A Residual Gas Analyzer for Dry Etching Process

Similar documents
Development of a Small Residual Gas Analyzer Utilizing the Quadrupole Array Structure Micropole System ~ QL Series ~

EXPERIMENT # 3: Oxidation and Etching Tuesday 2/3/98 and 2/5/98 Thursday 2/10/98 and 2/12/98

PROFILE CONTROL OF A BOROSILICATE-GLASS GROOVE FORMED BY DEEP REACTIVE ION ETCHING. Teruhisa Akashi and Yasuhiro Yoshimura

Nanofluidic Diodes based on Nanotube Heterojunctions

Advanced Plasma Technology. High precision film thickness trimming for the TFH industry. Roth & Rau AG September 2009

EXPERIMENT # 3: Oxidation and Etching Week of 1/31/05 and 2/7/05

LAM TCP 9400 PTX Silicon Trench Etch Process Monitoring for Fault Detection and Classification

Major Fabrication Steps in MOS Process Flow

discovery in 1993 [1]. These molecules are interesting due to their superparamagneticlike

POLYMER MICROSTRUCTURE WITH TILTED MICROPILLAR ARRAY AND METHOD OF FABRICATING THE SAME

A large-area wireless power transmission sheet using printed organic. transistors and plastic MEMS switches

Basic Principles and Operation of Transformer

General information 1 / 17

Technology for the MEMS processing and testing environment. SUSS MicroTec AG Dr. Hans-Georg Kapitza

Partial Replication of Storms/Scanlan Glow Discharge Radiation

Real time plasma etch control by means of physical plasma parameters with HERCULES

Enable Highly-Stable Plasma Operations at High Pressures with the Right RPS Solution

CMOS Digital Integrated Circuits Lec 2 Fabrication of MOSFETs

Characterization of Common Electron Multipliers in Harsh Environments

ELECTRICAL CHARACTERIZATION OF ATMOSPHERIC PRESSURE DIELECTRIC BARRIER DISCHARGE IN AIR

Obducat NIL 6. Nanoimprinting with NRF s NIL 6

Construction Status of SuperKEKB Vacuum System

DUOLINE. Rotary vane pumps for all applications in the low and medium vacuum range

University of Minnesota Nano Fabrication Center Standard Operating Procedure Equipment Name:

Masking: Each mirrored sheet is well protected by a durable paint backing and

Part 5-1: Lithography

High definition printing for critical Industrial applications

(12) Patent Application Publication (10) Pub. No.: US 2004/ A1

The Design of Gating System 2. Introduction to the gating system

Ion beam etch and deposition systems

Residual Gas Analyzers XT Series

Roman Pots. Marco Oriunno SLAC, PPA. M.Oriunno, SLAC

PROCESS DEVELOPMENT FOR SMALL-AREA GaN/AlGaN HBT s

Silicon Light Machines Patents

Continuous Modification Treatment of Polyester Fabric by Dielectric Barrier Discharge

Semiconductor Manufacturing Technology. Semiconductor Manufacturing Technology. Photolithography: Resist Development and Advanced Lithography

NITROGEN DIOXIDE NO2 SS SOLID ELECTROCHEMICAL SENSOR

Subminiature Photoionization VOC Sensor Boris Dolgov, Baseline-MOCON, Inc.

Design Rules for Silicon Photonics Prototyping

Yoshihiko ISOBE Hiroshi MUTO Tsuyoshi FUKADA Seiji FUJINO

Series 10-ZSE30A(F)/10-ISE30A

O2 SS OXYGEN SOLID ELECTROCHEMICAL SENSOR

Design and construction of double-blumlein HV pulse power supply

A SEMINAR REPORT PRESENT ON AIR BLAST CIRCUIT BREAKER

(12) Patent Application Publication (10) Pub. No.: US 2011/ A1

Metal Mould System 1. Introduction

Transpector 2. Gas Analysis System. NEW-GENERATION RGAs WITH SUPERIOR SENSITIVITY AND PERFORMANCE

