Super Revo. Surgical Technique. Super Revo Shoulder Fixation System. The Ideal Fixation Device For Rotator Cuff Repair. Self-drilling, titanium anchor

Similar documents
ARTHROSCOPIC ROTATOR CUFF REPAIR SURGICAL TECHNIQUE. The following techniques are described by Vernon J. Cooley, M.D.

Double Row Rotator Cuff Repair. Surgical Protocol by Frank Bonnarens, M.D.

Double Row Rotator Cuff Repair. Surgical Protocol by Frank Bonnarens, M.D.

The OPUS AutoCuff System for Rotator Cuff Repair

VERSALOK. Suture Anchor. Rotator Cuff Repair Surgical Technique

Dr. S.D. Gerber Double Row Method Surgical Technique

LabraLock P for Labrum Repair, LabraFix System. The Reinforcement Technique Guide

Rotator Cuff Repair ICONN Answer PEEK Suture Anchor 4.75/5.5. Surgical Protocol by Geoffrey Connor, 4.75/5.5 MD of D1 Sports Medicine

Arthroscopic Protector Meniscus Suturing Surgical Techniques

BioPlug 5.2 SPS Secure Portal System

Champion Instrumentation. Shoulder Repair Made Simpler

Knotless SutureTak Instability Repair. Surgical Technique

Suture anchors for VeterinarY use

Bio-Compression. Arthrex. Screw System

Arthrex. Bio-Compression. Screw System. Knee OCD. Hand, Wrist & Elbow. Foot & Ankle

Product Pamphlet. Parcus Medical s Value Proposition Program is designed to reduce cost per case by:

Arthroscopic Rotator Cuff Repair

Knotless Bankart Repair Using the Labral SwiveLock. and FiberStick. Surgical Technique. Labral SwiveLock

Ankle Fracture System. Surgical Technique STRENGTH FROM WITHIN

Technique Guide. Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

Small Plate and Screw System SURGICAL TECHNIQUE

Anterior Cervical Plate SURGICAL TECHNIQUE GUIDE. Surgeon Driven Innovation

MTP Set SURGICAL TECHNIQUE

High polish finish. Complete line of biters, tissue graspers

ISO Plate SURGICAL TECHNIQUE

5th Metatarsal Fracture System Surgical Technique

TORNIER MAXLOCK EXTREME. Clavicle Plating System SURGICAL TECHNIQUE

Techniques of the hand tie and instrument tie

MaxTorque. surgical technique. Cannulated Screw System. Foot & Ankle. OrthoHelix Technology

HCS 2.4/3.0. The countersinkable compression screw.

The Percutaneous Reduction Forceps Technique Guide

Technique Guide. 7.0 mm Cannulated Screws. Part of the Synthes Cannulated Screw System.

Universal Humeral Nail

ORTHOLINK. 2 - Hole Wedge Osteotomy Plate SURGICAL TECHNIQUE

Mecron Cannulated Screws

Technique Guide. 4.5 mm Cannulated Screws. Part of the Synthes Cannulated Screw System.

Lag Screw Device TECHNIQUE GUIDE. Indicated for symphyseal fracture fixation of the mandible. Instruments and implants approved by the AO Foundation

ExpresSew II. Intuition redefined.

Orthopedic Bone Nail System Universal Humeral Nail

Revolutionizing Orthopaedic Surgery. Braided Composite Suture

6.5 mm and 7.3 mm Cannulated Screws Technique Guide

Integra. Capture Screw System SURGICAL TECHNIQUE

MTP Fusion Surgical Technique

Surgical Technique 1

Surgical Technique. Acutrak Headless Compression Screw System

Technique Guide. Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

Surgical Technique Guide

EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2011/04

Digital Compression Screw

TwinFix Surgical Protocol. 3.2mm Cannulated Compression Screw System

A free-extending two part cannulated screw that will elongate with growth. SURGICAL TECHNIQUE

PARS Achilles Jig System

Technique Guide. 2.4/2.7 mm Locking Tarsal Plates. Talus Plate, Navicular Plate and Cuboid Plate.

Technique Guide. Cable System. For Orthopaedic Trauma Surgery.

Fibula Plating System

MatrixMANDIBLE Preformed Reconstruction Plates. Preshaped to the mandibular anatomy.

Instruments for Removing DePuy Synthes Screws. Screw Removal Set

Zimmer Natural Nail System

Prostar XL Percutaneous Vascular Surgical Device

ACCS Anterior Cervical Compression System TECHNIQUE GUIDE

CHARLOTTE. Multi-Use Compression Screw

Zimmer Natural Nail System

RTI TECHNOLOGIES, INC.

