Similar documents
PCB relay for DC voltage, polarized, monostable or bistable

Relay Types. Reed V23100-V4 Relay. Typical applications. Features. DIP version (flat) DIP version (high) SIL version.

MT4 Relay. 4 pole telecom/signal relay Through Hole Type (THT) Non-polarized. non-latching 1 coil. Features. Typical applications

RF Signal Relays AXICOM. HF3 Relay

30 A rated contacts Flange mount Faston 250 connections. 30 A rated contacts PCB mount - bifurcated terminals. Copper side view

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

W11 Relay. The Best Relaytion

G2RL-1A G2RL-1 G2RL-2A G2RL-2

PCB Relays Twin Relays

Classification Enclosure rating Contact form Contact material

RF Signal Relays AXICOM. HF3 S Relay

PCB Relay. --- G2R-1-SN --- G2R-2-SN LED indicator with test

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

SPST-NO SPDT DPST-NO DPDT

62 Series - Power relays 16 A. Features / /

1a/1c/2a/2c/5A/10A power relays for power supply

SPST-NO SPDT DPST-NO DPDT

PCB Relays Single Relays

COMPACT PC BOARD POWER RELAY FEATURES. Characteristics. Initial breakdown voltage* 1. Vibration resistance

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

COMPACT PC BOARD POWER RELAY

2 POLES 5 A LOW PROFILE TYPE

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

1a 16A power relay for micro wave oven

RF Signal Relays AXICOM. HF3 S Relay

2 POLES 8 A LOW PROFILE TYPE

MT4 Relay. The Best Relaytion

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

48 Series - Relay interface modules A. Features

EN GWT compliant Low profile: 15.7mm.618inch height 1a/1c 16A power relay

mm wide Low coil power PCB or 93 series sockets. Copper side view. 1 CO (SPDT) 6/10 250/400 1, /0.2/ (12/10) AgNi

16A POWER RELAY FOR MICRO WAVE OVEN

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

38 Series - Relay interface modules A. Features /

1a/1c/2a/2c/5A/10A power relays for power supply

10 A MINIATURE POWER RELAY mm inch. 2 Form A, 1 Form A 1 Form A. Initial breakdown voltage* 2. Vibration resistance.

Compliant with European standards 1a/1c 6A Slim power relays

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

Suitable for lighting and motor load, 1 Form A 50A latching relays

AXICOM Telecom-, Signal and RF Relays. D2n V23105 Relay Nov. 07 Rev A ECOC: JM10

Song Chuan / Relay Catalog 507

Features. Insulation system F 835-1A-F-C 835-1A-F-S L-1A-C 835L-1A-S F 835L-1A-F-C 835L-1A-F-S NL-1A-C 835NL-1A-S

1a/1c 5A/10A small power relays

COMPACT PC BOARD POWER RELAY

A rated contacts PCB mount - bifurcated terminals. Copper side view

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2

The power in relays and timers since Catalogue

JS SERIES 1 POLE 8 A (MEDIUM LOAD CONTROL) POWER RELAY. Lead Free / RoHS compliant* FEATURES ORDERING INFORMATION

The Best Relaytion. Cradle Relay N Rev. B EC-JM ECOC: JM10 1. Aug. 04

Compact Relay Family with Forcibly Guided Contacts

POWER RELAY. FTR-K3-WG Series. 1 POLE - 25A - 1.5mm contact gap FTR-K1 SERIES FEATURES

PARTNUMBER INFORMATION FTR-K1 C K 005 W - MA - RG [Example] (a) (b) (c) (d) (e) (f) (g)

General-purpose Relay

Alphanumeric Index. Circuit Breakers Low-signal PC Board Relays Mid-Range PC Board Relays

AXICOM Telecom-, Signal and RF Relays. FX2 Relay Nov. 07 Rev. E ECOC: JM10

POWER RELAY. FTR-K3-WS Series. 1 POLE - High Capacity 25A Type FTR-K1 SERIES FEATURES

The Best Relaytion. Cradle Relay S Rev. B EC-JM ECOC: JM10 1. Aug. 04

G5LE. Ordering Information. PCB Relay. A Cubic, Single-pole 10-A Power Relay J MODEL NUMBER LEGEND G5LE PCB Relay G5LE

Miniature Power Relay Mini L. Product Information

AXICOM Telecom-, Signal and RF Relays. HF3 Relay Aug. 08 Rev. E ECOC: JM10

Features. Designation (provided with) style. Contact. Insulation. system. gap. 110A-1AH-F-C 110BA-1AH-F-C 110A-1AH1-F-C 110BA-1AH1-F-C High power type

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Model Number Structure

40 Series - Miniature P.C.B. Relays A

Relè di potenza 30 A SЕRIES. Power. generators. Industrial washing machines. Burners, boilers and furnaces. Industrial furnaces and ovens

