M = Maintained S = Spring Return. Operator Only ➊ No Contacts M M 800T-00HX2KB6 M M 800T-24HR2KB6AX 800T-24HR17KB6AX Incandescent

Similar documents
800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only)

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

Bulletin 800R 30.5 mm Push Button Stations Hermetically Sealed for Division 2/Zone 2

Allen-Bradley Spares

Bulletin 800H mm Mounting Hole Type 4/4X/13 Corrosion-Resistant/ Watertight/Oiltight Heavy Industrial Stations and Operators TABLE OF CONTENTS

Bulletin 800MR/800MB Push Buttons

150 C 30 F B D 8L 152H C 30 F BD 43 8L

1.3. Pushbuttons and Indicating Lights.

Switches & Pilot Devices

Accessories. Accessories

Bulletin 800FC 22.5 mm Configured Pendant Stations Product Overview. Position 1... Position 9

SEALED, ILLUMINATED ROCKER SWITCHES

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35

Control Stations ø 22

Complete units: Selector switches ø 22mm

Complete units: Push-buttons ø 22mm

Complete units: Mushroom heads ø 22mm

PUSHBUTTON SWITCH / SELECTOR SWITCH / ILLUMINATED PUSHBUTTON SWITCH PSA, LPSA TYPE

Operator Heads: ø 22mm

Round Indicator Lights Mounting Hole Page

L25 Incremental Optical Encoder


Pushbutton Units Flush, Extended, Mushroom Head or Jumbo Mushroom Head Operators. Flush Button. Catalog Number

Separate units: Blocks

General Specifications

Operator Heads: ø 22mm

Bulletin 800MR/800MB Push Buttons

A W - A 2A R - 24D - 1

Distinctive Characteristics

and signalling units Ø 22 1 Harmony XB7 Monolithic pushbuttons, switches and pilot lights

General-Purpose Photoelectric Sensor

Flag indicator. Units. V Resistive Resistive Resistive HP HP Pilot Duty ma ~ ~ ~ ~ V V VA W. (Resistive) ms Vrms Vrms Vrms. C C g-n g-n. grams 1.

Installation Instructions

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

MT5C/8C Ø56mm / Ø85mm Steady & Flashing with Buzzer

.152 (3.86) KEYWAY DEPTH .033 (.84).066 (1.68) .550 DIA (13.97) MOUNTING SURFACE .350 (8.89) 3/8-32 UNEF-2A THREADS (19.71.

Section. Display Lights. Selection Guides... C 2. SignaLight Towers... C 4

67TD Series - Miniature Time Delay Relays DPDT, 4PDT, 5 Amp

Hexa Multi Module 366HMM. Introduction. Design Specifications. Key Features

Ledex Tubular Linear Solenoids

1.7. Pushbuttons and Indicating Lights. Standards and Certifications UL Listed File No. E CSA Certified File No. LR68551

Model Number Structure

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

DCM20 Series. Three-Function DC Power Meters. DCM20 DISPLAY PRODUCT OVERVIEW FEATURES

For more information, please visit or call toll free at

TWTD Series: Heavy duty switches built to last

Fig. 5 Fig. 4. Fig. 11. Fig. 10. Amps Color. Style. Pl Pin Pl RC SqB RC SqB Pin Pin RC RC RC RC RC RB SqB RqB RqB RC

Section. Display Lights Selection Guides... C 2. SignaLight Towers 70mm LT7 Modular Series... C 4 56mm LT1 Series...

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

SERIES WW24 Industrial Wirewound Rotary Potentiometer 24mm Diameter / 5 Watts

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton

ID/HX-EP SERIES DIGITAL OUTPUT

G-Series Servomotors. AC Brushless Servomotors. Understanding the G-Series Servomotor Model Numbers

Set model No. ESN-T8. 140mm ESN-T mm ESN-T mm ESN-T mm. Light axis interval: 20mm. Smallest detectable object diameter: 30 mm

PD140FNT60QMU-02C. Through Beam. Main features. Description

HX-EP SERIES DIGITAL OUTPUT

SELF-CLINCHING STUDS AND PINS

General Specifications

OMRON MK-I / -S RELAY

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

POWER RELAYS CONTINUOUS DUTY, TYPE II, UNSEALED INTERMITTENT DUTY, TYPE III, UNSEALED

Installation and Assembly: Full Service Video Wall Mount

Laser Displacement Sensor Z4M. Ordering Information

Dual Reversing Module

Installation and Assembly: Flat Video Wall Mount For 40" to 65" Flat Panel Displays

