Steady State Fault Analysis of VSC- HVDC Transmission System

Similar documents
Dynamic Stability Improvement of Power System with VSC-HVDC Transmission

29 Level H- Bridge VSC for HVDC Application

A cost effective hybrid HVDC transmission system with high performance in DC line fault handling

Voltage Control and Power System Stability Enhancement using UPFC

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

IMPORTANCE OF VSC IN HVDC

Improvement of Rotor Angle Stability and Dynamic Performance of AC/DC Interconnected Transmission System

VSC Based HVDC Active Power Controller to Damp out Resonance Oscillation in Turbine Generator System

Available ONLINE

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

High Voltage DC Transmission 2

STATCOM WITH POD CONTROLLER FOR REACTIVE POWER COMPENSATION Vijai Jairaj 1, Vishnu.J 2 and Sreenath.N.R 3

A Review on Improvement of Power Quality using D-STATCOM

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

A New Network Proposal for Fault-Tolerant HVDC Transmission Systems

Analysis the Modeling and Control of Integrated STATCOM System to Improve Power System

Design and Simulation of Fuzzy Logic controller for DSTATCOM In Power System

POWЕR QUALITY IMPROVEMENT IN POWЕR SYSTЕM BY USING SVPWM BASED STATIC SYNCHRONOUS SЕRIЕS COMPЕNSATOR

Improvement Voltage Sag And Swell Under Various Abnormal Condition Using Series Compensation

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

Power System Reliability and Transfer Capability Improvement by VSC- HVDC (HVDC Light )

Power Quality Improvement using Hysteresis Voltage Control of DVR

Modelling And Analysis of DVR With SEPIC Converter And Supercapacitor

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

Fundamental Concepts of Dynamic Reactive Compensation. Outline

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

PUBLICATIONS OF PROBLEMS & APPLICATION IN ENGINEERING RESEARCH - PAPER CSEA2012 ISSN: ; e-issn:

A NEW APPROACH FOR MODELING COMPLEX POWER SYSTEM COMPONENTS IN DIFFERENT SIMULATION TOOLS

Real and Reactive Power Control by using 48-pulse Series Connected Three-level NPC Converter for UPFC

Power Quality and the Need for Compensation

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 07, 2014 ISSN (online):

Mitigating Voltage Sag Using Dynamic Voltage Restorer

Transient Stability Improvement of Multi Machine Power Systems using Matrix Converter Based UPFC with ANN

DESIGN AND DEVELOPMENT OF SMES BASED DVR MODEL IN SIMULINK

CHAPTER 5 CONTROL SYSTEM DESIGN FOR UPFC

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

Simulation Study of a Monopole HVDC Transmission System Feeding a Very Weak AC Network with Firefly Algorithm Based Optimal PI Controller

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

Introduction to HVDC Transmission. High Voltage Direct Current (HVDC) Transmission

ELEMENTS OF FACTS CONTROLLERS

Designing Of Distributed Power-Flow Controller

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Transient Stability Improvement Of IEEE 9 Bus System With Shunt FACTS Device STATCOM

A DYNAMIC VOLTAGE RESTORER (DVR) BASED MITIGATION SCHEME FOR VOLTAGE SAG AND SWELL

ENHANCEMENT OF POWER FLOW USING SSSC CONTROLLER

IJEETC. InternationalJournalof. ElectricalandElectronicEngineering& Telecommunications.

Improvement of Power system transient stability using static synchronous series compensator

Koganti Sri Lakshmi, G.Sravanthi, L.Ramadevi, Koganti Harish chowdary

Modelling of VSC-HVDC for Slow Dynamic Studies. Master s Thesis in Electric Power Engineering OSCAR LENNERHAG VIKTOR TRÄFF

Damping Power system Oscillation using Static Synchronous Series Compensator (SSSC)

Performance of DVR & Distribution STATCOM in Power Systems

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

U I. HVDC Control. LCC Reactive power characteristics

Power Quality improvement of a three phase four wire system using UPQC

VSC-HVDC System Modeling and Validation

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

Control of buck-boost chopper type AC voltage regulator

Compare Stability Management in Power System Using 48- Pulse Inverter, D-STATCOM and Space Vector Modulation Based STATCOM

