Wireless Acoustic Transmitters Series XYR 5000, Model WN571 Specifications - Americas 34-XY-03-03, May 2012 Function. The WN571 Acoustic Transmitter is part of the XYR 5000 family of wireless products. It is used to monitor applications that may generate high frequency noises when they malfunction, such as pressure relief valves, steam traps, and compressor/pumps. The transmitter is acoustically coupled to the process equipment being measured, and can be configured to detect abnormal asset conditions. The unit also contains a built-in temperature sensor to monitor ambient temperature. The Smart Response Manager allows the transmitter to adapt to changing process conditions, allowing greater visibility to process variation. The Smart Response Manager allows the user to set thresholds which, when exceeded, cause the transmitter to automatically adjust sampling and data transmission rates. Base Radio The transmitter combines a reliable ultrasonic sensor, with a Radio Frequency (RF) transceiver operating in the 900MHz ISM license free band. Communication is a digital protocol, using Frequency Hopping Spread Spectrum (FHSS). FHSS ensures data integrity by continually switching the carrier wave over a wide range of frequencies. Power is supplied by C size 3.6 V lithium batteries, with an expected lifetime of up to five years. Wireless Transmitters Enjoy the benefits of wireless technology today: Improve Product Quality Ensure High Uptime Reduce Maintenance and Operational Costs Meet Regulatory Requirements Enhance Flexibility
XYR 5000 WN571 Wireless Acoustic Transmitters 2 Model Acoustic Model # CENTER FREQUENCY BANDWIDTH (3dB) RF DATA TRANSMISSION TECHNIQUE WN571 f c = 40 khz 5 khz (f c ±2.5 khz) Amplitude (8-bit digital output with a scale of 0 to 255) Wireless General Specifications Wireless Communication RF Transmit Power Data Rate Antenna Signal Range 902 MHz 928 MHz Frequency Hopping Spread Spectrum (FHSS) FCC certified ISM license-free band. Every data block transmitted is verified (CRC check) and acknowledged by the Base Radio. 31 mw, 17.8 mw typical. Configurable: 4.8 Kbps, 19.2 Kbps, or 76.8 Kbps. Internal 3 omni-directional, ¼ wave, monopole. Up to 2000 feet (600 meters) from Base Radio with clear line of sight.* *Actual range may vary depending on site topography. Device Configuration Parameter Configuration RF Channel Setup: 1 to 16. Baud Rate: 4.8 Kbps, 19.2 Kbps, 76.8 Kbps. RF ID: 1 to 100. Password. Tag Name (up to 21 characters). Normal Transmit Rate: (1 5 sec, 10 sec, 15 sec, 20 sec, 40 sec, 1 min). Normal Sampling Rate: (1 10 sec, 15 sec, 20 sec, 30 sec, 1 min). Abnormal Transmit Rate: (1 5 sec, 10 sec, 15 sec, 20 sec, 40 sec, 1 min). Abnormal Sampling Rate: (1 10 sec, 15 sec, 20 sec, 30 sec). Ultrasound Normal Upper Value: Disabled/Enabled. Enabled to change Sampling and Ultrasound Normal Lower Value: Disabled/Enabled. Enabled to change Sampling and Temperature Normal Upper Value: Disabled/Enabled. Enabled to change Sampling and Temperature Normal Lower Value: Disabled/Enabled. Enabled to change Sampling and Configuration Panel Integrated LCD display with membrane switch buttons for local configuration. LCD display is 7-digit (alternating) high contrast, anti-reflective monochrome. Display cycles between acoustic level, ambient temperature, and RF status. Site Survey Tools RSSI Link Test Received Signal Strength Indicator displays the RF signal strength in one of seven ranges. Link Test measures the wireless link performance of a transmitter running in normal operating mode. This function looks at wireless performance in both directions, from the transmitter to base radio and vice versa and assigns a rating to that performance or quality of signal.
