ED701 General Industry Pressure Transmitter

Similar documents
DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Relative and absolute pressure transmitter type 528

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Relative and absolute pressure transmitter type 528

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Pressure transmitter for general industrial applications Model A-10

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

SUNSTAR 传感与控制 TEL: FAX: Relative and absolute pressure transmitter type 528

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Flush pressure transmitter For viscous and solids-containing media Model S-11

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Relative pressure transmitter type 522 for shipbuilding

Materials (other materials see WIKA diaphragm seal program) Model S-10

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Pressure transmitter For general industrial applications Model A-10

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

NAT Applications. Features

SATRON VB Pressure Transmitter

NAT Applications. Features

High-quality pressure transmitter For general industrial applications Model S-20

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

ECT Applications. Features

High-quality pressure transmitter For general industrial applications Model S-10

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

Pressure Transmitter SIL

Technical Data Measuring principle Thick-film-on-ceramic 25 C typ. ± 0.3 % FS typ. (± 0.5 % FS typ., ± 1 % FS typ.)

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Electronic Temperature Transmitters

OEM pressure transmitter For mobile working machines Model MH-3

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

ph or ORP Transmitter

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

Screw-in resistance thermometers with plug connector

SALES SERVICE +358 (0)

Submersible pressure sensor For oils and fuels Model LF-1

PAD - Heavy Duty Differential Pressure Trasmitter

General Specification

PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS

INDUSTRIAL PRESSURE TRANSMITTER

Industrial Pressure Transmitter

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Digital inductive conductivity transmitter

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

SITRANS P. Transmitters for level. Introduction 1/42. Application

OEM Relativ- und Absolut-Drucktransmitter OEM Relative and absolut pressure transmitter OEM Transmetteur de pression relative et absolue

DTM.OCS.S/N - Modbus Level Transmitter

Submersible pressure sensor For water and wastewater Model LW-1

Rudder or propeller angular position transmitter KINAX WT720

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

MICROMACHINED SILICON MODULAR PRESSURE SENSOR

Field IT 2600T Series Pressure Transmitters

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

Valve Island with Electronic I/O

Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm

Electronic Pressure Measurement

Low Pressure NSL Applications. Features

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763)

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

Design and applications

Level sensing pressure transmitter type 711

Ult r a s o n i c le v e l me t e r s ULM 55

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Submersible pressure sensor For superior applications Model LF-1

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

CTE7000 Series Miniature pressure transmitters

Resistance thermometer Model TR30, compact design

DRS390 High stability, flange mounting

Ult r a s o n i c le v e l me t e r s ULM 70

KFS. Flap-type flow meter. Design and range of application

Inductive Conductivity Meter ILM

Conductivity Transmitter

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm

Digital flow ELEMENT transmitter for continuous flow measurement

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Coriolis Massflowmeter

Datalogger DL/N 70 Version:

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

Field IT 2600T Series Pressure Transmitters

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Resistance Thermometers Model Series TR7X0, Sheathed Design

Non-Submersible Industrial Pressure Transducer

Mid-West. Instrument. Model 142 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Electronically controlled proportional pressure regulating valves

Digital flow ELEMENT transmitter for continuous flow measurement

Level gauges Series LT Level indicator, switch and transmitter for liquids

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

CTE8000 Series OEM pressure transmitters for industrial media

Your Global Automation Partner. PT2000 Pressure Transmitter

Transcription:

ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response time < 25 ms (option 5 ms) High long-term stability Excellent repeatability Active compensation for temperature drifts ATEX II 1G, II 2G, II 1/2G and II 1D Lloyd s Register Approval The large choice of pressure and electrical connections makes the ED701 series suitable for a large variety of applications. The ED701 pressure transmitters are available in 4 20mA current loop or in voltage output signal versions. These transmitters offer a very high accuracy over a wide temperature range, an excellent repeatability and long time stability as well as a short response time (down to 5 ms). The piezo-resistive silicon sensor is anodic bonded on a very stable glass base, which is attached to a stainless steel construction. This assembly guarantees an excellent thermal isolation. The sensor is isolated from the process by a stainless steel diaphragm (1.4435 / 316L) and a filling liquid. The electronic is located within the hermetically sealed transmitter housing which gives the ED701 an excellent resistance to humidity, shock and vibration. Protection class, from IP 65 to IP 67 only depends on the choice of the electrical connection. The electronic is a state-of-the-art signal processing unit fitted with a fast micro-controller allowing the compensation of drift effects due to temperature on the sensor signal, over a wide temperature range with a fast response time. The ED701 is available with a great variety of pressure and electrical connections to meet all requirements. The electrical connection can be replaced easily and gives access to the Autozero adjustment. The ED701 is a very flexible transmitter suitable for all types of industrial applications. According to its ATEXapproval the ED701 can be used in potentially explosive atmospheres (gases, vapors and dust). The ED701 has got the Lloyd s Register approval, which makes it the ideal product for environments such as in the marine, offshore and industrial applications. ED701 with flush diaphragm: refer to the datasheet ED701_Hygienic (D6.181, ED701 Hygenic Pressure Transmitter) Design and specifications subject to change without notice Page 1

Ordering details digit: Positions 1 2 3 4 5 6 7 8 9 10 11 12 Process connection Male thread G 1 2 EN 837-1 1 Male thread G 1 4 EN 837-1 2 Male thread M20x1.5 DIN 16288 3 Male thread G 1 2 DIN 3852 with O ring 1 ) 4 Male thread G 1 8 EN 837-1 5 Female thread G 1 2 DIN 3852 6 Female thread G 1 4 DIN 3852 7 Male thread 1 2-14NPT, ASP N152 A Female thread 1 4-18NPT, ASP N152 B Male thread 7 16-20UNF E Specific process connection (additional code needed) 0 Output signal 4... 20 ma 2 0... 10 V DC 4 0... 5 V DC 5 Approval CE conform 0 ATEX 4 ) 1 Lloyd s Register 2 ) 3 Lloyd s Register 2 ) + ATEX 4 ) 4 Electrical connection 2 meter shielded cable 3 conductors, IP 65 1 2 meter shielded cable 3 conductors, IP 67 9 Fischer Plug, IP 67 2 DIN 41524 Binder Plug, IP 65 3 DIN 43650 Plug, IP 65 4 Bendix 6 pole Plug, IP 65 5 M12, 4 pole Industrial Plug, IP 67 6 1 2 NPT, cable length 1 m, IP 67 7 Field Housing, cable gland brass nickel-plated, IP 67 3 ) A Field Housing, cable gland stainless steel, IP 67 3 ) B Field Housing cable gland PA, IP 67 3 ) C Field Housing M12 Plug, stainless steel, IP 67 D Accuracy Medium temperature up to 125 C 0.4% FS, compensated temperature range 10 +125 C 1 0.2% FS, compensated temperature range 10 +125 C 2 0.1% FS, compensated temperature range 10 +80 C 3 5 ms response time 0.4% FS, 5 ms, compensated temperature range 10 +80 C 6 0.2% FS, 5 ms, compensated temperature range 0 +60 C 7 High medium temperature Only possible with the cooling adapters (see Accessories) Pressure unit Gauge pressure (100 mbar up to 40 bar) 3 Absolute pressure (400 mbar up to 40 bar) 4 Negative gauge pressure (0 100 mbar, 1 40 bar) 5 Pressure range 100 mbar up to 40 bar: gauge and negative gauge pressure 400 mbar up to 40 bar: absolute pressure See table Pressure range Wetted parts All stainless steel 1 Oil filling FDA approved white oil (Standard) 5 ) 1 Silicon oil) 5 ) 0 1) Pressure connection Code 4: The standard hole through the process connection has a diameter of 2.5 mm. With the option /9355 the pressure connection Code 4 is available with a hole diameter of 10 mm (See Options). 2) Lloyd s Register approved ED701 have a reduced supply voltage range. Check the Lloyd s Register paragraph. 3) Field Housing: The cable gland are compatible with cable diameter of 5 mm to 12 mm. 4) ATEX certification is only available with 4... 20 ma output signal 5) Operating temperature: refer to the technical data. Design and specifications subject to change without notice Page 2