Power System Stability Enhancement Using Static Synchronous Series Compensator (SSSC)

ISSN Vol.03,Issue.07, August-2015, Pages:

Performance of DVR under various Fault conditions in Electrical Distribution System

Improvement of Power Quality in PMSG Based Wind Integrated System Using FACTS Controller

Voltage Improvement Using SHUNT FACTs Devices: STATCOM

A Novel H Bridge based Active inductor as DC link Reactor for ASD Systems

Designing and Control of Converters used in DPFC for Mitigation of Voltage Sag and Swell In Transmission Line

Comparison and Simulation of Open Loop System and Closed Loop System Based UPFC used for Power Quality Improvement

Implementation of D-STACTOM for Improvement of Power Quality in Radial Distribution System

MMC based D-STATCOM for Different Loading Conditions

A THREE PHASE SHUNT ACTIVE POWER FILTER FOR HARMONICS REDUCTION

Highgate Converter Overview. Prepared by Joshua Burroughs & Jeff Carrara IEEE PES

Improved Transient Compensation Using PI-SRF Control Scheme Based UHVDC For Offshore Wind Power Plant

SIMULATION OF D-STATCOM IN POWER SYSTEM

IJESR/Nov 2012/ Volume-2/Issue-11/Article No-21/ ISSN International Journal of Engineering & Science Research

Development of Multilevel Inverters for Control Applications

SIMULATION OF D-STATCOM AND DVR IN POWER SYSTEMS

Control Strategies and Inverter Topologies for Stabilization of DC Grids in Embedded Systems

A Voltage Controlled D-STATCOM for Power Quality Improvement with DVR

Analysis, Modeling and Simulation of Dynamic Voltage Restorer (DVR)for Compensation of Voltage for sag-swell Disturbances

FUZZY CONTROLLED DSTATCOM FOR HARMONIC COMPENSATION

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Power Quality Compensation by using UPFC

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

Enhancement of AC System Stability using Artificial Neural Network Based HVDC System

Hybrid Simulation of ±500 kv HVDC Power Transmission Project Based on Advanced Digital Power System Simulator

ANFIS based 48-Pulse STATCOM Controller for Enhancement of Power System Stability

INVESTIGATION OF HARMONIC DETECTION TECHNIQUES FOR SHUNT ACTIVE POWER FILTER

THE ALTERNATE ARM CONVERTER: A NEW HYBRID MULTILEVEL CONVERTER WITH DC- FAULT BLOCKING CAPABILITY

Chapter-5 MODELING OF UNIFIED POWER FLOW CONTROLLER. There are a number of FACTS devices that control power system

A Fuzzy Controlled PWM Current Source Inverter for Wind Energy Conversion System

REDUCTION OF THD IN POWER SYSTEMS USING STATCOM

ANALYSIS OF MULTI-TERMINAL HVDC TRANSMISSION SYSTEM FEEDING VERY WEAK AC NETWORKS

Transient Stability Analysis of Multimachine System Using Statcom

MODELING AND ANALYSIS OF IMPEDANCE NETWORK VOLTAGE SOURCE CONVERTER FED TO INDUSTRIAL DRIVES

MODELLING & SIMULATION OF ACTIVE SHUNT FILTER FOR COMPENSATION OF SYSTEM HARMONICS

Power Quality enhancement of a distribution line with DSTATCOM

Modeling and Simulation of Five Phase Induction Motor Fed with Five Phase Inverter Topologies

Literature Review. Chapter 2

1.2 POWER-ELECTRONIC CONVERTERS AND CONVERTER SYSTEMS

Application of Fuzzy Logic Controller in UPFC to Mitigate THD in Power System

Transcription:

International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-56 Volume: 4 Issue: 9 Sep -27 www.irjet.net p-issn: 2395-72 Steady State Fault Analysis of VSC- HVDC Transmission System Virendra Kumar Gupta, Dr. A.S.Pandey 2, Ankit Kumar Srivastva 3 (P.G. Scholar) EE Department KNIT, Sultanpur, U.P. (INDIA) -2288 2 (Professor) EE Department KNIT, Sultanpur, U.P. (INDIA) -2288 3 (PHD Scholar) EE Department KNIT, Sultanpur, U.P. (INDIA) -2288 ---------------------------------------------------------------------***--------------------------------------------------------------------- Abstract - This paper proposes a dynamic model of a VSC (voltage source converter) based Back to Back HVDC system and its control technique. From the system model, the corresponding relationship between the controlling and the controlled variables of the VSC is determined. The vector control technique is used to control the working of converters. Transient instability caused by a system faults overcome due to the fast power run back capability of the VSC-HVDC transmission. VSC-HVDC prevents the system from transient instability by its instant power reversal ability. The voltage support capability of VSC system helps to protect the system from voltage collapse, hence losing of synchronism can be avoided. The entire work has been done in MATLAB/SIMULINK environment. Key Words: VSC, High voltage direct current (HVDC), Modeling, Simulation, Fault Analysis, IGBT, PWM..INTRODUCTION High Voltage Direct Current (HVDC) transmission is the future trend in bulk power transmission.growth of electrical demand in large power systems has been increasing at a faster rate than the expansion of transmission facilities.. The increasing stress on transmission systems is typically manifested by decreasing voltage stability margins in many regions around the world as was the case in the 23 Italy blackout []. Bulk power transfer can be carried out over long distance by a high voltage direct current (HVDC) connection is cheaper than by an HVAC transmission line [2]. The increasing demand for electric power has emerged the integration of renewable energy sources and advanced transmission technologies high voltage direct current (HVDC). The first voltage source HVDC converter was commissioned in 997, Hellsjon, Sweden [3]. The semiconductors used are insulated gate bipolar transistors (IGBTs), and the converters are voltage source converters (VSCs) which operate with high switching frequencies (-2 khz) utilizing pulse width modulation. The VSC-HVDC technology has a higher control capability when compared with the classic alternative, since it can independently control the active and the reactive power exchanged with the connected AC network. Voltage source converters (VSC) have gradually become one of the most attractive solutions for interconnections between AC and DC networks. VSCs have been widely used in many applications, such as integration of renewable energy generation, high voltage direct current (HVDC) transmission and back to back systems, integration of energy storage systems and railway traction systems [4]. There is an additional degree of freedom which make it possible to control the reactive power and the active power independently. Application of such dc links is expected to solve power-quality related problems in industrial power systems.vsc HVDC back to-back arrangement is used when two asynchronous AC systems need to be interconnected for bulk power transmission or for AC system stabilization reasons[4].this arrangement includes a link consist of a back to back voltage sourced converters (VSCs), a common DC link, which includes a large DC capacitors and DC cables. The control strategy is being designed to coordinate the active power control between two station which is realized by controlling the DC side voltage of one converter where other converter control the active power. Automatic control of power flow between stations is the result of a constant DC voltage source gives slack bus. AC voltage control and reactive power control will switched as per the requirement. The active power flow can be controlled by dc voltage or the variation of frequency of ac side or set manually. Thus, the active power flow, the reactive power flow, the ac voltage, the dc voltage and the frequency can be controlled independently using VSC HVDC. The main requirement in a power transmission system is the precise control of active and reactive power flow to maintain the system voltage stability [4]. VSC- HVDC transmission technology has many features such as independent controllability for active and reactive power, commutation failure free, and available for passive system power supply. The electric power grid is experiencing increased needs for enhanced bulk power transmission capability, reliable integration of large scale renewable energy sources, and more flexible power flow controllability [5].The lower stability of power system for frequently and quickly load change may reduce the power system restoration speed in the restoration course using conventional pure AC transmission line path [6]. The capability of rapidly control both active and reactive power independent of each other allows VSC- HVDC to enhanced 27, IRJET Impact Factor value: 5.8 ISO 9:28 Certified Journal Page 698

