TE-7800 Series One-to-One Wireless Room Temperature Sensing System

Similar documents
TE-7700 Series Radio Frequency (RF) Wireless Room Temperature Sensing System

TE Radio Frequency (RF) Receiver with Analog Interface

TE-7700 Series Radio Frequency (RF) Wireless Room Temperature Sensing System

WRZ Series One-to-One Wireless Room Sensing System

FX-WRZ One-to-One Wireless Sensing System

Metasys Zoning Package Commissioning

WRZ-RMT10K-0 Wireless Remote Temperature Transmitter

Wireless Rain and Wireless Rain/Freeze Sensor

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

VT8300 Series Installation Guide 24 Vac Low Voltage

Digi-Wave Technology Williams Sound Digi-Wave White Paper

TE-7700 Series Radio Frequency (RF) Wireless Room Temperature Sensing System

WRZ Receiver for One-to-One Wireless Room Sensing Systems

SmartZone-2 & SmartZone-4

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions

HLC-1000 High-limit Humidity Control

FX-ZFR Series Wireless Field Bus System

Installation Instructions

Smartzone LCD TOUCHPAD USER GUIDE.

Wireless 900 MHz Receiver

Hub and Cluster. ogramming Manual. Pro MAN3090

Wireless Temp/Setpoint & Override Room Transmitter

Installation Manual. Ultra RF Analogue Transmitter QC0168. Manual Ref: QC0168. Version: March

ELECTRONIC THERMOSTAT: T920

Table 1. Placing the Sensor in the Sensor Cradle. Step Instruction Illustration

Wireless CO 2. + TRH Sensor. Installation Guide. Version 1

Wireless Analog Output Modules

CD-Pxx-00-0 Series Duct Mount CO 2 Transmitter

The wireless alternative to expensive cabling...

UNIT A 8-30VDC 8-28VAC POWER V IN3 IN4 COM1/2 NO3 NO4 IN1 IN2 GND NO1 NO2 COM3/4 ANY 8-28VAC OR 8-30VDC POWER ADAPTER (SOLD SEPARATELY)

Headset Intercom System. Operating Instructions

Owner s Manual S5 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

The wireless alternative to expensive cabling...

W I R E L E S S L I N E C A R D

Astra-R Kit Wireless Alarm System Operation Manual

Wireless sensor system

WPR400 Wireless Portable Reader

Installation Instructions

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

v.wrs-rtn Series Receivers for Many-to-One Wireless Room Temperature Sensing Systems

S ENSORLINK INSTALLATION MANUAL

SER8300 Series Terminal Equipment Controller with Optional PIR sensor Installation Guide

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

Rev RF Service Tool Operator s Guide

Disclaimers. Important Notice

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification

The wireless alternative to expensive cabling...

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

With Audible Detect Signal

ET Water SmartWorks Panel Installation Guide

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

Digital Room Sensor Technical Guide

CX-100. Installation Instructions. PIR Occupancy Sensor SPECIFICATIONS

SureCross DX80 FlexPower EZ-LIGHT Node with Integrated Battery

Wireless multizone receiver RDE-MZ6

ZZxD-Nx-xR Series. Wireless Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

v3 360 Passive Infrared Line Voltage Occupancy Sensor

The wireless alternative to expensive cabling...

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

Complete 2.4 GHz RF Transceiver Module with Built-In RFDP8 Application Protocol Part Numbers RFD21733, RFD21735, RFD21737, RFD21738, RFD21739

AW2400iTR USER S MANUAL 2.4 GHz Indoor Wireless Ethernet Radio

Planning Guidelines. Lightcloud. Best Practices for Installing Lightcloud

RF Wireless Serial Device Server

Transmitter. User Manual. Firmware version 1.0 and greater

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

UN2 - Universal controller Building automation s missing link

Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN)

Operating Instructions

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

The Deeter Group. Wireless Site Survey Tool

LBI Installation & Operation

DEVAR Inc. 706 Bostwick Ave., Bridgeport CT Tel , Fax

IRRIGATION 810-3R RECEIVER GUIDE

Programming Manual (V3 Software)

Beat the Competition. A Remote Will Make Your Crew work smarter not harder and earn more money!!!

User Manual. ProRF Encoder Transmitter & Receiver

By Ryan Winfield Woodings and Mark Gerrior, Cypress Semiconductor

Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual

Multilin DGT. Distributed Generation Trip Control Fast & Wireless Trip of Distributed Generators. Control. Advanced Communications

DEVAR Inc. 706 Bostwick Ave., Bridgeport CT Tel , Fax

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

AL-DALI-010v 0-10v Dimmer 3-Way switch with DALI

April 1994 UCM-420A. Setpoint Controller. Operating and Installation Instructions

2.4GHZ WIRELESS SYSTEM FOR POLICE VIDEO RECORDING

Excel 10 W7761A Remote Input/Output Device

Installation Instructions

Radio Link Starter Kit

INSTALLATION INSTRUCTIONS FOR THE CLIKCARD COMMERCIAL RECEIVER (NARROW BAND)

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

Ethernet to 900 MHz RF Modem

OVEN INDUSTRIES, INC. Model 5C7-362

Blue Point Engineering Inc.

Heritage MedCall. Sentry E-Call Model HM-527 Resident Host Panel

RAIN-CLIK. Rain Sensor With Optional Freeze Shutoff for Automatic Irrigation Systems. Owner s Manual and Installation Instructions

Ocean Controls KT-5221 Modbus IO Module

Blue Point Engineering

Blue Point Engineering

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O PRODUCT INFORMATION B&B ELECTRONICS

E-BUS Digital Room Sensor Technical Guide

Transcription:

TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin TE-7820-0, TE-7830-0, TE-7820-1, TE-7830-1 Code No. LIT-12011097 Issued October 4, 2010 Supersedes October 6, 2008 Refer to the QuickLIT Web site for the most up-to-date version of this document. Document Introduction................................................. 3 Related Documentation................................................. 3 One-to-One Temperature Sensing System Overview......................... 4 WRS-TTx Series Wireless Room Temperature Sensors......................... 6 TE-7820 Series Receivers.................................................. 8 TE-7830 Series Receivers.................................................. 9 RF Interference and Security in One-to-One Applications...................... 10 Radio Frequency Addresses for One-to-One Applications...................... 11 Sensor Averaging and High or Low Temperature Selection..................... 12 HVAC PRO Applications That Support a One-to-One System.................... 13 Guidelines for Job Sites with 510 or More TE-7800 Series Receivers............. 14 Detailed Procedures.................................................. 15 One-to-One System Commissioning Overview............................... 15 Commissioning Procedures Requirements..................................... 15 Commissioning Procedures Workflow......................................... 15 Planning and Record-Keeping............................................... 16 Setting the TE-7800 Series Receiver RF Address.............................. 16 Setting the WRS-TTx Series Sensor RF Address.............................. 18 Setting the Sensor Input Mode for Multiple Sensor Applications................. 19 Connecting TE-7800 Series Receivers to Supported Controllers................. 20 Connecting the TE-7820 Receiver to VMA14 Series Controllers.................... 20 Connecting the TE-7830 Receiver to Supported Controllers........................ 22 Configuring Supported Controllers for One-to-One Applications................ 24 Configuring VMA14 Series Controllers for One-to-One Applications.................. 25 Calculating TE-7830 Series Receiver Analog Output Signal Values.................. 27 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 1

Temperature Values for 0 to 5 VDC Analog Signal Applications......................... 27 Temperature Values for 0 to 10 VDC Analog Signal Applications........................ 28 Configuring AS-AHU, AS-UNT, and AS-VAV Controllers for One-to-One Applications... 28 Commissioning AS-AHU, AS-UNT, or AS-VAV Controllers for One-to-One Applications.. 31 Configuring a DX-9100 Interface for a One-to-One Wireless Application.............. 32 Commissioning a DX-9100 Controller for a One-to-One Application.................. 34 Testing for RF Signal Conflicts at Job Sites with Duplicate RF Addresses......... 35 Troubleshooting..................................................... 36 Checking a One-to-One Application s RF Signal Strength...................... 36 Technical Specifications.............................................. 38 WRS-TTx Series Sensors................................................. 38 TE-7800 Series Receivers................................................. 39 2 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin

TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin Document Introduction This document describes how to commission, configure, and troubleshoot WRS-TTx Series Sensors, TE-7800 Series Receivers, and One-to-One wireless room temperature sensing systems. This document also provides some information for configuring supported controllers for One-to-One sensing system applications. This document does not describe how to locate or install the WRS-TTx Series Sensors and TE-7800 Series Receivers. Nor does it describe how to install, commission, operate, or troubleshoot any of the digital field controllers that support One-to-One temperature sensing system applications. Related Documentation Table 1: TE-7800 Series One-to-One System Related Documents For Information On See Document LIT or Part Number Applications, Features, and Benefits of the One-to-One Wireless Room Temperature Sensing System Applications, Features, and Benefits of Wireless Metasys Systems Locating, Mounting, and Wiring the TE-7800 Series Receivers Locating and Mounting the WRS-TTx Series Wireless Room Temperature Sensors Using the WRS-SST Series Wireless Sensing System Tools to Test Radio Frequency (RF) Signal Strength, Locate Sensors and Receivers, and Troubleshoot One-to-One Wireless Sensing Systems TE-7800 Series One-to-One Wireless Room Temperature Sensing System Product Bulletin Wireless Metasys System Product Bulletin TE-7800 Series Receivers for One-to-One Wireless Room Temperature Sensing Systems Installation Instructions WRS-TTx Series Wireless Room Temperature Sensors Installation Instructions WRS-SST Series Wireless Sensing System Tools Technical Bulletin LIT-12011096 LIT-12011244 Part No. 24-10139-8 Part No. 24-10126-19 Part No. 24-10139-16 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 3