Additional ordering codes The following ordering codes have to be completed with an additional code to be precisely defined: Process connection Code 0 (ordering code position 1) specific process connection The following additional codes are available. Others on request: /9510 G ¼ DIN 3852, Form A, male thread /9512 G ¼ DIN 3852, Form E, male thread Example: ED701 0xx.xxx.xxx.xx /9512 Standard ED701 Delivery Calibration temperature: The ED701 are calibrated at + 25 C. If another calibration temperature is needed, the option /9007/TTTT has to be mentioned, as part of the ordering code (see Options). Electrical connections: No cable socket will be provided. Such accessories have to be ordered separately (see Accessories). Test Certificate: Each ED701 will be delivered with a Test Certificate at the calibration temperature (6 points). If not specified, the Certificate will be in German (see Options). O-Ring seals: The pressure connection 4 ( Position 1) is always delivered with a NBR O-Ring. Other O-Rings are available (see Accessories). The other pressure connections are delivered without any O-rings. Options Specific pressure range: /SETR An application specific pressure range can be defined here. The range must be given in plain text. The smallest available pressure ranges are 100 mbar (gauge and negative gauge pressure) and 400 mbar (absolute pressure).example: /SETR 500 mbar 2500 mbar Specific calibration temperature (temperature of the medium): /9007/TTTT Example: /9007/0100. The ED701 will be calibrated for a medium temperature of 100 C (ex factory). This option is reducing the compensated temperature range at ± 25 C of the calibration temperature. Hole diameter of 10 mm for the process connection Code 4: /9355 Example: ED701 420.413.075.11 /9355. The ED701 with male thread G1/2 DIN 3852 will have a 10 mm hole through the process connection. Language of the Test Certificate and Operating Manual: Both documents are available in German, French and English. The desired language must be specified in plain text with the ordering code. Standard will be German. Pressure range Code Range Code Range Code Range Code Range mbar mbar bar bar 126 0...100 B06 0...150 136 0...160 A56 0...200 146 0...250 B26 0...300 B36 0...350 156 0...400 A66 0...500 166 0...600 B46 0...700 176 0...1000 P46 0...1250 B56 0...1400 186 0...1600 D06 0 100 20 ) D16 0 160 20 ) D26 0 200 20 ) D46 0 400 20 ) D56 0 500 20 ) D66 0 600 20 ) A76 0...2000 196 0...2500 206 0...4000 A86 0...5000 216 0...6000 P76 0...7300 226 0...10000 P86 0...18300 H66 100 100 20 ) H76 200 200 20 ) H86 500 500 20 ) C46 200 0 20 ) C56 500 0 20 ) 20) Negative gauge pressure ranges: only available with the pressure unit code 5 ( Position 6). L25 1...10 015 0...0.6 025 0...1 035 0...1.6 A15 0...2 045 0...2.5 L35 0...2.8 055 0...4 A25 0...5 065 0...6 L45 0...7 L05 0...8 075 0 10 L15 0 12 085 0 16 A35 0 20 095 0 25 L55 0...30 105 0...40 D85 0 1 20 ) E05 0.1 1 20 ) E15 0.1 2 20 ) 315 1 0 20 ) H05 1 1 20 ) 525 1 3 20 ) 535 1 5 20 ) 545 1 9 20 ) E65 1 1.6 20 ) F05 1 2 20 ) F15 1 10 20 ) F45 1 12.5 20 ) F25 1 20 20 ) F35 1 24 20 ) F65 1 40 20 ) Design and specifications subject to change without notice Page 3

