TECHNICAL SPECIFICATION SHEET

Similar documents
The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

Type 297, High-Voltage Mica Capacitors Corona-free Mica Coupling Capacitors for Medium-Voltage PDA s

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description:

Capacitive voltage transformers

3. COMBINED TRANSFORMERS Oil-paper insulation

POWER TRANSFORMERS CATALOGUE

Capacitive voltage transformers

The Isolator/Surge Protector (ISP)

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

The Isolator/Surge Protector (ISP)

4. CAPACITIVE VOLTAGE TRANSFORMERS AND COUPLING CAPACITORS Oil-paper insulation

Transformer Factory Testing

AC Dielectric Test Sets

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

700 Series AC Dielectric Test Sets

KFS. Flap-type flow meter. Design and range of application

MODEL: DAST-20. Telemetering System

Insulation Testers and Earth Ground Testers

Technical features table for miniature circuit-breakers SH 200 Series

MODEL: 47LV. Digital Panel Meters 47 Series

Distribution/Substation Transformer

Kotron Model 82 CE RF Level Transmitter

DEVELOPMENT OF A TEST PROTOCOL FOR A 15 KV CLASS SOLID-STATE CURRENT LIMITER

Arc Suppression Coils

Resistive capacitive voltage divider

Compressors, Chillers & Condensers

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

USING DAMPED AC VOLTAGES

RF-CAPACITANCE (Coat-Shield)Level Limit Switch

Introduction. Centrado leading-edge transformer. Introduction

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

Your safety first! This is the reason why our manual begins with the following guidelines:

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

700 Series AC Dielectric Test Sets

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

CAST RESIN DRY TRANSFORMER

TIDALFLUX 2300 F Technical Datasheet

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

RF Capacitance Level Controls

1 INTRODUCTION ORDER CODE / INFORMATION

EI HIGH VOLTAGE INSULATION TESTING POLICY

ECP HV INSULATION TESTING

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:

Type EP Series. Wirewound Anti-Surge Resistor. Key Features. Characteristics Electrical. Power Derating Curve

Resistive capacitive voltage divider

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

Substation Preventive Maintenance

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

RF Capacitance Level Controls

StatiVolt. Inverter UPS Systems. Features. Contents

Technical Specification

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

Level Lance Model 5100

Mobrey Series 9700 Hydrostatic level transmitter

OPTIFLUX 5000 Technical Datasheet

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser, OMICRON electronics Corp. USA

1507/1503. Insulation Testers. Technical Data. Features and benefits:

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

Cast resin transformers HARMONY TM

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Power Processor - Series 700F 10KVA to 150KVA

Operating manual. TruTool N 500 (1A1) english

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

User s Guide. 400A AC/DC Clamp Meter. Model MA220

ECP HV INSULATION TESTING

IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

1587/1577 Insulation Multimeters

Type SSVT oil-filled station service voltage transformer Auxiliary power from high voltage transmission lines

Energy Division. Bowthorpe LV/MV Surge Arresters

Diagnostic testing of cast resin transformers

MODEL: M2DYS SEN TRONIC AG

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

SET Installation and Operating Instructions. Level switch for two sensors

Device Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

WATERFLUX 3000 Quick Start

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

All the standards referred to the most current issue, including all amendment supplements. as of the date of the bid.

Continuous C-III Series Units. ) 2ms Rectangular Wave 40 to 530 J Operating Ambient Temperature Range (T A

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

Earthing of Electrical Devices and Safety

Inductive Voltage Transformers. Types VEOT and VEOS

PIRANHA 3 (3-phase, Power Conditioning Voltage Regulator)

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

FILTERS & SUPPRESSION

200Amp AC Clamp Meter + NCV Model MA250

Sales: Technical: Fax:

Končar TMS - Bushing monitoring

AXIS P32 VE/-LVE Series. Repainting Instructions

HI-Physix Laboratory, L-83, Sector-1, DSIDC Industrial Area, Bawana, Delhi. Discipline Electronics Testing Issue Date

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Transcription:

TECHNICAL SPECIFICATION SHEET ZORC is a unique high frequency transient over voltage surge suppressor for the protection of motors, transformers and generators from steep wave-front, short rise-time, high magnitude, spikes, surges and other transient voltages, generated by switching and certain other sources. The protective characteristics of ZORC provide comprehensive insulation co-ordination with both the CIGRë and IEEE motor impulse voltage withstand characteristics at all practical surge magnitudes and rise times. Specification 3 Phase standard ZORC Unit 3.3 4.16 6.6 7.2 11 12.5 13.8 Rated Voltage (L-L) 3.3 4.16 6.6 7.2 11 12.5 13.8 Voltage Range 2.2-3.3 3.3 4.2 4.2-6.6 6.6-7.2 7.9-11 11-12.5 12.8-13.8 Rated Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Rated per µf 0.2 0.2 0.2 0.2 0.2 M3-0.1 P3 0.2 % -5 / +10-5 / +10-5 / +10-5 / +10-5 / +10-5 / +10-5 / +10 Ω 30 30 30 30 30 30 30 Insulator BIL C -20 / +50-20 / +50-20 / +50-20 / +50-20 / +50-20 / +50-20 / +50 F -4 / 122-4 / 122-4 / 122-4 / 122-4 / 122-4 / 122-4 / 122 TH(V)D % 8 8 8 8 8 8 8 Dielectric type All-film All-film All-film All-film All-film All-film All-film 0.1 Installation Bushing type kg 16 16 16 16 19 19 19 lb 35.27 35.27 35.27 35.27 41.88 41.88 41.88 mm 343x435x138 343x435x138 343x435x138 343x435x138 0x480x105 0x480x105 0x480x105 13.5 x 16.14 Min 16mm² to 25mm² (to earth) / 0.0248 in² to 0.0387 in² (to ground) Ceramic Three Nm 20 ft lb 14.75 Stainless steel (3 Cr 12) with thickness of 1.6mm / 0.063 es Connection Product codes M3-3 P3-3 M3-4.16 P3-4.16 M3-6 P3-6 YN M3-7.2 P3-7.2 M3-11 P3-11 M3-12.5 P3-12.5 M3-13.8

Specification 1 Phase standard ZORC Unit 3.3 6.6 11 12.5 13.8 15 Rated Voltage (L-L) 3.3 6.6 11 12.5 13.8 15 Voltage Range 2.2-3.3 4.2-6.6 7.9-11 11-12.5 12.8-13.8 14-15 Rated Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 Rated per µf 0.1 0.1 0.2 M1-0.1 P1 0.2 0.1 0.15 % -5 / +10-5 / +10-5 / +10-5 / +10-5 / +10-5 / +10 Ω 30 30 30 30 30 30 Insulator BIL NA NA C -20 / +50-20 / +50-20 / +50-20 / +50-20 / +50-20 / +50 F -4 / 122-4 / 122-4 / 122-4 / 122-4 / 122-4 / 122 TH(V)D % 8 8 8 8 8 8 Dielectric type All-film All-film All-film All-film All-film All-film NA NA Installation kg 2 2 15 15 15 18 lb 33 33 33 39.6 mm 116x177x72 116x177x72 0x480x105 0x480x105 0x480x105 340x515x105 4.56 x 6.97 x 2.83 4.56 x 6.97 x 2.83 13.38 x 20.27 Min 16mm² to 25mm² (to earth) / 0.0248 in² to 0.0387 in² (to ground) Bushing type D-116 D-116 Ceramic Ceramic Ceramic Ceramic Nm NA NA 20 20 20 20 ft lb NA NA 14.75 14.75 14.75 14.75 One Stainless steel (3 Cr 12) with thickness of 1.6mm / 0.063 es Product codes M1-3 M1-6 M1-11 P1-11 M1-12.5 P1-12.5 M1-13.8 M1-15

Specification 3 Phase compact ZORC Unit 3.3 4.16 6.6 LVZ400 LVZ550 LVZ690 LVZ1000 Rated Voltage (L-L) 3.3 4.16 6.6 0.4 0.55 0.69 1 Voltage Range 2.2-3.3 3.3 4.2 6.6 0.38-0.4 0.46-0.55 0.58-0.69 0.8-1 Rated Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Rated per µf 0.1 0.1 0.1 0.5 0.5 0.5 0.5 % -5 / +10-5 / +10-5 / +10-5 / +10-5 / +10-5 / +10-5 / +10 Ω 30 30 30 22 22 22 22 Insulator BIL NA NA NA NA C -20 / +50-20 / +50-20 / +50-20 / +50-20 / +50-20 / +50-20 / +50 F -4 / 122-4 / 122-4 / 122-4 / 122-4 / 122-4 / 122-4 / 122 TH(V)D % 5 5 5 5 5 5 5 Dielectric type All-film All-film All-film All-film All-film All-film All-film Installation NA NA NA NA kg 5.5 5.5 5.5 3.2 3.2 3.2 3.2 lb 12.12 12.12 12.12 7.05 7.05 7.05 7.05 mm Min 16mm² to 25mm² (to earth) / 0.0248 in² to 0.0387 in² (to ground) Min 4mm² to 16mm² (to earth) /0.0062 in² to 0.025 in² (to ground) Bushing type Ceramic Terminal Housing Three NA NA NA NA Nm 20 NA NA NA NA ft lb 14.75 NA NA NA NA None Paint primer Stainless steel (3 Cr 12) with thickness of 1.6mm / 0.063 es Aerofin Epoxy Primer Beige (180-0039) Thanacryl Polyurethane Enamel (700-Line) Mild Steel (Commercial quality) Powder Coated Grey 631 Connection YN YN Product codes M3C-3 M3C- 4.16 M3C-6 LVZ400 LVZ550 LVZ690 LVZ1000