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550

Signaling Lights. SLC40 Series Panel Mounted Annunciators. SLC 40 Series Annunciators

Installation Instructions (For Dealer or Contractor)

HMI Components. Series. Flush design Raised design PCB (with adaptor) Indicator Pushbutton Illuminated pushbutton

Sorenson Lighted Controls

Dispozitive de acţionare şi indicatori

A great addition to Sub-Zero's complete line of

MINIATURE RELAY FOR WIDER APPLICATIONS

.062 [1.57] Commercial Pin and Socket Connectors

Installation and Assembly - Articulating Swivel Double-Arm for 42" - 71" Plasma Screens

PD30ETD10xxSA. Photoelectrics, Diffuse reflective. Main features. Description

Custom Wood Frame Overlay for Glass Doors Installation Instructions

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features

Timers RTE. RTE Series Analog Timers

General Specifications

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

PRODUCT SPECIFICATION

Installation and Assembly: Flat \ Tilt Wall Mount for VESA 400x400

General-purpose Relay

200 Watt Passive Shunt Module

Installation Guide Guide d installation

DRILLING CATALOG. GRAINGER.COM/CHOICE l Grainger

SPST-NO SPDT DPST-NO DPDT

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

OB1U INSTALLATION INSTRUCTIONS. Interactive Flat Panel Over White Board Mount

General-purpose Relay

[3] MOUNTING DIRECTION

SLIDING DOOR LOCKS MISCELLANEOUS

General Specifications

Snap Action Switches Technical Guide

XXXX e. X d.. X X X a

NX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13.

Transcription:

ulletin 800T 30.5 mm Push uttons 2-Position Knob/Lever Type Selector Switch Units, Illuminated Operator Position Operator Type Standard Knob Knob Lever Type Lamp Volts olor M = Maintained S = Spring Return Operator Only No ontacts M M 800T-00H2K6 M M 800T-24HR2K6 800T-24HR7K6 S M ➋ 800T-24HR4KL8 800T-24HR8KL8 Full Voltage Transformer M S 800T-24HR5KL8 800T-24HR9KL8 24 /D Red O M M 800T-24HRH2K6 800T-24HRH7K6 O S M ➋ 800T-24HRH4KL8 800T-24HRH8KL8 M S 800T-24HRH5KL8 800T-24HRH9KL8 No Lamp 0 250 /D No Knob M M 800T-25HN2K6 M M 800T-6HR2K6 800T-6HR7K6 S M ➋ 800T-6HR4KL8 800T-6HR8KL8 M S 800T-6HR5KL8 800T-6HR9KL8 20 Red O M M 800T-6HRH2K6 800T-6HRH7K6 50/60 Hz O S M ➋ 800T-6HRH4KL8 800T-6HRH8KL8 M S 800T-6HRH5KL8 800T-6HRH9KL8 No Lamp No Knob M M 800T-6HN2K6 Note: = losed/o = Open Standard Knob Operator 800T-6HR2K6 Knob Lever Operator 800T-6HR7K6 0 3-Position Knob/Lever Type Selector Switch Units, Illuminated Operator Position Operator Type Standard Knob Knob Lever Type Lamp Volts olor M = Maintained S = Spring Return Operator Only No ontacts M M M 800T-00J2K7 M M M 800T-24JR2K7 800T-24JR7K7 S M M 800T-24JR4K7 800T-24JR8K7 Full Voltage Transformer Note: = losed/o = Open 0-30 Standard Knob Operator 800T-6JR2K7 Knob Lever Operator 800T-6JR7K7 M M S 800T-24JR5K7 800T-24JR9K7 24 /D Red O O M M M 800T-24JRH2K7 800T-24JRH7K7 O O S M M 800T-24JRH4K7 800T-24JRH8K7 M M S 800T-24JRH5K7 800T-24JRH9K7 No Lamp 0 250 /D No Knob M M M 800T-25JN2K7 M M M 800T-6JR2K7 800T-6JR7K7 S M M 800T-6JR4K7 800T-6JR8K7 M M S 800T-6JR5K7 800T-6JR9K7 20 Red O O M M M 800T-6JRH2K7 800T-6JRH7K7 50/60 Hz O O S M M 800T-6JRH4K7 800T-6JRH8K7 M M S 800T-6JRH5K7 800T-6JRH9K7 No Lamp No Knob M M M 800T-6JN2K7 Operator only supplied without power module, lamp, lens cap, or contact blocks. ccessories Page 0-37 Legend Plates Page 0-48 ➋ Target tables are reversed from those shown. pproximate Dimensions Page 0-5

