Electric Strikes Instructions

Similar documents
OVERVIEW. Mounting Post (2 places) Cylinder Cam. Handing Pin

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

Installing Your Electronic Deadbolt

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

SD-996C-NUVQ Electric Door Strike with Vertical Adjustment

Installation Instructions

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

Installation Instructions

MORTISE LOCK INSTALLATION INSTRUCTIONS

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

CRCODE-202. Mechanical Lock. Instruction and Programming Manual. Before Installing:

SERIES 6000 ELECTRIC STRIKES

10027 S. 51st Street, Ste 102 Phoenix, Arizona (800) Fax:(800)

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions

Entry Mortise Lock Set Lever to Lever

HIT-30 ALUMINUM DOOR SERIES OWNERS MANUAL

Installation Instructions

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

Installation Instructions ED4400, ED4400M & ED4400MA Series Surface Vertical Rod Exit Devices

Shim (2) Supplied. Strike Plate. (3) x 5/8" PFHMS or 10 x 1" PFHWS. Top Latch. (3) x 1/4" PRHMS. Latch Cover. (2) 8 x 3/8" PFH AB SMS

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

7130(F) Series Mortise Exit Devices Installation Instructions

Travel Trailer Latch With Dead Bolt Trailer Latch With Dead Bolt. U.S. Patent No. 5,927,773

Table of Contents IMPORTANT

1530(F) Mortise Exit Devices Installation Instructions

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

SD-996C-NUQ. Universal Door Strike. Manual

Installation Instructions

Passage Mortise Lock Set Lever to Lever

1790 Touchbar. Installation Instructions. Rim Panic Device ININST Index:

Atrium Patio Door Field Service Manual

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

INSTALLATION INSTRUCTIONS CRL JACKSON

INSTALLATION INSTRUCTIONS REPLACING EXISTING DEADBOLT ASSEMBLY

Assembly Instructions 10 X 10 Aluminum Frame Building

For New or Retrofit Construction Retrofits Existing ANSI 4-7/8 Strike Prep No Centerline Relocation

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

Installation Instructions for 45H & 47H Mortise Locks

Quill Stop V2 Installation Guide 11/16/2014

CM5500 COMPUTER MANAGED MORTISE LOCK INSTALLATION MANUAL

RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 3 BULL BAR 99-04, 04 "HERITAGE" F-150/250LD 2WD, 97-04, 04 "HERITAGE" 4WD WD EXPEDITION/ WD EXPEDITION PART

Adams Rite. Standard & Heavy Duty Deadlatches Series Heavy Duty Deadlatch

INSTALLATION INSTRUCTIONS RH 412 STEEL DOORS

6 BAY AV CREDENZA WITH DUAL DISPLAY MOUNT

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

CL4500 Installation Instructions

ED1100 /1100F SERIES RIM EXIT DEVICE INSTALLATION INSTRUCTIONS

CONCEALED VERTICAL ROD PANIC EXIT DEVICE

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

1006CLB 12VDC or 24VDC Fail secure 12V-45mA, 24V-25mA

Installation Instructions RF5910

Fig. 2 DORMA-Glas Stand/Issue 02/03 Seite/Page 1/7

Chapter 9. Windows and Exterior Doors

Electric Strike Complete with LB option includes faceplates that accommodate J, K, KM or KD options

Table of Contents IMPORTANT

Installation Instructions for 45HW & 47HW Electrified Mortise Locks

The Nantucket Legacy Arbor

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

98/ Customer Service # Dogging Key (use to lock down pushbar)

Installation Instructions RF8010/RF8310 RF8010/RF8310: EXTERNAL ANTENNA

Endcap P/N: X. Endcap Bracket P/N: Endcap Bracket with 9V battery holder P/N: Fillerplate SubAssembly

S6 User s Manual USER S MANUAL ver. 1.0

INSTALLATION INSTRUCTIONS FOR ARCHITECTURAL VALUE SERIES ELECTRIC DOGGING / ELECTRIC LATCH RETRACTION AND "H" MODELS (HURRICANE) Endcap P/N:

INSTALLATION MANUAL FORTRESS SERIES

Tools Required. * When installing on a fire door, please see instructions below. *

CM5500 COMPUTER MANAGED MORTISE LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

120x165mm. 85x165mm TEMPLATE. ELECTRONIC DEADBOLT model no.: & & Toll-free Number:

Important: Read this first!

