DESIGN AND IMPLEMENTATION OF THREE PHASE SHUNT APF CURRENT CONTROLLER WITH ANN TECHNIQUE

Similar documents
Design of Shunt Active Power Filter by using An Advanced Current Control Strategy

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

Sinusoidal Current Control based Shunt Active Power Filter for Current Harmonics Reduction

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

Design and Simulation of Three Phase Shunt Active Power Filter Using SRF Theory

Power Quality Improvement Using Hybrid Power Filter Based On Dual Instantaneous Reactive Power Theory With Hysteresis Current Controller

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

Assessment of Different Compensation Strategies in Hybrid Active Power Filters

Control Of Shunt Active Filter Based On Instantaneous Power Theory

A Review on Simulation and Implementation of Thyristor controlled reactor and Shunt Hybrid Power Filter

Implementation of SRF based Multilevel Shunt Active Filter for Harmonic Control

Literature Review for Shunt Active Power Filters

HARMONIC contamination, due to the increment of nonlinear

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Power Quality improvement of a three phase four wire system using UPQC

Design of SVPWM Based Inverter for Mitigation of Harmonics in Power System

A Simple Control Algorithm for Three-Phase Shunt Active Power Filter for Reactive Power and Current Harmonic Compensation

5DESIGN PARAMETERS OF SHUNT ACTIVE FILTER FOR HARMONICS CURRENT MITIGATION

Harmonics Reduction using 4-Leg Shunt Active Power Filters

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Design of a Hybrid Active Filter for Harmonics Suppression in Industrial Facilities

IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 12 June 2016 ISSN (online): X

A Novel FPGA based PWM Active Power Filter for Harmonics Elimination in Power System

ISSN: Page 20. International Journal of Engineering Trends and Technology- Volume2Issue3-2011

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

Shunt active filter algorithms for a three phase system fed to adjustable speed drive

ANALYSIS OF SYNCHRONOUS-REFERENCE-FRAME-BASED CONTROL METHOD FOR UPQC UNDER UNBALANCED AND DISTORTED LOAD CONDITIONS Salava Nagaraju* 1

HYBRID ACTIVE FILTER WITH VARIABLE CONDUCTANCE FOR HARMONIC RESONANCE SUPPRESSION USING ANN

A THREE PHASE SHUNT ACTIVE POWER FILTER FOR HARMONICS REDUCTION

CHAPTER 4 PV-UPQC BASED HARMONICS REDUCTION IN POWER DISTRIBUTION SYSTEMS

2020 P a g e. Figure.2: Line diagram of series active power filter.

Harmonics Elimination Using Shunt Active Filter

DESIGN AND DEVELOPMENT OF ACTIVE POWER FILTER FOR HARMONIC MINIMIZATION USING SYNCHRONOUS REFERENCE FRAME (SRF)

Three Phase Active Shunt Power Filter with Simple Control in PSIM Simulation

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Improving the Power Quality by Four Leg VSI

Svpwm Technique to Eliminate Harmonics and Power Factor Improvement Using Hybrid Power Filter and By Using Dsp Tms 320lf2407

PI Controller Based Shunt Active Power Filter with Cascaded Multilevel Inverter

HYSTERESIS CONTROL FOR CURRENT HARMONICS SUPPRESSION USING SHUNT ACTIVE FILTER. Rajesh Kr. Ahuja

Real Time Implementation of Shunt Active Power Filter (SAPF) for Harmonic suppression and Power Quality Improvement

ISSN Vol.03,Issue.07, August-2015, Pages:

CHAPTER 3 COMBINED MULTIPULSE MULTILEVEL INVERTER BASED STATCOM

SHUNT ACTIVE POWER FILTER

Synchronous Reference Frame Theory For Nonlinear Loads using Mat-lab Simulink

Key-Words: - NARX Neural Network; Nonlinear Loads; Shunt Active Power Filter; Instantaneous Reactive Power Algorithm

A Static Synchronous Compensator for Reactive Power Compensation under Distorted Mains Voltage Conditions