2- and 3-Position Knob/Lever Type Selector Switch Units, Illuminated ulletin 800T 30.5 mm Push uttons 800T 6 J R 2 K7 a b c d e f g h i First Level Second Level lank a Finger-Safe Guards No Guards Guards on Terminals b Power Module Type and Voltage 6 6V /D 2 2V /D 24 24V /D 32 32V /D 48 48V /D 0 20V /D 3 30V /D Transformer 36 48V 50/60 Hz 6 20V 50/60 Hz 26 240V 50/60 Hz 76 277V 50/60 Hz 46 480V 50/60 Hz 56 600V 50/60 Hz H J c No. of Positions 2-Position 3-Position G R W lank H d Knob olor e f olor mber lue lear Green Red White No Knob Illumination Options ➋ and Knob Type Standard Knob or No Knob 2 Maintained 4 Spring Return from Left 5 Spring Return from Right 9 Spring Return from oth ➌ Knob Lever 7 Maintained 8 Spring Return from Left 9 Spring Return from Right 20 Spring Return from oth ➌ K6 KL8 K7 K K7 KE7 KQ KT lank (both pos.) D E G J M N H U I Q F g am Options 2-Position Maintained am Spring Return am 3-Position h, i 7 am am 7 am E7 am Q am T am ontact locks ➍ No ontacts on operator Standard N.O. N.. N.O.E.M. N..L.. N.O. - N.. 2 N.O. ➎ 2 N.. N..L.. - N.O. N..L.. - N.. PenTUFF (Low Voltage) N.O. N.. N.O.E.M. N..L.. N.O. - N.. h, i (cont d) ontact locks ➍ lank (both No ontacts on operator pos.) lass, Div. 2/Zone 2 Logic Reed V W T Y Z R S P N.O. N.. N.O. - N.. 2N.O.➎ 2N.. Sealed Switch N.O. N.. N.O. - N.. Stackable Sealed Switch 5 N.O. 6 N.. 8 2 N.O. 9 2 N.. 7 N.O. - N.. Table. Selector Switch am Targets am (2-Position) Target ontact lock ➏ O O S,6 Note: = losed/o = Open Target O O O O O O am (3-Position) K7 K K7 KE7 KQ KT D, H, V E,U,W,S,6 O G, I J, Q J, Q O J,Q J,Q E,U,W,S,6 O G,I G,I D,H,V,R,5 Note: = losed/o = Open Table 3. ontact lock Reduction Rules ontact lock Substitution ombination Standard D+E D+D M ➎ E+E N D+J E+J PenTUFF (Low Voltage) H+U V+W V+V W+W F T Y ➎ Z only. ➋ s available in red, green, amber, blue, and white. White s only available in 6V and 24V full voltage and all transformer units. color must match lens color, except clear lens supplied with white and white lens supplied with amber. ll s except 20V have an internal shunt resistor for use with solid-state outputs. ➌ 3-position only. ➍ ontact blocks used on white side only. ➎ 2 and 2R contact blocks cannot be stacked upon, but they can stack on other contact blocks. ➏ Target tables are reversed for spring return from left operators. 0-3