HIGH POWER INPUT COUPLERS FOR THE STF BASELINE CAVITY SYSTEM AT KEK

oxy.iq Panametrics Oxygen Transmitter Applications Features bhge.com Two-wire, loop-powered 4 to 20 ma transmitter An oxygen transmitter for use in:

AN ELECTRET-BASED PRESSURE SENSITIVE MOS TRANSISTOR

Monolithically integrated InGaAs nanowires on 3D. structured silicon-on-insulator as a new platform for. full optical links

Mobile Electrostatic Carrier (MEC) evaluation for a GaAs wafer backside manufacturing process

CHOOSE YOUR WEAPON. a wide variety of interchangeable lens tints that enhance vision in all light and weather conditions.

Progress towards Actinic Patterned Mask Inspection. Oleg Khodykin

Voltage Control for Reactive Sputtering: Improving Typical Sputter Rate while Dramatically Reducing Input Power Requirements

Photoresist erosion studied in an inductively coupled plasma reactor employing CHF 3

an ISO9001 company TECHNICAL INFORMATION FOR TGS8100 Technical Information for Air Quality Control Sensors

Dry Etching Technology for Semiconductors. Translation supervised by Kazuo Nojiri Translation by Yuki Ikezi

O 2 SENSORS Zirconium Dioxide (ZrO 2 ) Oxygen Sensor Installation, Operation and Compatibility Guide

Breast Ultrasound QA Phantom Recommended by Japan Association of Breast and Thyroid Sonology

SCANNING ELECTRON MICROSCOPE (SEM) INSPECTION OF SEMICONDUCTOR DICE. ESCC Basic Specification No

Micro Analytical Instruments - A System Approach. Jörg Müller Institut für Mikrosystemtechnik

DN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm)

TYPE SE and TSE, SILICON CARBIDE SPIRAL HEATING ELEMENTS

Context Development Details Anticipated Effects

HPR-30 Vacuum Process Gas Analyser A differentially pumped RGA system for vacuum process monitoring

Capacitive Proximity Sensor

5.4 Production of the R.F. Magnetic Field 5.11

Application Note Silicon Flow Sensor SFS01

RCM DIRECT READING FLOWMETER

LUXAR Anti reflective coated glass Handling Procedures for LUXAR

FIELD EFFECT TRANSISTOR (FET) 1. JUNCTION FIELD EFFECT TRANSISTOR (JFET)

MOSFET & IC Basics - GATE Problems (Part - I)

PID Temperature Control Improvement of Semiconductor Furnace Using Fuzzy Inference

Micro-manipulated Cryogenic & Vacuum Probe Systems

MEMS in ECE at CMU. Gary K. Fedder

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

UFNF YES Image Reversal & HMDS Oven Revision 6.0 1/22/2014 Page 1 of 5. YES Image Reversal and HMDS Oven SOP

DK Guard Ring Polarographic Cell

True Three-Dimensional Interconnections

High Voltage Engineering

Sensors & Transducers Published by IFSA Publishing, S. L., 2016

Properties of a Detector

Cressington 108 Auto/SE Sputter Coater Standard Operating Procedures (S.O.P)

M-DW1. Wafer Mapping Sensor. The safe LED beam reflective type wafer mapping sensor. Safe LEDs adopted. Sensing of nitride-coated wafers possible

Plasma Enhanced Chemical Vapor Deposition (PECVD) of Silicon Nitride (SiNx) Using Oxford Instruments System 100 PECVD

USER MANUAL FOR VISIBLE SPECTROPHOTOMETER

OpticaI=Emissiori Spectroscopy For Plasma Processing

Transistor was first invented by William.B.Shockley, Walter Brattain and John Bardeen of Bell Labratories. In 1961, first IC was introduced.

Diode Laser Systems In Gas Measurement

PrismaPlus. The New Mass Spectrometer with the Added Plus! Modular Design. Powerful Software. Wide Range of Applications.