Specification 1 Phase ZORC RC Suppressor Unit 22 25 33 36 40 Rated Voltage (L-L) 22 25 33 36 40 Voltage Range 18-22 22.5-25 25.5-33 33.5-36 36.5-40 Rated Frequency Hz 50/60 50/60 50/60 50/60 50/60 Rated per µf 0.2 0.2 0.2 0.2 0.2 % -5 / +10-5 / +10-5 / +10-5 / +10-5 / +10 Ω 30 30 30 30 30 Insulator BIL C -25 / +50-25 / +50-25 / +50-25 / +50-25 / +50 F -4 / 122-4 / 122-4 / 122-4 / 122-4 / 122 TH(V)D % 8 8 8 8 8 Dielectric type All-film All-film All-film All-film All-film Installation Bushing type kg 20 47 47 47 47 lb 44 103.6 103.6 103.6 103.6 mm 343 x 655 433 x 1310 433 x 1310 433 x 1310 433 x 1310 x 117 x 433 x 433 x 433 x 433 13.5 x 25.78 17.04x51.57 17.04x51.57 17.04x51.57 17.04x51.57 x 4.6 x 17.04 x 17.04 x 17.04 x 17.04 Min 16mm² to 25mm² (to earth) / 0.0248 in² to 0.0387 in² (to ground) Ceramic One Nm 20 ft lb 14.75 Stainless steel (3 Cr 12) with thickness of 1.6mm / 0.063 es Configuration One unit Two units (cans) per values above are consolidated for 2 cans Product codes M1-22 M1-25 M1-33 M1-36 M1-40

Standards Quality Management System Overall manufacturing compliance ISO 9001: 8 (Dekra Certification) IEC 60871-1: 5 / ANSI, IEEE 18 / NEMA CP-1 / VDE 0560 part 410 / CIGRé 13.02 Testing Manufacturing tests Field tests Each ZORC surge suppressor is routine tested prior to dispatch. Test certificates are available. Check for obvious physical damage (broken bushing, leaking impregnate, bulging tank, etc.) Measure the capacitance from each to earth and check that it is within 10% of nominal (0.1 or 0.2µF, as stamped on the ZORC rating plate). Use a hand-held capacitance meter or apply a known low voltage (e.g. 230V ac) between each and earth, measure the currents, and calculate the capacitance. With the ZORC line connections bonded together, and using a dc cable test set, test between line and earth for 10 seconds. Confirm there are no dielectric breakdowns or audible discharges. Additional Considerations Maintenance Inspection A ZORC is maintenance-free, requiring only periodic cleaning of bushings in contaminated areas. Equipment should be inspected periodically for failure or leaks. This check can be made after de-energising and following Safety Instruction, Shock Hazard detailed elsewhere in this document. The use of hoses in the vicinity of an open ZORC installation must be avoided. Testing can be carried out once a year. Inspect the ZORC for dirty, broken or chipped bushings. Physical damage to the casing. Earth & the leads. The casing earth and leads should not be corroded. Inspect casing for any bulging. (Needs to be removed from service immediately). Inspect very carefully for oil leaks. (Needs to be removed from service immediately). General Hazardous location certification Life expectancy Warranty Further documentation available Class 1 Div 2 Certification of ExN (Non Sparking) available on 3.3/6.6/11 Units, Temp Classes T1-T5, SABS 970-1971 20 years on all models 12 month factory warranty ZORC Operating Manual ZORC Instructions for Safe Use Faradol 810 MSDS