ZipTENSIONER Wind Turbine

Similar documents
Zip Technology. ZipNut and ZipCONNECTOR

Joint Preparation prior to Tensioning: General:

ARCONIC FASTENING SYSTEMS AND RINGS WIND POWER APPLICATIONS

Bolt Tightening Solutions Torque and Tension, we ve got got it covered.

BOLTIGHT HYDRAULIC BOLT TENSIONING TIGHTEN BOLTS SIMULTANEOUSLY TO ENSURE EVEN PRELOAD

HP-10 Hand Puller Operator Manual

OTECO INC. MODEL ,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL

MECH-100: Fundamentals of Precision Maintenance

BEL Puller For 8" Reverse Osmosis pressure vessels heads installation

Welding vs. Fastening Vibration-Resistant, Direct-Tension Huckbolts Change the Equation

Fluid Sealing Association

EURO DELUXE INSTALLATION INSTRUCTIONS

INSTRUCTIONS 360 CHAINROLL

Bolt Tensioner. Axial Bolt Tensioning using High-Pressure Hydraulic. SSV and HM Axial bolt tensioning without torquing!

INSTRUCTION MANUAL IM 382 For Gas Turbine Tensioned Studs and Nuts CUSTOMER'S INFORMATION BOX CONTENTS ARE INDEPENDENT OF RIVERHAWK DOCUMENT CONTROL

CAM SYSTEM. Eccentric self-locking clamping devices. Set. CAM SYSTEM t. CAM SYSTEM t. Set. CAM SYSTEM s pag CAM SYSTEM s pag.

Machine vices RB and RH

LCD LIFT Flat Panel Display System Installation Manual. Table of Contents

PORTABLE PULL TESTER

Installation instructions for FC9 & FC18 Forward Controls for Yamaha V-Max

Instructions for Converting the LV/MB Joystick from A to A1

Monster Tower Phone: U.S. Hwy 411 S. HS1. Installation Instructions and Owner s Manual CAUTION

Referencing 0,0 position

DB Four Needle Double Chain stitcher. Specifications. 4 needles. *A needle gauge for 60 is U1401 only. DB /

F. Rotor Head Maintenance

Free Standing Pedestal Mounting Installation Manual

PM4S3 Monitor Kiosk. features and benefits: dimensions: additional information:

First published : May 1997 Fourth edition : January No

adaptivemechanical adaptive

Cyclic tests of engineered shear walls with different bottom plate and anchor bolt washer sizes (Phase II)

Decide what reach is required. This must be at least equal to or larger than the depth of the part which needs removal. Safe Working Load (tonnes)

Model No: TC10. Parts Information: Tyre Changer - Automatic

Pull-down clamps. No Low height clamping jaws, model Bulle

HUCK BOBTAIL FASTENING SYSTEM NEW SOLUTION FOR HIGH-STRENGTH LOCKBOLTS

Turret covers. Rear turret cover

Section 1: Parts List. Section 2: Additional Considerations

Specialist Tool Solutions PULLERS, SEPARATORS & TORQUE

63824 Ford Combination Vacuum Pump/Alternator Mount

Service Parts List AA4V90

MINI-LATHE QUICK CHANGE TOOL POST

BBF Series Blower Base Frame Assembly Instructions Rev.: BFA-9105

FRAME. Pull Type Rigid Frame, Lift Rotate INNER HITCH

LOCTITE WEBINAR SERIES Threadlocking & the Torque-Tension Relationship

JD 2. Model 6 Bender Setup and Operation Manual


INSTALLATION GUIDE 2009-CURRENT HUMMER H3T PRODUCT CODE:

Fig Remove chain cover plate bolts. Fig Remove hammer member. Fig Loosen set screws at base of 12-tooth sprocket.