Code Range Code Range Code Range psi psi in H 2 O [4 C] 05D 0...1.5 06D 0...2.5 07D 0...3 08D 0...4 09D 0...6 45D 0...7.5 10D 0...10 11D 0...15 12D 0 30 13D 0 60 51D 0 75 14D 0...100 15D 0...150 16D 0 200 17D 0 300 18D 0 400 32D 0 500 70D 1.5 1.5 20 ) 71D 3 3 20 ) 72D 6 6 20 ) 80D 15 15 20 ) 60D 1.5 0 20 ) 61D 3 0 20 ) 62D 6 0 20 ) 81D 15 30 20 ) 82D 15 60 20 ) 83D 15 150 20 ) 17G 0...40 18G 0...50 19G 0...60 22G 0...100 30G 0...300 40G 0...750 Code Range Code Range Code Range Code Range mm H 2 O [4 C] m H 2 O [4 C] m H 2 O [4 C] m H 2 O [4 C] 177 0...1000 P47 0...1250 187 0...1600 A77 0...2000 197 0...2500 207 0...4000 A87 0...5000 217 0...6000 P77 0...7300 227 0...10000 P87 0...18300 028 0...1 038 0...1.6 A18 0...2 048 0...2.5 L38 0...2.8 058 0...4 A28 0...5 068 0...6 L48 0...7 L08 0...8 078 0...10 L28 1...10 L18 0...12 088 0...16 A38 0...20 098 0...25 L58 0...30 L78 0...32 108 0...40 A48 0...50 118 0...60 L88 0...64 L68 0...70 128 0...100 L98 0...128 B08 0...150 138 0...160 A58 0...200 148 0...250 B28 0...300 B38 0...350 158 0...400 H08-1...1 20 ) H18-2...2 20 ) H28-5...5 20 ) H38-10...10 20 ) C08-2...0 20 ) C18-5...0 20 ) D88 0...-1 20 ) E08-0.1...1 20 ) E18-0.1...2 20 ) E68-1...1.6 20 ) F08-1...2 20 ) F18-1...10 20 ) F28-1...20 20 ) F38-1...24 20 ) F48-1...12.5 20 ) Code Range Code Range Code Range Code Range MPa KPa KPa KPa 013 0...0.6 023 0...1 033 0...1.6 A13 0...2 043 0...2.5 053 0...4 883-0.1...0.9 20 ) E03-0.1...1 20 ) E13-0.1...2 20 ) 072 0...10 L22 1...10 L12 0...12 082 0...16 A32 0...20 092 0...25 L52 0...30 L72 0...32 102 0...40 A42 0...50 112 0...60 L82 0...64 L62 0...70 122 0...100 132 0...160 A52 0...200 142 0...250 B22 0...300 B32 0...350 152 0...400 A62 0...500 162 0...600 B42 0...700 172 0...1000 P42 0...1250 B52 0...1400 182 0...1600 A72 0...2000 192 0...2500 202 0...4000 H32-10...10 20 ) H42-20...20 20 ) H52-50...50 20 ) H62-100...100 20 ) 352-10...0 20 ) 362-16...0 20 ) C22-20...0 20 ) 372-25...0 20 ) 382-44...0 20 ) C32-50...0 20 ) 392-60...0 20 ) 402-100...0 20 ) C92 0...-60 20 ) D02 0...-100 20 ) 642-10...15 20 ) 652-15...10 20 ) 662-15...25 20 ) 672-25...15 20 ) 682-20...40 20 ) 692-40...20 20 ) 702-40...60 20 ) 712-60...40 20 ) 722-60...100 20 ) 732-100...60 20 ) 742-100...150 20 ) G02-100...200 20 ) 922-100...300 20 ) 932-100...500 20 ) 20) Negative gauge pressure ranges: only available with the pressure unit code 5 ( Position 6).. Design and specifications subject to change without notice Page 4