Supporting Information. Filter-free image sensor pixels comprising silicon. nanowires with selective color absorption

Plasma diagnostic in an inductively coupled plasma using chlorine chemistry

Residual Gas Analyzers RGA100/200/ amu, 200 amu and 300 amu RGAs

Lecture 7. Lithography and Pattern Transfer. Reading: Chapter 7

TESLA RF POWER COUPLERS DEVELOPMENT AT DESY.

Specification of the varied-line-spacing plane grating. monochromator for the TPS port-24 beamline at NSRRC

Residual Gas Analyzers

Effect of Corona Treatment on Spreading Behavior of UV Ink over Inkjet Printed Silver Nano-Particle Layer

DavidsonSensors. Fiber Optic Sensing System Definitions. Davidson Fiber Optic Sensing System

Transcription:

FFeature Article Article Makoto MATSUHAMA Concerning the dry process of the semiconductor device manufacturing, the monitoring of etching chamber conditions (pressure, temperature, gas concentration,...) is crucial. This time, as a study of a new application, we examined the etching chamber management by using the residual gas analyzer. Generally using a residual gas analyzer in a dry etching apparatus which uses halogen-containing gas has been being avoided because of concerns such as sensors life. By confirming the residual gas component in the chamber before etching, it was possible to illuminate the cleaning process. Introduction The HORIBA Advanced Technology Center, established in 015, integrated its semiconductor business-related clean rooms and combined the technologies of the HORIBA Group for promoting the internal production of key components as the core technology and the development of applications of their own. In this report, the study results of the evaluation conducted on a dry etcher using chlorine gas (Model: RIE-00iP, manufactured by Samco Inc.) among the various types of dry etcher we have by installing a residual gas analyzer from the QL-MS01 series manufactured by HORIBA STEC (hereinafter referred to as RGA [Residual Gas Analyzer] ) are introduced as follows: The objective of this study In the dry process included in semiconductor device manufacturing processes, the management of the condition of etching chamber becomes an important element in controlling such processes. In the past, we recommended the use of differential evacuation and avoided installing an RGA directly into an etching chamber for the process using halogen gas because of the concern over sensor lifetime. This time, we conducted the evaluation by directly installing an RGA in dry etcher using halogen gas with cooperation from an equipment manufacturer. By managing the condition of an etching chamber using an RGA quantitatively, we studied the reduction of equipment startup time after an overhaul, the saving of labor required to condition the etching chamber, and the improvement of the quality of etching process for the purpose of optimizing the equipment operation methods based on our empirical rules. The evaluation was conducted with the following procedures: First, the observation of residual gas components during vacuuming after the overhaul of the etching chamber (washing of parts in the etching chamber), next, the verification of the influence on the etching chamber conditioning process and the etched shape, and then, the verification of the influence of residual moisture content in the etching chamber on the etched shape. Equipment used Figure 1 shows the RGA installed in the ICP dry etcher. The RGA was mounted directly to the port on the etching chamber side with no modification and was monitored directly. At the time of this installation, the temperature of the external wall of the etching chamber was regulated at 70 C, and the periphery of the sensor on the RGA was heated to 100 C using a heater to prevent gas from being absorbed into the periphery of the sensor. A manual gate valve was placed between the sensor and the etching chamber to isolate it from the atmosphere in the etching chamber during the process to protect the sensor. RGAs are utilized in plasma and aging treatments using a vacuum etching chamber, as well as management of the gas process at the functional thin membrane formation and working processes. [1] This device, which is 0 times smaller than others, has achieved the compact sensor size as small as 5 cm, which is the smallest level in the world, is equipped with the sensor that is calibration-free and can be replaced by users, and enables low-vacuum measure- 1 English Edition No.7 June 017