DISTAL RADIUS PLATES 3.5 mm / ANGULARLY STABLE. Distal radius plates 3,5 mm / angularly stable. Locking bone screws. Cortical bone screw

MIS TECHNOLOGY GUIDE READ PRODUCT INSERT THOROUGHLY BEFORE USE

Basic Instructions. The Ring: Fill the shuttle with thread from a ball DMC or Coats 20, but DO NOT CUT from the ball.

OPERATIVE TECHNIQUE RIVAL BITE HEADED CANNULATED AND HEADLESS COMPRESSION SCREWS. foot & ankle applications

Integra. Stainless Headed Compression Screw System SURGICAL TECHNIQUE

Surgical Technique. Customer Service:

Integra. Tibio Talo Calcaneus Plate SURGICAL TECHNIQUE

7.0 mm Cannulated Screws

Cervical Solutions. Lineum OCT. Spine System. Surgical Technique Guide

University of Alabama at Birmingham. ObGyn Residency. Laparoscopy Training Lab PGY 1-4. Individual Pelvic Trainer Tasks

4.5/6.7 mm Low Profile Screw System Surgical Technique. 4.5/6.7 mm Low Profile Screw System

Back to health. Back to work. Back to life.

PFW 6875 Installation Guide Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d Installation, Installatie gids

DART-FIRE. Small Screw System SURGICAL TECHNIQUE

Zimmer Natural Nail System

3.5 mm Cannulated Screw Technique Guide

OPERATIVE TECHNIQUE RIVAL VIEW PLATING SYSTEM. foot & ankle reconstruction procedures

POLYAXIAL SPINE SYSTEM SURGICAL TECHNIQUE

ACLP Anterior Cervical Locking Plate System TECHNIQUE GUIDE

DART-FIRE. Small Screw System SURGICAL TECHNIQUE

MEDIALMAX System SURGICAL TECHNIQUE

Cerclage Passer. For minimally invasive application of cerclage cables.

REPAIR INSTRUCTIONS: CABLE

Proximal Humerus System 3.5

Suturing simplified. The first and only reusable, articulating, curved needle driver.

Peanut Growth Control Plating System. Surgical Technique

BioDrive Micro Screw System

OsteoBridge IKA Intramedullary Knee Arthrodesis Fixation System. From the «BioBall Company» OsteoBridge Family

Treace Medical Concepts Plating System

The use of sutures and ligatures is an integral part of surgical procedures. Being proficient in suturing and ligating will not only make your

The Titanium Cannulated Lateral Entry Femoral Recon Nail. Expert nailing system with radiolucent instrumentation.

Technique Guide MTP Arthrodesis System

Instructions for Use. LCP Locking Compression Plate. Combine without Compromise.

Technique Chart. DHS/DCS One-Step Insertion Wrench. For use with DHS/DCS One-Step Lag Screws.

Ascent. Posterior Occipital Cervico-Thoracic (POCT) System

Aesculap Spine S 4 Spinal System. Instrumentation Guide

Reflex Hybrid System Overview

Transcription:

Super Revo Shoulder Fixation System The Ideal Fixation Device For Rotator Cuff Repair Super Revo Surgical Technique INCREASED Strength and Suture Management Self-drilling, titanium anchor Independent Suture Sliding (ISS ) Eyelet Design Preloaded with #2 Sutures Optimized thread pitch for increased pullout strength This product contains Dyneema Purity. Dyneema Purity is a registered trademark of Royal DSM N.V.

Two sutures provide versatile suture placement Depth Marking Tapered Core Diameter Cutting Tip Suture Retention Cleat

Super Revo Shoulder Fixation System Surgical Technique INTRODUCTION The ConMed Linvatec 5mm Super Revo Suture Anchor offers a simple and reproducible technique for arthroscopic or a mini-open rotator cuff repair. The cutting tip requires no pre-drilling and the anchor is pre-threaded with two #2 strands of braided polyester suture or two #2 strands of HiFi Suture. The potential pitfalls of suture management are avoided with the Independent Suture Sliding (I.S.S. ) Eyelet design. The sutures slide with relative ease, which allows for sliding knots to be tied without the worry of locking the other strand and minimizes suture abrasion. In addition, the Super Revo Suture Anchor is designed for improved pullout strength. The surgeon must have an excellent understanding of the technique and must practice suture passing and knot tying before attempting the operation. The following outline highlights the important steps in a typical rotator cuff repair. ConMed Linvatec will be happy to provide more comprehensive videotape instructions. You may also use an Alex The Shoulder Professor shoulder model to practice these techniques prior to surgery. Information can be obtained by calling your local ConMed Linvatec representative or Customer Service at (800) 237-0169. The following techniques are described by Stephen J. Snyder, MD, Van Nuys, CA