Replacement Lamps Pilot Lights, Illuminated Push uttons, Illuminated Push-Pull, Illuminated Push-Pull/Twist to Release Illuminated Selector Switches ulletin 800T 30.5 mm Push uttons Lamp Type Typical urrent Lamp Voltage NSI No. 50 m 6 /D 755 800T-N65 80 m 2 /D 756 800T-N4 70 m 24 /D 757 800T-N57 50 m 48 /D 835 800T-N365 22 m 30 /D 949 800T-N69 Transformer 50 m 6 755 800T-N65 Flashing 50 m 6 267 800T-N22 Resistor 22 m 30 /D 949 800T-N69 Dual-Input Diode 57 m 24 /D 24M 800T-N80 2 m 20 90M 800T-N26 Dual-Input Transformer 50 m 6 755 800T-N65 Neon 2 m 20 /D 2 609-N9 Lamp Type Typical urrent ➋ Lamp Voltage Leakage urrent 4 m/48 m 6 /D 4 m 800T-N38x ➍ 3m/22m 2/D 3.5m 800T-N362x ➍ ➌ 3m/2m 24/D 3.5m 800T-N39x ➍ 2m/7m 32/D 3m 800T-N363x ➍ 9 m/4 m 48 /D 3 m 800T-N364x ➍ 3.3 m/6 m 20 800T-N320x ➍ 4.5 m/6.2 m 30 /D 2.2 m 800T-N32x ➍ Transformer 4 m/48 m 6 4 m 800T-N38x ➍ Flashing 8 m 24 /D 800T-N39Fx ➍➎ Lamp Type Typical urrent Lamp Voltage NSI No. 50 m 6 /D 755 800T-N65 80 m 2 /D 756 800T-N4 70 m 24 /D 757 800T-N57 Transformer 50 m 6 755 800T-N65 Lamp Type Typical urrent ➋ Lamp Voltage Leakage urrent 4 m/48 m 6 /D 4 m 800T-N38x ➍ 3m/22m 2/D 3.5m 800T-N362x ➍ ➌ 3m/2m 24/D 3.5m 800T-N39x ➍ 2m/7m 32/D 3m 800T-N363x ➍ 9 m/4 m 48 /D 3 m 800T-N364x ➍ 3.3 m/6 m 20 800T-N320x ➍ 4.5 m/6.2 m 30 /D 2.2 m 800T-N32x ➍ Transformer 4 m/48 m 6 4 m 800T-N38x ➍ Flashing 8 m 24 /D 800T-N39Fx ➍➎ luster Pilot Lights Lamp Type Typical urrent Lamp Voltage NSI No. 95 m 6 /D 38 800T-N258 73 m 2 /D 382 800T-N259 37 m 24 /D 387 800T-N260 Transformer 95 m 6 38 800T-N258 Lamp Type Typical urrent Lamp Voltage Polarity 45 m 6 /D Positive 800T-N340x ➍ 36 m 2 /D Positive 800T-N34x ➍ 4 m 28 /D i-polar 800T-N80x ➍ Transformer 45 m 6 Positive 800T-N340x ➍ Item is sold in multiples of 5. Order quantity of 5 to receive package of 5 pieces. ➋ Typical current draw varies with color. The first m value is for a green or blue and the second m value is for a red or amber. ➌ ll s except 20V have an internal shunt resistor for use with solid-state outputs. s will not illuminate below listed leakage current. ➍ To complete the cat. no. replace the x with the first letter of the desired color: mber, Green, Red, lue, or White. White s only available in 6V and 24V. ➎ Flashing rate is 2 Hz. 0-47

pproximate Dimensions and Shipping Weights Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Mounting Instructions for Push uttons with Shallow locks, Mini locks, Logic Reed locks, Sealed Switch locks and Time Delay locks (see footnotes for exceptions) 3 / 64 (30.6) Dia. / 4 Dia. Drill (6.4) 9 / 6 (4.3) 27 / 32 (46.8) ➋ 27 / 32 (46.8) / 4 Dia. Drill (6.4) 9 / 6 (4.3) 3 / 64 (30.6) Dia. ulletin 800T 30.5 mm Push uttons Sketch illustrates the minimum distance between centerlines when mounting ulletin 800T controls either side by side, facing each other or one above the other. When control units are mounted so that the contact block terminals face each other, the 2-/4 (57.2) dimension must be used in order to get proper electrical clearance. When control units are mounted so that the contact block terminals do not face each other, the -27/32 (46.8) dimension canbeused. hange to 2-/4 (57.2) for transformer type pilot light, push-to-test pilot lights, illuminated selector switches and all push-pull buttons. Note: Large legend plate requires minimum horizontal spacing of 2-5/32 (62.7). ➋ Vertical minimum spacing dimension changes for the following legend plates: Jumbo 2-5/32 (62.7); large 2-7/6 (6.9); cluster pilot light and 2-3-4 way switches 2-/6 (52.4). Panel Thickness Kits are shipped with three /6 (.58) gaskets. Refer to table below for number of washers required for various panel thicknesses. /6 (.6) (6 Gauge) 7/64 (2.8) (2 Gauge) 9/64 (3.6) (0 Gauge) 3/6 (4.8) Panel 3 Washers 2 Washers Washer Thicker Than 3/6 (4.8) Panel ounterbore to 3/6 (4.8) Typical Panel ut-out Legend Plate Dimensions Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes..09 (2.3).8 (4.6) 25 / 32 (45.2) 25 / 32 (45.2) 2 7 / 6 (6.9) 9 / 64 (29) 53 / 64 (46.4) 3 / 4 (44.5) 2 27 / 64 (6.5) 39 / 64 (40.9) 2 3 / 32 (6.) Standard Legend Plate Jumbo Legend Plate Large Legend Plate (utomotive Industry Type) 2 7 / 6 (6.9) 25 / 32 (45.2) 39 / 64 (40.9) 2 3 / 32 (6.) 2 9 / 6 (65.) 5 / 32 (29.4) 2 / 32 (5.6) Large Size Push-Pull/Twist Legend Plate 800T-647 ➌ Round 800T-646 ➌ luster Pilot Light and 2-3-4 Way Switch Silver Legend Plate 800T-69 ➌ For panel mounting only. Not for use with llen-radley enclosures. 0-5