ED5200(A) Series Rim Exit Devices

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

8500 Series. The fire-rated, concealed electric strike solution for mortise locksets. Available At. Click Here FOLGER ADAM HES INTEGRATED PRODUCTS

Installation Instructions for Deadbolt Models OP 8102LT

SSRLS-3 / SSRLU-3 Installation Instructions

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

Gen 2.0 Side Patio Rail Kit OEM INSTALLATION MANUAL

33/3550AWDC. Fire-Rated Devices include these. additional. components. 1-Point Latch (LBL) Metal Edge Wrap required for 60 and 90-minute applications

Sentinel Series Cigar Humidor End Tables

Installation Instructions For The 8850FL Series Mortise eboss

Chapter 9. Windows and Exterior Doors

3 BAY AV CREDENZA WITH SINGLE DISPLAY MOUNT

Installation Instructions II-2/4/5K-0608

INSTALLATION INSTRUCTIONS

SGD 2000/2500 Assembly

Shepherd 210A Fingerprint Door Lock Installation Manual V1.1

Studio Face Xtreme 6020 Installation Instructions (Nickel , Black )

7878 K940. Checkpoint Antenna. Kit Instructions. Issue B

John Deere ME5 Row Unit Kit Installation Manual Kit Number

Replacing the Reciprocator on an SWF Multi-head.

Rim-Lock Door Set Installation Instructions

WARNING: Prior to installation, turn the power off to the vending machine and unplug it from its power source. Also, make sure to level the machine.

Installation Instructions ENGLISH

LF Series Assembly Instructions

HES Series Electric Strikes & Optional faceplates 1006 Grade 1 electric StrikeS series optional faceplates AD: E Option

INSTRUCTIONS FOR 1431 Door Closer with Hold Open Arms 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

Sliding Glass Door Assembly and Installation Guide

INSTRUCTIONS FOR HIT-41 SERIES ELECTRIC STRIKE TEMPLATES WHEN USING POWER TOOLS ALWAYS WEAR EYE AND EAR PROTECTION!!

Transcription:

Installation S84/86 Series lectric Strikes Instructions The S84/86 electric strikes include two profiles: The S84 (Low Profile) version features a 1-1/16 body, accepts 1/2 or 5/8 latch projection, and is designed for narrow stile (i.e., aluminum) frames. The S86 (Standard Profile) version features a 1-3/16 body that accepts 3/4 latch projection. NOT: Universal packaging (faceplate U ) includes faceplate sizes 86S4, 86S4S, and 86S7. 1. etermine the vertical centerline of the door lock face and the horizontal centerline of the latch. IPOTNT: When determining the horizontal centerline observe the following: O OTIS LOS: lign the angled ramps of the lip bracket with the deadlock trigger of the mortise latch. O YLINIL LOS: lign the center of the latch with the center of the strike opening.** 2. Transfer both the horizontal and vertical centerlines to the doorframe.** 3. Prepare the doorframe for cutting as shown in the appropriate drawing. luminum rames 1-3/16 odular S86 SV or S86 SV L or S86 U assembled with 86S4 faceplate 4. If required, install the no weld mounting tabs per page 4. 5. ttach the strike faceplate to the lip bracket with the selftapping screws provided. (It may be desirable to leave these screws slightly loose to facilitate insertion into the doorframe. 6. onnect the incoming wiring from the power supply (see wiring instructions). 7. Install the door strike in the doorframe using the screws provided. luminum rames 1-1/16 odular S84 SV or S84 SV L or S84 U assembled with 86S4 faceplate SUNT TIONL IL TI SUNT TIONL IL TI 1-1/4 1.250 31.75 4-7/8 4.875 123.83 3-3/8 3.375 85.73 1-3/16 1.188 30.16 3/8.375 9.53 1-11/16 1.688 42.86 Vertical enterline /L /L /L oor oor oor 5/32 0.156 3.97 4-1/8 4.125 104.78 12-24 1-1/4 1.250 31.75 4-7/8 4.875 123.83 3-3/8 3.375 85.73 1-3/32 1.094 27.78 3/8.375 9.53 1-11/16 1.688 42.86 Vertical enterline /L /L /L oor oor oor 5/32 0.156 3.97 4-1/8 4.125 104.78 12-24 NOT: Specifications subject to change without notice. * imension is measured from face of mounting tab to face of frame. ** imension on the drawing is determined by the vertical centerline of the door. If the latch incorporates a deadlocking pin additional steps will be necessary to ensure proper operation of the deadlocking pin. easure the thickness of the deadlocking pin and add this thickness to imension to relocate the vertical centerline an appropriate distance on the frame. ISS84/86 08281220 2015 O US: O IV, W, STOWN, P 17567 PHON: (800) 523-8483 (717) 336-3881 : (717) 336-2106 mail: archdw@dorma-usa.com Website: dorma-usa.com PN14085 09/15T

S84/86 Series Installation Instructions (ontinued) luminum & Wood rames, 1-3/16 odular S86 SV or S86 SV L assembled with 86S5 faceplate luminum & Wood rames, 1-1/16 odular S84 SV or S84 SV L assembled with 86S5 faceplate SUNT TIONL IL TI 1-1/8 1.125 28.58 5-7/8 5.875 149.23 3-3/8 3.375 85.73 1-3/16 1.188 30.16 1/4 0.250 6.35 1-11/16 1.688 42.86 Vertical Vertical enterline Vertical oor oor oor 5/32.156 3.97 5-3/8 5.375 136.53 12-24 SUNT TIONL IL TI 1-1/8 1.125 28.58 5-7/8 5.875 149.23 3-3/8 3.375 85.73 1-3/32 1.094 27.78 1/4 0.250 6.35 1-11/16 1.688 42.86 Vertical enterline /L /L /L oor oor oor 5/32.156 3.97 5-3/8 5.375 136.53 12-24 luminum & Wood rames, 1-3/16 odular S86 SV or S86 SV L assembled with 86S6 faceplate luminum & Wood rames, 1-1/16 odular S84 SV or S84 SV L assembled with 86S6 faceplate SUNT TIONL IL TI SUNT TIONL IL TI 1-1/4 1.250 31.75 6-7/8 6.875 174.63 3-3/8 3.375 85.73 1-3/16 1.188 30.16 3/8 0.375 9.53 1-11/16 1.688 42.86 Vertical enterline /L /L /L oor oor oor 5/32.156 3.97 6-1/8 6.125 155.58 12-24 1-1/4 1.250 31.75 6-7/8 6.875 174.63 3-3/8 3.375 85.73 1-3/32 1.094 27.78 3/8 0.375 9.53 1-11/16 1.688 42.86 Vertical enterline /L /L /L oor oor oor 5/32.156 3.97 6-1/8 6.125 155.58 12-24 NOT: Specifications subject to change without notice. * imension is measured from face of mounting tab to face of frame. ** imension on the drawing is determined by the vertical centerline of the door. If the latch incorporates a deadlocking pin additional steps will be necessary to ensure proper operation of the deadlocking pin. easure the thickness of the deadlocking pin and add this thickness to imension to relocate the vertical centerline an appropriate distance on the frame. or wood frame door installations, substitute #12 wood screws for dimension. 2

