Monitoring voltages of 3-phase 4 wires with a single unit

Similar documents
THT TYPE. Interface unit with built-in DO module FEATURES

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

Model Number Structure

DPDT+DPST-NO MM4KP-JD MM4XKP-JD

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Ordering Information. Ratchet Relay G4Q. Model Number Legend

Solid-state Timer H3DS

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

Classification Enclosure rating Contact form Contact material

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

48 Series - Relay interface modules A. Features

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

Electronic Circuit Breaker ESS20-0..

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

3. Contact Form A: SPST-NO

Modular equipment. Presentation, standards. Standard contactors TeSys GC

SPST-NO SPDT DPST-NO DPDT

NS..S contactor relays - with spring terminals AC operated

Analog Timer TTL Series

Multi Function Timer with Free power, Compact size W38 H42mm

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Solid-state Twin Timer

Protection components

Ordering Information. Power Relay G2A. Model Number Legend Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control

38 Series - Relay interface modules A

38 Series - Relay interface modules A

PART NUMBERING SYSTEM

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

Timers GE1A. GE1A Series ON Delay Timers Single Function

Protection components

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

Details on the New G2RS

Time relay RXKA 1. (xx jpg) RXKA 1

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

Electronic Circuit Breaker with reset input ESS20-1..

2 or 4 pole changeover contact Plug-in/Faston 187

2. Terminal Shape P: PCB terminals B: Screw terminals T: Quick-connect terminals (#250 terminal)

Model Number Structure

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

16A POWER RELAY FOR MICRO WAVE OVEN

G2RL-1A G2RL-1 G2RL-2A G2RL-2

TJ TYPE. How to order of terminal blocks TJ XF Basic type Pole Rail TJX A29 FEATURES SPECIFICATIONS (RATINGS, PERFORMANCE)

27/04/2015

SPST-NO SPDT DPST-NO DPDT

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

DIN48 SIZE ANALOG MULTI-RANGE CYCLIC TWIN TIMERS

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

OMRON MK-I / -S RELAY

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

PART NUMBERING SYSTEM

Surface-mounting Relay

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer

Multi-voltage Multi-function. Wiring diagram (without control signal)

CompoBus/D-type Digital Controller

RXG12BD interface plug-in relay - Zelio RXG - 1C/O standard - 24VDC-10A-with LTB and LED

30 AMP POWER RELAY WITH SPACE SAVING DESIGN

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Electronic Circuit Protector ESX10-T

COMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES. UL File No.: E CSA File No.: LR39291

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Corresponds to breaker size current value. Contributing to space saving by selecting an appropriate size

Self-powered Counter

Relay interface modules A

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

Solid-state Timer H3DE

G5LE. Ordering Information. PCB Relay. A Cubic, Single-pole 10-A Power Relay J MODEL NUMBER LEGEND G5LE PCB Relay G5LE

Timing Mode Supply Voltage Trigger Options Reset Options Outputs Cat. No V AC Power On Power Off. Repeat Cycle OFF-Start

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

PCB Relay. --- G2R-1-SN --- G2R-2-SN LED indicator with test

Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection

Transcription:

VOLTAGE RELAY PTS TYPE High-performance under-voltage relay that activates output when all 3-phase voltages fall below a reference voltage by monitoring voltage on each phase of 4 wires FEATURES Monitoring voltages of 3-phase 4 wires with a single unit The PTS type for monitoring 3-phase 4 wires is newly available in addition to the conventional FVS type that monitors only one phase. The PTS type under-voltage relay monitors all 3-phase voltages to verify that voltages on all phases are lower than a reference voltage. The PTS type incorporates 1a1b output contacts. Operation status LED With the operation monitor LED, you can easily check control power ON/OFF status and monitor voltage. (POWER, UV) Digital switch The digital switch simplifies the reference voltage setting procedure. G17

Voltage indication label (standard accessory) Labels that indicate reference voltage settings are included in the product. If you attach a label after setting a voltage, you can easily confirm the reference voltage. ELECTRONIC DEVICES Control voltage is input from monitor power supply. No additional control power supply is required. Since control voltage is input from the monitor power supply, the relay unit does not need an additional control power supply. The internal relay turns OFF when input voltage falls below 38V regardless of the reference voltage setting. G18 High-performance engineering plastic is used for the storing case. To enhance flame-retardance, high-performance engineering plastic is used for the storing case. (UL94, V-1) SPECIFICATIONSRATINGS, PERFORMANCE Item Rated insulation voltage (Ui) Monitor/control input voltage Max. input value Input impedance Reference voltage Insulated resistance Power-frequency withstand voltage Impulse withstand voltage (Uimp) Noise resistance Vibration resistance Shock resistance Ambient temperature Relative humidity Altitude Power consumption Weight Specification 250V Each phase: 40 to 110V AC 130V (continuous), 250V (instantaneous) 4k or more (when output relay is exited) 40, 50, 60, 70, 80V AC (5 settings) L-A L-L L-A L-L L-A L-L L-L Electric wave noise 10M or more (500V DC Megger tester) 1 10M or more (500V DC Megger tester) 2 2,000V AC for 1 min. 1 2,000V AC for 1 min. 2 ±7kV / 3 times for each pole 1 ±4.5kV / 3 times for each pole 2 ±3kV / 3 times for each pole (between monitor / control input terminals) 150MHz band (5W), 400MHz band (5W) 900MHz band (cellular phone) Static noise Contact discharge: 8kV Air discharge: 15kV Frequency: 16.7Hz Double amplitude: 0.4mm Direction: Forward / backward, right / left, up / down Vibration time: 10min Shock value: 294m/s 2 Number of shocks: 3 times each (forward, backward, right, left, up, down) Performance warranty Operation warranty Recovery warranty 0 to 40 C 10 to 55 C (Allowable for several hours per day) 20 to 60 C 30 to 90% (daily average) 2,000 m max. Approx. 3.5 W (Control power supply: Maximum rating, When output relay is excited) Approx. 220g 1 Between monitor/control input and output contact terminals and mounting rail 2 Between monitor/control input terminals and output contact terminals, and between individual output contact terminals