International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-56 Volume: 4 Issue: 9 Sep -27 www.irjet.net p-issn: 2395-72 transient stability, increase damping of electromechanical oscillations and improve voltage stability [7]. Each converter station is composed of a VSC. The amplitude and phase angle of angle of the converter AC output voltage can be controlled simultaneously to achieve a rapid, independent control of active and reactive power in all four quadrants. The control of both active and reactive power is bidirectional and continuous across the operating range. For active power balance, one of the converters operates on constant active power control. When dc line power is zero, the converters can be considered as independent STATCOM [8]. The VSC applications include but are not limited to HVDC and flexible AC transmission system (FACTS) devices such as STATCOM, SSSC, UPFC, wind generators and active filters. The VSC based HVDC system is a feasible option for high power transmission over long or short distances and the grid integration of renewable energy sources in existing transmission and distribution systems [9]. 2. COMPONENTS OF VSC HVDC SYSTEM VSC-HVDC is a new dc transmission system technology. The converters can be connected in back to back configuration or at either end of a transmission line or cable as schematically shown in figure []. It is based on the voltage source converter, where the valves are built by IGBTs and PWM is used to create the desired voltage waveform. Fig. Block diagram of VSC -HVDC system 2. Converters Converters are made up of power electronic switches. Converters are the main building blocks of HVDC transmission. They perform the conversion from ac to dc (rectifier) at the sending end and from dc to ac (inverter) at the receiving end. HVDC converters are connected to the ac system by means of converter transformers. In this paper, voltage source converter (VSC) is used. The voltage source converter is equipped with self-commutated insulated gate bipolar transistor (IGBT). VSC technology can control active as well as reactive power without affecting each other. 2.2 AC Filters High-pass filter branches are installed to take care of the high order harmonics. With VSC converters there is no need to compensate any reactive power consumed by the converter itself and the current harmonics on the ac side are related directly to the PWM frequency. The amount of loworder harmonics in the current is small. Therefore the amount of filters in this type of converters is reduced dramatically compared with natural commutated converters. 2.3 DC Cables The cable used in VSC-HVDC applications is a new developed type, where the insulation is made of an extruded polymer that is particularly resistant to dc voltage. Polymeric cables are the preferred choice for HVDC, mainly because of their mechanical strength, flexibility, and low weight. 2.4 PWM for VSC To reduce the harmonics in the output voltage waveform Pulse-width modulation (PWM) is the most accepted switching technique.pwm is the basis for control in power electronics. In this paper uni-polar sinusoidal PWM is used. 3. CONTROL OF VSC HVDC SYSTEM The VSC HVDC control system is typically consists of a vector controller. The vector controller is the inner control loop and the outer control loop. The outer control loop includes the DC voltage controller, the AC voltage controller, the active power controller, the reactive power controller. In this paper vector control method is used for better control of the parameters. Active power and reactive power controlled quantities of VSC-HVDC are coupled to each other in such a manner that any change in one of the quantity affects the other and by using the vector control method the coupling between these quantities can be removed so that we have an independent control of each quantity. The vector control strategy consists of a cascade control system with faster inner controllers. The vector controller is accomplished by additional outer current controller which provides the reference values for inner controller. The outer controllers include active power controller, reactive power controller, AC voltage controller, DC voltage controller. 4. DYNAMIC MODELLING CASE STUDIES OF TWO- TERMINAL VSC- HVDC SYSTEM To evaluate the effectiveness of the proposed control scheme, cases of Two-Terminal IGBT VSC-HVDC is developed in MATLAB. The power system simulator or 27, IRJET Impact Factor value: 5.8 ISO 9:28 Certified Journal Page 699