S84/86 Series Installation Instructions (ontinued) luminum & Wood rames, 1-3/16 odular S86 SV or S86 SV L or S86 U assembled with 86S7 faceplate luminum & Wood rames, 1-1/16 odular S84 SV or S84 SV L or S84 U assembled with 86S7 faceplate SUNT TIONL IL TI 1-7/16 1.438 36.51 7-15/16 7.938 201.61 3-3/8 3.375 85.73 1-3/16 1.188 30.16 1/4 0.250 6.35 1-11/16 1.688 42.86 Vertical enterline /L /L /L oor oor oor 5/32.156 3.97 7-7/16 7.438 188.91 12-24 SUNT TIONL IL TI 1-7/16 1.438 36.51 7-15/16 7.938 201.61 3-3/8 3.375 85.73 1-3/32 1.094 27.78 1/4 0.250 6.35 1-11/16 1.688 42.86 Vertical enterline /L /L /L oor oor oor 5/32.156 3.97 7-7/16 7.438 188.91 12-24 Hollow etal rames, 1-3/16 odular S86 SV or S86 SV L or S86 U assembled with 86S4S faceplate Hollow etal rames, 1-1/16 odular S84 SV or S84 SV L or S84 U assembled with 86S4S faceplate SUNT TIONL IL TI SUNT TIONL IL TI 1-1/4 1.250 31.75 4-7/8 4.875 123.83 3-3/8 3.375 85.73 1-3/16 1.188 30.16 3/8.375 9.53 1-11/16 1.688 42.86 Vertical enterline /L /L /L oor oor oor 4-1/8 4.125 104.78 12-24 1-1/4 1.250 31.75 4-7/8 4.875 123.83 3-3/8 3.375 85.73 1-3/32 1.094 27.78 3/8.375 9.53 1-11/16 1.688 42.86 Vertical enterline /L /L /L oor oor oor 4-1/8 4.125 104.78 12-24 NOT: Specifications subject to change without notice. * imension is measured from face of mounting tab to face of frame. ** imension on the drawing is determined by the vertical centerline of the door. If the latch incorporates a deadlocking pin additional steps will be necessary to ensure proper operation of the deadlocking pin. easure the thickness of the deadlocking pin and add this thickness to imension to relocate the vertical centerline an appropriate distance on the frame. or wood frame door installations, substitute #12 wood screws for dimension. 3

S84/86 Series Installation Instructions (ontinued) ounting Tab it Instructions Self-dhesive ounting Shim (8 incl.) 12-24 achine Screws (2 per tab) ounting Tab (2 incl.) ounting tab kit is for use with aluminum and steel frames that do not have factory installed mounting tabs for electric strike installation. 1. Prepare the frame as shown in the approximate drawing. asten the mounting tab to the faceplate of the strike, selecting the appropriate shims for the installation. 2. Using the assembled strike and tabs as a template, place against the frame and mark the mounting hole locations. emove and drill a 3/16 hole in frame for each mounting tab and countersink the frame. 3. emove the tabs from the faceplate and install in the frame using the 12-24 x 3/8 machine screws supplied. Tabs are zinc plated and drilled and tapped for this purpose. 4. ake final electrical connections per wiring instructions and mount strike to the tabs with the 12-24 x 3/8 machine screws. rame Trim Plate Instructions 1. Position the Trim Plate on the frame cut-out to verify fit and coverage. 2. djust cut-out if required. 3. end the four tabs to hold the Trim Plate onto the frame. 4. or a tighter fit, pre-bend the two long flange tabs before sliding onto the frame where space allows. 5. Secure the strike to the frame as per strike installation instructions. 4

