NEXEDGE Type-D Trunking System

Similar documents
NX-700 / 800 NEXEDGE VHF/UHF Digital & FM Analog Mobile

CTI Products. RadioPro IP Gateway. Installation Guide. Document # S For Version 8 Software

Hytera. PD41X Patrol Management System. Installation and Configuration Guide

New Product Release Information. NX-220 / NX-320 NEXEDGE VHF/UHF Digital & FM Portable Transceiver. Vilvoorde 25 February 2011

"Terminal RG-1000" Customer Programming Software. User Guide. August 2016 R4.3

-ability NEXEDGE KENWOOD DIGITAL SYSTEMS

Version SmartPTT Enterprise. Installation and Configuration Guide

Quick Start Guide. RSP-Z2 Dual Channel Analog-IP Interface

Version 9.1 SmartPTT Monitoring

Version 8.8 Linked Capacity Plus. Configuration Guide

Configuration Guide. Version 8.3

WEB I/O. Wireless On/Off Control USER MANUAL

Version 1.0 February Frequently Asked Questions

OPERATING GUIDE OPERATING GUIDE FOR IC-F5060/F6060 SERIES BIIS 1200/MDC 1200 SYSTEM/ LTR /IDAS NXDN OPERATION

Guardian and DL3282 Modem Interface Technical Service Application Note

JEM Radio II Operation Guide. Manual P/N M Victor Place Colorado Springs, Colorado

DMR Radio Authorization Operation Guide

OPERATING GUIDE OPERATING GUIDE FOR IC-F3160/F4160 SERIES BIIS 1200/MDC 1200 SYSTEM/ LTR /IDAS NXDN OPERATION

UCP-Config Program Version: 3.28 HG A

ASTi SYNAPSE Remote Control Guide Document: DOC-01-SYN-RC-1

AW2400iTR USER S MANUAL 2.4 GHz Indoor Wireless Ethernet Radio

INSTRUCTION MANUAL IP REMOTE CONTROL SOFTWARE RS-BA1

XPT Digital Trunking Decentralized and Cost-Effective Digital Trunking Solution

X-BAND REPEATER SPECS FEATURES SIGNALING WARRANTY. Cross Band VHF & UHF. frequencies. 128 channels, 8 zones. LCD with 8 character alphanumeric

Intrinsically Safe & Non-Incendive Two-Way Portable Radios

OPERATING GUIDE OPERATING GUIDE FOR IC-F5060/F6060 SERIES BIIS 1200/MDC 1200 SYSTEM/ LTR /IDAS OPERATION

TurboVUi Solo. User Guide. For Version 6 Software Document # S Please check the accompanying CD for a newer version of this document

INDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3 ST-965 PROGRAMMING SOFTWARE...6

DRG-Series. Digital Radio Gateway. Kenwood NXDN Donor Radio (Tier-2) Interfacing Omnitronics DRG with Kenwood NXDN Donor Digital Radios (Tier-2)

GPSR116 Quick Start Guide

Version 9.1 SmartPTT Enterprise. Installation & Configuration Guide

PYRAMID 915MHZ WIRELESS RF TRANSMITTER & REPEATER USER GUIDE. Table of Contents. Overview Installation Setup Specifications...

XLR PRO Radio Frequency (RF) Modem. Getting Started Guide

TRBOnet Enterprise. Linked Capacity Plus. Deployment Guide. Internet. US Office Neocom Software Jog Road, Suite 202 Delray Beach, FL 33446, USA

MAX Dispatch - Standard

SETTOPSURVEY, S.L. Bofarull 14, Barcelona (Spain) Phone: (+34) Fax: (+34)

Programming Instructions for: Kenwood TK-780, 880, 980, 981 (Version 2) W/ KCT-19 Option Connector For use with: Pyramid Communications Model

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart CONTENTS. Saab TransponderTech AB. Appendices. Project designation. Document title

Version 9.1. Installation & Configuration Guide

SpeedTouch 190. Setup and User s Guide. SIP Gateway. Release R1.0

101 Overview Presentation

TK-780/880 VHF / UHF Trunking / Conventional Mobile Radios

DMR Trunking Pro. Hytera Open Standard DMR Trunking Portfolio

OPERATING GUIDE OPERATING GUIDE FOR IC-F3160/F4160 SERIES BIIS 1200/MDC 1200 SYSTEM/ LTR /IDAS OPERATION

Communications Solutions

-ability NEXEDGE KENWOOD DIGITAL SYSTEMS. Specifications are subject to change without notice, due to advancements in technology.