IM Relay Sept 06 Rev. F ECOC: JM10

JS SERIES 1 POLE 8 A (MEDIUM LOAD CONTROL) POWER RELAY. Lead Free FEATURES ORDERING INFORMATION

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

OMRON MK-I / -S RELAY

Subminiature Automotive Relays Type CV20 Monostable

A rated contacts Flange mount/faston 250 (6.3 x 0.8 mm) connection

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

507-1A H - - C. Features. Type List. Ordering Information

HIGH ELECTRICAL & MECHANICAL NOISE IMMUNITY RELAY

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

38 Series - Relay Interface Modules A

62.22 Copper side view

VE 12 H M S E K HV VD (a) ( * ) (b) (c) (d) (e) (f) (g) (h) (i)

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

Relay interface modules A

All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting

MINIATURE RELAY 2 POLES, 2A HIGH INSULATION/WIDE GAP FTR-C1 Series

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

MY-GS CSM_MY-GS_DS_E_2_1

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

PCB Relays Twin Relays

62 Series - Power relays 16 A. Features SERIES / / Printed circuit mount 16 A Power relay

2 or 4 pole changeover contact Plug-in/Faston 187

VSB SERIES 1 POLE 16 A (HEAVY POWER CONTROL) POWER RELAY. RoHS compliant FEATURES ORDERING INFORMATION

ET M3792_a. DC 6, 12, 15, 20, 24 V AC 12, 24, 42, 230 V Voltage range U N

DISCONTINUED (2002) 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) FBR12 SERIES MINIATURE RELAY FEATURES ORDERING INFORMATION

POWER RELAY. FTR-H2 Series. 1 POLE - 10A Relay Type FTR-K1 SERIES FEATURES. PARTNUMBER INFORMATION FTR-H2 A K 012 T [Example] (a) (b) (c) (d) (e)

Transcription:

V23061 PCB relay for DC voltage, neutral, monostable Features Used as a switching element for electrical separation between low-power control circuits and power load circuits With 8 mm clearance and creepage distances up to 8 A continuous current (UL, CSA: 10 A) Low self-heating thanks to low power consumption High packing densities possible Suitable for fully automated processing General-purpose relay for instrumentation and control Mechanical and electrical characteristics comply with the Rules for electrical relays in power installations (VDE 0435/9.72) Used for safe electrical insulation in the following applications power installations (VDE 0160) open and closed-loop control equipment for domestic use (VDE 0631) electrical equipment for domestic use (VDE 0700) electronic equipment for domestic use (VDE 0860); on request Typical applications Interface technology Heating control systems Temperature controllers Timer switches Household equipment Design Size I with 1 make contact or Size II with 1 changeover contact For printed circuit assembling Immersion cleanable or suitable for soldering lines Approvals VDE Approx. 1:1 scale ECR0001-B Mark of conformity VDE 3919 SEV 89.1 02176.02 CSA File LR 45064-7 UL File E 48393 SEMKO 9049293 SETI 142344-01 2 Siemens AG

Dimensional drawing (in mm) Size II with 1 changeover contact Size I with 1 make contact Mounting hole layout View on the terminals 1 changeover contact 1 make contact Terminal assignment View on the terminals 1 changeover contact 1 make contact Siemens AG 3

Contact data Contact category III according to VDE 0435 Part 120/10.81, Appendix B Ordering code, block 3 A301/A302 A401/A402 A501/A502 A601/A602 Number of contacts and type 1 changeover contact or 1 make contact Contact assembly Single contacts Contact material AgSnO 2 AgCdO AgNi 0,15 gold-flashed Max. continuous current at 8 A max. ambient temperature Inrush current 15 A (max. 4 s at 10% duty cycle) Maximum switching voltage 440 V~ 300 Maximum switching capacity AC voltage DC voltage Load limit curve 2000 VA See load limit curve AgCdO gold-plated Recommended for loads > 500 ma, 12 V~/ 500 ma, 12 V~ 1 ma, 6 µw Contact resistance (initial value)/measuring 100 mω/1 A/24 V 100 mω/1 A/24 V 100 mω/100 ma/6 V 30 mω/100 ma/6 V current/driver voltage Note: Inrush currents up to 80 A possible on request. I = switching current U = switching voltage Definition of the load limit curve: In 1000 operations there must be no arc with a burning time > 10 ms. 4 Siemens AG

