INSTRUCTION MANUAL Fax: (503)

Similar documents
INSTRUCTION MANUAL UTL260

INSTRUCTION MANUAL DL49

INSTRUCTION MANUAL Fax: (503)

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

USER'S MANUAL DMR-6700

200Amp AC Clamp Meter + NCV Model MA250

DM-46 Instruction Manual

Autoranging Multimeter Extech EX503

INSTRUCTION MANUAL DL Fax: (503)

User s Guide. 400A AC/DC Clamp Meter. Model MA220

DM-46 Instruction Manual

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

NOTE: Fully read and understand this manual before using this Digital Multimeter.

DCM730. Digital Clamp Meter User s Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

DL389 G2PHOENIX PRO+ True RMS Clamp Meter

INSTRUCTION MANUAL INF Fax: (503)

Not for Reproduction

DL389 G2PHOENIX PRO+ True RMS Clamp Meter

400Amp True RMS AC/DC Clamp Meter Model EX613

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

User s Guide. Digital AC/DC Clamp Meter Model 38394

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL DLM2

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

User Guide. Digital AC/DC Clamp Meter Model 38394

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

INSTRUCTION MANUAL DL Fax: (503)

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

netzerotools.com 374/375/376 Users Manual Clamp Meter

MODEL: D03128 CLAMP METER

600A Clamp Meters w/tightsight Display

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

User Manual. All rights reserved. Specifications are subject to change without notice.

Mini Clamp Meter Model:

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

AUTORANGING TRUE RMS MULTIMETER USER GUIDE. INST151 Doc 1.00

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

400Amp True RMS AC Clamp Meter + NCV

OPERATING INSTRUCTIONS

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

374/375/376 Clamp Meter

OPERATING INSTRUCTION

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

312, 316, 318. Clamp Meter. Users Manual

USER S MANUAL DMR-1500

User Manual Digital Multimeter. model no.: MSR-U1000

MS2109A AC/DC Clamp Meter. User Manual. Contents

INSTRUCTION MANUAL ADM Fax: (503)

DM-45 Digital Multimeter

AC/DC CLAMP METER USER S MANUAL

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

USER'S MANUAL DMR-4350

374/375/376 Clamp Meter

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

User Manual. All rights reserved. Specifications are subject to change without notice.

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL- KM 2782 / 2782-T

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

Digital Clamp Meter (TRMS) Model : 2727

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

CONTENTS MS2033A. 1.Introduction Safety Information...01

INSTRUCTION MANUAL DMEG3/IRT Fax: (503)

ICM 136R Operating Instruction Electrical Clamp-Multimeter

AM-520 AM-530. Users Manual. HVAC Multimeter. True-rms Electrical Contractor Multimeter

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

R/C SMD Tweezers Multimeter Model RC200

User's Manual. Clamp-on Power Datalogger. Model

Instruction Manual IDM 61/62T Digital Multimeter EN DE ES IT FR

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

User s Guide. Model MA A AC Mini Clamp-on Meter

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

DIGITAL CLAMP METER Use s Manual

Pen Multimeter. Model

15B & 17B. Users Manual. Multimeters

True RMS Digital Multimeter Model:

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

UT207A/208A/209A Operating Manual. Table of Contents

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

User Manual Digital Clamp Multimeter. model no.: MSR-C600

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

902 FC. HVAC True-rms Clamp Meter

IDM 61/62T Instruction Digital Multimeter Manual

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

Digital Clamp Meter Model: &

Digital automotive analyser 13 function with ic

True RMS AC / DC Power Clamp Meter Model

374 FC/375 FC/376 FC Clamp Meter

Transcription:

INSTRUCTION MANUAL 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com email: info@ueitest.com