1 NEXEDGE offers: Conventional

DRG-Series. Digital Radio Gateway. Hytera DMR USB Donor (Tier-2) Digital Radio Supplement

TRBOnet Enterprise. Capacity Plus. Deployment Guide. Internet. US Office Neocom Software Jog Road, Suite 202 Delray Beach, FL 33446, USA

Product Information. DMR Low Tier Digital

PC Tune PC Tune Test Procedures for 5100 Series Portable Radios

CTI Products RadioPro Dispatch User Guide Document # S For Version 8 Software

CTI Products RadioPro Dispatch Demo Installation and Test Drive Document # S For Version 8 Software

GPSR400 Quick Start Guide

TRBOnet Enterprise 2.6 for MOTOTRBO Capacity Plus.

TT-208. User s Manual. 300Mps 5.8 GHz. IP Camera Wireless Transmission Kit

Shenzhen ATC Technology CO.,LTD ATC. A-1 Serial Remote I/O Module. User Manual. V1.13 Edit:2018/01/

AES 7705i MultiNet Receiver System Initial Installation and Setup Guide

DRG-Series. Digital Radio Gateway. Motorola MotoTRBO DMR. Interfacing Omnitronics DRG with Motorola MotoTRBO DMR Digital Radios

8800SX DMR Repeater Test Option 06

3 GHz Carrier Backhaul Radio. Model: AF-3X. Tel: +44 (0) Fax: +44 (0) LINK GPS MGMT DATA DATA

WPE 48N USER MANUAL Version1.1

Two-way Radio for Every Profession

Hytera DMR Conventional Series

TRBOnet Enterprise. IP Site Connect. Deployment Guide. Internet. US Office Neocom Software Jog Road, Suite 202 Delray Beach, FL 33446, USA

TRBOnet Enterprise. Extended Range Direct Mode. Deployment Guide. Internet

AW900xTR USER S MANUAL 900 MHz Outdoor Wireless Ethernet Radio

Networks of any size and topology. System infrastructure monitoring and control. Bridging for different radio networks

AW5802xTP. User s Manual. 5.8 GHz Outdoor Wireless Ethernet Panel. AvaLAN. Industrial-grade, long-range wireless Ethernet systems

NTS-4000-S. NTS-4000-S Installation and Configuration Manual TEL: +44 (0) FAX: +44 (0) galleonsupport.

AW5802xTR. User s Manual. 5.8 GHz Outdoor Wireless Ethernet Radio. AvaLAN. Industrial-grade, long-range wireless Ethernet systems

NXDN DMR. versus. a comparison of protocols JVCKENWOOD USA CORPORATION. D.E. Wingo, Sr. Product Manager WHITE PAPER

LINK GPS MGMT DATA. 4 GHz Licensed Backhaul Radio DATA MGMT GPS. Model: AF-4X LINK

1. INTEROPERABILITY GATEWAY DEVICES

DRG-Series. Digital Radio Gateway. Tait P25 CCDI Tier-2 (TM9400 Series Mobile Radio) Digital Radio Supplement

PaperCut VCA Cash Acceptor Manual

Hytera DMR Conventional Series Release Notes

USER S MANUAL ADDENDUM Matched Pair Bridges

IP controller TRBOnet Swift Agent A002.M1

Introduction to DMR and the DMR Association

Channel processing equipment

Customer Programming Software RG-1000e (CPS RG-1000e) User Guide. October 2017 R2.0

EOS 80D (W) Wireless Function Instruction Manual ENGLISH INSTRUCTION MANUAL

INDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3 ST-965 PROGRAMMING SOFTWARE...6

Quick Start. Precis-BX305. Precise GNSS RTK Board.