Indirect Current Control of LCL Based Shunt Active Power Filter

TRANSFORMER LESS H6-BRIDGE CASCADED STATCOM WITH STAR CONFIGURATION FOR REAL AND REACTIVE POWER COMPENSATION

POWER QUALITY IMPROVEMENT BY USING ACTIVE POWER FILTERS

A MATLAB-SIMULINK APPROACH TO SHUNT ACTIVE POWER FILTERS

Power Quality Improvement of Non-Linear Load by Using Instantaneous P-Q Theory

MODELLING & SIMULATION OF ACTIVE SHUNT FILTER FOR COMPENSATION OF SYSTEM HARMONICS

Current Rebuilding Concept Applied to Boost CCM for PF Correction

Lecture Note. DC-AC PWM Inverters. Prepared by Dr. Oday A Ahmed Website:

ISSN Vol.04,Issue.08, July-2016, Pages:

Enhancement of Power Quality using active power filter in a Medium-Voltage Distribution Network switching loads

Simulation of Multi Converter Unified Power Quality Conditioner for Two Feeder Distribution System

SHUNT COMPENSATOR USED FOR POWER QUALITY IMPROVEMENT

shunt (parallel series

Power Quality Improvement by Using Shunt Hybrid Power Filter and Thyristor Controlled Reactor with Fuzzy Logic Controller

Comparison of Reference Current Extraction Methods for Shunt Active Power Filters

Mitigation of Harmonics by Shunt Active Power Filter

INVESTIGATION OF HARMONIC DETECTION TECHNIQUES FOR SHUNT ACTIVE POWER FILTER

Implementation of a low cost series compensator for voltage sags

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Application of Fuzzy Logic Controller in Shunt Active Power Filter

CHAPTER 6 THREE-LEVEL INVERTER WITH LC FILTER

Universal power quality conditioner

Experimental Results of a Single-Phase Shunt Active Filter Prototype with Different Switching Techniques

POWER QUALITY IMPROVEMENT BY USING ACTIVE POWER FILTERS

Fuzzy Logic Control of APF for Harmonic Voltage Suppression in Distribution System

The Simplied Control of Three-Phase Four-Leg Shunt Active Power Filter for Harmonics Mitigation, Load Balancing and Reactive Power Compensation

CURRENT HARMONICS REDUCTION IN 3 PHASES 4 WIRE SYSTEM USING HYBRID FILTERS R.Saravanakumar 1#, S.Amritha 2#

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Kalman Filter Based Unified Power Quality Conditioner for Output Regulation

Hybrid Active Power Filters for Reactive Power Compensation with Adaptive DC-Link Voltage Control

Power Quality Improvement using Shunt Passive Filter

Power Quality Improvement By Using DSTATCOM Controller

Load Compensation at a Reduced DC Link Voltage by Using DSTATCOM with Non-Stiff Source

Three Phase Active Power Filter Based on Current Controlled Voltage Source Inverter

Cascaded Multilevel Inverter based Active Filter for Power Line Conditioners using Instantaneous mitigates

PERFORMANCE EVALUATION OF THREE PHASE SCALAR CONTROLLED PWM RECTIFIER USING DIFFERENT CARRIER AND MODULATING SIGNAL

Modeling & Simulation of Micro Grid Distribution System to reduce Harmonics Using Active Power Filters and PI controllers

Reactive Power Compensation of LC Coupling Hybrid Active Power Filters by DC Link Voltage Controls

Design and Simulation of PFC Circuit for AC/DC Converter Based on PWM Boost Regulator

CHAPTER 7 CONCLUSIONS AND FUTURE SCOPE

Power-Quality Improvement with a Voltage-Controlled DSTATCOM

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Modified Three-Phase Four-Wire UPQC Topology with Reduced DC-Link Voltage Rating

ISSN Vol.04,Issue.07, June-2016, Pages:

Power Quality Improvement using Active shunt Power filter using PI Controller

A SPWM CONTROLLED THREE-PHASE UPS FOR NONLINEAR LOADS

Compensation of Harmonics Power by using Shunt Active Filter

Simulation Results of a Shunt Active Power Filter with Control Based on p-q Theory

