to confirm that it informed its Reliability Coordinator and other affected Balancing Authorities and Transmission Operators of all generation and transmission resources available for use. (Requirement 1.2) M3. Each Reliability Coordinator, Transmission Operator and Balancing Authority shall have and provide upon request evidence that could include but is not limited to, computer printouts or other equivalent evidence that will be used to confirm that it monitored each of the applicable items listed in Requirement 2. M4. Each Transmission Operator and Balancing Authority shall have and provide upon request evidence that could include but is not limited to, printouts, training documents, description documents or other equivalent evidence that will be used to confirm that it has weather forecasts and past load patterns, available to predict the system s near-term load pattern. (Requirement 4) M5. Each Reliability Coordinator, Transmission Operator and Balancing Authority shall have and provide upon request evidence that could include but is not limited to, a description of its EMS alarm capability, training documents, or other equivalent evidence that will be used to confirm that important deviations in operating conditions and the need for corrective actions will be brought to the attention of its operators. (Requirement 5) M6. Each Reliability Coordinator, Transmission Operator and Balancing Authority shall have and provide upon request evidence that could include but is not limited to, a list of the frequency monitoring points available to the shift-operators or other equivalent evidence that will be used to confirm that it monitors system frequency. (Requirement 7) D. Compliance 1. Compliance Monitoring Process 1.1. Compliance Monitoring Responsibility Regional Reliability Organizations shall be responsible for compliance monitoring. 1.2. Compliance Monitoring and Reset Time Frame One or more of the following methods will be used to assess compliance: - Self-certification (Conducted annually with submission according to schedule.) - Spot Check Audits (Conducted anytime with up to 30 days notice given to prepare.) - Periodic Audit (Conducted once every three years according to schedule.) - Triggered Investigations (Notification of an investigation must be made within 60 days of an event or complaint of noncompliance. The entity will have up to 30 days to prepare for the investigation. An entity may request an extension of the preparation period and the extension will be considered by the Compliance Monitor on a case-by-case basis.) The Performance-Reset Period shall be 12 months from the last finding of noncompliance. Page 2 of 6

1.3. Data Retention Each Generator Operator shall keep 90 days of historical data (evidence) for Measure 1. Each Transmission Operator and Balancing Authority shall keep 90 days of historical data (evidence) for Measure 2. Each Reliability Coordinator, Transmission Operator and Balancing Authority shall have current documents as evidence for Measure 3, 5 and 6. Each Transmission Operator and Balancing Authority shall have current documents as evidence of compliance to Measure 4. If an entity is found non-compliant the entity shall keep information related to the noncompliance until found compliant or for two years plus the current year, whichever is longer. Evidence used as part of a triggered investigation shall be retained by the entity being investigated for one year from the date that the investigation is closed, as determined by the Compliance Monitor, The Compliance Monitor shall keep the last periodic audit report and all supporting compliance data 1.4. Additional Compliance Information None. Page 3 of 6

2. Violation Severity Levels: R# Lower Moderate High Severe R1 N/A N/A N/A know the status of all generation and transmission resources available for use, even though said information was reported by the Generator Operator, Transmission Operator, or Balancing Authority. R1.1 N/A N/A N/A The Generator Operator failed to inform its Host Balancing Authority and the Transmission Operator of all generation resources available for use. R1.2 N/A N/A N/A inform the Reliability Coordinator and other affected Balancing Authorities and Transmission Operators of all generation and transmission resources available for use. R2 monitor 3% or less of applicable transmission line status, real and reactive power flows, voltage, load-tap-changer settings, and status of rotating and static reactive resources. monitor more than 3% up to (and including) 6% of applicable transmission line status, real and reactive power flows, voltage, load-tap-changer settings, and status of rotating and static reactive resources. monitor more than 6% up to (and including) 9% of applicable transmission line status, real and reactive power flows, voltage, load-tap-changer settings, and status of rotating and static reactive resources. R3 N/A N/A provide appropriate technical information concerning protective relays to all of its operating personnel monitor more than 9% of applicable transmission line status, real and reactive power flows, voltage, load-tap-changer settings, and status of rotating and static reactive resources. provide appropriate technical information concerning protective relays to any of its operating personnel. Page 4 of 6

R# Lower Moderate High Severe R4 N/A N/A The responsible entity has either weather forecasts or past load patterns, available to predict the system s near-term load pattern, but not both. R5 N/A N/A The responsible entity used monitoring equipment to bring to the attention of operating personnel important deviations in operating conditions, but does not have indication of the need for corrective action. have both weather forecasts and past load patterns, available to predict the system s near-term load pattern. use monitoring equipment to bring to the attention of operating personnel important deviations in operating conditions. R6 N/A N/A N/A use sufficient metering of suitable range, accuracy and sampling rate (if applicable) to ensure accurate and timely monitoring of operating conditions under both normal and emergency situations. R7 N/A N/A N/A monitor system frequency. Page 5 of 6

E. Regional Variances None identified. Version History Version Date Action Change Tracking 0 April 1, 2005 Effective Date New 0 August 8, 2005 Removed Proposed from Effective Date Errata 1 November 1, 2006 Adopted by Board of Trustees 2 Modified R4 Modified M4 Modified Data Retention for M4 Replaced Levels of Non-compliance with the Feb 28, BOT approved Violation Severity Levels (VSLs) 2 October 17, 2008 Adopted by NERC Board of Trustees 2 March 17, 2011 Order issued by FERC approving TOP-006-2 (approval effective 5/23/11) 2 February 28, 2014 Updated VSLs based on June 24, 2013 approval. Revised Revised Page 6 of 6