DC Voltage/Ud (pu) Reactive Power (pu) Active Power (pu) International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-56 Volume: 4 Issue: 9 Sep -27 www.irjet.net p-issn: 2395-72 SimPowerSystem toolbox and Simulink are used for system modeling and simulation where VSC station 2 works in VQ control mode and VSC station works in PQ control mode..5.5 P P2 -.5 - Fig. 3 Active power steady state and start-up response. Q Q2 -. -.2 -.3 -.4 Fig. 4 Reactive power steady state and start-up response.4.2 Ud Ud2.8.6.4.2 Fig. 2 Simulink model of the system Case I Start Up and Steady State Responses of VSC- HVDC System Fig. 3-5 shows the start up and steady state responses of the VSC-HVDC system with reference commands u 2 p.u., dcref Qref 2.p.u. for VSC 2 and reference commands P p.u., Q p.u. for VSC. Note that the DC ref ref capacitors have been charged to 2U s ( U s is the RMS value of the AC network line to line voltages) through the diode in the VSC before the start up of the VSCs. In order to prevent VSC-HVDC from overvoltage and over current during the start up, a ramp input P ref is given instead of step. VSC station 2 in VQ control mode will start at t= and VSC station will start until the DC bus voltage reaches the 9 % of the DC base value. From simulation results in Fig 3-5 it can be seen that the VSC-HVDC system start softly and the output of the VSC station exactly reach the set reference values in the steady state. Fig. 5 DC Voltage steady state and start-up response Case II Active and Reactive Power Step Responses Fig. 6-8 shows the active and reactive power step responses. At the beginning active power is transmitted from VSC to VSC 2. The reference active power P ref is reduced from.5 to -.2 at the time t=.5s, and it takes about 3 ms for the measured active power P meas at VSC changes to -.2. Correspondingly, the measured active power P meas2 at VSC 2 changes around from -.4 p.u. to.2 p.u, at the same time active power reverses with the DC current direction change. There is the fluctuation in the reactive power Q and Q2 of the VSC and VSC 2 at the time of step change. However they regain their steady state very quickly. Obviously, the reactive power flow can be controlled at the each AC terminal and the reactive power and the active power control is independent. Notice that considering the loss in the transmission lines, the sending end active power equals the receiving end active power plus losses in the transmission lines. 27, IRJET Impact Factor value: 5.8 ISO 9:28 Certified Journal Page 7

AC Voltage/Uabc (pu) DC Voltage/Ud (pu) Reactive Power (pu) Active Power (pu) International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-56 Volume: 4 Issue: 9 Sep -27 www.irjet.net p-issn: 2395-72.6.4.2 -.2 -.4 -.6 P P2 -.8. Fig. 6 Active power response as step changes Q Q2 Fig. Reactive power response while voltage sag on AC bus is applied. -. -.2 -.3 -.4 Fig.7 Reactive power response as step changes.4.2.8 Ud Ud2 Fig. DC Voltage response while voltage sag on AC bus is applied.6.4.2.5.5 -. pu voltage sag Fig.8 DC Voltage response as step changes Case III A Three Phase Voltage Sag at Station Fig.9-3 shows a three phase voltage sag is applied at station AC bus. The AC voltage sag with -. p.u voltage amplitude is applied at the time between.3s and.65s. The result shows that the active and reactive power deviation which is shown in circle, from the first disturbance is less than. p.u and.2 p.u respectively. It takes about ms to recover the steady state before the next perturbation initiation. -.5 - Phase a phase b phase c -.5 Fig.2 AC Voltage at station when voltage sag is applied. Fig.3 AC Current at station when voltage sag is applied. Case IV A Three Phase to Ground Fault at Station 2 Fig.9 Active power response while voltage sag on AC bus is applied. Fig. 4-8 shows a three phase to ground fault is applied at station 2 AC bus. The fault is applied at t=.5 s during 3 ms. Note that the during three phase fault, the transmitted power is almost zero. The system recovers well after the fault within.3 s. 27, IRJET Impact Factor value: 5.8 ISO 9:28 Certified Journal Page 7