Coil data Nominal voltages From 3 to 60 Special voltages on request Nominal power consumption, typ., at 20 C 210... 270 mw Pull-in power, at 20 C 100... 120 mw Operating range/class of energizing voltage according to DIN IEC 255 2/b Part 1-00 or VDE 0435 Part 201 Minimum release voltage 10 % of nominal voltage Coil versions Nominal voltage U nom Operate voltage at 20 C U op cold Operating voltage range at 20 C Oper. voltage U I Max. voltage U II Resistance at 20 C 60 40.8 42.8 142.0 15265 ± 2290 010 Other coil versions available on request U op cold = Ω Number of coil, ordering code, block 2 3 2.1 2.1 7.5 40 ± 4 001 5 3.4 3.6 12.5 118 ± 12 002 6 4.1 4.3 15.0 165 ± 17 003 9 6.1 6.4 22.0 365 ± 37 004 12 8.2 8.5 30.0 650 ± 65 005 18 12.2 12.8 45.0 1455 ± 145 006 24 16.3 17.2 56.0 2270 ± 230 007 36 24.5 25.4 88.0 5640 ± 565 008 48 32.6 34.5 110.0 8790 ± 880 009 Operate voltage at 20 C without pre-energizing the coil U I = Operate voltage at 20 C after pre-energizing with U nom without contact current U II = Maximum continuous voltage at 20 C for T c max = 115 C without contact load Operating voltage limits U I and U II depend on temperature and can be calculated by: U I tamb = k I U I 20 C and U II ta = k II U II 20 C k I t amb = Ambient temperature U I tamb = Minimum voltage at ambient temperature t amb U II tamb = Maximum voltage at ambient temperature t amb k I a. k II = Factors (dependent on temperature), see diagram T c max = Maximum coil temperature k II Ambient temperature t amb Siemens AG 5

General data Operate time at U nom and 20 C, typ. 6 ms Release time without/with parallel diode, typ. 2.5 ms / 10 ms Bounce time, make/break contact typ. 0.5 ms / 4 ms Maximum switching rate without load 1200 min -1 Maximum switching rate with rated load 30 min -1 Ambient temperature range according to -40 C... 70 C DIN IEC 255 Part 1-00 or VDE 0435 Part 201 Thermal resistance 75 K/W Coil temp. rise due to rated contact current Approx. 7 K Maximum permissible coil temperature 115 C Protection class according to DIN 40050/IEC 529 Immersion cleanable IP 67 Suitable for soldering lines IP 50 Electrical endurance Load Contact material Contact Endurance, typ., operations Rated load 8 A, 230 V~ AgCdO Make 1 x 10 5 Motor load 230 V~ AgCdO Make 4 x 10 5 Inrush current 18 A cosϕ 0.5 Rated current 1.8 A cosϕ 0.5 AC15 3A according to AgSnO 2 Make 2 x 10 5 VDE 660 / IEC 947, 230 V~ Valve load 0.1 A, 230 V~ AgCdO Make 1 x 10 6 Hydraulic valves 2 A, 24 AgNi 0,15 Make 1 x 10 6 Lamp load 6 A, 230 V~ AgSnO 2 Make 1 x 10 4 Mechanical endurance Approx. 1 x 10 7 operations Flammability according to UL 94 V-0 Solder bath temperature/max. duration 260 C / 5 s Mounting position Any Processing information Wherever possible, ultrasonic cleaning should not be used; if absolutely necessary, then only after consultation with the manufacturer. Weight 11 g Insulation According to IEC 664/VDE 110 (1/89): rated voltage pollution severity overvoltage category According to VDE 0110 (2/79): insulation group/rated voltage Dielectric test voltage, contact coil (1 min) Surge voltage, contact coil (1.2 50 µs) Dielectric test voltage between open contacts (1 min) Clearance/creepage distances Insulation resistance at 500 V (initial value) 250 V 3 III C/250 B/380 4000 V~ rms 8000 V 1000 V~ rms 8 mm / 8 mm > 10 5 MΩ Tracking resistance of the fundamental frame according to DIN IEC 112 CTI 250 6 Siemens AG

Ordering code Block 1 Block 2 Block 3 Data position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 V 2 3 0 6 1 A Identifier for Miniature Power Relay MSR Size A = Size I, with 1 make contact B = Size II, with 1 changeover contact Version 1 = immersion cleanable 2 = suitable for soldering lines Coil number 001 = 3 nominal voltage 002 = 5 003 = 6 004 = 9 005 = 12 006 = 18 007 = 24 008 = 36 009 = 48 010 = 60 Contact pile-up A = Standard Contact material 3 = AgSnO 2 4 = AgCdO 5 = AgNi 0,15, gold-flashed 6 = AgCdO, hard gold-plated Contact arrangement 01 = 1 changeover contact 02 = 1 make contact Ordering example: V23061-B1005-A401 MSR relay with 1 changeover contact (Size II), coil 12 V nominal voltage, contact material silver cadmium oxide (AgCdO) Siemens AG 7