Introduction The Phoenix Series is a hand-held, battery powered digital multimeter with clamp-on current measuring capability, back light and work area light.. Features include 3-3/4 digit, 4000 count LCD display Auto-ranging measurement with manual ranging (Amps or adapters only) capability MIN/MAX (Peak Hold) (all ranges except Frequency) Frequency/Duty Cycle/Data Hold Auto power off with manual override Detachable current probe with optional current hook adapter for tight spaces Built-in test lead storage & magnetic mount Backlit display & Workligh DL279 & DL289 Temperature/Non-Contact Voltage/Dual display TRMS Measurement (DL289 only) Safety Notes Before using this meter, read all safety information carefully. In this manual the word "WARNING" is used to indicate conditions or actions that may pose physical hazards to the user. The word "CAUTION" is used to indicate conditions or actions that may damage this instrument. If any of the following indications occur during testing, turn off the power source to the circuit under test: Arcing Flame Smoke Extreme Heat Smell of Burning Materials Discoloration or Melting of Components H i gher voltages and currents re q u i re greater awareness of physical safety h a z a rds. Before connecting the test leads; turn off the power to the circ u i t under test; set the meter to the desired function and ra n ge; connect the test leads to the meter first, then connect to the circuit under test. Reapply p o w e r. If an erroneous reading is observed, disconnect power immediately and recheck all settings and connections. This meter is designed for trade professionals who are familiar with the hazards of their trade. observe all recommended safety procedures that include proper lock-out utilization and the user of personal protective equipment that include safety glasses, gloves and flame resistant clothing. International Symbols Do not attempt to measure any voltage that exceeds the category based rating of this meter Do not attempt to use this meter if either the meter or the test leads have been damaged - Turn instrument in for repair at a qualified repair facility Ensure meter leads are fully seated by making a quick continuity check of the leads prior to making voltage measurements Keep your fingers away from the test lead s metal probe contacts when making measurements - Always grip the leads behind the finger guards molded into the probes Do not open the meter to replace batteries or while the probes are connected Controls and Indicators 2 Exceeding the specified limits of this meter is dangerous and can expose the user to serious or possibly fatal injury. Voltages above 60 volts DC or 25 volts AC may constitute a serious shock hazard Always turn off power to a circuit (or assembly) under test before 7 8 cutting, unsoldering, or breaking the current path - Even small 9 amounts of current 10 can be dangerous 13 11 14 Always disconnect the live test lead before disconnecting the 12 common test lead from a circuit 15 In the event of electrical shock, ALWAYS bring the victim to the 16 18 emergency room for evaluation, regardless of the victim s apparent 17 recovery - Electrical shock can cause an unstable heart rhythm that may need medical attention 1. Clamp: Measures inductive AC current. Opens to 1. 25 (32 mm). 2. W i re Separation Ta b : Used to separate bundled wires to aid in measuring. DL269/DL279/DL289-MAN P. 1 1 3 6 4 5

3. Conductor Alignment Marks: Used to aid in the visual alignment of a conductor when measuring inductive amperage. Greatest accura cy is achieved when the conductor inside the clamp is centered at the intersection of these marks. 4. Test Lead Holder: Used for hands-free use of one of the test probes. 5. Hand Guard : Used as a point of reference for the operators safety. 18. Multifunction Input Port: Used for measuring AC/DC Volts, Frequency or Duty Cycle, Resistance, Diode, Continuity and Capacitance. Displays and Indicators Always keep your hands and fingers behind the hand guards when measuring current on exposed conductors. Contact may result in serious injury.. 6. Clamp Le ve r : Opens and closes current clamp jaw. NOTE: The clamp uses a high tension spring to close the jaw. Do not allow fingers or objects to become pinched in the base as jaw closes DL269 DL279/DL289 7. MIN/M AX Button: Activates MIN / M AX capture function, cycles through minimum value, maximum value. Press longer than two seconds to return to current reading. 8. NCV/Range Button: Activates non-contact voltage function when meter is off. Used to select R a n g e for the upper display when meter is on. (NCV only available on DL279 / D L 28 9 ) 9. Upper Display (DL279/DL289 only): Used to display current when used with UEi clamp or hook adapter. Displays output from other accessories when connected to the UEi meter. 10. Lower Display: Used to display input to test lead jacks. Includes AC/DC Volts, Frequency, Resistance, Diode, Capacitance and AC/DC microamps (μa). 11. Select Button: Used to choose measurement mode from selections with multiple options such as AC or DC volts, AC or DC μa, Resistance, Diode, Capacitance or Continuity, Temperature in F or C. NOTE: Press and hold when turning the meter on to disable auto power off. 12. Hz/Duty Button: Used to scroll through Frequency or Duty Cycle when in the AC Voltage measurement mode. 13. HOLD/Backlight Button: Freezes display or activates display backlight and work area light. 14. Temperature Input Jack: Input jack for k-type thermocouple probe (DL279/DL289 only). 15. Power/Function Selector: Turns meter on and is used to select the range or function. 16. Common Te r m i n a l : The black test lead is plugged into this terminal to supply the ground or low reference for all measurements. 17. Category Max Indicator: Indicates maximum voltage for the rated working category. Do not exceed 1000 volts DC or AC - RMS at either the common or multifunction input ports as measured from earth ground. ~ AC indica t o r = DC indica t o r - I n d i cates a negative value (DC Negative Vo l t a g e ) M a x M aximum value displayed M i n Minimum value displayed A (top display) Display is in Amps from UEi Clamp or Hook adapter A DP (top display) M aximum value displayed Low battery symbol Hold function activated Diode function C o n t i n u i ty function nf / μf Capacitance (nanofarads or microfara d s ) μ A Microamps (1 μa is 0.000001 Amp) H z Fr e q u e n cy measurement % D u ty Cycle measurement m V Millivolts (1 mv is 0.001 Vo l t ) A P O Auto power off mode active AT Auto range function active O. L Displayed if the input value exceeds selected ra n g e Operating Instructions Auto power off After powering off, the meter will turn back on if you perform one of the following; Change the range, move the position of the selector or any other button is pressed. To disable this function; press and hold the "SELECT" button while turning the meter on. The APO indicator will now be off, indicating that the auto power off function is not active. Back-light / work area light Press the HOLD button longer than two seconds to activate the backlight/work area light. The lights automatically turn off after 10 seconds to extend battery life. NOTE: After activating worklight, press briefly to activate hold. Auto / Manual Range In auto range the meter will select the best range for the measured value, and "AT" is displayed in the lower left of the display. Press the "RA NGE" button to cycle through available ranges for the upper display. AT will not be on the display when locked in a specific ra n g e. DL269/DL279/DL289-MAN P. 2