Fuzzy Logic Controller Based Three-phase Shunt Active Filter for Line Harmonics Reduction

16th NATIONAL POWER SYSTEMS CONFERENCE, 15th-17th DECEMBER,

Transcription:

DESIGN AND IMPLEMENTATION OF THREE PHASE SHUNT APF CURRENT CONTROLLER WITH ANN TECHNIQUE S. Dhayanandh 1 and S. Manoharan 2 1 Department of Electronics and Communication Engineering, Kathir college of Engineering, Coimbatore, India 2 Department of E and I, Karpagam College of Engineering, Coimbatore, India E-Mail: dhayacbe79@gmail.com ABSTRACT The increasing use of nonlinear loads such as adjustable speed drives, electric arc welders and switching power supplies cause s large amounts of harmonic currents injects in to distribution system. LC passive filters are traditionally utilized to compensate the harmonic currents since they are simple and low cost solution. However, they are often large and heavy. In contrast, shunt active power filter purpose is to generate harmonic currents having the same magnitude and opposite phase with the harmonics produced by the nonlinear load and to ensure the supply currents contains only fundamental component. Adopting the advantage of indirect current control schemes i.e., absence of harmonic detector, this paper proposes an advanced control strategy to enhance the APF performance. In the proposed control scheme the supply currents are directly measured and regulated to be sinusoidal by an effective harmonic compensator, which is developed based on a PI and VPI controllers and implemented in the fundamental reference frame. In place of PI and VPI controller a new controller implemented with ANN technique applied as current controller for three phase Shunt Active Power Filter then THD will be further reduced and dynamic response of the system also reduced. Keywords: active power filter, harmonic detector, current controller, ANN technique. INTRODUCTION Power Quality problem is an occurrence manifested as a nonstandard voltage, current or frequency that results in a failure of end user equipment. To compensate harmonics conventional Passive Filters are used for specific number of harmonics. To compress total harmonic content active power filters are used. For all types of power quality solutions at the distribution system voltage level DFACTS also called as Custom Power Devices are introduced to improve Power Quality. Harmonics are periodic sinusoidal distortions of the supply voltage or load current caused by non-linear loads. Harmonics are measured in integer multiples of the fundamental supply frequency. Using Fourier series analysis the individual frequency components of the Figure-1. Shunt active filter network configuration. distorted waveform can be described in terms of the harmonic order, magnitude and phase of each component. The study of power quality, and ways to control it, is a concern for electric utilities, large industrial companies, businesses, and even home users. The study has intensified as equipment has become increasingly sensitive to even minute changes in the power supply voltage, current, and frequency.due to these problems[6], harmonic restriction standards such as IEEE-519 or IEC 61000-3-2 have been published to demand those harmonic currents injected into utility networks to be below the specified values [9]. In order to improve the power quality of distribution networks as well as to meet these restriction standards, two main solutions have been introduced: LC passive filters and active power filter (APF) [7]. It is the most widely used and dominant form of APFs to compensate the load current harmonics and reactive power as well. It is connected in parallel to the distribution supply at PCC and it injects harmonic current that is equal in magnitude to the load harmonic current but having 180 degree phase shift to cancel out the load current harmonics and the source current becomes sinusoidal. This configuration consists of four distinct categories of circuit, namely inverter configurations, switched-capacitor circuits, lattice structured filter and voltage-regulator-type filters. PROPOSED CONTROL STRATEGY FOR APF In order to simplify the control scheme and to enhance the accuracy of the APF, an advanced control strategy is proposed, as shown in Figure-2. The proposed control scheme is implemented by using only the supply current (i Saand i Sb) without detecting the load current (i S,abc) and filter current(i F,abc). The proposed control scheme can be implemented with only two loops, the outer voltage control and the inner current control. The outer loop aims to keep dc-link voltage of the APF constant through a PI controller, which helps the APF deal with load variations. The output of this control loop is the reference active current in the fundamental reference frame (i * sq). 2049