Technical Reports (a) (b) RGA (Q-MASS) RGA 70 C@Chamber wall Etching chamber 100 C@GAS SENSOR 00 C@Electrostatic chuck Figure 1 (a) RGA set up (b) The heating temperature in the system ment. This time, we used a sensor for halogen gases. The dry etcher used in the evaluation was the load-lock type equipment for wafers up to inches, intended for high-precision, high-uniformity processing of various semiconductors and insulating films for small-scale research and development. This equipment is equipped with an ICP source that can generate high-density plasma at low pressure and is intended for InP and III/V compound semiconductor devices that use Cl, SiCl, and Ar as process gas. Dry etcher operating methods before conducting this study Table 1 shows the flow of operation of the dry etcher before this study. Oxygen plasma cleaning of the etching chamber is performed before being opened to the atmosphere to minimize residual chloride components as a pretreatment before the overhaul of the etching chamber. After the etching chamber is opened to the atmosphere, the etching chamber is dismounted, washed with pure water, wiped with ethanol, dried, assembled, and then vacuumed. Since the dry etcher used for this evaluation was a new equipment introduced immediately before the study, the equipment management had not yet been optimized. Therefore, the targeted degree of vacuum was set to a low value, giving first priority to prevent a failure from occurring during the etching process. Although the vacuum achievement level of up to approximately 5 10 - Pa was recommended as the background level by the equipment manufacturer, we started the operation of this equipment based on the vacuum achievement level of 10 - Pa as the initial control value due to fear of a process failure caused by residual moisture. Although vacuuming for -8 hours achieved the vacuum of 5 10 - Pa, it required approximately 80 hours to reach the vacuum of 10 - Pa. Verification of the application effect of RGA The results of the verification of the equipment maintenance and process management conditions are as follows: The observation of the etching chamber condition during vacuuming was performed after the overhaul of the etching chamber. The measurement was started at the vacuum of 0.1 Pa where the RGA is operable. Figure shows the passage of 96 hours up to the vacuum of 10 - Pa at Table 1 Work procedure of the chamber overhaul and start-up Phase Reactor Operation Period (hr) Issue Pre-treatment of the chamber pressure release (oxygen plasma cleaning) ATM Chamber overhaul (parts cleaning) Expose Cl 80 Long recovery time Condition management 1 3 ATM Vacuum start ATM -- E- (Pa) Pre Etching Process Post-Maintenance of the chamber (O Cl/Ar plasma cleaning) 5 Etching Process Ref wafer Product wafer Quality control Process stability English Edition No.7 June 017

Feature Article Figure Pump down monitoring which the process can be started as well as the spectrums of residual gases at three vacuum start-up stages among which there is a difference in the degree of vacuum of approximately ten times. (The vertical axis shows the pressure and the horizontal axis shows the mass number.) It was confirmed that the degree of vacuum in the etching chamber reached 5 10-3 Pa in approximately 1 hours of vacuuming, but it took 80 hours until it reached 5 10 - Pa. When vacuuming was initiated, the peaks of moisture content, atmosphere, and component washing solution residue were confirmed. Since nitrogen and oxygen levels (blue dashed lines in Figure ) remained unchanged since the initiation of vacuuming, they are considered to be the leakage level as the background of this equipment. Although HCl, which was eliminated during Work 1 (Oxygen plasma cleaning treatment immediately before opening to the atmosphere) shown in Table 1, was observed, it was considered to have reacted with residual chloride, and as a result the components and inner wall of the etching chamber were washed with water and were confirmed to have decreased as the vacuuming process progressed like CO and ethanol absorbed into the inner wall of the etching chamber. In this way, checking the condition of the etching chamber during vacuuming using the RGA to see if the main component is atmosphere or water determines whether there is a leakage or not immediately after vacuuming, and the effect of preventing leakage problems is expected. Next, the conditions of the etching chamber when the etching chamber conditioning treatment (oxygen-chlorine plasma cleaning) were examined, and when it was not conditioned, and the results of etching performed in these conditions were compared (Figure 3). During the conditioning after the overhaul of the etching chamber, organic matter and moisture are eliminated by oxygen plasma cleaning. Next, chlorine plasma cleaning is performed to eliminate residual oxygen. In chlorine plasma cleaning, it was originally assumed that chloride components needed to be supplied stably to the etching process by stabilizing the amount of etching gas absorbed into the inner wall of the etching chamber during the etching process as the inner wall of the etching chamber was coated with chloride components in advance. Although the lack of the cleaning was considered to have a bad influence on the roughness of the etched surface, etched shape, and rate and the selectivity of the mask material, a good etching shape was achieved on both samples. From this result, it was confirmed that conditioning by plasma cleaning was not required under the etching conditions used for this study. Next, in order to confirm the influence of the etching process and residual moisture, the results of residual moisture partial pressure and etching were compared between two different types of conditions between which there was a difference in the achieved degree of vacuum of ten times (Figure ). Based on the above results, the etching process was performed both hours after the initiation of vacuuming (at the vacuum of 1. 10-3 Pa and moisture partial pressure of.5 10 - Pa) and 8 hours after the initiation of vacuuming (at the vacuum of 1. 10 - Pa and 3 English Edition No.7 June 017