MIN/MAX mode When using the MIN / M AX capture mode for Amps, it is recommended that you first select the range of the expected maximum value. If this is not done it will lock in the lowest range possible for the initial measurement. If the maximum value exceeds this range the meter will capture O. L as the maximum value. Manual ranging will also provide a faster response current input. Data Hold Press the button to activate. This will freeze the reading and range in the display for your review. Measuring AC Amps Press NCV/RANGE to select range prior to MIN/MAX. Measuring AC or DC Volts DL269 Select ADP to measure AC Amps with the clamp head or hook DL279/DL289 Select any range to power the upper display Press Min/Max to activate Max capture, Min capture, or normal display. Press SELECT to change the reading from AC to DC. Measuring AC, DC or μa Measuring Temperature ( D L 279 / D L 289 only) Measuring NCV Optional Extended Clamp Head (CH2) (Sold separately) NOTE: Meter must be in series for μa measurements. Press SELECT to change AC or DC source. Do not exceed 2000μA AC or DC current or damage to the meter may occur. Press SELECT to change scale from F to C. Disconnect test leads from any voltage source and the meter before plugging in thermocouple. Non-Contact Voltage (DL279/DL289 only) Non-contact voltage with the power switch in the off position, press and hold the NCV button and move the meter near this voltage source Measuring Frequency or Duty Cycle Meter must be in AC Volts mode first then press Hz/Duty to change function to Frequency or Duty Cycle. NOTE: Frequency greater than 100Khz will display 0.000 Hz Optional CH2 hook Connection for optional CH2 hook Measuring Resistance, Continuity, Diode and Capacitance Press SELECT to move from Resistance mode to Continuity, diode or continuity mode. NOTE: Remove the hook adapter when not in use to extend battery life. The hook will consume a small amount of battery power when connected to the meter even when the meter display is off. The meter will automatically display A for amps with the CH2 or ADP for other adapters. NOTE: Capacitance - leave the meter connected to the capacitor for 10 seconds or more for the reading to stabilize. Diode - OL in reverse mode and approximate forward voltage drop when connected in forward mode. Continuity - sounds the tone at approximately 50Ω or less. DL269/DL279/DL289-MAN P. 3