Figure-2. Typical control scheme of a shunt APF. CONTROL SIGNAL COMPUTATION FOR FOUR SWITCH 3φ- INVERTER The circuit diagram of the four-switch threephase dc/ac converter when fed by a single-phase or a three-phase diode rectifier. The three-phase solution is shown in Figure-4. The B4 inverter employs four switches and four diodes to generate two line-to-line voltages and, where as is generated according to Kirchhoff s voltage law from a split. Meanwhile, the reference reactive current (i* sq) is simply set to be zero, which ensures the reactive power provided by the power supply to be zero. And, the reactive power caused by loads is supplied by the shunt APF [1]. The inner loop is then used to regulate the supply current in the fundamental reference frame (i Sdq) by using the proposed PI-VPI current controller. The output of this loop becomes the control signal (v * Fab) applied to the fourswitch APF which is implemented by the FSTPI. Since the current control is executed without the harmonic detector, the control performance of the APF only relies on the current controller. PLL FOR SUPPLY VOLTAGE Supply voltage is regularly not pure sinusoidal but contains harmonic components, which may affect to the accuracy of the PLL [4]. To overcome this problem, a band pass filter (BPF) tuned at the fundamental frequency of the supply voltage is implemented to reject all of the harmonic components contained in supply voltage, and its output contains only the fundamental component which is used as the input of the PLL block. Even though the BPF used in the PLL can cause a small time delay in tracking the phase angle of the supply voltage, it is negligible because the PLL usually operates at steady-state condition before the APF is active. SUPPLY CURRENT CONTROL LOOP This loop regulates the supply current by means of the proposed current control scheme shown in Fig-3. The reference active current i * Sd is the output of the dc-link voltage control loop, while the reference reactive current i* Sq is simply set to be zero. Consequently, the reactive power caused by loads can be fully compensated by the APF, and also unity power factor condition is achieved at the supply side. Figure-3. Block diagram of the proposed current control scheme. Figure-4. Three-phase rectifier capacitor bank. Due to the circuit configuration, the maximum obtainable peak value of the line-to-line voltage equals In order to get a higher dc-link voltage, an input transformer can be considered as shown in Figure-4. For the analysis, the inverter is considered to be built by ideal switches. The output voltages are defined by the gating signals of the two leg switches and by the two dc link voltages and this way, it is further possible to take into account the influence of the variations of the voltage across the two dc-link capacitors. The expressions of the output voltages and the dc-link currents yield by writing the Kirchhoff equations for the load, and taking into consideration two switching functions for the two inverter legs. DC-LINK VOLTAGE CONTROL LOOP This control loop aims to keep dc-link voltage of the shunt APF constant through a simple PI regulator, whose output is the reference active current in the fundamental reference frame as follows: i * sd=(k pdc+k idc/s)(v * dc-v dc) (1) Where Kpdc and Kidc are the proportional and integrator gains of the PI controller, respectively, and V * dc and Vdc are reference and measured dc-link voltages of the APF, respectively. In fact, since the four-switch APF has only two switching legs, the four-switch APF needs a higher dc-link voltage reference(v * dc). In addition, since the dc-link voltage of the APF contains small ripples at harmonic frequencies due to harmonic currents, a low-pass filter (LPF) is designed to eliminate all ripples in the feedback measurement of the dc-link voltage, which helps in smoothing the reference current i*sd. In the proposed control scheme, the role of the dc-link voltage controller is not only to ensure a proper operation of the APF but also to help the APF deal with load variations. Hence, by detecting and regulating the dc-link 2050