Technical data Measurement characteristics Pressure range Gauge pressure: from 0 100 mbar up to 0 40 bar. Absolute pressure: from 0 400 mbar up to 0 40 bar. The standard pressure ranges are listed in the pressure range table. Other specific ranges are available with the option SETR. Overpressure limit Pmax. Depending on the pressure range 0.. P P [bar] 0,1..0,35 0,4..1,0 1,6..5 6..20 25 30..40 Maximum overpressure P max [bar] 1 3 15 60 70 135 Accuracy 0.1%FS, 0.2%FS und 0.4%FS classes (see ordering code Position 5). Hysteresis and repeatability Long term stability ± 0.05% FS ± 0.2% FS / year Response time (10 90%) 25 ms 5 ms with the accuracy codes 6 und 7 ( Position 5). Temperature influence (in compensated range) Depending on the accuracy class:, Position 5 = 1 and 6 (class 0.4%) Zero: TC ± 0.20% FS / 10K. Span: TC ± 0.15% FS / 10K., Position 5 = 2 and 7 (class 0.2%) Zero: TC ± 0.15% FS / 10K. Span: TC ± 0.10% FS / 10K., Position 5 = 3 (class 0.1%) Zero: TC ± 0.05% FS / 10K. Span: TC ± 0.05% FS / 10K. Admissible temperature of the medium, Position 11 ED701 with FDA approved white oil (Standard): 10 C +125 C ED701 with silicon oil: 30 C +125 C For high medium temperatures (from 120 C and up) the ED701 absolutely has to be mounted on a high temperature adapter. (See Accessories). Ambient temperature (housing) -10 C +80 C Storage temperature -10 C +80 C Materials specification Wetted part Stainless Steel 1.4435 (AISI 316L) Parts not in contact with medium Stainless Steel 1.4301 (AISI 304) and 1.4305 (AISI 303) and electrical connector material. Certificate EN10204 3.1 available on request Electrical specification Supply voltage 9...30 V DC (4 20 ma) 10...28 V DC (4 20 ma EEX) 14...24 V DC (4...20 ma Lloyd s Register) 15...30 V DC (0 10 and 0...5 V DC) 20...24 V DC (0 10 and 0...5 V DC Lloyd s Register) Insolation Resistance >1 GOhm, 500 V DC Load (current output) R L 50 x U B - 450 Load (voltage output) R L 5 kohm Protected against reverse signal polarity. Switch ON time 5 sec. EMC Influence of EMC Less than 0.15% FS Conformity EN 61000-6-3, EN 61000-6-2, EN 61326, EN 50121-4 ATEX data Intrinsically safe conforming to EN 50020 and EN 50281-1-1 Applications: II 1G II 1D Device located in zone 0/zone 20 II 1/2G II 1D Pressure connection in zone 0/zone 20 Housing and electrical connection in zone 1/zone 20 II 2G II 1D Device located in zone 1/zone 20 Intrinsically safety EEx ia IIC. The device can only be connected to an approved intrinsically safe current loop with the following boundery values: U 0 = 28 V I k = 100 ma P = 1.5 W The device internal capacity and inductivity values are: C i = 1 nf L i = 0.1 mh For the application in EEx zone you have to respect the conditions mentioned in the ATEX Type Examination Certificate. You find the certificates and manuals under http://www.baumerprocess.com/en/downloads/ Environmental specification Humidity According to EN 60068-2-38 Vibrations According to EN 60068-2-6 Shocks According to EN 60068-2-31 Protection class Rating IP 65 and IP 67, depending on electrical plug. Mounting Position at calibration time: Vertical Physical characteristics Weight Between 223 and 885 g depending of the version. Dimensions See drawings. Disposal of product and packing According to national laws or by returning to the manufacturer. Design and specifications subject to change without notice Page 5