One-to-One Temperature Sensing System Overview The TE-7800 Series One-to-One Wireless Room Temperature Sensing System is designed to interface with supported Johnson Controls controllers to provide wireless temperature control of single-zone, room temperature applications. A simple One-to-One wireless room temperature sensing system consists of one to four WRS-TTx Series Wireless Room Temperature Sensors communicating single-zone temperature data to an associated TE-7820 Series or TE-7830 Series Receiver (Figure 1). A TE-7820 Series Receiver interfaces with a single Johnson Controls VMA14 Series Controller. See TE-7820 Series Receivers for more information. A TE-7830 Series Receiver interfaces with a single Johnson Controls AS-AHU, AS-UNT, AS-VAV, DX-9100, or FXxx Series Field Controller. See TE-7830 Series Receivers for more information. See WRS-TTx Series Wireless Room Temperature Sensors for more information on the WRS-TTx Series Sensors. Site Management Portal or Ready Access Portal Client Internet Ethernet Firewall NAE FC Bus VMA1 VMA2 (Stand-Alone) AS-UNT Zone Bus Interface Cable TE-7820 Receiver 1 Zone Bus Interface Cable TE-7820 Receiver 3 Analog Interface Cable TE-7830 Receiver 2 WRS-TTx Sensor 1 WRS-TTx Sensor 3A WRS-TTx Sensor 3B WRS-TTx Sensor 3C WRS-TTx Sensor 2A WRS-TTx Sensor 2B Figure 1: One-to-One Wireless Room Temperature Sensing Applications 4 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin

Note: Multiple WRS-TTx Series Sensor models, TE-7800 Series Receiver models, and WRS-SST Series Wireless Sensing System Tools are available. The WRS-TTx0000-0 Series Sensors, TE-78x0-0 Series Receivers, and WRS-SST-100 Tool have a 15 dbm transmission power. The WRS-TTx0000-1 Series Sensors, TE-78x0-1 Series Receivers, and WRS-SST-101 Tool (CE Mark compliant models) have reduced transmission power (10 dbm) and transmission range to comply with the requirements of select countries. The receiver meets the IEEE 802.15.4 standard for low power, low duty cycle RF transmitting systems and operates on the 2.4 GHz Industrial, Scientific, Medical (ISM) band. The One-to-One wireless room temperature sensing system is designed for indoor applications only, and should not be used for outdoor or inter-building applications. The WRS-TTx Series Sensors and the TE-7800 Series Receivers operate as transceivers to create a bidirectional association between the sensors and the receivers that allows the temperature sensing system to synchronize and confirm data transmissions between the devices. The sensors and receivers must be located and installed properly to provide adequate RF signal strength to maintain this wireless association. The maximum transmission range for indoor line-of-sight transmissions between a WRS-TTx0000-0 Series Sensor and an associated TE-78x0-0 Series Receiver is 500 ft (152 m). Taking into consideration RF signal absorption and reflection due to metal obstructions, walls, and furniture found in typical building interiors, the practical average indoor line-of-sight transmission range between a sensor and receiver is 200 ft (61 m). See Related Documentation for references to installation instructions. The maximum transmission range for indoor line-of-sight transmissions between a WRS-TTx0000-1 Series Sensor and an associated TE-78x0-1 Series Receiver is 375 ft (114 m). Taking into consideration RF signal absorption and reflection due to metal obstructions, walls, and furniture found in typical building interiors, the practical average indoor line-of-sight transmission range between a sensor and receiver is 164 ft (50 m). See Related Documentation for references to installation instructions. The sensors and receivers are associated with each other with unique RF addresses. The RF addresses are established on the devices by setting the switches on address DIP switch blocks on the devices. After the sensor/receiver associations are created, the sensors transmit (at 60 second intervals) the sensed zone temperature, the setpoint temperature, zone occupancy status, and low battery conditions, depending on the WRS-TTx Series Sensor model, the target controller model, and the controller configuration. See Radio Frequency Addresses for One-to-One Applications on page 11, Setting the TE-7800 Series Receiver RFAddress on page 16, and Setting the WRS-TTx Series Sensor RF Address on page 18 for more information on setting RF addresses in One-to-One sensing system applications. TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 5

In One-to-One applications with two to four sensors, the target receiver can be configured to send temperature control data based on the average temperature, the highest temperature, or the lowest temperature sensed by the WRS-TTx Series Sensors. See Sensor Averaging and High or Low Temperature Selection on page 12. The WRS-TTx Series Sensors and the TE-7800 Series Receivers also provide signal strength indication and other wireless diagnostic data. IMPORTANT: The One-to-One wireless room temperature sensing system, TE-7800 Series Receivers, and WRS-TTx Series Sensors are not designed or intended for use in mission-critical or life/safety applications. Note: WRS-TTx Series Sensors and TE-7800 Series Receivers are not compatible with TE-7700 Series Sensors and Receivers. TE-7700 Series Sensors and Receivers are discontinued, and replacements are no longer available for order. If a TE-7700 Series Sensor or Receiver fails in a TE-7700 Wireless Sensing System application, you must replace the TE-7700 Series Receiver with a TE-7800 Series Receiver and replace the associated TE-7700 Sensors with WRS-TTx Series Sensors. WRS-TTx Series Wireless Room Temperature Sensors The WRS-TTx Series Wireless Room Temperature Sensors (Figure 2) are designed to sense room/zone temperature and transmit wireless temperature and zone status data to TE-7800 Series Receivers. Depending on the sensor model, the WRS-TTx Series Sensors can transmit the sensed temperature, setpoint temperature, occupancy status, and low battery conditions to an associated receiver. The receiver passes the temperature data to a controller. Tamper Resistant Set Screw Manual Occupancy Override Button Temperature Setpoint Control Dial Occupancy LED 4-23/32 120 Back of Base to Front of Setpoint Control Dial 1-1/2 38 3-5/32 80 Figure 2: WRS-TTP Wireless Room Temperature Sensor Physical Features and Dimensions, in./mm FIG:dmnsns 6 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin

The WRS-TTx Series Sensors also provide manual occupancy override and signal strength diagnostic capabilities. See Table 2 for the available WRS-TTx Series Sensor models. Table 2: WRS-TTx Series Sensors Product Code Product Description Number WRS-TTP0000-0 WRS-TTP0000-1 WRS-TTR0000-0 WRS-TTR0000-1 WRS-TTS0000-0 WRS-TTS0000-1 Wireless Room Temperature Sensor, Warmer/Cooler (+/-) Setpoint Adjustment, 15 dbm Transmission Power Wireless Room Temperature Sensor, Warmer/Cooler (+/-) Setpoint Adjustment, 10 dbm Transmission Power (CE Mark) Wireless Room Temperature Sensor, No Setpoint Adjustment, 15 dbm Transmission Power Wireless Room Temperature Sensor, No Setpoint Adjustment, 10 dbm Transmission Power (CE Mark) Wireless Room Temperature Sensor, Setpoint Adjustment Scale: 55 to 85 F/13 to 29 C, 15 dbm Transmission Power Wireless Room Temperature Sensor, Setpoint Adjustment Scale: 55 to 85 F/13 to 29 C, 10 dbm Transmission Power (CE Mark) Note: The WRS-TTx0000-0 Series Sensors have a 15 dbm transmission power, and the WRS-TTx0000-1 Series Sensors (CE Mark compliant models) have a reduced transmission power (10 dbm) and transmission range to comply with the requirements of select countries. WRS-TTx Series Wireless Room Temperature Sensors are also designed for use in WRS Series Many-to-One Wireless Room Temperature Sensing Systems. Refer to the WRS Series Many-to-One Wireless Room Temperature Sensing System Technical Bulletin (LIT-12011095) for more information. Note: Do not attempt to set up a WRS-TTx Series Sensor to report to more than one TE-7800 Series Receiver. One-to-One wireless sensing system applications do not support global sharing of a sensor s data. Attempting to set a single sensor to report to multiple receivers typically results in controller malfunctions and loss of temperature control in the zones. TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 7

TE-7820 Series Receivers The TE-7820 Series Receivers (Figure 3) are designed to receive wireless data messages from WRS-TTx Series Sensors and communicate that data via a hard-wired connection to a Johnson Controls VMA14 Series Field Controller. TE-7820-0 RECEIVER RF SIGNAL ZONE BUS 24 VAC 24 VAC COM ZONE BUS to VMA1400 (Tstat) RF ADDRESS MULT XMTRS OFF ON OFF ON 8 4 2 1 Omnidirectional Indoor Antenna 5-1/2 140 2-1/16 52 5-3/4 146 4-13/16 122 AVG HIGH LOW 256 128 64 32 16 FIG:te_7820_0 RF Signal and Zone Bus LEDs 24 VAC Power Supply Terminals Zone Bus to VMA14 Port MULT XMTRS DIP Switch Block for setting the sensor input mode in One-to-One applications with multiple sensors. RF ADDRESS DIP Switch Block Figure 3: TE-7820 Series Receiver Physical Features and Dimensions, in./mm The TE-7820 Series Receiver collects wireless data transmissions containing the sensed zone temperature, the zone temperature setpoint, the zone occupancy status, signal strength measurements, and sensor low-battery conditions from one to four associated WRS-TTx Series Wireless Sensors. The receiver then processes the zone data and delivers that data directly to a single VMA14 Series Controller via a hard-wired zone bus interface. The TE-7820 Series Receiver requires 24 VAC, Class 2 supply power. The receiver has an 8-pin RJ-45 port for the zone bus interface with the VMA14 Series Controller, two Light-Emitting Diodes (LEDs) that indicate RF signal and zone bus status, and two DIP switch blocks for setting the RF address and sensor input mode (Figure 3). 8 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin

8 4 2 1 TE-7830 Series Receivers The TE-7830 Series Receivers (Figure 4) are designed to receive wireless data messages from WRS-TTx Series Sensors and communicate that data via a hard-wired connection to a single supported digital field controller. The TE-7830 Series Receiver collects wireless data transmissions containing the sensed zone temperature, the zone temperature setpoint, the occupancy status, signal strength measurements, and low-battery conditions from one to four associated WRS-TTx Series Wireless Sensors. The receiver then processes the zone data and delivers that data directly to a single supported Johnson Controls AS-AHU, AS-UNT, AS-VAV, DX-9100, or FXxx Series Field Controller over a hard-wired analog interface. Omnidirectional Indoor Antenna 5-1/2 140 2-1/16 52 5-3/4 146 4-13/16 122 TE-7830-0 RECEIVER ANALOG INTERFACE RF SIGNAL Tstat LOW BATTERY 24 VAC 24 VAC COMMON OCCUPANCY RELAY LOW BATTERY RELAY RELAY COMMON ZONE TEMPERATURE OUT SET POINT OUT OUT COMMON OFF ON RF ADDRESS 256 128 64 32 16 AVG HIGH LOW OFF ON REMOVE FOR AS-AHU, DX-9100 FIG:te_7830_0 Jumper J1 RF Signal and Sensor Low Battery LEDs 24 VAC Power Supply Terminals Analog Output Binary Output Terminals Relay Terminals RF ADDRESS DIP Switch Block Figure 4: TE-7830 Series Receiver Physical Features and Dimensions, in./mm MULT XMTRS DIP Switch Block for setting the sensor input mode in One-to-One applications with multiple sensors. TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 9