voltage, the shunt APF can recognize and respond against load variations without the load current measurement. CONTROL SIGNAL COMPUTATION FOR FOUR SWITCH APF The four-switch APF is introduced by replacing the traditional three-phase VSI with the FSTPI without degrading the performance of the proposed control strategy. The FSTPI, which is composed of four power switching devices and two split capacitors, has been applied for low-cost ac motor drives. Current controller is changed into control signals of the four-switch APF as the following equations: v * Fa= (3/2)v * Fα + (1/2)v * Fβ (2) v* Fb = 2 v * Fβ (3) where v* Fa and v* Fb are the control signals for leg a and b of the four-switch APF, respectively. CURRENT CONTROLLER DESIGN In order to designing of PI-VPI controller and investigate the effect of these gains on control performance, the closed-loop transfer function of the PI- VPI current controller defined. By selecting the resonant gains K rh= K phr F/L F and K i1= Kp1RF /LF, In fact, Kp1 is the integrator gain of the PI controller that does not affect the harmonic compensation performance of the VPI controller. Thus, for the sake of simplification, Kp1 is kept constant, and K phis changed to determine the control performance of the VPI controller [5]. VPI controller is more selective and obtain better steady-state performance if K phis a smaller value. In harmonic compensation application, the steady-state performance is regarded as the most critical index DESIGN OF THE ARTIFICIAL NEURAL NETWORK The artificial neural network simulator processes the Ii's corresponding to each section and determines if the section should be recommended or not. It is organized in three layers of neurons, the input neurons that receive the information from the input processor, the hidden neurons that link the neurons in the other two layers, and the output neurons (only one in this case) that sends the results to the output processor. Figure-5. Scheme of the Artificial Neural Network. The first step conducted by the neural network simulator is to process the input of each neuron i of the input layer, Ii, to a scale of 0 to 1; this is the activation level, ai, of the neuron i. The scaled values or activation levels are transmitted to all connected neurons in the hidden layer. At the hidden layer, each neuron h computes its input, I h, adding the level of activation (ai) of all connected input neurons weighted by the weights of the connections (wih). This input I his then processed to an activation level, ah, using an activation functional= f(i h). At the output layer, the input for the output neuron, Io, is computed adding the ah 's of the connected hidden neurons weighted by the connection weights (who). This input Io is processed to the output of the network, oo, using the activation formula. Finally, the output processor translates the numeric output received from the simulator. SIMULATION MODEL OF SHUNT ACTIVE POWER FILTER WITH DISTRIBUTION SYSTEM Figure-6. Simulation model of distribution system with shunt active filter. 2051

Figure-7. Simulation model of control circuit. Figure-10. Steady state performs with ANN controller for RL load. Figure-8. Simulation model of PI+VPI controller. SIMULATION MODEL OF ANN CONTROLLER In this ANN controller feed forward, two layer networks can be used as current controller and its simulation model as shown in Figure-9. In this two ANN blocks are connected in place of PI+VPI controllers. The error signal is given to the ANN controller which gives voltage signal and it is added to the supply voltage and it generates the reference for the generation gate pulses for 4-switch three phase inverter. Figure-11. Steady state performs with ANN controller for RLC load. Figure-12. THD factors with ANN controller for RL load. Figure-9. Simulation model of control circuit with ANN controller. SIMULATION RESULTS WITH ANN CONTROLLER Figure-13. THD factors with ANN controller for RLC load. EXPERIMENTAL RESULTS The system consists of a 1.5-kVA shunt APF and a 3-kVA nonlinear load with the parameters listed in following Table. 2052

Supply voltage RMS line-line Supply frequency Table-1. System parameters. 127V 50Hz 5 th harmonic supply voltage 10% of the fundamental component 7 th harmonic supply voltage 10% of the fundamental component DC link reference voltage for the six * switch APF V dc 260v DC link reference voltage for the * four switch APF V dc 420v DC-link capacitor for four switch APF C 1=C 2 1000µF DC-link capacitor for four switch APFC= C 1+C 2 2000µF Filter resistance R F 0.05Ω Filter inductance L F Nonlinear RLC load 2mH R L(min)=12.5 Ω R L(max)=20 Ω L L=1mH C L=2200 µf Figure-10 show that the harmonic currents are effectively compensated and the supply current is almost sinusoidal with a small THD factor of approximately 2.2% whereas the load current is highly distorted with the THD factor of 25.2%. From these results, the effectiveness of the proposed control scheme is verified and harmonic currents are effectively compensated without load. It is verified through experiments that the proposed control strategy has good steady-state performances as well as good dynamic responses with both nonlinear RL and RLC loads. In majority of previous studies, the supply voltage has usually been assumed to be an ideal sinusoidal, but this voltage condition is rare in practical networks. The non-sinusoidal supply voltage condition in practical networks may adversely affect the control performance of the APF. To verify the effectiveness of the proposed control algorithm under such conditions, experiments were carried out where the supply voltage was injected with fifth and seventh harmonic components of 10% and 5%magnitudes of the fundamental component, respectively. The results are illustrated in Figure-16. Figure-14. Steady-state performance with proposed control scheme under RL load. 2053