Technical data Zero adjustment and factory setting: The zero adjustment and factory setting are directly available on the ED701 by removing the electrical plug. A push button on the top of the electronic unit can be activated. Zero adjustment: By pressing the push button the applied pressure will be considered as the new zero point and the output signal will be reset (i.e. 4 ma or 0 VDC). This function allows some corrections when the mounting position influences the measurement, when temperature or long term drifts occurs and when a resetting in a level measurement application is needed. Factory setting (zero): The factory setting can be reloaded at any time. To do it the push button must be pressed during at least 10 seconds. Oil filling Standard: The standard oil filling is the FDA approved white oil (Paraffin oil). This is the best choice for all the applications in the food, beverages, pharmaceutical and biotech industries. ED701 with this oil filling should not be used below 10 C and above +125 C, it could severly damage the ED701. Alternative: The silicon oil can be recommended for all general industrial applications. ED701 with silicone oil can be used in a temperature range from -30 C up to +125 C. Lloyd s Register (LR) The ED701 has been tested with satisfactory results in accordance with the requirements of the LR Type Approval System. Certificate number: 06/20034. (Expires: 29 August 2011). Applications: Marine, offshore and industrial applications for use in environmental categories ENV1, ENV2 and ENV3 as defined in Lloyd s Register s Type Approval System, Test Specification Number 1-2002. Limitations: The supply voltage range of ED701 is is reduced compared to the non LR approved ED701. (Please refer to the paragraph Technical data - Electrical specification). According to the curve below the allowed ambiant temperature for Lloyd s Register approved ED701 is derated at medium temperatures above 150 C (ED701 with high temperature adapter). T ambient 80 ºC 60 ºC Allowed Zone -10 ºC 150 ºC 200 ºC T medium Pressure connection availability Overview table Code Pressure connection Material Oil filling Accuracy 1.4435 FDA Silicon P < 1 bar P 1 bar 0.1% FS 0.2% FS 0.4% FS 1 Male thread G 1 2 EN 837-1 2 Male thread G 1 4 EN 837-1 3 Male thread M20x1.5 DIN 16288 4 Male thread G 1 2 DIN 3852 with O ring 5 Male thread G 1 8 EN 837-1 6 Female thread G 1 2 DIN 3852 7 Female thread G 1 4 DIN 3852 A Male thread 1 2-14NPT, ASP N152 B Male thread 1 4-14NPT, ASP N152 E Male thread 7 16-20UNF Available Design and specifications subject to change without notice Page 6

Drawing (all dimensions in mm) DIN 43650 plug Code: 4 Bendix 6 pole plug Code: 5 Cable 3 conductors IP 65 / IP 67 Code: 1 (IP 65) 9 (IP 67) DIN 41524 Binder plug Code: 3 17 17 10.4 14 Fischer plug Code: 2 NPT 3 conductors Code: 7 M12 industrial plug Code: 6 Field housing Code: A, B, C and D 55 14.5 SW 27 10 10.4 55 61.5 Code Thread d 1 l 1 A 1 2-14NPT 20 Code Thread d 1 d 2 d 3 l 1 l 2 E 7 16-20UNF 9.2 4.5 9 4.5 key 27 key 27 key 27 d 3 l 3 l 2 l 1 23 d 1 13.6 23 l 1 d 1 25 l 1 key 27 45 d 3 d 2 l 2 l 1 23 key 27 d 1 d 2 l 1 l 2 23 d 2 d 1 d 1 Code Thread d 1 d 2 d 3 l 1 l 2 l 3 1 G 1 2 17.5 6 20 3 3 2 G 1 4 9.5 5 13 2 2 3 M20x1.5 17.5 6 20 5 2 5 G 1 8 8 5 10 2 2 Code Thread d 1 l 1 4 G 1 2 14 Code Thread d 1 d 2 l 1 l 2 6 G 1 2 28 15 17.5 7 G 1 4 26 12 14 B 1 4-18NPT 26 10.2 12.5 Design and specifications subject to change without notice Page 7