The TE-7830 Series Receiver requires 24 VAC, Class 2 supply power. The receiver has removable terminal blocks for wiring the analog interface with supported controllers, two Light-Emitting Diodes (LEDs) that indicate RF signal and low sensor battery conditions, and two DIP switch blocks for setting the RF address and sensor input mode (Figure 4). RF Interference and Security in One-to-One Applications The WRS-TTx Series Sensors, TE-7800 Series Receivers, and the One-to-One wireless sensing system are designed to virtually eliminate RF interference with other wireless applications. In most commercial environments, the One-to-One system does not encounter or generate significant RF interference, even in environments that are saturated with cell phones and competing Wireless Fidelity (WiFi) applications. The WRS-TTx Series Sensors and TE-7800 Series Receivers operate on the 2.4 GHz ISM band and use multi-frequency Direct-Sequence, Spread-Spectrum (DSSS) technology. Cell phones do not operate on the 2.4 GHz ISM band, and cell phone interference is not a problem with One-to-One systems, except when a cell phone is operated within 3 ft (1 m) of a WRS-TTx Series Receiver. When One-to-One systems encounter most other WiFi transmissions in the 2.4 GHz ISM band, the transmissions appear as merely noise and do not significantly impact wireless sensing system communication. Using DSSS technology, the WRS-TTx Series Sensor is designed to transmit a rapid sequence of high-speed (2 millisecond) redundant data bursts to the associated receiver every 60 seconds. The sensor transmits up to eight redundant data bursts in rapid sequence, each burst is transmitted on a different Zigbee frequency. When a single data burst is successful received and acknowledged (or if all eight redundant transmissions fail), the sensor goes dormant for 60 seconds and then repeats the transmission burst sequence. These multi-frequency, redundant, data-transmission sequences greatly enhance the success of the wireless sensing system data transmissions. Transmitting short, high-speed data bursts at 60-second intervals also reduces RF data-transmission collisions and interference with other WiFi transmissions. The DSSS technology also prevents most malicious RF interference. RF interference and transmission failures can also be prevented by maintaining an adequate distance between RF transmitting devices. Some examples include: WRS-TTx Series Sensor should not be mounted less than 3 ft (1 m) from a TE-7800 Series Receiver. Cell phones should not be used within 3 ft (1 m) of a WRS-TTx Series Receiver. WiFi access points should be mounted at least 20 ft (6 m) from any WRS-TTx Series Sensor or TE-7800 Series Receiver. 10 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin

Other low-power WiFi transmitting devices should be mounted at least 3 ft (1 m) from any WRS-TTx Series Sensor or TE-7800 Series Receiver. WiFi devices that transmit powerful signals should be mounted at least 20 ft (6 m) from any WRS-TTx Series Sensor or TE-7800 Series Receiver. 2.4 GHz cordless phones and some older phone headsets can cause interference and should not be used anywhere near a One-to-One sensing system. To secure One-to-One RF wireless messages, the WRS-TTx Series Sensors and TE-7800 Series Receivers use a custom Johnson Controls message protocol that prevents deciphering any One-to-One data transmissions that are received or intercepted by any other WiFi devices. Radio Frequency Addresses for One-to-One Applications To establish wireless RF associations in One-to-One applications, you must assign and configure the same, unique RF address on the TE-7800 Series Receiver and the WRS-TTx Series Sensor or sensors associated with that receiver. The RF address for a TE-7800 Series Receiver is configured manually by positioning the numbered switches on the RF ADDRESS DIP switch block on the receiver. The address setup procedure is the same for TE-7820 and TE-7830 Series Receivers. See Setting the TE-7800 Series Receiver RFAddress on page 16. The RF address for each WRS-TTx Series Sensor associated with a TE-7800 Series Receiver must match the receiver RF address. The WRS-TTx Series Sensor s RF address is configured by positioning the numbered switches on the TRANSMITTER ID DIP switch block on the sensor. See Setting the WRS-TTx Series Sensor RF Address. The RF ADDRESS DIP switch block on the receiver and the TRANSMITTER ID DIP switch block on the sensor are binary switch blocks. The switches on each switch block are assigned numbers (1, 2, 4, 8, 16, 32, 64, 128, and 256). The RF address is a number between 1 and 511, equal to the sum of the numbers of the switches that are in the ON position. Thus placing Switches 1, 4, 8, and 32 in the ON position establishes an RF address of 45 for the device. The One-to-One wireless sensing system does not use the PROPERTY CODE DIP switch block. Set all switches on the PROPERTY CODE DIP switch block to OFF on all WRS sensors in One-to-One applications. The PROPERTY CODE DIP switch block is used in Many-to-One wireless sensing systems applications. Refer to the WRS Series Many-to-One Wireless Room Temperature Sensing System Technical Bulletin (LIT-12011095) for more information. TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 11

In multiple-sensor applications, two or more WRS-TTx Series Sensors have the same RF address and the TE-7800 Series Receiver identifies individual sensors by their serial numbers (which is embedded in the sensor s RF transmissions). In the single sensor applications, the receiver associates with the first WRS-TTx Series Sensor with a matching RF address and rejects all others. If 15 minutes pass with no RF transmission from the associated sensor, the receiver attempts to associate with another matching sensor (if one has been received) or waits for the first matching RF transmission. If the TE-7800 Series Receiver fails to respond to a WRS-TTx Series Sensor with a matching RF address, the receiver may have already locked onto another sensor with the same RF address. To clear the receiver from an incorrect association, cycle the receiver power off and back on, or momentarily change the receiver s RF address to a different RF address and then back to the original RF address again. Never use the same RF address for two receivers that are in the same building or general location unless there are 510 or more receivers at the job site and you have thoroughly tested the duplicate address applications signal strengths to ensure that the receivers are well out of the RF signal range of each other s associated sensors. RF signals can reflect off objects or pass through glass windows, and it is possible for RF signals to travel between buildings or reach receivers several floors away. Installations with 510 or more TE-7800 Series Receivers require special consideration. For large installations, contact a Johnson Controls representative for application support. See Guidelines for Job Sites with 510 or More TE-7800 Series Receivers for more information. Sensor Averaging and High or Low Temperature Selection One to four WRS-TTx Series Sensors can be associated with a TE-7800 Series Receiver in a One-to-One sensing system application. In One-to-One applications with one WRS-TTx Series Sensor, the single sensor transmits the sensed temperature, setpoint temperature, occupancy status, and low-battery conditions to the receiver. In One-to-One applications where two to four WRS-TTx Series Sensors are associated with a single receiver, you can choose one of three sensor input modes: Temperature Averaging (AVG): The receiver averages the temperature inputs from all of the associated sensors and uses the average as a single control temperature for the temperature control loop. High Temperature Selection (HIGH): The receiver uses the highest sensed temperature as the control temperature for the temperature control loop. Low Temperature Selection (LOW): The receiver uses the lowest sensed temperature as the control temperature for the temperature control loop. In multiple sensor applications, the receiver must be set to one of the sensor input modes using the MULT XMTRS DIP switch block on the receiver. See Setting the WRS-TTx Series Sensor RF Address for detailed procedures. 12 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin

If more than one of the switches on the MULT XMTRS DIP switch block are positioned ON, the AVG switch takes priority over the HIGH and LOW switches, and the HIGH switch takes priority over the LOW switch. In a multiple sensor application, all of the sensor addresses must match the associated TE-7800 Series Receiver RF address. The receiver identifies the individual sensors by the unique serial number that is programmed into each sensor and sent with each data message from the sensor. Note: In single-sensor and multiple-sensor applications, a One-to-One sensing system interfaces with only one supported controller. HVAC PRO Applications That Support a One-to-One System Table 3 lists the HVAC PRO controller applications that the TE-7800 Series Receivers support. Table 3: Johnson Controls Applications That Support a One-to-One System (Part 1 of 2) Application Group and Application Name RF Receiver TE-7820 Series Air Handlers 100% OA Dual Path - Dual Duct - Hot/Cold Deck Reset - - Air Handlers 100% OA Dual Path - Dual Duct - Zone Control - Yes Air Handlers 100% OA Dual Path - Multizone - Hot/Cold Deck Reset - - Air Handlers 100% OA Dual Path - Multizone - Zone Control - Yes Air Handlers 100% OA Single Path - Constant Discharge Air Temperature - - Air Handlers 100% OA Single Path - Exhaust Air Temp Control - - Air Handlers 100% OA Single Path - Room Control - Yes Air Handlers 100% OA Single Path - Room Control Cooling/Room Reset Heating - Yes Air Handlers 100% OA Single Path - Supply Air Reset from Zone Temperature - Yes Air Handlers MA Dual Path - Dual Duct - Hot/Cold Deck Reset - - Air Handlers MA Dual Path - Dual Duct - Zone Control - Yes Air Handlers MA Dual Path - Multizone - Hot/Cold Deck Reset - - Air Handlers MA Dual Path - Multizone - Zone Control - Yes Air Handlers MA Single Path - Constant Discharge Air Temperature - - Air Handlers MA Single Path - Return Air Control - - Air Handlers MA Single Path - Room Control - Yes Air Handlers MA Single Path - Room Control Cooling/Room Reset Heating - Yes Air Handlers MA Single Path - Supply Air Reset from Return Temperature - - Air Handlers MA Single Path - Supply Air Reset from Zone Temperature - Yes Central Plant Applications - Pump Lead/Lag Control - - Commercial Zoning Applications - Damper Assembly (VAV) - Yes Commercial Zoning Applications - Damper Assembly (VMA) Yes - Commercial Zoning Applications - Rooftop (UNT) 1 - Yes Generic Input/Output - Point Multiplexer 2 - Yes N2 Dial Applications - N2 Dial Module Configuration - - Rooftop Applications - Packaged Rooftop - Yes TE-7830 Series TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 13