Figure-15. Steady-state performance with proposed control scheme under RLC load. Figure-16. Steady-state performance of the proposed control scheme under distorted supply voltage condition with RL load. Figure-17. Steady-state performance of the proposed control scheme under distorted supply voltage condition with RLC load As shown in Figure-16, the harmonic compensation performance of the APF is not deteriorated by the distorted supply condition where the supply current was also close to sinusoidal and similar with the results shown in Figures 15 and 14. Where an ideal sinusoidal supply voltage is given. There are only small increases in THD factors, approximately 2.32% and 2.38% for the cases of nonlinear RL and RLC loads, respectively. THD factor for PI+VPI controller with RL and RLC load Figure-18. THD factor of RL load. 2054

for three-phase shunt active power filter. IEEE Trans. Ind. Electron. vol. 57, no. 10, pp. 3364-3375, October. [5] H. Akagi, E.H. Watanabe and M. Aredes. 2007. Instantaneous Power Theory and Applications to Power Conditioning. M. E. El-Hawari (Ed.). New York: Wiley. Figure-19. THD factor of RLC load. FUTURE ENHANCEMENTS The performance of shunt Active Power filter can be improved further in place of two level voltage source inverter multilevel inverter used as Shunt active power filter and harmonics in source voltages can be eliminated by implement as hybrid filter. This work is based on three phase three wire system and the active filter does not work well if there is a zero sequence in the supply voltage. In future, a detailed analysis can be carried out for a 3 phase four wire filter in order to compensate the zero sequence present in the system. CONCLUSIONS The shunt APFs are recognized as a flexible solution for harmonic current compensation. Since they are capable of compensating harmonic currents generated by nonlinear loads as well as providing a fast responses to load variations. Due to reactive power compensation by shunt active filter the power factor will be maintained unity. The PI controller is not suitable for higher order harmonic compensation. PI plus Resonant controller is used for compensating the harmonic currents but in the frequency response an undesirable peaks are appeared. Due to this the stability margin will be reduced. Here ANN technique is used to further reduce THD of supply current, dynamic response. [6] Limits for Harmonic Current Emission, IEC 61000-3- 2, 2001. [7] F. Z. Peng. 1998. Application issues of active power filters. IEEE Ind. Appl. Mag. vol. 4, no. 5, pp. 21-30, September/October [8] H. Akagi. 1996. New trends in active filters for power conditioning. IEEE Trans. Ind. Appl. vol. 32, no. 2, pp. 1312-1332, November/December. [9] Recommended Practice for Harmonic Control in Electric Power Systems, IEEE Std. 519-1992, 1992. REFERENCES [1] An Advanced Current Control Strategy for Three- Phase Shunt Active Power Filters Quoc-Nam Trinh and Hong-Hee Lee, Senior Member, IEEE 2013 [2] H. Hu, W. Shi, Y. Lu, and Y. Xing. 2012. Design considerations for DSP controlled 400 Hz shunt active power filter in an aircraft power system. IEEE Trans. Ind. Electron. vol. 59, no. 9, pp. 3624-3634, September. [3] Z. Chen, Y. Luo, and M. Chen. 2012. Control and performance of a cascaded shunt active power filter for aircraft electric power system. IEEE Trans. Ind. Electron. vol. 59, no. 9, pp. 3614-3623, September. [4] S. Rahmani, N. Mendalek, and K. Al-Haddad. 2010. Experimental design of a nonlinear control technique 2055