S84/86 Series Installation Instructions (ontinued) ail Unlocked otate the adjustment screw so the dimple is fully rotated to opposite the faceplate side of the strike (fully counter clockwise). Your strike is now fail unlocked and requires power to lock. See ig. 1. ig. 1 ail Unlocked = screw fully counter clockwise ail Locked otate the adjustment screw so the dimple is fully rotated to the faceplate side of the strike (fully clockwise). Your strike is now fail locked and requires power to unlock the door. See ig 2. Wiring Instructions NOT: Overheated or urnt oils caused by incorrect input voltage / wire harness combinations are not covered under warranty. Use 12V wire harness for 12V or 12-24V input power. Use 24V wire harness for 24V input power only ttach the red wire to (+) positive of the power supply. ttach the black wire to the ( ) negative of the power supply (see ig. 4). If using power, polarity is not observed. To meet H 156.31 install the OV provided across the positive and negative wires or terminals of the harness. The OV is not polarity sensitive. NOT: If a suppression diode is required for access control, observe proper polarity. 24V Terminal 12V 12-24V Terminal ed lack + ig. 2 ail Locked = screw fully clockwise Lip racket djustment If your door or latch is out of adjustment, the insert can be adjusted forward or back as required for proper alignment to the latch. See ig. 3 1. emove the strike from the frame. 2. emove the faceplate from the strike. 3. 2 screws secure the lip bracket to the main insert. 4. Loosen these screws approximately 1-1/2 to 2 full turns to allow the insert to move forward or backward as required. 5. Once the adjustment is made tighten all screws and reinstall the strike in the frame. ed lack + N NO lack lue Latch onitor NO N Latch onitor Wires (L option) = oon () = Normally lose (N) Orange = Normally Open (NO) eeper onitor ig. 4 Wiring the S84/86 Series electric strike Optional L aceplate emoved Lip racket Screw djustment irection eeper onitor Wires (L option) lack = oon () Yellow = Normally losed (N) reen = Normally Open (NO) eeper When using L option: Strike Insert ig. 3 Lip bracket adjustment Lip racket If the lockset on the door has a 1/2 or 5/8 latch projection, The S84 model is appropriate. If the lockset on the door has a 3/4 latch projection, you must use the S86 model. NOT: ontacts are indicated with the keeper in a closed and locked condition, with no latch present. 5

S84/86 Series Troubleshooting 1. Problem Strike will not lock or unlock properly Possible auses No power to the insert Solution Using a multimeter, confirm that you have the correct output voltage at the power supply. Using a multimeter, confirm that you have the correct input voltage at the strike. onfirm that all connections are tight and secure. Incorrect voltage used onfirm that the insert and power supply are the proper voltage. Strike is binding onfirm that the strike keeper functions when the door is open. If the strike operates correctly, adjust door or strike to eliminate any backpressure. onfirm that the strike cavity depth is compatible with the lock set. 2. Strike releases but won t buzz Improper power supply eplace the power supply with a correct voltage power supply, and the 12V connector. If this cannot be done, a piezo buzzer may be installed. 3. Strike makes a buzzing sound Improper power supply eplace the power supply with a correct voltage power supply. Improper application strike connected to an power supply will buzz unless a rectifier is installed. 4. Insert has a burnt smell Improper voltage onfirm that you have the correct output voltage at the power supply. Improper installation onfirm that the correct connector was used when installing the strike 12V for 12V & 12-24V, 24V for 24V only. onfirm that all connections are tight and secure. 5. ortise lock not dead latching Improper Installation oor has sagged heck alignment of dead latch and lip bracket ramp. djust door alignment. 6. ylindrical deadlatching not working Improper Installation / oor has warped djust the strike horizontal adjustment. (See Installation Instructions). 7. oor won t latch oor has warped or sagged creating excessive back pressure e-align door in frame or replace. 8. onitor switch is not functioning Short in wiring onfirm that all connections are tight and secure. Using a multimeter confirm continuity of the N/O & N/ sides of the switch. Latch or keeper are not functioning properly onfirm that the keeper is closing properly and that the lever in the strike cavity is operating freely. 6 2015 O US: O IV, W, STOWN, P 17567 PHON: (800) 523-8483 (717) 336-3881 : (717) 336-2106 mail: archdw@dorma-usa.com Website: dorma-usa.com