Mounting example Pressure port: Code A Pressure port: Code E Screw hole Screw hole Pressure port: Code 1, 2, 3, 5 Seal Pressure port: Code 6, 7, B Seal Screw hole Pressure port: Code 4 Screw hole Seal Screw hole Connecting diagram Electrical connection For Voltage signal Output 0 max. 10 V a For 4... 20 ma current loop version b I A UA RL U B a U B c b I A R L d d Pin assignment Contact DIN 43650 plug Bendix 6 poles plug Cable 3 conductors DIN 41524 Binder plug 4...20 ma 0...5/10 V DC 4...20 ma 0...5/10 V DC 4...20 ma 0...5/10 V DC 4...20 ma 0...5/10 V DC a 1 1 B B Blue Blue 3 3 b 2 2 E E Brown Brown 1 1 c - 3 - D - Black - 4 d GND GND Case Case Shield Shield Case Case brown black View soldering side, cable socket blue shield Pin assignment Contact Fischer plug NPT 3 conductors M12 industrial plug Field housing 4...20 ma 0...5/10 V DC 4...20 ma 0...5/10 V DC 4...20 ma 0...5/10 V DC 4...20 ma 0...5/10 V DC a 1 1 Red Red 3 3 1 1 b 2 2 Black Black 1 1 2 2 c - 3 - Green - 4-3 d Case Case Case Case 4 4 View soldering side, cable socket red black green Design and specifications subject to change without notice Page 8

Accessories Adapter for high temperature (cooling device) EN 837-1 DIN 3852 d G 1 2 G 1 2 l T Code 2 ) T med max. l T d Connection Material 1 300 C 123 40 G 1 2 Stainless steel 1.4435 D 12361.0 1 200 C 95 27 G 1 2 Stainless steel 1.4435 D 12361.1 EN 837-1 EN 837-1 d G 1 2 G 1 2 l T Code 2 ) T med max. l T d Connection Material 1 300 C 131 40 G 1 2 Stainless steel 1.4435 D 12361.2 1 200 C 103 27 G 1 2 Stainless steel 1.4435 D 12361.3 EN 837-1 d G 1 2 1 2 14-NPT l T Code 2 ) T med max. l T d Connection Material 1 300 C 125 40 1 2 14-NPT Stainless steel 1.4435 D 12361.6 1 200 C 97 27 1 2 14-NPT Stainless steel 1.4435 D 12361.7 2) Cross reference to ordering code position 1, process connection. Electircal sockets Cable socket connector DIN 43650 E 6844.0 Cable socket connector M12 E 15560.0 SW 19 Cable socket connector Binder E 13265.0 Cable socket connector M12 E 15560.1 35 Cable socket connector Bendix E 6586.1 20 Cable socket connector Fischer E 13267.0 35 9 52.5 M12x1 Design and specifications subject to change without notice Page 9

Accessories Cable Cable with M12 socket connector for ED701 E 15543.x LLL Type Shielded PVC Kabel 0 Shielded PUR Kabel 1 Length 2 meters 002 5 meters 005 10 meters 010 20 meters 020 O-Rings The O-rings for the pressure connection 4 (ordering code Position 1) are available in NBR, EPDM and Viton (FPM). The following operating temperature of the O-rings are only indicative values (dry air): NBR (FDA): 25 + 125 C EPDM (FDA): 40 + 160 C FPM / Viton (FDA): 20 + 200 C Pressure connection Designation Material 4 O-Ring for male thread G 1 2 (at the rear) NBR (FDA) A8550.9110 4 O-Ring for male thread G 1 2 (at the rear) FPM / Viton (FDA) A8550.9111 4 O-Ring for male thread G 1 2 (at the rear) EPDM (FDA) A8550.9112 Viton is a registered trademark of DuPont Performance Elastomers D6.180/UK/2008-09-22 This data sheet may only be reproduced in full. Design and specifications subject to change without notice Page 10