Technical Reports Sample 1. After dry-cleaning (Original). Without dry-cleaning Item Judgment criteria Surface Mirror Surface Good (Mirror) Good (Mirror) taper 80-90 degree Good (85 degree) Good (85 degree) Selection ratio More-than 10 11 1 Figure 3 Chamber conditions before etching with/without dry cleaning sample Sample 1. Low-Vacuum. High-Vacuum Item Judgment criteria Surface Mirror Surface Good (Mirror) Good (Mirror) taper 80-90 degree Good (85 degree) Good (85 degree) Selection ratio More-than 10 16 1 Figure Chamber conditions before etching under Low/High degree vacuum state moisture partial pressure of 5. 10-5 Pa) with the etching chamber uncleaned after the overhaul. As a result, a good etching shape was observed on both samples. For all of these reasons, it was confirmed that the etching shape (flatness on crystal surface and taper shape) and the characteristics (selectivity of mask material) were not influenced even if the process were performed at a lower degree of vacuum achieved (1 10-3 Pa) than had been originally estimated ( 10 - Pa). The reason why good etching results were obtained in this study is considered. Originally, there were concerns that English Edition No.7 June 017

Feature Article the micromask formed on the etched sample surface due to residual moisture had a negative influence on the process when etching an ln-based material using chlorine gas, such as a lawn-like rough surface and variation in verticality or etching rate due to a change in the side protection condition. [] The results obtained this time showed that such an event did not occur. This is considered to be because no moisture was left on the samples as the sample temperature during etching was as high as 00 C and SiCl, as well as Ar used as etching gases, eliminated oxides on the surface. From the above results, it was confirmed that the original equipment management conditions shown in Table 1 were excessive as the process conditions used for this study, the action limit for the achieved degree of vacuum could be smaller by ten times, and the implementation of plasma cleaning for long hours using oxygen and chlorine was not required. The above evaluation made it possible to reduce the time required until the etching chamber becomes usable by 98%, from 8 hours after overhaul to hours after overhaul. For example, even if the etching chamber is opened to the atmosphere in the morning, it can be usable in the afternoon. Since it is also possible to shorten the time required for restoration in the event of a failure of the etching chamber, it became easier to check the condition inside the etching chamber when a failure occurred. In this way, it was confirmed that quantitative equipment management using an RGA could improve the efficiency of operation. Conclusion The effects of the quantification of equipment management and the study of the etching mechanism were confirmed through the application of an RGA to the dry etching process. It was also found that clarifying the condition of residual gas in the etching chamber enabled the detection of a failure early and prevented an etching process failure. Thus, through this evaluation, RGA was confirmed to be effective in optimizing the conditions for managing chlorine-base dry etchers. Acknowledgements Finally, I would like to thank Mr. Hirohiko Nakano and Mr. Hirokazu Terai of the Production Engineering Department of Samco Inc. and Mr. Yohei Sakano of the Development Department of Samco Inc. for valuable discussions and making useful suggestions on the etching process and management of dry etchers for this study. References [ 1 ] T.IKEDA, Readout, 8, 1 (00) [ ] T.TOKUYAMA, (Semiconductor Dry Etching Technology), ISBN-13: 978-788568, (Sangyo- Tosho Co.) (199) Makoto MATSUHAMA Advanced R&D Center HORIBA, Ltd. 5 English Edition No.7 June 017