VOLTAGE RELAY PTS TYPE HOW TO ORDER No. Item Indication Description Basic type Shape code Circuit code Power supply voltage PTS S P AC 40 / 120 8-pin socket type 3-phase 4-wire AC under-voltage monitoring 40 to 120V AC Remarks Applicable to the socket, 8PFA1 (OMRON) Since control voltage is input from monitor power supply, no additional control power supply is required. CONFORMABLE STANDARDS Standard Name Year JEC-174D JEC-2500 B-402 Auxiliary relay for power supply Protection relay for power supply Digital protection relay and protection relay equipment 1987 1979 1997.10 OTHER SPECIFICATIONS Item Set / Reset time Error range Reset dead band Temperature effect Output contact rating Number of output contacts Operational indication color Max. operational voltage Rated current-carrying capacity (Ith) UNDER Power supply indicator Output contact indicator Description 0.5 sec. max. Within ±2V Within +4V Within ±1V / 10 C 380V AC max. 125V DC max. 5A 1a1b Green (during operation) Red (during operation) MAXIMUM SWITCHING CAPACITY OF OUTPUT CONTACT Contact current (V) AC resistance load DC resistance load DC inductive load AC inductive load Contact voltage (V) G19

STANDARD PRODUCTS ELECTRONIC DEVICES Input indicator (Green) Operation indicator (Red) Location of voltage indication label (Attached after setting) Reference voltage setting (Digital switch) Digital switch selection table NP Operation chart UNDER contact (Example: Operating voltage: UNDER=DC50V) Phase A, B, C Reset dead zone (Within +4V) Operation error (Within ±2V) 0.5 sec. max. Output contact operation 0.5 sec. max. SW setting Input: AC Monitor input (constant) : 100V Reference voltage (UNDER) : 50V Connection diagram Monitor / control input A Monitor / control input B Monitor / control input C Monitor / control input N PTS main unit Operation By monitoring input voltage on each phase of AC 3-phase 4 wires, the output contact is switched when all 3-phase voltages fall below a reference voltage. The internal relay has no voltage when input voltage is 38V or lower regardless of the reference voltage setting. The above operation chart is based on a-contact output. In constant monitoring mode, the internal relay is ON. (Terminals 3-4: Open, Terminals 5-6: Closed) When all 3-phase voltages fall below a reference voltage or when the monitor input is lost, the internal relay turns OFF. (Terminals 3-4: Closed, Terminals 5-6: Open) Indicators All 3-phase voltages are 38 V or lower All 3-phase voltages are reference voltage or lower At least one-phase voltage is higher than reference voltage Power supply indicator lamp (Green) Operation indicator lamp (Red) Unlit Lit Lit G20 Unlit Lit Unlit Internal relay No voltage No voltage Excited Terminals 3 4 Terminals 5 6

VOLTAGE RELAY PTS TYPE TECHNICAL DATA REFERENCE VOLTAGE SETTING PROCEDURE Reference voltage (operating voltage) setting By referring to the Digital switch selection table on the side of the relay unit, specify a reference voltage with the digital switch. (Example: To set 70 V AC, turn ON the No. 4 bit.) Digital switch selection table Attached on side of the product body Attaching voltage indication label To indicate the reference voltage specified in step, attach the voltage indication label (included in the product). Be sure to attach this label so that the voltage is not accidentally changed after setting. Before attaching the label, verify that the digital switch setting ting conforms to the selection table on the side of the product body. Voltage indication label Standard accessory included in the product Connecting the relay unit to a socket Connect the relay unit to a specified applicable socket to apply a monitor voltage. G21

ACCESSORIES ELECTRONIC DEVICES Applicable socket (Order unit: 10) Voltage indication label ( Included as standard accessory) 8PFA1 [OMRON] PTS-SP-NP (Order unit: 10) Typical parts list No. Part name Material Remarks Case Plug pin Instructions for handling the product and other information This product is applicable to a 3-phase 4-wire voltage circuit and is not applicable to a 3-phase 3-wire voltage circuit. In applications to other circuits, this product enables monitoring of typical phase voltage of 3-phase 4-wire circuit, and monitoring of single-phase 2-wire voltage. For connection with a PT (transformer), check the capacity of the transformer (including other load). G22 Modified PPE Brass / Tin-plated When setting a voltage, be sure to disconnect the relay unit from the socket, or do not apply a monitor voltage or power supply voltage to the relay unit (to prevent output error). After setting a voltage, be sure to attach the voltage indication label suitable for each state (to prevent erroneous operation and entry of a foreign substance). When you set a reference voltage with the digital switch, do not turn ON multiple bits simultaneously (to prevent output error).