AC Voltage/Uabc2 (pu) DC Voltage/Ud (pu) Reactive Power (pu) Active Power (pu) AC Current/Iabc2 (pu) International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-56 Volume: 4 Issue: 9 Sep -27 www.irjet.net p-issn: 2395-72.5 P P2 4 3 phase a phase b phase c.5 -.5 - -.5 Fig.4 Active power response when three phase to ground fault applied at station 2.5 -.5 - -.5 Fig.5 Reactive power response when three phase to ground fault applied at station 2.4.2.8.6.4.2 Fig.6 DC Voltage response when three phase to ground fault applied at station 2.5.5 -.5 - Three phase to ground fault -.5 Q Q2 phase a phase b phase c Fig.7 AC Voltage when three phase to ground fault applied at station 2. Ud Ud2 2 - -2-3 Fig.8 AC Current when three phase to ground fault applied at station 2. 5. CONCLUSIONS () A steady state analysis of a VSC based HVDC system is derived, starting from the basic mathematical equations. The model consists of AC side equations, DC side equations and converter (AC-DC coupling) equations. Also the control systems are included in the model. (2) The DC side equations have been generalized to multiterminal HVDC systems for the topology, proposing a meshed DC system with every terminal consisting of one converter and with the possibility of connections within the DC system. (3) Every terminal of the two-terminal HVDC system is defined on the type of station. The control parameters are tuned according to some predefined properties of the dynamic responses. Therefore, a linear control model is derived. (4) The simulation results illustrate the fast system response and the influence of a change in the control references on different system variables. (5) This thesis deals with the application of VSC-HVDC transmission for the improvement of power system stability. Simulation result reveals that faster, independent control of real and reactive power can greatly improve the stability of power system. (6) Some application of VSC-HVDC like interconnection of asynchronous grids and benefits like black start capability, frequency support, and voltage regulation can be achieved. Voltage stability was improved and protect the system from voltage collapsing due to lake of reactive power. REFERENCES [] Omar A. Urquidez, Le Xie, Singular Value Sensitivity Based Optimal Control of Embedded VSC HVDC for Steady State Voltage Stability Enhancement, IEEE Transactions on Power System,Vol. 3,No., January 26. [2] Krishna Chaitanya Diggavi, K. Janardan Rao, Performance Analysis of VSC MMC Based Hybrid HVDC Transmission System IEEE International Conference on Advances in Electrical, Electronics, 27, IRJET Impact Factor value: 5.8 ISO 9:28 Certified Journal Page 72

International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-56 Volume: 4 Issue: 9 Sep -27 www.irjet.net p-issn: 2395-72 Information, Communication and Bio- Informatics (AEEICB6), 26. [3] G.P. Adam, O. Anaya Lara and G. Burt, Steady State and Transient Performance of DC Transmission Systems Based on HVDC Technology Stratchlyde University, Institute of Energy and Environment, Glasgow, U.K. [4] K. Karthi,R. Radhakrishnan,JM. Bhaskaran,Louis Sam Titus, Performance analysis on Various Controllers of VSC HVDC Transmission Systems, IEEE International Conference on Computational Intelligence and Computing Research,26 [5] Jiuping Pan, Reynaldo Nuqui, Kailash Srivastava, Tomas Jonsson, Per Holmberg, Ying-Jiang Hafner, AC Grid with Embedded VSC HVDC for Secure and Efficient Power Delivery, IEEE Energy 23 Atlanta, GA USA, 7 8 November, 28. [6] Guangkai Li, Member IEEE, Stability Analysis of the Initial Period of Power System Restoration Using the Path Including VSC HVDC, Dept. of Direct Current Transmission CSG Technology Research Center Guangzhou, China. [7] H. F. Latorre and M. Gandhari,Member IEEE, Improvement of Voltage Stability by Using VSC HVDC, IEEE T & D ASIA - SIEF 29, SEOUL, KOREA, OCTOBER 26 3, 29. [8] Chengyong Zhao and Chunyi Guo, Member IEEE, Complete Independent Control Stratgy of Active and Reactive power for VSC Based HVDC System, National Science Foundation of China and North China Electric Power University, IEEE Conference, 29. [9] Djehaf M, Zidi S A, Khatir M, Hadjeri S, Djilani Kobibi Y, Steady State and Dynamic Modeling of Asynchronous Back-To Back High Voltage Direct Current Link With Voltage Source Converters". Conference IEEE, 23 27, IRJET Impact Factor value: 5.8 ISO 9:28 Certified Journal Page 73