XYR 5000 WN571 Wireless Acoustic Transmitters 3 Features Automatic Re-transmit Battery Life Saver The field unit checks with the base radio to insure successful receipt of data. If data was not received, the transmitter retries on the next RF cycle. Ensures communication confidence in the harshest of industrial environments. At the maximum transmit rate this feature is inactive. To save conserve battery power, all field units will attempt to synchronize with the network using the following technique: Time Field Unit Synchronization Attempts and Attempt Delay 0 1 minute Continuous Synchronization attempts 1 10 minutes One attempt with a 10 second delay between attempts 10 30 minutes One attempt with a 30 second delay between attempts 30 60 minutes One attempt with a 1-minute delay between attempts 1 12 hours Three-attempt burst with a 5-minute delay between attempts 12 24 hours Three-attempt burst with a 10-minute delay between attempts 24 36 hours Three-attempt burst with a 30-minute delay between attempts 36 48 hours Three-attempt burst with a 1-hour delay between attempts 48 + hours Three-attempt burst with a 2-hour delay between attempts Self Diagnostics Self-checking software and hardware that identifies and reports out of spec conditions, and field unit low battery voltage. Operating/Storage Conditions Humidity Operating Ambient Electronics: Display (Full visibility): Display (Reduced visibility): Storage: 95% RH (non-condensing). -40 to +185 F (-40 to +85 C) -4 to +158 F (-20 to +70 C) -40 to +185 F (-40 to +85 C) -58 to +185 F (-50 to +85 C). Physical Specifications Base Electronic Housing Vibration and Shock Random Vibration Net weight Electromagnetic Compatibility (CE Compliance) Brass and cast aluminum (optional stainless steel and baked ceramic). GE Lexan. V0 Rating and UV Stable. Certified per IEC EN00068 2-6 (Vibration) and 2-27 (Shock) Certified to withstand 6 g s, 15 minutes per axis from 9 500 Hz. 0.6 kg (1.2 lbs). Operates within Specifications in fields from 80 to 1,000 MHz with Field Strengths to 10 V/m. Meets EN 50082-1 General Immunity Standard and EN 55011 Compatibility Emissions Standard. Approvals Environmental protection NEMA 4, IP 65. Combined FM/CSA FM Intrinsically safe - Class I, Div. 1, Groups A,B,C,D,E,F,G,T4, Class I, Zone 0, AEx ia IIC T4, (Ta = -40 C to +85 C) Enclosure 4 CSA - Intrinsically safe - Class I, Div. 1, Groups A,B,C,D,E,F,G,T4, Class I, Zone 0, Ex ia IIC T4, (Ta = -40 C to +85 C) Enclosure 4
XYR 5000 WN571 Wireless Acoustic Transmitters 4 Dimensions
XYR 5000 WN571 Wireless Acoustic Transmitters 5 Model Selection Guide Model Selection Guides are subject to change and are inserted into the specifications as guidance only. Prior to specifying or ordering a model check for the latest revision Model Selection Guides which are published at: www.honeywellprocess.com/en-us/pages/default.aspx 34-XY-16U-03 Issue 11 Page 1 of 1 XYR 5000 Wireless Acoustic Model Selection Guide Signal Transmitter Instructions Select the desired key number. Key Number I (Approvals) _ - - II (Options) KEY NUMBER Selection Availability Description Wireless Acoustic Signal Transmitter WN571 See Wireless Accessories page for mounting bracket options (34-XY-16-07) TABLE I - CERTIFICATION OPTIONS Certificate Approval Type Location or Classification Intrinsically CL I, II, III, Div 1, Gp A,B,C,D,E,F,G T4; FM Safe CL I, Zone 0, AEx ia IIC T4; Enclosure Type 4 Nonincendive Class I, Div 2, Groups A,B,C,D; Suitable for CL II, III, Div 2, Gp F,G, T4; CL I, Zone 2, AEx na IIC T4; Enclosure Type 4 AG TABLE II - OPTIONS Battery Holder Only - No Battery Included Battery Battery - Standard Included Standard Warranty Warranty Additional Warranty - 1 year Additional Warranty - 2 years 00 B1 00 W1 W2 NOTE: Manuals are provided on CD with each shipment. Manuals may also be downloaded free of charge @ http://hpsweb.honeywell.com/cultures/en-us/products/instrumentation/xyr5000wireless/default.htm
XYR 5000 WN571 Wireless Acoustic Transmitters 6 Sales and Service For application assistance, current specifications, pricing, or name of the nearest Authorized Distributor, contact one of the offices below. ASIA PACIFIC Australia Honeywell Limited Phone: +(61) 7-3846 1255 FAX: +(61) 7-3840 6481 Toll Free 1300-36-39-36 Toll Free Fax: 1300-36-04-70 China PRC - Shanghai Honeywell China Inc. Phone: (86-21) 5257-4568 Fax: (86-21) 6237-2826 EMEA Honeywell Process Solutions, Phone: + 80012026455 or +44 (0)1202645583 FAX: +44 (0) 1344 655554 Email: (Sales) sc-cp-appssalespa62@honeywell.com or NORTH AMERICA Honeywell Process Solutions, Phone: 1-800-423-9883 Or 1-800-343-0228 Email: (Sales) ask-ssc@honeywell.com or SOUTH AMERICA Honeywell do Brasil & Cia Phone: +(55-11) 7266-1900 FAX: +(55-11) 7266-1905 Email: (Sales) ask-ssc@honeywell.com or Singapore Honeywell Pte Ltd. Phone: +(65) 6580 3278 Fax: +(65) 6445-3033 South Korea Honeywell Korea Co Ltd Phone: +(822) 799 6114 Fax: +(822) 792 9015 Specifications are subject to change without notice. For More Information Learn more about how XYR 5000 WN571 Wireless Acoustic Transmitters can be configured to detect abnormal asset conditions, visit our website www.honeywellprocess.com/xyr-5000 or contact your Honeywell account manager. Honeywell Process Solutions 1860 West Rose Garden Lane Phoenix, Arizona 85027 Tel: 1-800-423-9883 or 1-800-343-0228 www.honeywellprocess.com 34-XY-03-03 May 2012 2010 Honeywell International Inc.