Table 3: Johnson Controls Applications That Support a One-to-One System (Part 2 of 2) Application Group and Application Name RF Receiver TE-7820 Series Terminal Unit Applications - Fan Coil - Yes Terminal Unit Applications - Heat Pump - Yes Terminal Unit Applications - TC Fan Coil - - Terminal Unit Applications - Unit Vent - Yes VAV Applications - Dual Duct - Yes VAV Applications - Single Duct - Yes VAV Applications - VMA Dual Duct Yes - VAV Applications - VMA Single Duct Yes - 1. Only the UNT11xx Series has enough binary inputs to support low-battery indication in One-to-One applications. 2. The user must define a sideloop with the appropriate ranging to use the TE-7830 Series Receiver for this application. Guidelines for Job Sites with 510 or More TE-7800 Series Receivers You can create up to 509 unique RF address settings for One-to-One applications at a job site. Job sites that have 510 or more TE-7800 Series Receivers require duplicate RF address settings. Duplicate RF address settings can create random interference and erratic operation in One-to-One applications. Observe the following guidelines when installing 510 or more receivers at a job site: Ensure that One-to-One applications with duplicate RF address setting are located as far from each other as possible to avoid RF signal overlap and conflicts between the applications. Typically, the One-to-One applications with duplicate addresses are out of range of each other if the individual applications are: - two or more floors or building levels apart and not near windows on the same side of the building or near atriums or other open common areas - more than 1,000 ft (300 m) away from each other Test for and verify the absence of RF signal overlap between One-to-One applications with duplicate RF address settings. TE-7830 Series 14 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin

Detailed Procedures One-to-One System Commissioning Overview There are a variety of procedures that must be performed to design, install, commission, configure, and troubleshoot a One-to-One wireless room temperature sensing system. Many of these procedures are contained in this section of this document. Some of the required procedures are presented in other documentation. See the Related Documentation table for references to the documents with information on locating and installing WRS-TTx Series Sensors and TE-7800 Series Receivers. Refer to the supported controller s documentation for information on installing, commissioning, configuring, and troubleshooting the target controller. Commissioning Procedures Requirements To commission a One-to-One wireless temperature sensing application, you need: one to four WRS-TTx Series Sensors one TE-7820 Series or TE-7830 Series Receiver a 24 VAC Class 2 power supply for the receiver an installed, commissioned, and configured VMA14 Series or supported controller a zone bus interface cable for TE-7820 Series Receiver (VMA14 Series Controller) applications or an analog interface cable for TE-7830 Series Receiver (supported digital controller) applications Note: A 9 ft (2.8 m) interface cable is included with each TE-7800 Series Receiver. Additional cable lengths are available for TE-7820 Series Receiver/zone bus applications. You can fabricate longer cables for TE-7830 Series Receiver/analog interface applications. Refer to the TE-7800 Series Receivers for One-to-One Wireless Room Temperature Sensing System Installation Instructions (Part No. 24-10139-8) for more information on cables and cable length limitations. Commissioning Procedures Workflow The procedures required to commission and configure a One-to-One system can be performed in a variety of sequences. The job site and workflow dictate the order in which these procedures are performed. The procedure order shown below is a typical sequence. To commission and configure a One-to-One system, you must perform the following procedures: Install, commission, and configure the target field controller. Install and address the WRS-TTx Series Sensor(s). TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 15

Commission/address and install the TE-7800 Series Receiver. Test the RF signal strength between the associated devices. Connect the TE-7800 Series Receiver to the target controller. Test and confirm operation of the complete One-to-One application. Planning and Record-Keeping When commissioning and configuring a control system with several One-to-One systems and multiple sensors, receivers, and controllers, we strongly recommend that you obtain a set of the building plans, the Heating, Ventilating, and Air Conditioning (HVAC) plans, and the building specifications. Use the building plans and specifications to determine the best line-of-sight RF pathways and the potential locations for the sensors and receivers. Test the potential device locations to determine if the RF signal strength is adequate and adjust device locations as necessary. You should create a sensor/receiver association table to record all of the device addresses and a device map that shows the locations of all sensors, receivers, and supported field controllers for the final as-built control system. Note: Do not create duplicate RF addresses on any of the receivers at your job site. Duplicate RF addresses can cause a variety of problems in One-to-One applications. If your job site has 510 or more receivers, you must take special precautions to avoid RF signal conflicts between One-to-One applications with the same address. See Guidelines for Job Sites with 510 or More TE-7800 Series Receivers on page 14 and Testing for RF Signal Conflicts at Job Sites with Duplicate RFAddresses on page 35 for more information. Setting the TE-7800 Series Receiver RF Address The TE-7800 Series Receiver requires a unique RF address to communicate with associated WRS-TTx Series Sensors. Set the RF address for the receiver by positioning the numbered switches on the RF ADDRESS DIP switch block. See Radio Frequency Addresses for One-to-One Applications for more information. To manually set the TE-7800 Series Receiver RF address: 1. Disconnect power to the TE-7800 Series Receiver. 2. Set the numbered switches on the RF ADDRESS DIP switch block to the desired RF address (Figure 5). 16 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin

OFF ON RF ADDRESS 256 128 64 32 16 8 4 2 1 MULT XMTRS AVG HIGH LOW OFF ON RF Address DIP switch block with DIP switches positioned to create an RF Address value of 45. Multiple Transmitter Input Mode DIP Switch Block with DIP switches positioned for a single sensor application. Figure 5: RF ADDRESS and MULT XMTRS DIP Switch Blocks on a TE-7800 Series Receiver Note: The TE-7800 Series Receivers ship from the factory with all DIP switches set in the OFF position. When the DIP switches are all set in the OFF position (address 0) or all set in the ON position (address 511), the TE-7820 Series Receiver automatically uses the N2 network address assigned to the connected VMA14 Series Controller for its RF address. If your application uses an automatically assigned RF address, you must determine the TE-7820 Series Receiver s RF address and set the RF address on the associated WRS Series Sensor or sensors to match the receiver s assigned RF address. Do not use the 510 RF address setting for a permanent receiver address. Reserve the 510 RF address setting for testing and troubleshooting One-to-One applications. 3. Check the TRANSMITTER ID DIP switch block on the back of the associated sensor and make certain that the POWER switch is set in the OFF position (Figure 7). See Setting the WRS-TTx Series Sensor RF Address for more information. 4. Apply 24 VAC power to the TE-7800 Series Receiver. 5. Repeat this procedure for each receiver in your application. Note: Do not create duplicate addresses on any of the receivers at your job site. Duplicate addresses can cause a variety of problems in One-to-One applications. If your job site has more than 509 receivers, you have to take special precautions to avoid RF signal conflicts between applications with the same address. See Guidelines for Job Sites with 510 or More TE-7800 Series Receivers on page 14 and Testing for RF Signal Conflicts at Job Sites with Duplicate RFAddresses on page 35 for more information. FIG:rf_addrss TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 17

Setting the WRS-TTx Series Sensor RF Address Associate the WRS Series Sensors to a TE-7800 Series Receiver by setting the TRANSMITTER ID DIP switches on the sensors to the same positions as the RF ADDRESS DIP switches on the target TE-7800 Series Receiver so that the RF address setting on both devices match. See Radio Frequency Addresses for One-to-One Applications for more information. If more than one sensor is used in your One-to-One application, the RF address (TRANSMITTER ID) for each sensor must match the RF address (RF ADDRESS) for the associated TE-7800 Series Receiver. The receiver identifies the individual sensors by their serial numbers, which are sent with each sensor transmission. To set the WRS-TTx Series Sensor RF address (TRANSMITTER ID): 1. Remove the WRS-TTx Series Sensor housing from the sensor mounting base as shown in Figure 6. 2. Insert a coin into the slot on the top of the sensor housing, and depress the locking tab on the mounting base to release the housing. 3. Swing the sensor housing off the mounting base. 1. Loosen (but do not remove) the tamper-resistant set screw on the locking tab of the mounting base. Mounting Base Sensor Housing Tabs FIG:cvr_rmvl 4. Pull the bottom of the sensor housing down and off the tabs on the mounting base. Figure 6: Removing the WRS-TTx Series Sensor Housing from its Mounting Base 2. Move the WRS-TTx Series Sensor power switch on the TRANSMITTER ID DIP switch block to the OFF position (Figure 7). 3. Set all of the switches on the PROPERTY CODE DIP switch block to the OFF position (Figure 7). (One-to-One sensing system applications do not use PROPERTY CODE settings for their RF addresses. PROPERTY CODE settings are used in Many-to-One sensing system applications only.) 18 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin

4. Match the receiver RF address by setting the numbered switches on the TRANSMITTER ID DIP switch block to the same positions as the numbered switches on the RF ADDRESS DIP switch block on the associated receiver (Figure 7). Set all five switches on the PROPERTY CODE DIP switch-block to the OFF position. POWER TRANSMITTER ID 256 128 64 32 16 8 OFF ON 4 2 1 PROPERTY CODE 16 8 4 2 1 FIG:wrs_dp_swtch_121 ON OFF WRS-TTx Series Sensor ON/OFF Switch Set the numbered switches on the TRANSMITTER ID DIP switch block to the same position as the DIP switches on the associated TE-7800 Series Receiver. (In this illustration, the total value of the ON switches equals 45.) Figure 7: PROPERTY CODE and TRANSMITTER ID DIP Switch Blocks on the Back of the WRS-TTx Series Sensor Housing 5. Ensure the batteries are installed correctly and move the sensor POWER switch to the ON position (if you are putting the sensor into operation). 6. Reinstall the sensor housing to the wall mount base. 7. If the associated receiver is configured and powered on, you can press the sensor occupancy button to determine if the sensor and receiver are communicating. Setting the Sensor Input Mode for Multiple Sensor Applications Up to four WRS-TTx Series Sensors can be associated with a single TE-7800 Series Receiver. In multiple-sensor One-to-One applications, you must select a sensor input mode for the application by setting the switches on the MULT XMTERS DIP switch block. See Sensor Averaging and High or Low Temperature Selection for more information. In multiple sensor applications requiring setpoint adjustment, the setpoints of each sensor are averaged. If only one sensor is to control the setpoint, the other sensors should not include setpoint adjustment capability. To set the sensor input mode on a TE-7800 Series Receiver for multiple sensor applications: 1. Set the MULT XMTRS DIP switches on the receiver to the required positions. In single-sensor applications, set all three MULT XMTRS DIP switches to the OFF position. In multiple-sensor applications, set the MULT XMTRS DIP switches according to the desired application input mode. TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 19