APRS multi-function I-GATE Operators manual technical status: June 2014 Version 1.12

Version 9.2. SmartPTT PLUS. Capacity Max Configuration Guide

N E T W O R K UPGRADE SOLUTIONS UPGRADE YOUR MPT NETWORK YOUR WAY

AT-D868UV CodePlug Programming Guide

DIMETRA EXPRESS DATA SHEET DIMETRA EXPRESS

Communications Solutions

LinkAlign-60RPT Set-up and Operation Manual

Ground System Training Department

MOTOBRIDGE Dispatch Application Overview

SafeMobile Radio Configuration

SIP Trunking Service Configuration Guide for XO

MOTOTRBO R1.8 Training Overview

-ab ilit y NEXEDGE DIGITAL SYSTEMS. Configurations for NEXEDGE Systems. NXDN Type-C Trunking Generation 2. NXDN Type-D Trunking

TK-2312E TK-3312E. New Product Release Information. VHF FM Transceiver UHF FM Transceiver. March 2011

Leading the way in professional radio communications

Transcription:

NEXEDGE Type-D Trunking System 2015.26.05 Copyright 2014 JVCKENWOOD Corporation. All rights reserved.

1. Type-D Trunking Overview

1. Type-D Trunking System Overview NEXEDGE Type-D Trunking System New affordable NEXEDGE Single Site Trunking System now available. 2

1. Type-D Trunking System Overview MODELS NXR-710 NXR-810 FPU KPG-129D NX-220 NX-320 NX-720 KPG-176D NX-820 3

1. Type-D Trunking System Overview Type-D Enhanced file NXR-710 NXR-810 NX-220 NX-320 NX-720 NX-820 KWD-10DTR (Activation File) Activated by KPG-97FW KWD-NXD20K Type-D Firmware Activation File Activated by KPG-97FW 4

1. Type-D Trunking System Overview Key Sales Points Minimum Investment Type-D Single Site Trunking can be built by purchasing only Repeater Trunking Feature (KPG-10DTR) without any changes to hardware. No Control Cannel Type-D migration is possible for a current analog LTR user. *Note that only 6.25kHz is compatible with Type-D CAI. 12.5kHz is not defined. Security ESN Validation for security feature is available. 5

1. Type-D Trunking System Overview How to built Type-D Single Site Trunking N_SYNC Cable N_SYNC Cable N_SYNC Cable Connected each other by using N_SYNC interface connector up to 30 CH. KTI-5 6

2. Version up Schedule & Comparison List

2. Version up Schedule Release KTI-5 Network Box. FPU Setting, Firmware Update, Log via Web. NX-x20 handle some Data. May 2015 KTI-5 NX-x20 FPU Setting, Firmware Updating, Log gathering NXR-x10 KTI-5 Web Setting, Log GPS, Serial Data, Stun Kill 8

2. Version up Schedule Release Multi Site up to 15 Sites. KTI-3 will be needed per CH. Site Cont. and Multi-Site Cont. will be necessary March 2016 Site Controller KTI-5 Multi-Site Controller KTI-5 System Management NXR-x10 KTI-3 Multi Site Trunking Console, Voice Full Data NX-x20 9

2. Comparison List Function LTR Type-D IOP Type-C Unit ID Required FleetSync 1-2000 1-65519 Group ID 1-250 1-2000 1-65519 Number of Unit ID Required FleetSync 2000x30=60000 3000 Number of Group ID 250x20=5000 2000x30=60000 3000 Transmission Trunked Mode Message Trunked Mode n/a n/a Individual Call Required FleetSync Group Call All Group Call Broadcast Call n/a Available Mar 2016 Emergency Call Required FleetSync Paging Call Required FleetSync Caller ID (PTT ID) Required FleetSync Control Channel (FCC License) decentralized (FB6) decentralized (FB6) Centralized (FB8) Registration n/a n/a ESN Validation n/a Remote Group Add n/a Available Mar 2016 Number of Channels (Repeater) Up to 20 Channels Up to 30 Channels Up to 30 Channels Priority Monitor (Fixed ID) 2 2 4 Late Entry Failsoft Mode (2nd Home) n/a (Available Mar 2016) Telephone Interconnect n/a System Key File Security n/a n/a 6.25kHz Channels n/a 12.5kHz Channels Not defined in Type-D Over-the-Air Alias n/a (w/o Late Entry) Over-the-Air Programming n/a Available Mar 2016 Status Messaging Required FleetSync Short & Long Data Messages Required FleetSync Available Mar 2016 Remote Stun/Kill Required FleetSync Supported from Apr 2015 Transparent Mode Required FleetSync Available Mar 2016 Scrambler (Option) (NXDN) (NXDN) AES/DES Encryption n/a Not defined in Type-D GPS Data Required FleetSync Supported from Apr 2015 Serial Data Interface Supported from Apr 2015 ESN Validation n/a Supported from Dec 2014 IOP Interoperability for ICOM Over-the-Air Alias Alias will not display for late entry because it sent beginning of transmission Number of Group LTR and Type-D can be used same Group ID for each Home Repeaters. Number of Group ID Number of Repeater Note1: Following functions are not Interoperable even if Conventional Short Message Long Message GPS Data Other Data Over-the-Air Alias Note2: Functions with available Mar 2016 may change schedule 10