ulletin 800T 30.5 mm Push uttons pproximate Dimensions and Shipping Weights, ontinued Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Pilot Light and Illuminated Devices, Neon and Dual Input Pilot Light Transformer Type Pilot Light 29 / 32 (48.4) 2 3 / 32 (55.6) 3 / 6 2 / 32 (5.6) Shipping Wt. 5 oz. (0.4 kg) luster Pilot Light 9 / 32 (32.5) 23 / 32 (43.7) 2 5 / 32 (54.8) Shipping Wt. 8 oz. (0.22 kg) 9 / 32 (32.5) Dual Input Transformer Type Pilot Light 7 / 8 (47.6) 2 / 32 (59.5) 5 / 8 (4.3) 2 7 / 6 (6.9) (25.4) Shipping Wt. 2 oz. (0.34 kg) Transformer Type (Push-to-Test Pilot Light and Illuminated Push utton) 45 / 64 (43.2) 2 3 / 64 (63) 9 / 32 (32.5), Neon and Dual Input Type (Push-to-Test Pilot Light and Illuminated Push utton) 2 / 4 (57.2) 2 3 / 6 (55.6) 0 3 / 6 5 / 32 (37.3) Push-Pull and Twist or Pull Release Units (Transformer Type Illuminated) 3 / 6 5 / 32 (37.3) Push-Pull and Twist or Pull Release Units (, Neon and Dual Input Illuminated and ll Non-Illuminated) 2 / 4 (57.2) 5 / 8 (4.3) Dia. 2 3 / 6 (55.6) 5 / 8 (4.3) Dia. 3 / 6 7 / 6 (36.5) 3 / 6 7 / 6 (36.5) Push-to-Test Pilot Lights Non-Illuminated Push-Pull uttons Illuminated Push uttons and Illuminated Push-Pull uttons or Neon Transformer Type Transformer Type Type Suffix ➋ Suffix Dim. Ship. Wt. Dim. Ship. Wt. Dim. Ship. Wt. D4 and 7 P DP D2P 0-54 Transformer or Terminal Module and One Shallow ontact lock Transformer or Terminal Module and One Shallow lock and One Mini ontact lock Transformer or Terminal Module and One Sealed Switch ontact lock 2-5/32 (54.8) ➌ 2-7/8 (73) 3-/32 (77) 9oz. (0.25 kg) 0 oz. (0.28 kg) 0 oz. (0.28 kg) Jumbo mushroom versions are 2-/4 (57.2) diameter. ➋ pplies to illuminated push-pull push buttons only. 2-/32 (5.6) 2-7/8 (73) 2-29/32 (73.8) 7oz. (0.25 kg) 8oz. (0.22 kg) 8oz. (0.22 kg) D4 4 5 7 6 One Shallow ontact lock Two Shallow ontact locks Two Shallow locks and Two Mini ontact locks 2-/32 (5.6) 2-/32 (5.6) 2-7/8 (73) ➌ Dual input type pilot light dimension is 2-3/32 (6.). 5oz. (0.4 kg) 6oz. (0.7 kg) 8oz. (0.22 kg)