ADJUSTING INSTRUCTIONS

ClampStar Safe-T-Link Tether Installation Instructions for Deadends

Formulate Designer Series 10 Backwall - Kit 11

Formulate Designer Series 20 Backwall - Kit 06

Pressure Vessel Assembly Instructions

Formulate Designer Series 10 Backwall - Kit 10

600mm COMPOUND MITRE SAW ASSEMBLY INSTRUCTIONS. MODEL NO: MBS600D Part No: GC05/12

MODEL SK61732 COMPRESSOR SERVICE KIT

Sapper XYZ Monitor Arm Installation Instructions




Formulate Designer Series 20 Backwall - Kit 07

Overview. Linear Motion and Assembly Technologies /11 Aluminum Framing. Bosch Rexroth Corp. Section 15: Tools

E4-WM5-Y542A00 MOUNTING INSTRUCTION

Universal Barricade Assembly Instructions

PRODUCTS AND SERVICES

Removing the Z-Axis lead screw

18000 HDL FOUR POST LIFT LB CAPACITY INSTALLATION AND OWNER'S MANUAL

By C.W. Woodson From the pages of Model Craftsman magazine June, 1937

Hydrajaws Safety Lifeline Tester

Flexshaft Assembly. Flexshaft Support Tube. Clear Front Cover FIGURE 1: EXTERIOR VIEW OF THE FLEXSHAFT AND HEAD COVERS

Formulate Designer Series 10 Backwall - Kit 09

Drake Off Road Hood Hold Downs Installation Guide

FabLite Designer Series 10' Kit 06 - FL10-DS06

RTI TECHNOLOGIES, INC.

USER MANUAL & PARTS LIST MODEL 136A S/N:

GH BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODEL F10207 DOUBLE ACTING HYDRAULIC ACTUATOR

Installation Instructions

Kit 102 Series Installation Instructions for Wood or Metal Posts on Level Runs

What is the Hydraulic 1500 Series?

Procedure for Testing Direct Tension Indicators (DTI) Assemblies

Unirac Installation Manual

6o ft (18.3 m) Southwest Windpower, Inc West Route 66 Flagstaff, Arizona USA Phone: Fax:

WILDING WALLBEDS INSTALLATION INSTRUCTION Side Mount

10 Ton Hydraulic Puller Set

ENGINE CRATE FABRICATION

Motorized Tower Raising System Manual

Form No Assembly & Operating Instructions for: SAFETY PRECAUTIONS

Tech Support: Option 2

HARDINGE Installation booklet For: Dead-Length Collet Adaptation Chucks Stationary Collet

DynaPower Generation II


Installation Instructions for Solar Snow Pad (SSP-T-3)

Technical Information

HILMA Quick Tool Change for Forging Applications

INSTALLATION INSTRUCTION RRU DOUBLE LIGHT POLE MOUNT

SWAG AIR-HYDRO RAM MOUNT ASSEMBLY INSTRUCTIONS

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) NUT SPLITTER. Max.

Inventory (Figure 2)

One Piece LSD/Vector Pads from TIE DOWN ENGINEERING Easier installation with 70% fewer parts Lower cost with competitive pricing

TWIN ROD CYLINDERS 6 CONTENTS

Transcription:

Wind Turbine Foundation Stud Tensioners Quick, safe and accurate tool Simultaneous loading of multiple threaded studs and bolts Available with ZipNut Technology Long working stroke (.625 ) standard Captivenutrotator, two hyrdraulic ports Over-stroke indicator Models to provide maximum tension from 86,800 pounds at 10,000 to 134,573 pounds at 9,600 hydraulic pressure Leading provider of bolt loading & removal solutions Products and Prices are subject to updates and changes. Please contact us for current quote. 2013

F61-10-32MM-10K Stud Tensioner The F61-10-32MM-10K Stud Tensioner is designed to tension 34MM Williams #10 Grade 75 Bar foundation bolts on wind turbine towers. The piston area of the tensioner is 8.68 square inches. This area provides a maximum tension of 86,800 pounds at 10,000 hydraulic pressure. The tensioner has a 1 inch stroke, therefore, full elongation of the foundation bolts is accomplished with just one pull. The F61-10-32MM-10K utilizes a puller bar, which is threaded down on the foundation bolt. This allows the F61-10-32MM-10K to be used on foundation bolts with at least 7-1/2 inches protruding above the foundation. 1,000 8,680 2,000 17,360 3,000 26,040 4,000 34,720 5,000 43,400 6,000 52,080 7,000 60,760 8,000 69,440 9,000 78,120 10,000 86,800