3. Type-D Configuration

3. Repeater Mode Mode = Type-D Trunking 12

3. Repeater ID Setting Set the Repeater ID 1.Select Program > Individual Settings. 2.Set Repeater ID. 3.Confirm that the repeater is currently connected to a PC, and then click the Write button. Note: Each repeater must have different Repeater ID. 4. Connect next repeater and set different Repeater ID then click the Upgrade (Must be set Repeater ID one by one Connection). Copyright 2015 JVCKENWOOD Corporation. All rights reserved. 13

3. Basic Setting (KPG-129D Ver3.xx) Product Information 1.Select Model > Product Information. 2.Set Model Name, Frequency and Mode Type-D Trunking. And click OK. Channel Setting 1.Select Edit > Chanel Information. 2.Set RX/TX frequencies, CH Type NXDN. Ch1 Data for Repeater ID1 Ch2 Data for Repeater ID2 Ch3 Data for Repeater ID3 Ch4 Data for Repeater ID4 Note: Repeater ID# must equal CH# Copyright 2015 JVCKENWOOD Corporation. All rights reserved. 14

N-SYNC Cables 3. Basic Setting Master Repeater 1.Select Edit > NXDN > Type-D Trunking. 2.Set Primary Master Repeater and Secondary Master Repeater. Note : NXR-710/810 has Trunking Controller capability. Must be required Master Repeater for sending synchronized Data via N-SYNC cable. In case of Primary Master Repeater is failed, Secondary Master Repeater take over. If both Primary and Secondary are failed, Type-D Trunking System doesn t work. Copyright 2015 JVCKENWOOD Corporation. All rights reserved. 15

3. Basic Setting User List 1. Select Edit > > Chanel Information. 2. Click Channel Edit. 3. Set User List. User List Selection: None All radios can be accessed. Group ID List Only pre-programmed Group IDs can be accessed. Unit ID List Only pre-programmed Unit IDs can be accessed. Both Both Only pre-programmed Group and Unit IDs can be accessed. Copyright 2015 JVCKENWOOD Corporation. All rights reserved. 16

3. Basic Setting Pre-Programmed Group ID and Unit ID 1. Select Edit > User List > Group ID List. 2. Set Group ID and Home Channel. 3. Select Edit > User List > Group ID List. 4. Set Unit ID and Home Channel. Home Chanel: NXR-710/810 Type-D Trunking System have Home Channel like LTR system. Up to 30 repeaters and up to 30 home channels for Type-D Trunking System can be set. If Home Channel s repeater is dead, Type-D Trunking system still working with rest of repeaters. But radios programed dead Home Channel cannot access to the repeater. Note: Not required Home Chanel Repeater# equals Master Repeater# Home Chanel is used for handshaking radios. Listed Group ID and Unit ID can be access to NXR-710/810 Type-D Trunking System. Group ID: 0000(All) or 1 to 2000 Unit ID: 1 to 2000 Copyright 2015 JVCKENWOOD Corporation. All rights reserved. 17

3. Basic Setting ESN Validation 1.Select Edit > NXDN > Type-D Trunking. 2.Check NXDN ESN Validation. 3.Select Edit > NXDN > NXDN ESN List. 4.Set radio s Unit ID and NXDN ESN. Note: NXR-710/810 Type-D Trunking system does not have radio registration function like Type-C Trunking System has. For avoiding unauthorized radio access, use NXDN ESN Validation. Radio s NXDN ESN (Electronic Serial Number) is unique ID written by factory and cannot not be duplicated. Copyright 2015 JVCKENWOOD Corporation. All rights reserved. 18