Super Revo Shoulder Fixation System Surgical Technique 1 2 3 Step 1 The rotator cuff tear is carefully evaluated with an arthroscope on both the articular and bursal sides, and the frayed edges of the cuff are debrided. The best view of the rotator cuff is usually the 50 yard line view with the arthroscope in a lateral subacromial portal which is located at the center point of the rotator cuff tear. Step 2 A Spectrum Crescent Suture Hook with a Shuttle Relay or a Blitz suture passer is used to perform a side-to-side repair of longitudinal tears in the rotator cuff tendon. Step 3 After passing the curved suture hook across the tear, a strong, long lasting suture is carried across the tear and the suture limbs tied together. 7 8 9 Step 7 The anchor security is tested by pulling on the suture strands. Step 8 The arthroscope can be positioned in the anterior or posterior portal but most often the overall visualization is best from the lateral acromial portal. Step 9 A crochet hook or suture retrieval forceps is inserted through the anterior portal (ConMed Linvatec 6mm operating cannula) and retrieves the strand of the green suture that exits the anchor closest to the cuff*. The retriever must pass behind (medial to) the suture limbs. * Prior to insertion the anchor and suture can be disengaged from the driver. A marking pen can be used to color one side of the suture limbs. This simple maneuver helps to differentiate between the two suture limbs during suture retrieval.

Designed in conjunction with Stephen J. Snyder, MD 4 5 6 Step 4 The bone is lightly decorticated at the anatomical neck of the humerus, adjacent to the articular cartilage, using a high speed bur and/or shaver. The rotator cuff is mobilized to minimize tension on the repair. Step 5 A small puncture wound is created adjacent to the lateral border of the acromion. The 5mm Super Revo anchor, preloaded with two strands of #2 suture, is inserted directly through the percutaneous puncture wound (no cannula is needed to insert the anchor). The posterior anchor is usually inserted first. The anchor is directed to enter the bone in a medial direction below the subchondral bone at approximately a 45 angle. Step 6 The Super Revo anchor is inserted into the bone until the seating ring on the driver is just below the surface. The vertical orientation mark (solid or dashed line which indicates the direction the anchor eyelet is facing) is aligned toward the cuff edge. This ensures that the suture passes in a direct line from the eyelet to the cuff without forming a twist. 10 11 12 Step 10 A Spectrum Crescent Suture Hook is inserted into the posterior cannula and through the bursal side of the posterior edge of the torn rotator cuff 5mm posterior to the anchor. The Shuttle Relay suture passer is sent through the hook and retrieved with a grasping forceps out the anterior cannula. Care must be taken to insure that the grasping forceps follows the same path as the green suture when retrieving the Shuttle Relay to avoid causing twists in the strands. Step 11 The green suture strand is loaded into the eyelet of the Shuttle Relay suture passer outside the anterior cannula. The suture is then carried through the cuff from the articular side to the bursal side by withdrawing the opposite end of the suture passer out the posterior cannula. Step 12 A crochet hook is used to retrieve the other limb of green suture into the posterior cannula. A switching stick is then inserted through the posterior cannula and the cannula is removed from the joint.

Super Revo Shoulder Fixation System Surgical Technique 13 14 15 Step 13 The cannula is reinserted over the switching stick leaving the sutures outside the cannula where they will be less likely to be tangled during stitching with the white sutures. Step 14 A crochet hook or suture retrieval forceps is used to retrieve the limb of white suture that exits the anchor eyelet closest to the rotator cuff. The suture is pulled through the anterior cannula. Step 15 The Spectrum Suture Hook is passed through the torn rotator cuff from top to bottom approximately 5mm anterior to the anchor site. If a crescent suture hook is used again, it may be inserted through the posterior cannula. If a more angled suture hook is used, the posterior cannula can be removed and the hook passed directly through the portal without a cannula. The Shuttle Relay suture passer is passed through the hook and retrieved with a grasping forceps through the anterior cannula. 14 15 16 Step 14a ALTERNATIVE METHOD (Modified Caspari Suture Punch): A crochet hook is used to retrieve the limb of white suture that is closest to the cuff. The suture is pulled out through the lateral cannula. Step 15a Modified Caspari Suture Punch Continued: With the scope viewing from the anterior portal, a modified Caspari Suture Punch can be inserted through a 6mm ClearFlex Cannula in the lateral portal to pass a Shuttle Relay suture passer from the bottom to top through the cuff. The suture passer is carried out the posterior cannula with a grasping forceps. Step 16a Modified Caspari Suture Punch Continued: The eyelet of the Shuttle Relay suture passer is loaded with the suture outside the lateral cannula and carried through the cuff from bottom to top by pulling on the opposite end.