Periodic Service M a i n t e n a n c e Repair and service of this instrument is to be performed by qualified personnel only. Improper repair or service could result in physical degradation of the meter. This could alter the protection from electrical shock and personal injury this meter provides to the operator. Perform only those maintenance tasks that you are qualified to do. Cleaning Pe r i o d i cally clean your meter s case using a damp cloth. DO NOT u s e a b rasive, flammable liquids, cleaning solvents, or strong detergents as they may damage the finish, impair safety, or affect the reliability of the s t r u c t u ral components. Battery Replacement Remove screws from battery compartment cover on back of meter and remove cover. Replace batteries with fresh batteries paying attention to p o l a r i ty position. Replace cover and screw s. Specifications 1. AC Amps Measurement - Jaw input (45Hz to 400Hz) 40A 0.01A ±2.9% +15 dgts 600V 400A 0.1A ±1.9% +8 dgts *DL269 400A range only *DL289 45Hz to 400Hz True RMS (Crest factor <3:1) 2. DC Low Amps Measurement (test lead input) 400μA 0.01μA ±1.2% +3 dgts 2000μA / 600V 2000μA 0.1μA 3. AC Low Amps Measurement (test lead input, 45Hz to 400Hz) 400μA 0.01μA ±2.0% +5 dgts 2000μA / 600V 2000μA 0.1μA ±1.5% +5 dgts *DL289 45Hz to 400Hz True RMS (Crest factor <3:1) 4. DC Volts Measurement 400mV 0.1mV ±0.5% +4 dgts 600V 4V 1mV 40V 10mV 400V 100mV 1000V 1V ±0.8% +10 dgts 6. Ohms Measurement 400Ω 100mΩ ±1.0% +4 dgts 600V 4kΩ 1Ω 40kΩ 10Ω 400kΩ 100Ω 4MΩ 1kΩ 40MΩ 10kΩ ±2.0% +4 dgts 7. Diode Test Range Open Circuit Voltage Test Current (typical) Overload Protection 2.0V < 3.0V DC 0.25mA 600V 8. Capacitance Measurement 40nF 0.01nF ±3.5% +6 dgts 600V 400nF 0.1nF 4μF 0.001μF 40μF 0.01μF 400μF 0.1μF 4000μF 1μF 9. Temperature Measurement (DL279 & DL289 only) -30 to 14 F 0.1 F ±5.4 F 30V (-30 to -10 C) (0.1 C) (±3.0 C) 15 to 752 F 0.1 F ±1.0% +3.6 F (-9 to 400 C) (0.1 C) (±1.0% +2.0 C) 10. Frequency Measurement 9.999Hz 0.001Hz ±0.1% +4 dgts 600V 99.99Hz 0.01Hz 999.9Hz 0.1Hz 9.999kHz 1Hz 99.99kHz 10Hz Minimum frequency: 0.5Hz, DC V offset should be zero Sensitivity: > 1.0V rms 11. Duty (%) Cycle Measurement Range Accuracy Overload Protection 01. to 99.9% ±(0.2% per khz +0.1%) +5 count 600V 0.5Hz to 100kHz (pulsewidth > 2usec) 12. Continuity Measurement Open Circuit voltage <2.7V Threshold Approximately <20Ω Overload Protection 600V 5. AC Volts Measurement (45Hz to 400Hz) 4V 1mV ±2.0% +5 dgts 600V 40V 10mV 400V 100mV 750V 1V *DL289 45Hz to 1KHz True RMS (Crest factor <3:1) DL269/DL279/DL289-MAN P. 4

DL269/DL279/DL289 Clamp-On Meter Limited Warranty The DL26 9 / D L 279 / D L 289 is warranted to be free from defects in materials and workmanship for a period of three years from the date of purchase. If within the warra n ty period your instrument should become inoperative from such defects, the unit will be repaired or replaced at UEi s option. This warra n ty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration, tampering, accident, misuse, abuse, neglect or improper maintenance. Batteries and consequential damage resulting from failed batteries are not covered by warra n ty. Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the express warranty. UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss. A purchase receipt or other proof of original purchase date will be required before warra n ty repairs will be rendered. Instruments out of warra n ty will be repaired (when r e p a i rable) for a service charge. Return the unit postage paid and insured to: 1-800-547-5740 FAX: (503) 643-6322 Service: (800) 308-7709 www.ueitest.com Email: info@ueitest.com This warranty gives you specific legal rights. You may also have other rights which vary from state to state. Copyright 2005 UEi DL269/DL279/DL289-MAN 8/05