3. Data Write All repeaters have same FPU data to write 1.Select Program > Write Data to Repeater. 2.Set Channel Connected. 3.Click Write to write Data to Repeater. 4.Connect next repeater then update firmware. Copyright 2015 JVCKENWOOD Corporation. All rights reserved. 19

N-SYNC Cables 3. Faster Data Write After set up Type-D Trunking, now you can change FPU data and Firmware much faster FPU Data 1. Confirm N-SYNC connected each repeater. 2. Connect PC to one repeater. 3. Select Program > Write Data to repeater. 4. Set Channel Connected. 5. Click Write. Then All repeater received FPU data via N-SYNC cable. Firmware 1. Execute FPRO.exe and write firmware instead of set repeater as Firmware Programming Mode. 2. Connect PC to one repeater and write the firmware. 3. All repeater received firmware via N-SYNC cable. 4. TX LED lights when completed. You must confirm all repeaters TX LEDs. 5. If could not write the firmware, repeater RX LED blinks and displayed de (Data Error), you must write firmware to each repeaters after Data Error. N-SYSNC Connected Repeater FPU Data and Firmware Write requirement 1. All repeaters have been already written Firmware Version 3.00 or later 2. All repeaters have been already written Type-D Mode FPU data. Copyright 2015 JVCKENWOOD Corporation. All rights reserved. 20

4. Faster Data Write (KPG-129D Ver3.00 or later) After set up Type-D Trunking, now you can change FPU data and Firmware much faster Programming Cable N-SYNC Cables FPU Data 1. Confirm N-SYNC connected each repeater. 2. Connect PC to one repeater. 3. Select Program > Write Data to repeater. 4. Set Channel = ALL. 5. Click Write. Then All repeater received FPU data via N-SYNC cable. Firmware 1. Execute FPRO.exe and write firmware instead of set repeater as Firmware Programming Mode. 2. Connect PC to one repeater and write the firmware. 3. All repeater received firmware via N-SYNC cable. 4. TX LED lights when completed. You must confirm all repeaters TX LEDs. 5. If could not write the firmware, repeater RX LED blinks and displayed de (Data Error), you must write firmware to each repeaters after Data Error. N-SYNC Connected Repeater FPU Data and Firmware Write requirement 1. All repeaters have been already written Firmware Version 3.00 or later 2. All repeaters have been already written Type-D Mode FPU data. Copyright 2015 JVCKENWOOD Corporation. All rights reserved. 21

N-SYNC Cables 4. Faster Data Write Type-D Trunking FPU data and Firmware update through a KTI-5 Copyright 2015 JVCKENWOOD Corporation. All rights reserved. 22

4. KTI-5

4. KTI-5 Hardware 1 N-SYNC (4P4C Modular for Repeater Connection) LAN (RJ45 for 10BASE-T/100BASE-TX Ethernet ) Internal Clock (Lithium-Ion battery backup) Status LED (7 Colors) Input Voltage Current Drain Temperature Range Dimensions (W x H x D) (Exclude projections) Weight DC 13.6V (10.8V to 15.6V) MAX 1.6 A -30ºC to +60ºC 139 x 32 x 105mm 570g 24

4. KTI-5 Hardware 2 DC Cable (2m) Label Modification example KENWOOD KTI-5 KENWOOD Type-D Multi Site Controller Supplied Accessory ITEM P/N Qty N SYNC Cable (1m) E30-7717-XX 1 Cushion G1D-0077-XX 2 Cushion G13-2339-XX 4 Instruction Manual B5A-0555-XX 1 KENWOOD DMR IP Network Attach the KTI-5 to the Repeater Accessory Cabinet using the supplied cushion. There are two methods of attaching the KTI-5: 1. Attach 4 cushions (G13-2339) on the 4 base corners of the KTI-5, and place it into the Accessory Cabinet. 2. Attach the cushion (G1D-0077) to the base of the KTI-5, and attach it to the Accessory Cabinet. 25