- If the sensor temperature readings are averaged, set only the AVG DIP switch to the ON position. - If the highest sensor temperature reading is used, set only the HIGH DIP switch to the ON position. - If the lowest sensor temperature reading is used, set only the LOW DIP switch to the ON position. Note: In multiple-sensor applications requiring setpoint adjustment, the setpoints of each sensor are averaged. If only one sensor is to control the setpoint, the other sensors should not include setpoint adjustment capability. If more than one of the switches on the MULT XMTRS DIP switch block are positioned ON, the AVG switch takes priority over the HIGH and LOW switches, and the HIGH switch takes priority over the LOW switch. In single-sensor and multiple-sensor One-to-One applications, the TE-7800 Series Receiver interfaces with only one supported controller. Connecting TE-7800 Series Receivers to Supported Controllers The TE-7820 Series Receiver connects to VMA14 Series Controllers only (Figure 8). The TE-7830 Series Receiver connects to Johnson Controls AS-AHU, AS-UNT, AS-VAV, DX-9100, and FXxx Series Field Controllers (Figure 9). Note: The TE-7800 Series Receivers are sensitive RF devices. To avoid degrading this sensitivity, do not run the interface cable near high voltage power wiring, phase controlled lighting, and/or phase controlled electric motors. Connecting the TE-7820 Receiver to VMA14 Series Controllers To connect the power and zone bus between the TE-7820 Series Receiver and the VMA14 Series Controller using the 6 ft (1.8 m) interface cable provided, see Figure 8 and follow these instructions: 1. Connect the interface cable between the Tstat modular socket on the side of the VMA14 Series Controller and the ZONE BUS to VMA1400 (Tstat) modular socket on the receiver (Figure 8). Note: Additional zone bus interface cables, with lengths up to 100 ft (30.5 m), are available. See the TE-7800 Series One-to-One Wireless Room Temperature Sensing System Product Bulletin (LIT-12011096) for zone bus interface cable ordering information. 20 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin

Tstat 2. Connect the power cable between the 24 VAC spade terminal connections on the side of the VMA14 Series Controller and the 24 VAC spade terminal connections on the receiver (Figure 8). To Supply Transformer 24 VAC COM 24 VAC TE-7820-x Series RF Receiver with Zone Bus Interface RF SIGNAL TE-7820-0 RECEIVER ZONE BUS 24 VAC 24 VAC COM ZONE BUS to VMA1400 (Tstat) RF ADDRESS 256 128 MULT XMTRS AVG HI GH LOW Johnson Controls VMA14 Series Digital Controller 24VAC: 1 24VAC: 2 OFF ON 64 32 16 OFF ON 8 4 2 1 Power and Zone Bus Interface with Johnson Controls VMA14 Series Digital Controller, 6 ft (1.8 m) Interface Cable included with TE-7820-x Series RF Receiver FIG:te7820_wrng Figure 8: TE-7820 Series Receiver Wired to a VMA14 Series Controller Note: One end of the spade terminal connector portion of the interface cable features two Y-spade terminal connectors that tap into the 24 VAC power source provided by the VMA14 Series Controller. The other end of the spade terminal connector portion of the interface cable features a removable screw terminal block that is pushed onto the 24 VAC spade terminal connectors on the receiver. TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 21

Connecting the TE-7830 Receiver to Supported Controllers To connect the power and analog interface cables between a TE-7830 Series Receiver and a supported controller using the 1.8 m (6 ft) cable provided, see Figure 9 and follow these instructions: TE-7830-x Series RF Receiver with Analog Interface Note: Remove Jumper J1 for Johnson Controls AS-AHU, DX-9100, and FXxx Series Controller applications that require disabling the manual override status via the zone temperature. Do not remove Jumper J1 for Johnson Controls AS-UNT or AS-VAV Controller applications. TE-7830-0 RECEIVER ANALOG INTERFACE RF SIGNAL Tstat LOW BATTERY 24 VAC 24 VAC COMMON OCCUPANCY RELAY LOW BATTERY RELAY RELAY COMMON ZONE TEMPERATURE OUT SET POINT OUT OUT COMMON OFF ON RF ADDRESS 256 128 64 32 16 AVG HIGH LOW OFF ON REMOVE FOR AS-AHU, DX-9100 To Supply Transformer Jumper J1 24 VAC 24 VAC COM Johnson Controls AS-AHU, AS-UNT, AS-VAV, DX-9100, or FXxx Series Controller 24 VAC 24 VAC COM OCC BI LOW BAT BI BI COM* TEMP AI-1** 8 4 2 1 SET PT AI AI COM RED BLK BLU YEL GRN WHT ORN BRN Power and Analog Interface with Johnson Controls AS-AHU, AS-UNT, AS-VAV, DX-9100, or FXxx Series Controller, 6 ft (1.8 m) Interface Cable Included with TE-7830-x Series RF Receiver RED BLK BLU YEL GRN WHT ORN BRN * Relay Common (green wire) should be connected to either Binary In COM or Binary In SRC, depending on the field controller. ** Zone Temperature Out (white wire) should be connected to analog input AI-1 of the field controller (zone temperature). Figure 9: TE-7830 Series Receiver Wired to a Supported Controller FIG:te7830_wrng 1. Connect the three-position screw terminal block with the white, orange, and brown wires to the three spade terminal connections on the receiver labeled: a. ZONE TEMPERATURE OUT b. SETPOINT OUT c. OUT COMMON Note: Position the screw terminal block so that the three screw heads are facing outward (Figure 9). 2. Connect the other end of the interface cable with the spade terminal connectors to the appropriate Analog Input (AI) terminations on the controller. If the controller does not accommodate 1/4 in. (6 mm) spade terminal connectors, the wire ends should be clipped and stripped before making the connections. Connect the white wire to the analog input AI-1 of the controller (zone temperature). Connect the orange wire to the analog input selected for setpoint. 22 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin

Note: If a WRS-TTR0000-x Series Sensor is used in the installation, the orange wire should be insulated, taped back, and not connected at the controller end, since there is no setpoint adjustment available on this sensor model. Connect the brown wire to the analog input common. 3. Connect the three-position screw terminal block with the blue, yellow, and green wires to the three spade terminal connections on the receiver labeled: a. OCCUPANCY RELAY b. LOW BATTERY RELAY c. RELAY COMMON Note: Position the screw terminal block so that the three screw heads are facing outward (Figure 9). 4. Connect the other end of the interface cable with the spade terminal connectors to the appropriate Binary Input (BI) terminations on the controller. If the controller does not accommodate 1/4 in. (6 mm) spade terminal connectors, the wire ends should be clipped and stripped before making the connections. 5. Connect the blue wire to the occupancy binary input of the controller. In applications where a binary input is not used for this function, the blue wire should be insulated, taped back, and not connected at the controller end. Note: Remove jumper J1 in AS-AHU, DX-9100, and FXxx Series applications to prevent the zone temperature from being driven low if the manual occupancy override button on the WRS-TTx Series Sensor is pressed. AS-AHU, DX-9100, and FXxx Series Controllers do not use the occupancy override option. See Figure 9 for J1 jumper location. Note: Install jumper J1 in AS-UNT and AS-VAV applications to allow the receiver to drive the zone temperature low if the manual occupancy override button on the WRS-TTx Series Sensor is pressed. AS-UNT and AS-VAV Controllers do not require a separate binary input for occupancy status, since these controllers detect occupancy override when the zone temperature signal goes to 0 V. See Figure 9 for J1 jumper location. 6. Connect the yellow wire to the low-battery binary input terminal on the controller. In applications where a binary input is not available for low-battery conditions, the yellow wire should be insulated, taped back, but not connected at the controller end. 7. Connect the green wire to the controller as follows: For AS-AHU Series Controllers, connect the green wire to BICM or BI COM (24 VAC common). For AS-UNT100 Series Controllers, connect the green wire to 24 VAC. TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 23

For AS-UNT1100 Series Controllers, connect the green wire to BI SRC (24 VAC). For AS-VAV100 Series Controllers, connect the green wire to BINARY COM (24 VAC common). For DX-9100 Series Controllers, connect the green wire to DI COM (24 VAC common). For FXxx Series Controllers, connect the green wire to terminal D01 & D02 COM. 8. Connect the two-position screw terminal block containing the red and black wires to the two spade terminal connections on the receiver identified as 24 VAC and 24 VAC COMMON. Note: Position the terminal block so that the screw heads are facing outward (Figure 9). 9. Connect the other end of the interface cable with the two Y-spade terminal connectors to the appropriate 24 VAC terminations on the controller. If the controller does not accommodate 6 mm (1/4 in.) spade terminal connectors, clip and strip the wire ends before making the connections. Configuring Supported Controllers for One-to-One Applications VMA14 Series Controllers and supported digital field controllers must be properly configured to operate with TE-7800 Series Receivers and One-to-One sensing system applications. You must use the HVAC PRO software tool (Release 8.04B or later) to configure the VMA14, AS-AHU, AS-UNT, and AS-VAV Series Controllers. You must use the GX-9100 Commissioning Tool (Release 8.04 or later) to configure the DX-9100 Controllers. You must use FX Builder to configure the FXxx Series Controllers; refer to the FX Builder literature for more details. Note: It is assumed that the user of this document has a working knowledge of and experience with the HVAC PRO software tool and GX-9100 Commissioning Tool. See Related Documentation on page 3 for references to relevant Johnson Controls user documentation. The procedures that follow describe how to configure only those values in the controller UI that are required for a One-to-One application to interface and operate with VMA14, AS-AHU, AS-UNT, AS-VAV, or DX-9100 Series Controllers. Refer to the controller documentation and the relevant software tool documentation for complete information on configuring the controller. 24 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin

Configuring VMA14 Series Controllers for One-to-One Applications The VMA14 Series Controller is easily configured using the HVAC PRO software tool. HVAC PRO is part of the M-Tool suite of tools. The software also runs on a Metasys Operator Workstation (OWS) connected to the N2 Bus to configure, download, and commission the controller. You configure the VMA14 Series Controller using HVAC PRO software (Release 8.04B or later) by answering a series of yes/no and multiple choice questions, specifying setpoints and other parameters. HVAC PRO software has a library of applications, control sequences, and algorithms that automatically configure the controller in response to the answers. To commission the VMA14 Series Controller: 1. Launch the HVAC PRO software tool. 2. On the File menu, click New. 3. Select Application Group: VAV Applications. 4. Select Applications: VMA Single Duct. 5. Click OK. 6. Answer the questions, up to Thermostat Type. 7. Select the appropriate RF wireless sensor option (Figure 10). Figure 10: Choosing the RF Wireless Sensor Option TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 25