Designed in conjunction with Stephen J. Snyder, MD 16 18 19 Step 16 The white suture strand is loaded into the eyelet of the Shuttle Relay suture passer outside the anterior cannula. The suture is carried through the cuff from the articular side to the bursal side by withdrawing the opposite end of the suture passer out the posterior portal. Step 18 The ring handled knot pusher is threaded on to the green suture exiting the top of the cuff. It is passed into the joint to ensure there are no twists or obstructing soft tissue. The green and white suture limbs associated with the posterior anchor are first tied using a knot of choice. The second anchor is placed in a similar fashion, suture limbs passed, and tied down. Step 19 The arthroscope may be moved to the posterior cannula for visualization. The third (anterior) anchor is placed in the same fashion and suture limbs passed through the cuff, usually suturing from the anterior portal. 17 20 Super Revo Diameter Drill Hole Size Suture 5.0mm N/A Two strands of #2 braided polyester suture. C6141 Suture Two strands of #2 Hi-Fi High Strength Suture. C6140H Pullout 101 lbs, 451 N 2 Material Titanium Insertion Type Self-drilling Step 17 The posterior cannula is reinserted and the remaining white suture limb is retrieved using a crochet hook or suture retrieval forceps. Step 20 The illustration of the final repair shows three Super Revo anchors in place. Each anchor has two fixation points through the rotator cuff oriented 45 from the anchor. Notice the final side-to-side repair. At the completion of the repair, the torn end of the rotator cuff is tightly opposed to the bone to promote strong rotator cuff tendon healing.

Super Revo Shoulder Fixation System Implants Description Cat. No. Super Revo Suture Anchor, 5.0mm, pre-loaded on a disposable driver... C6140 (pre-threaded with two #2 braided polyester sutures-green and white) Super Revo Suture Anchor, 5.0mm, pre-loaded on a disposable driver... C6140H (pre-threaded with two #2 Hi-Fi * sutures white and white with blue stripe) Super Revo Suture Anchor, 5.0mm, Anchor Only... C6141 (pre-threaded with two #2 braided polyester sutures-green and white) Super Revo Suture Anchor, 5.0mm, Anchor Only... C6141H (pre-threaded with two #2 Hi-Fi sutures, white and white with blue stripes) Super Revo Driver, Reusable... C6142 Super Revo Remover Guide... C6143 Spectrum II Instrument Set: Suture Hook Handle...C6350 Suture Hook, 45 Right Curve...C6360 Suture Hook, 45 Left Curve...C6361 Suture Hook, 60 Right Curve...C6362 Suture Hook, 60 Left Curve...C6363 Suture Hook, 90 Right Curve...C6364 Suture Hook, 90 Left Curve...C6365 Suture Hook, Right Corkscrew...C6366 Suture Hook, Left Corkscrew...C6367 Suture Hook, Straight...C6368 Suture Hook, Small Crescent...C6369 Suture Hook, Medium Crescent...C6370 Suture Hook, Large Crescent...C6371 Suture Hook, 45 Right Curve...C6380 Suture Hook, 45 Left Curve...C6381 Suture Hook, 60 Right Curve...C6382 Suture Hook, 60 Left Curve...C6383 Suture Hook, Straight...C6384 Suture Hook, Small Crescent...C6385 Suture Hook, Medium Crescent...C6386 Suture Hook, Large Crescent...C6387 Spectrum II Accessories: Spectrum II Sterilization Tray...C6355 Spectrum II Roller Wheel Replacement Kit...C6356 (includes 2 wheels, 2 axles, 1 screw and Allen Wrench) * This product contains Dyneema Purity. Dyneema Purity is a registered trademark of Royal DSM N.V. Accessories Suture Saver Kit...C6180 Crocket Hook...C6005 Knot Pusher...C6112 Katana... GU1009 Grasping Forceps... 11.1001 Suture Retrieval Forceps... 16.1018 Dry Doc Cannula with Obturator, 8.0mm x 75mm, Translucent Red... C7367 Dry Doc Cannula with Obturator, 8.0mm x 85mm, Translucent Yellow... C7368 2009 Linvatec Corporation, a subsidiary of ConMed Corporation, 06/2009, CST 3018 Rev. 6