4. KTI-5 Initial Setup KTI-5 is provided as HARDWARE and becomes functional product when SOFTWARE is installed (loaded). KTI-5 Hardware (Network Box) KTI-5 Software Option (Firmware) KPG-1006DNA: Network Adapter Software Functional Product Type-D IP Network Adapter Device Install Firmware (Software Option) KTI-5 192.168.0.1 LAN IP Address for PC IP Address 192.168.0.2 Subnet Mask 255.255.255.0 Default Gateway 192.168.0.254 1. Connect PC to KTI-5 (if connect direct, cross cable is require) 2. Set PC IP Address (because normally you PC sets DHCP) 3. Execute Internet Explorer (Ver 9 to 11 recommended) 4. Input KTI-5 IP Address (http://192.168.0.1) 5. Log in to KTI-5 (User Name = admin, Password = none) 6. Go to Maintenance > System > Firmware Update 7. Click Browse to read KPG-1006DNA firmware (*.bin file) 8. Click Update to write the KPG-1006DNA. 9. After uploaded, Login windows with Update succeeded message appeared. Copyright 2015 JVCKENWOOD Corporation. All rights reserved. 26

4. Remote FPU Data Write/Read (with KTI-5) After set up Type-D Trunking with KTI-5, now you can change FPU data by KPG-129D remotely KTI-5 192.168.0.1 N-SYNC Cables LAN IP Address for PC IP Address 192.168.0.2 Subnet Mask 255.255.255.0 Default Gateway 192.168.0.254 FPU Data Write 1. Connect PC to KTI-5 (if connect direct, cross cable is require) 2. Set PC IP Address (because normally your PC sets DHCP) 3. Execute KPG-129D (must be Ver3.10 or later) 4. Select Setup > Communication Port. 5. Set LAN and confirm IP address as Direct. 6. Connect PC to KTI-5 and. 7. Select Program > Write Data to repeater. 8. Set IP Address for KTI-5 and Channel = ALL 9. Click Write. Then All repeater received FPU data via KTI-5. 192. 168. 0. 1 192. 168. 0. 1 FPU Data Read 1. Select Program > Read Data from the Repeater. 2. Set IP Address for KTI-5 and Select Channel for derided Repeater Channel (Repeater ID# must equal Ch#)) 3. Click Read. (All repeater have same FPU Data) Copyright 2015 JVCKENWOOD Corporation. All rights reserved. 27

4. Remote FPU Data Write/Read (with KTI-5) Repeater & KTI-5 Information 1. Select Tools > Repeater Information. 2. Set IP Address for KTI-5 and Select Channel for derided Repeater Channel (Repeater ID# is equal Ch#) 3. Click Read. Data Password 1. Select Edit > Optional Features > Common Page 1 > Data Password 2. Input Password then Click OK 192. 168. 0. 1 Note: Password are stored in Repeater. When select Channel = ALL at Write Data to repeater window., same password are written to all repeater. Not recommended to set different password for each repeater. 192. 168. 0. 1 Copyright 2015 JVCKENWOOD Corporation. All rights reserved. 28

4. Remote Firmware Write (with KTI-5) After set up Type-D Trunking with KTI-5, it can write the Firmware remotely KTI-5 192.168.0.1 N-SYNC Cables LAN IP Address for PC IP Address 192.168.0.2 Subnet Mask 255.255.255.0 Default Gateway 192.168.0.254 Firmware (Software Option) 1. Connect PC to KTI-5 (if connect direct, cross cable is require) 2. Set PC IP Address (because normally you PC sets DHCP) 3. Execute Internet Explorer (Ver 9 to 11 recommended) 4. Input KTI-5 IP Address (http://192.168.0.1) 5. Log in to KTI-5 (User Name = admin, Password = none) 6. Go to Maintenance > System > Firmware Update 7. Click Browse to read KPG-1006DNA firmware (*.bin file) 8. Click Update to write the KPG-1006DNA. 9. After uploaded, Login windows with Update succeeded message appeared. And then Login and see the result (See Next Slide) Copyright 2015 JVCKENWOOD Corporation. All rights reserved. 29

4. Remote Firmware Write (with KTI-5) Login Widows with Update succeeded message KPG-1006DNA firmware Version. Each Repeater firmware update result Success: Update Succeeded Not Connected: Repeater is not connected Skip: Update skipped (because repeater has same firmware) Fail: Check Sun Error (Need to write firmware again) Copyright 2015 JVCKENWOOD Corporation. All rights reserved. 30