F61-11-35MM-10K Stud Tensioner The F61-11-35MM-10K Stud Tensioner is designed to tension 35MM Williams #11 Grade 75 Bar foundation bolts on wind turbine towers. The piston area of the tensioner is 9.988 square inches. This area provides a maximum tension of 99,880 pounds at 10,000 hydraulic pressure. The tensioner has a one inch stroke, therefore, full elongation of the foundation bolts is accomplished with just two pulls. The tensioner is double acting, so the piston is returned hydraulically. The F61-11-35MM-10K utilizes a puller bar, which is threaded down on the foundation bolt. This allows the F61-11-35MM-10K to be used on foundation bolts with at least 9 inches protruding above the foundation. 1,000 9,988 2,000 19,976 3,000 29,964 4,000 39,952 5,000 49,940 6,000 59,928 7,000 69,916 8,000 79,904 9,000 89,892 10,000 99,880

F71-11-36MM-10K Stud Tensioner The F71-11-36MM-10K Stud Tensioner is designed to tension 36MM Williams #11 Grade 150 Bar foundation bolts on wind turbine towers. The piston area of the tensioner is 14.018 square inches. This area provides a maximum tension of 134,573 pounds at 9,600 hydraulic pressure. The tensioner has a.5 inch stroke, therefore, full elongation of the foundation bolts is accomplished with just two pulls. The F71-11-36MM-10K utilizes a puller bar, which is threaded down on the foundation bolt. This allows the F71-11-36MM-10K to be used on foundation bolts with a minimum of 9 inches protruding above the foundation. 1,000 14,018 2,000 28,036 3,000 42,054 4,000 56,072 5,000 70,090 6,000 84,108 7,000 98,126 8,000 112,144 9,000 126,162 10,000 134,573

DZF61-10-32MM-10K Double Zip Stud Tensioner The Model DZF61-10-32MM-10K Stud Tensioner is designed to tension foundation bolts on wind turbine towers. The Double-Zip Nut mechanism allows the tensioner to slide down over the foundation bolts without rotating a retaining nut. When the tensioner piston is extended, the Double-ZipNut mechanism automatically engages the foundation bolt and pulls it into tension. The piston area of the tensioner is 8.68 square inches. This area provides a maximum tension of 86,800 pounds at 10,000 hydraulic pressure. The tensioner has a one inch stroke, therefore, full elongation of the foundation bolts is accomplished with just one pull. When the bolt is pulled into tension, the nut rotator is turned with a tommy bar to The tensioner is doubleacting, so the piston is returned hydraulically. The Double- Zip Nut mechanism is automatically released when the piston is returned. The DZF61-10-32MM-10K requires the foundation bolt to extend a minimum of 10-½ above the foundation. 1,000 8,680 2,000 17,360 3,000 26,040 4,000 34,720 5,000 43,400 6,000 52,080 7,000 60,760 8,000 69,440 9,000 78,120 10,000 86,800

DZF61-11-35MM-10K Stud Tensioner The DZF61-11-35MM-10K Stud Tensioner is designed to tension 35MM Williams #11 Grade 75 Bar foundation bolts on wind turbine towers. The piston area of the tensioner is 9.988 square inches. This area provides a maximum tension of 99,880 pounds at 10,000 hydraulic pressure. The tensioner has a one inch stroke, therefore, full elongation of the foundation bolts is accomplished with just two pulls. The tensioner is double acting, so the piston is returned hydraulically. The DZF61-11-35MM-10K utilizes a puller bar, which is threaded down on the foundation bolt. This allows the DZF61-11-35MM-10K to be used on foundation bolts with at least 12-1/2 inches protruding above the foundation. 1,000 9,988 2,000 19,976 3,000 29,964 4,000 39,952 5,000 49,940 6,000 59,928 7,000 69,916 8,000 79,904 9,000 89,892 10,000 99,880

DZF71-11-36MM-10K Stud Tensioner The DZF71-11-36MM-10K Stud Tensioner is designed to tension 36MM Williams #11 Grade 150 Bar foundation bolts on wind turbine towers. The piston area of the tensioner is 14.018 square inches. This area provides a maximum tension of 134,573 pounds at 9,600 hydraulic pressure. The tensioner has a 7/8 inch stroke, therefore, full elongation of the foundation bolts is accomplished with just two pulls. The DZF71-11-36MM-10K utilizes a puller bar, which is threaded down on the foundation bolt. This allows the DZF71-11-36MM-10K to be used on foundation bolts with a minimum of 11 inches protruding above the foundation. 1,000 14,018 2,000 28,036 3,000 42,054 4,000 56,072 5,000 70,090 6,000 84,108 7,000 98,126 8,000 112,144 9,000 126,162 10,000 134,573