Specifications ontact ratings Dielectric strength Electrical design life cycles Vibration Shock Degree of protection Mechanical design life cycles Push buttons Selector switches Potentiometers ll other devices ontact operation Typical operating forces Operators without contact blocks Performance Data See page Important-2. (Momentary, non-illuminated) (Momentary, illuminated) (Push-pull/twist-to-release) (Non-illuminated) (Illuminated, key-operated) Spring return selector switches Illuminated push buttons and push-to-test pilot lights 2-position push-pull 3-position push-pull Twist-to-release or push-pull Potentiometer 800T- Logic Reed ontact blocks Sealed switch Stackable sealed switch Operating Temperature range Storage Note: Operating temperatures below freezing are based on the absence of moisture and liquids. onsult your local llen-radley Sales Office for use in lower temperature applications. Humidity Standard ontact Ratings Maximum thermal continuous current I th 0 /2.5 D. ulletin 800T units with 800T- contacts have ratings as follows: Max. Opertnl. Volts Ue Utilization ategory Rated Operational urrents IE NEM Volts Ue Make reak 20 600 7200 V 720 V 72 20 60 720 V 24 72 60 0 600-5 600 D 600 D-3 Q600 28 600 24 28 ➋ ➋ For applications below 24V/24 m, PenTUFF or Logic Reed contacts are recommended. Sealed Switch ontact Ratings Maximum continuous current I th 5.ulletin800Tunitshavecontrol circuit ratings with sealed switch contact blocks as follows: Stackable Sealed Switch ontact Ratings Maximum continuous current I th 2.5. Logic Reed ontact Ratings Maximum D: 30V, 0.06, : 50V, 0.5 Shouldonlybeusedwithresistiveloads. 69 V 2.5 Max. Opertnl. Utilization ategory Rated Operational urrents Volts Ue IE NEM Volts Ue Make reak 20 600 3600 V 360 V 600-5 600 0 20 30 3 D 300 D-3 P300 24 300 0 24 38 V 5.0 ulletin 800T 30.5 mm Push uttons Electrical Ratings Refer to the contact ratings tables below. 2200V for one minute, 300V for one minute (Logic Reed),000,000 at max. rated load, 200,000 at max. rated load (Logic Reed) Mechanical Ratings 0 2000 Hz.52 mm displacement (peak-to-peak) max./0 G max. (except Logic Reed) /2 cycle sine wave for ms 25 G (contact fragility) and no damage at 00 G Type /4/2/3; watertight/oiltight IE 529 IP66/65 (Series T only) 0,000,000 min. 250,000 min. 250,000 min.,000,000 min. 200,000 min. 00,000 min. 200,000 min. Shallow, mini, and low voltage contact blocks: Slow, double make and break Logic Reed and sealed switch contact blocks: Single break magnetic Flush, extended, standard mushroom, jumbo plastic mushroom: 2 lbs max. Jumbo and extended aluminum mushroom head: 3.95 lbs max. Maintained selector switch: 3.6 in. lbs max. 3.6 in.-lbs to stop, 0.2 in.-lbs to return 5 lbs max. 7.5 lbs max. push or pull 8 lbs max. push to in position or pull to center position (5 lbs max. pull to out position) 9 lbs max. push or pull 30 in. oz. max. twist, 6 in. oz. minimum return Rotational torque 3 2 in.-oz.; stopping torque 2 in.-lbs (minimum) lb lbmax. 3 lbs max. at 0.205" plunger travel lbmax. Environment 40 +3 F ( 40 +55 ) 40 +85 F ( 40 +85 ) 50% at +04 F (+40 ) PenTUFF (Low Voltage) ontact Ratings Minimum D: 5V, m Maximum thermal continuous current I th 2.5 /.0 D. ulletin 800T units with 800T-V contacts have ratings as follows: Max. Opertnl. Utilization ategory Rated Operational urrents Volts Ue IE NEM Volts Ue Make reak 300-5 300 20 300 800 V 80 V 0 20 5.5 D 50 D-3 R50 24 50 28 V 0 24.0 Snap ction ontact Ratings Max. Opertnl. Volts Ue 300 Time Delay ontacts.ontact Rating Designation 300 D 250 Note: This device is not rated for D applications. djustment range: 0.5 5 s ± 25% I th = 5 pprovals UL Listed File: E4840, E034 Guide: NKR, NOIV S ertified: LR234, LR924 E ompliant IE: 60947-5- Rated Operational urrents Volts Ue Make reak 20 300 7200 V 720 V 24 72 60 0 230 250 0.2 5 25 0.4 Max. Opertnl. ontact Rating Rated Operational urrents Volts Ue Designation Volts Ue Make reak 20 50 20 3600 V 360 V 0-5