8. Select the appropriate occupancy mode for the sensor (Figure 11). Figure 11: Choosing the Occupancy Mode Note: The third selection for occupancy mode is not recommended since the WRS-TTx Series Sensor LED does not indicate an occupancy mode. 9. Complete the question/answer session. The thermostat type and occupancy button are the only two questions relevant to wireless One-to-One applications. 10. Click the Parameters button. 11. Scroll down in the Parameters list box to the RF wireless thermostat parameter group. Powerfail Diag is TRUE when the RF wireless battery should be replaced. Read the PRN file to determine the point location (look under the VAV Box - RF Wireless Thermost heading), when mapping the point to a supervisory system. AI 1 Zone Temp and AI 2 (either Remote Adjust or Remote Set Point) are configurable similar to other VMA single duct applications; however, these two inputs are fixed at AI 1 and AI 2 when selecting an RF Wireless Thermostat in the VMASingle Duct application. Zero is the default offset for the Zone Temperature. 12. Save the application for a VMA14 Series Controller, then download and commission. Note: The receiver reports to the control system that the zone temperature and setpoint are out of range if an RF transmission is not received from its associated sensor for a period of 15 minutes or more. 26 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin

Calculating TE-7830 Series Receiver Analog Output Signal Values The TE-7830 Series Receiver generates and sends analog signals (0 to 5 VDC) to the target field controller based on data messages from the WRS-TTx Series Sensors. The field controller interprets these analog signals to determine the sensed zone temperature and the zone setpoint. The configuration procedures in this document provide the values required to configure the zone temperature range and the zone setpoint range for AS-AHU, AS-UNT, AS-VAV, and DX-9100 Controllers. In most application scenarios, you should use the values provided in those procedures to configure the zone temperature and zone setpoint ranges for these controllers. Temperature Values for 0 to 5 VDC Analog Signal Applications The 0 to 5 VDC analog signals from the TE-7830 Series Receiver are scaled to zone temperature and zone setpoint values as illustrated in the scales in Figure 12. Use these scaled values in the sections that follow to configure the analog inputs of the AS-AHU, AS-UNT, AS-VAV, or DX-9100 Controller. 5.0 V Zone Temperature Scale (For 0 to 5 VDC Analog Signal) Zone Setpoint Scale (For 0 to 5 VDC Analog Signal) 4.0 V 5.0 V = 115 F/46 C 3.5 V 3.5 V = Sensor Adjustment Dial Positioned Clockwise to + or 85 F/29 C 2.0 V 2.0 V -20 F/-29 C 0.0 V = -20 F/-29 C 0.5 V = Sensor Adjustment Dial Positioned Counterclockwise to - or 55 F/13 C Figure 12: 0 to 5 VDC/Zone Temperature and Zone Setpoint Scale The scaled values in Figure 12 provide the proper linearization for the specific controller selected for the installation. The setpoint adjustment dial can be adjusted from 55 to 85 F or 13 to 29 C on the WRS-TTS0000-x Series Sensor, or it can be adjusted for warmer/cooler (+/-) on the WRS-TTP0000-x Series Sensor. Note: The Zone Setpoint Scale shown in Figure 12 is for -5 to 5 setpoint range applications. 0.5 V Warmer/Cooler (+/-) Adjust or Remote Setpoint 5 85 F/29 C FIG:te_7830_sgnl_scls TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 27

Temperature Values for 0 to 10 VDC Analog Signal Applications The TE-7830 Series Receiver s 0 to 5 VDC analog output signal can be applied to certain controllers that accept only 0 to 10 VDC analog signals. Use the following information to configure controllers that accept only 0 to 10 VDC signals. Note: The calculations and values are the same if the field controller is set up for F or C. In warmer/cooler applications, the range of adjustment can be changed to match the requirements of the application. Table 4 includes setpoint values calculated using the following equations: Setpoint at 0 V = Lower Setpoint (0.5 x K) Setpoint at 10 V = Upper Setpoint + (6.5 x K) where: K = Setpoint Adjustment Range 3 Table 4: Setpoint Values for Warmer/Cooler Setpoint Adjustment Ranges Setpoint Adjustment Range (F or C ) Setpoint Value at 0 V ( F or C) Setpoint Value at 10 V ( F or C) ±5-6.7 26.7 ±3-4.0 16.0 ±1-1.3 5.3 Note: In the procedures that follow, the warmer/cooler setpoint adjustment range is assumed to be ±5 (F or C ). Configuring AS-AHU, AS-UNT, and AS-VAV Controllers for One-to-One Applications AS-AHU, AS-UNT, and AS-VAV Controllers are easily configured using the HVAC PRO software tool. HVAC PRO software is part of the M-Tool suite of tools. The software also runs on a Metasys Operator Workstation (OWS) connected to the N2 Bus to configure, download, and commission the controller. A user can configure the controller using HVAC PRO software (Release 8.04B or later) by simply responding to a series of yes/no and multiple choice questions, specifying setpoints and other parameters. HVAC PRO software has a library of applications, control sequences, and algorithms that automatically configure the controller in response to the answers. To configure an AS-AHU, AS-UNT, or AS-VAV Controller, proceed as follows: 1. Launch the HVAC PRO software tool. 2. Skip to Step 3 to open an existing file and modify it. To create a new application, proceed as follows: a. On the File menu, click New. 28 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin

b. Select the application group and the specific application. c. Answer the questions as required by the application. See Step 3 for specific applications that can support the RF receiver with analog outputs (applications not listed are not supported). 3. To modify an existing application, proceed as follows: a. On the File menu, click Open. b. Select the appropriate file and click OK. c. If necessary, answer the questions and modify the parameters as follows: (1) VAV Applications (Single or Dual Duct) - If no remote setpoint is required, first answer Define setpoint type: with As appropriate to your application, then answer Define Remote AI points with None (Unused). - If a remote setpoint is required, first answer Define setpoint type: with Single setpoint with bias, then answer Define Remote AI points with Warmer/Cooler adjust. - If the temporary occupancy needs to be active, answer Do you want the Temporary Occupied feature? with Yes. - Define a user-defined binary input for battery status. Define the units (State0:Normal,State1:Low). (2) Rooftop Applications (Packaged Rooftop) and Terminal Unit Applications (Unit Vent, Fan Coil, and Heat Pump) - If no remote setpoint is required, answer Define Remote AI points with None (Unused). - If a remote setpoint is required, answer Define Remote AI points with Warmer/Cooler adjust. - If the temporary occupancy needs to be active, answer Do you want the Temporary Occupied feature? with Yes. - Define a user-defined binary input for battery status. Define the units (State0:Normal,State1:Low). (3) Air Handlers MA Single Path (Room Control, Room Control Cooling/Room Reset, and Supply Air Reset from Zone Temperature) and Air Handlers 100% OA Single Path (Room Control, Room Control Cooling/Room Reset, and Supply Air Reset from Zone Temperature) - If a remote setpoint is required, first answer Select the setpoint type: with Single zone setpoint (this question is not presented for Air Handlers MA Single Path or Supply Air Reset from Zone Temperature), then answer Is a remote zone setpoint needed? with Remote setpoint slider. TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 29

- Define a user-defined binary input for battery status. Define the units (State0:Normal,State1:Low). d. Modify the zone temperature analog input as follows: - Zone Temp: Change the Sensor Type to Voltage (V), change the Input Range Low to 0.74 and High to 4.44, and change the Output Range Low to 0 F (-17.8 C) and High to 100 F (37.8 C). e. Modify the remote setpoint analog input as follows. (1) VAV Applications (Single or Dual Duct) - Remote Setpoint: Change the Sensor Type to Voltage (V), change the Input Range Low to 0 and High to 4.0, and change the Output Range Low to 50 F or 10.0 C and High to 90 F or 32.2 C. - Warmer/Cooler Adjust: Change the Sensor Type to Voltage (V), change the Input Range Low to 0 and High to 4.0, and change the Output Range Low to -6.7 F (-21.5 C) and High to 26.7 F (-2.9 C) (for ±5F range). (2) Rooftop Applications (Packaged Rooftop) and Terminal Unit Applications (Unit Vent, Fan Coil, and Heat Pump) - Warmer/Cooler Adjust: Change the Sensor Type to Voltage (V), change the Input Range Low to 0 and High to 4.0, and change the Output Range Low to -6.7 F (-21.5 C) and High to 26.7 F (-2.9 C) (for ±5F range). - Remote Setpoint: Previously the application was configured to operate with a warmer/cooler adjustment. Make the following modifications to obtain an application that supports remote setpoint with bias. Note: If the remote setpoint analog input goes unreliable, the controller defaults this to a setpoint of 0 F or 0 C. The actual setpoints become the values of the biases as follows: - Analog Input Configuration: Change the Long name to Remote SetPoint, change the Sensor Type to Voltage(V), change the Input Range Low to 0 and High to 4.0, and change the Output Range Low to 50 F or 10.0 C and High to 90 F or 32.2 C. - Parameter Configuration, Zone Heating Setpoint: Change the OccHtg Setpt to -2 F or -1 C and the name to Occ Htg Bias, change the Stby Htg Setpt to -4 F or -2 C and the name to Stby Htg Bias, and change the Unocc Htg Setpt to -9 F or -5 C and the name to Unocc Htg Bias. - Parameter Configuration, Zone Cooling Setpoint: Change the OccClg Setpt to 2 F or 1 C and the name to Occ Clg Bias, change the Stby Clg Setpt to 4 F or 2 C and the name to Stby Clg Bias, and change the Unocc Clg Setpt to 9 F or 5 C and the name to Unocc Clg Bias. 30 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin

(3) Air Handlers MA Single Path (Room Control, Room Control Cooling/Room Reset, and Supply Air Reset from Zone Temperature) and Air Handlers 100% OA Single Path (Room Control, Room Control Cooling/Room Reset, and Supply Air Reset from Zone Temperature) - Rem Zone Setpnt: Change the Sensor Type to Voltage (V), change the Input Range Low to 0 and High to 4.0, and change the Output Range Low to 50 F or 10.0 C and High to 90 F or 32.2 C. f. Save the application for the appropriate controller type. g. Download the application to the controller. Commissioning AS-AHU, AS-UNT, or AS-VAV Controllers for One-to-One Applications AS-AHU, AS-UNT, and AS-VAV Controllers are easily commissioned using the HVAC PRO software tool (Release 8.04B or later). For AS-UNT and AS-VAV Controllers, do not remove Jumper J1 (identified in Figure 2 on the TE-7830 Series Receiver). With Jumper J1 not removed, occupancy override status is enabled via the zone temperature. Set the AS-UNT or AS-VAV analog input switches for 0 to 10 VDC. For AS-AHU Controllers, set the analog input switches for voltage and remove Jumper J1. To ensure proper operation of the TE-7830 Series Receiver and the AS-AHU, AS-UNT, or AS-VAV Controller, verify the following features (if chosen): 1. Validate communication from the zone sensor to the controller as follows: a. Monitor the zone setpoint analog input and rotate the setpoint adjustment dial the entire range. Note: For multiple sensor installations, move the adjustment dials to low end of the setpoint range on all of the sensors. Test each sensor individually by moving the adjustment dial on each sensor (one at a time) through the entire range to verify the response to that sensor. Remember to return the dial to the low end of the setpoint range before testing the next sensor. You can wait for a sensor to report the adjustment to the receiver or simply press the occupancy override button to initiate an immediate sensor transmission to the receiver. b. Press the manual occupancy override button and verify that the Temp Occ status momentarily becomes Closed. Note: For multiple sensor applications, repeat Steps 1a and 1b for each sensor. TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 31

2. Validate wiring for zone temperature and battery status as follows: a. Loosen the screw for ZONE TEMPERATURE OUT and remove the white wire from the terminal block. b. Verify that the zone temperature went unreliable at the controller. c. Reconnect the white wire to the screw terminal pluggable block. d. Use a jumper to short the RELAY COMMON terminal and the LOW BATTERY RELAY terminal on the receiver. e. Verify that a low battery status was read by the controller. Configuring a DX-9100 Interface for a One-to-One Wireless Application DX-9100 Controllers are easily configured using the GX-9100 Programming Tool, which is part of the M-Tool suite of tools. The software also runs on a Metasys Operator Workstation (OWS) connected to the Metasys network to configure, download, and commission the controller. Note: It is assumed that the user of this document has basic knowledge of and experience using the GX-9100 Programming Tool. A user can configure the controller using the GX-9100 Programming Tool (Release 8.02 or later) by specifying data for the analog and binary input points. To configure a DX-9100 Controller, proceed as follows: 1. Launch the GX-9100 Programming Tool. 2. Either create a new application or open an existing file and modify it. 3. If the analog input has already been set to Active, proceed directly to Step 4b. If the analog input has been defined as Passive, proceed as follows: a. Note which program module connections the analog input has. b. Right-click the analog input and select Delete. c. Confirm the Delete by clicking Yes. 4. Modify the zone temperature analog input as follows: a. Right-click on the analog input to be configured as zone temperature and select Active. b. Right-click the analog input and select Data. c. Change the User Name to ZN-T. d. Change the Type of Active Input to the number 0 which represents 0to10VDC. e. Change the High Range to 250 F (121.1 C). f. Change the Low Range to -20 F (-28.9 C). g. Modify the other defaults as required by the application. h. Click OK. 32 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin

i. Reestablish the analog input connections to the appropriate program modules if they had been previously defined. 5. If required, modify the remote setpoint analog input as follows: a. Right-click the analog input to be configured as remote setpoint and select Active. b. Right-click the analog input and select Data. c. Change the User Name to ZN-SP. d. Change the Type of Active Input to the number 0, which represents 0 to 10 VDC. e. Change the High Range to 150 F (65.6 C). f. Change the Low Range to 50 F (10 C). g. Modify the other defaults as required by the application. h. Click OK. 6. If required, modify the warmer/cooler adjust analog input as follows: a. Right-click on the analog input to be configured as warmer/cooler adjust and select Active. b. Right-click the analog input and select Data. c. Change the User Name to ZN-WC. d. Change the Type of Active Input to the number 0 which represents 0 to 10 VDC. e. Change the High Range to 26.7 F (-2.9 C). f. Change the Low Range to -6.7 F (-21.5 C). g. Modify the other defaults as required by the application. h. Click OK. 7. Modify the occupancy override digital input as follows: a. Enter a timer module for the desired occupancy override. Do not invert the timer module. b. Connect the digital input to the Input Connection #x (non-inverted) of the timer module. c. Right-click the timer module to be configured and select Data. d. Change the appropriate Timer #x Type to 5 (OFFdelay). e. Change the Time Units #x to 1 (minutes). f. Change the Time Period #x to the desired occupancy override time in minutes. g. Click OK. TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 33

h. Connect the output of the timer (PMnTDOx, where n is the module number and x is the timer number) to the occupancy override logic. 8. Map the battery status digital input to the supervisory system to provide an alarm when the sensor battery is low (State 0: Normal, State1: Low). 9. Save the application for the appropriate controller firmware version. 10. Download the application to the DX9100 Controller. Commissioning a DX-9100 Controller for a One-to-One Application DX-9100 Controllers are easily commissioned using the GX-9100 Commissioning Tool (Release 8.04 or later). Remove Jumper J1 (Figure 4 on page 9) to disable occupancy override status via the zone temperature. To ensure proper operation of the TE-7830 Series Receiver and the DX-9100 Controller, verify the following features (if chosen): 1. Validate communication from the zone transmitter to the controller as follows: a. Monitor the zone setpoint analog input and move the setpoint adjustment dial the full range. For multiple transmitter installations, move all but one adjustment dial to the bottom end of the setpoint range and then move the remaining adjustment dial to verify its response. b. Press the manual occupancy override button and verify the occupancy override status. c. For multiple transmitter installations, repeat Steps 1a and 1b for each transmitter. 2. Validate wiring for zone temperature and battery status as follows: a. Loosen the screw for ZONE TEMPERATURE OUT and remove the white wire from the screw terminal pluggable block. b. Verify that the zone temperature reading drops below 32 F (0 C). c. Reconnect the white wire to the screw terminal pluggable block. d. Use a jumper to short the RELAY COMMON terminal and the LOW BATTERY RELAY terminal on the receiver. e. Verify that a low battery status was read by the controller. 34 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin

Testing for RF Signal Conflicts at Job Sites with Duplicate RF Addresses Job sites with 510 or more TE-7800 Series Receivers require duplicate RF addresses on some of the receivers and sensors. See Guidelines for Job Sites with 510 or More TE-7800 Series Receivers on page 14 for more information on locating receivers and sensors at job sites with duplicate RF addresses. After you have determined the locations for the receivers and sensors with duplicate RF addresses, you should test the RF communication between the devices and ensure there are no RF conflicts between the applications with duplicate RF addresses before permanently mounting the sensors and receivers. To test for RF signal conflicts at job sites with duplicate RF addresses: 1. Set the RF addresses on the receivers that have duplicate addresses (Receiver A and Receiver B) to the test RF address setting of 510, temporarily position the receivers at their intended locations, and then power only Receiver A on. Note: You can monitor WRS-TTx Series Sensors and TE-7800 Series Receivers in One-to-One wireless sensing systems via a wireless connection using the WRS-SST Series Wireless Sensing System Tools. Refer to the WRS-SST Series Wireless Sensing System Tools Technical Bulletin (Part No. 24-10139-16) for more information on using the WRS-SST Series Tool to monitor One-to-One applications over a wireless connection. 2. Create a temporary, movable test sensor by setting the RF address (on the TRANSMITTER ID DIP switch) to 510 on an unmounted WRS-TTx Series Sensor and power the sensor on. 3. Temporarily locate the test sensor at the intended location for Sensor A (that associates with Receiver A), and press the manual occupancy override button to ensure that the test sensor does communicate with Receiver A. Note: If Receiver A associates with more than one sensor, repeat Step 3 for each Sensor A location to ensure that all of the A sensors do communicate with Receiver A. 4. Next, temporarily locate the test sensor at the intended location for Sensor B (that associates with Receiver B) and press the manual occupancy override button to ensure that the test sensor does not communicate with Receiver A. Note: If Receiver B associates with more than one sensor, repeat Step 4 for each Sensor B location to ensure that all of the B sensors do not communicate with Receiver A. 5. Power Receiver A off and power Receiver B on. Repeat the procedures above to test both the A and B sensor locations and ensure that the: B sensors do communicate with Receiver B A sensors do not communicate with Receiver B TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 35

Troubleshooting Checking a One-to-One Application s RF Signal Strength You should verify adequate RF signal strength between sensors and receivers, especially in applications with excessive distances or metal barriers (such as ductwork, concrete with metal reinforcements, equipment rooms, or elevator shafts). The RF signal strength in One-to-One wireless sensing system applications can be checked ahead of time as follows: 1. Set the DIP switches on the sensor and receiver (or the wireless sensing system tool) to the same RF address. Make sure that the switches on the PROPERTY CODE DIP switch block on the sensor are all set to the OFF position. 2. Provide temporary 24 VAC power to the TE-7800 Series Receiver and hold the receiver in the desired mounting location. (As an alternative, use the optional battery-powered WRS-SST Series Wireless Sensing System Tools). 3. Hold the WRS-TTx Series Sensor near its desired mounting location in the zone, with the battery installed and the power switch set to ON. 4. Observe the Wireless LED on the receiver. Approximately every 60 seconds, an RF transmission occurs and the LED blinks. You can force the sensor into Rapid Transmit Mode by pressing the WRS-TTx Series Sensor s manual occupancy override button for 3 seconds or more. In Rapid Transmit Mode, the sensor transmits a signal every 10 seconds for 30 minutes. After each transmission, the occupancy override LED on the sensor flashes (one, two, or three times) on to indicate the signal strength between the sensor and the receiver. Also, the signal strength LED on the receiver blinks off to indicate the relative signal strength between the sensor and receiver. Three consecutive flashes (of the sensor LED) or blinks (of the receiver LED) every 10 seconds indicate an excellent signal strength. Two consecutive flashes (of the sensor LED) or blinks (of the receiver LED) every 10 seconds indicate a good signal strength. One flash (of the sensor LED) or blink (of the receiver LED) every 10 seconds indicates a weak signal strength. A weak signal strength may result in sporadic loss of data; therefore, reconsider the sensor and/or receiver mounting locations. If relocating the sensor fails to improve the RF signal reception at the receiver, try rotating the antenna in 45-degree increments, selecting a different mounting plane where at least 2 in. (102 mm) of the antenna are below metal structures, or selecting a new mounting location. Note: The TE-7820 Series Receiver may be wired up to 300 ft (91 m) from a VMA14 Series Controller, and the TE-7830 Series Receiver may be wired up to 100 ft (30 m) from a supported Johnson Controls controller. 36 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin

5. Check the receiver for adequate RF signal strength after the building occupant moves into the space. Checking a second time ensures that none of the occupant furnishings or equipment interferes with RF signal reception. See Table 5 for troubleshooting additional problems or symptoms, possible causes, and suggested course of action. Table 5: Troubleshooting One-to-One Wireless Sensing Applications (Part 1 of 2) Problem or Symptom Cause/Action WRS-TTx Series Sensor is not associated with the target receiver. (This is indicated by pressing the manual occupancy override button on the sensor and the occupancy override LED does not light.) The WRS-TTx Series Sensor batteries may be low. Replace the sensor batteries. Refer to the WRS-TTx Series Wireless Room Temperature Sensors Installation Instructions (Part No. 24-10126-19) for information on replacing the batteries. The sensor and receiver RF addresses may not match. Check/reconfigure the RF addresses on the sensor and associated receiver. See Setting the TE-7800 Series Receiver RF Address on page 16 and Setting the WRS-TTx Series Sensor RF Address on page 18 for more information. The sensor and receiver may be out of RF signal range or there may be a RF signal obstruction between them. Check the RF signal strength and path between the sensor and receiver using the WRS-SST Series Wireless Sensing System Tools. The receiver antenna may be positioned poorly. Reposition the receiver antenna and recheck the sensor/receiver association at the sensor. TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 37

Table 5: Troubleshooting One-to-One Wireless Sensing Applications (Part 2 of 2) Problem or Symptom Cause/Action Zone temperature control and/or zone setpoint is incorrect, unreliable, or erratic. Technical Specifications WRS-TTx Series Sensors (Part 1 of 2) Product Codes Power Requirements Addressing Ambient Operating Temperature Limits Ambient Operating Humidity Limits Ambient Storage Temperature Limits The WRS-TTx Series Sensor batteries may be low. Replace the sensor batteries. Refer to the WRS-TTx Series Wireless Room Temperature Sensors Installation Instructions (Part No. 24-10126-19) for information on replacing the batteries. The zone temperature or setpoint values/range may be configured incorrectly in the field controller. Check analog signal set up. See Calculating TE-7830 Series Receiver Analog Output Signal Values on page 27. More than one sensor may have the same RF address as the receiver and the receiver is not set for multiple sensors. Check sensor and receiver addresses. See Setting the TE-7800 Series Receiver RF Address on page 16 and Setting the WRS-TTx Series Sensor RF Address on page 18 for more information. An obstruction may have been placed in the RF path between the sensor and the receiver. Check the RF path and the signal strength between the sensor and the receiver. New RF/WiFi interference may have been introduced into the One-to-One environment. Check for changes to the RF/WiFi environment and new sources of RF interference. Two receivers may have duplicate RF addresses and overlapping signal coverage with associated sensors. Check for duplicate RF addresses and ensure there is no signal overlap in applications with duplicate RF addresses. See Guidelines for Job Sites with 510 or More TE-7800 Series Receivers. The wiring between the receiver and the field controller may be incorrect or damaged. Check the wiring between the receiver and the field controller. The sensor may be defective or damaged. Turn off the suspect sensor and configure a new sensor with the receiver address. Check the operation of the new sensor with the receiver. WRS-TTP0000-x Series Sensors: Warmer/Cooler (+/-) Setpoint Adjustment WRS-TTR0000-x Series Sensors: No Setpoint Adjustment WRS-TTS0000-x Series Sensors: Setpoint Adjustment Scale 55 to 85 F/13 to 29 C 3 VDC Supplied by Two 1.5 VDC AA Alkaline Batteries (Included with Sensor); Typical Battery Life: 60 Months (48 Months Minimum) DIP Switches, Field Adjustable for up to 511 Unique Transmitter ID Addresses and for Up to 31 Unique Property Code Addresses -0 to 122 F (18 to 50 C) 5 to 95% RH, Noncondensing -40 to 160 F (-40 to 71 C) 38 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin

WRS-TTx Series Sensors (Part 2 of 2) Ambient Storage Humidity Limits RF Band Transmission Power Transmission Range Transmissions Temperature System Accuracy Temperature Sensor Type Materials Mounting Compliance (WRS-TTx0000-0 Series Sensors) Compliance (WRS-TTx0000-1 Series Sensors) 5 to 95% RH, Noncondensing Direct-Sequence, Spread-Spectrum, 2.4 GHz ISM Bands WRS-TTx0000-0 Series Sensors: 15 dbm Maximum WRS-TTx0000-1 Series Sensors: 10 dbm Maximum WRS-TTx0000-0 Series Sensors: 500 ft (152 m) Maximum Indoor Line-of-Sight; 200 ft (61 m) Practical Average Indoor WRS-TTx0000-1 Series Sensors: 375 ft (114 m) Maximum Indoor Line-of-Sight; 165 ft (50 m) Practical Average Indoor Every 60 Seconds (+20 Seconds); Every 10 Seconds (+2 Seconds) in Rapid Transmit Mode 1F (0.6C ) Over the Range of 55 to 85 F (13 to 29 C); 1.5F (0.9C ) Over a Range of 32 to 55 F (0 to 13 C) and 85 to 110 F (29 to 43 C) Local 10k ohm Negative Temperature Coefficient (NTC) Thermistor NEMA 1 White Plastic Housing Double-Sided Adhesive Foam Tape Mount; Double-Sided Adhesive Foam Tape Included with Sensor United States: Transmission Complies with FCC Part 15.247 Regulations for Low Power Unlicensed Transmitters Transmitter FCC Identification: CB2-TMPSENS2400A Canada: Industry Canada IC: 279A-TSENS24A Australia and New Zealand: Australia/NZ Emissions Compliant (C-Tick Mark) Europe: CE Mark Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the R&TTE Directive 1999/05/EC. South Africa: Accepts Directives for Europe Shipping Weight 0.3 lb (0.14 kg) TE-7800 Series Receivers (Part 1 of 2) Product Codes Field Controller Interface Power Requirements Addressing Ambient Operating Temperature Limits Ambient Operating Humidity Limits Ambient Storage Temperature Limits Ambient Storage Humidity Limits TE-7820-x Series Receivers for One-to-One Zone Bus Interface Applications TE-7830-x Series Receivers for One-to-One 0 to 5 VDC Analog Interface Applications TE-7820-x Series Receivers: Power and Zone Bus Interface between TE-7820-x Series Receiver and VMA14 Series Controller TE-7830-x Series Receivers: Power and 0 to 5 VDC Analog Interface between TE-7830-x Series Receiver and AS-AHU, AS-UNT, AS-VAV, DX-9100, and FXxx Series Controller 24 VAC (+10%/-15%), 50/60 Hz, 4.5 VA (Minimum) Class 2 Power Supply TE-7820-x Series Receivers: DIP Switches, Field Adjustable for up to 510 Unique Addresses; for Addresses 0 and 511, the TE-7820-x Series Receiver Matches the N2 Address of the Associated VMA14 Series Controller for Its Actual Address TE-7830-x Series Receivers: DIP Switches, Field Adjustable for up to 510 Unique Addresses; Addresses 0 and 511 are Invalid 32 to 122 F (0 to 50 C) 5 to 95% RH, Noncondensing -40 to 160 F (-40 to 71 C) 5 to 90% RH, Noncondensing TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 39

TE-7800 Series Receivers (Part 2 of 2) RF Band Transmission Power Transmission Range Transmissions Receiver Outputs Temperature System Accuracy Sensor Type Wiring Terminations and Network Interfaces Materials Mounting Compliance (TE-78x0-0 Series Receivers) Compliance (TE-78x0-1 Series Receivers) Direct-Sequence, Spread-Spectrum, 2.4 GHz ISM Bands TE-78x0-0 Series Receivers: 15 dbm Maximum TE-78x0-1 Series Receivers: 10 dbm Maximum TE-78x0-0 Series Receivers: 500 ft (152 m) Maximum Indoor Line-of-Sight; 200 ft (61 m) Practical Average Indoor TE-78x0-1 Series Receivers: 375 ft (114 m) Maximum Indoor Line-of-Sight; 165 ft (50 m) Practical Average Indoor Every 60 Seconds (±20 Seconds) TE-7820-x Series Receivers: One Zone Bus Output for Temperature, Setpoint, Field Strength Measurements, and Low Battery Indication TE-7830-x Series Receivers: Two Analog Outputs for Zone Temperature and Setpoint: 0 to 5 VDC, 2 ma Maximum; Two Binary Outputs for Occupancy and Low Battery: Dry Contacts Rated for 24 VAC, 50 ma Maximum 1F (0.6C ) Over the Range of 55 to 85 F (13 to 29 C); 1.5F (0.9C ) Over a Range of 32 to 55 F (0 to 13 C) and 85 to 110 F (29 to 43 C) Internal 10k ohm Negative Temperature Coefficient (NTC) Thermistor TE-7820-x Series Receivers: One Two-Position Terminal Block for 24 VAC Class 2 Supply Power and One Zone Bus Port TE-7830-x Series Receivers: One Two-Position Terminal Block for 24 VAC Class 2 Supply Power, One Three-Position Terminal Block for Occupancy and Low Battery Binary Output Relays, and One Three-Position Terminal Block for Zone Temperature and Setpoint Temperature Outputs Gray Plastic Housing with UL94-5VB Flammability Rating Screw Mount; Four No. 6 Pan-Head, Sheet-Metal Screws Included United States: Intended for NEC Class 2 Connection UL Listed, File E107041, CCN PAZX UL 94-5VB Flammability Rating FCC Compliant to CFR 47, Part 15, Subpart B, Class A Transmission Complies with FCC Part 15.247 Regulations for Low Power Unlicensed Transmitters Receiver Radio Module FCC Identification: CB2-RFMOD2400A Canada: Intended for CEC Class 2 Connection UL Listed, File E107041, CCN PAZX7 UL 94-5VB Flammability Rating Industry Canada IC: 279A-RFMOD24A Australia and New Zealand: Australia/NZ Emissions Compliant (C-Tick Mark) Europe: CE Mark Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the R&TTE Directive 1999/05/EC. South Africa: Accepts Directives for Europe Shipping Weight 1.0 lb (0.45 kg) The performance specifications are nominal and conform to acceptable industry standard. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. 40 TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin

Building Efficiency 507 E. Michigan Street, Milwaukee, WI 53202 Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 2010 Johnson Controls, Inc. TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin 41 Published in U.S.A. www.johnsoncontrols.com