MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Similar documents
MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

Type Poles Contact configuration Rated voltage Model 3PST-NO, 3PST-NC 24 VDC

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

Ordering Information. Power Relay G2A. Model Number Legend Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control

MY-GS CSM_MY-GS_DS_E_2_1

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

MK CSM_MK_DS_E_2_2. Compact Power Relays. A Wide Variation of Octal Pin Power Relays. Model Number Structure

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

CSM_G7S-_-E_DS_E_7_1

Model Number Structure

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

For Momentary Operation

Model Number Structure

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Fluoro plastic housing for highest chemical and detergent resistance

OMRON MK-I / -S RELAY

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

Model Number Structure

Sensing method Appearance Sensing distance Operation mode Model. Emitter E3S-2LE4 Through-beam *1. 2 m. 0.1 to 2 m. 300 mm. 2 m

Switch Mode Power Supply

DPDT+DPST-NO MM4KP-JD MM4XKP-JD

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q

General-purpose Relay

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Name Model Specifications/Design ID Tag V700-D23P31 20 dia. t 2.7 mm Coin-shaped 256 bytes (with user area of 240 bytes)

E8EB-N0C2B E8EB-N0B2B

Alternate Operation Relay 61F-AN/-APN2

Phase-sequence Phase-loss Relay

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

General-purpose Relay

2. Terminal Shape P: PCB terminals B: Screw terminals T: Quick-connect terminals (#250 terminal)

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

Sensing method Sensing distance Model

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

Details on the New G2RS

Model Number Structure

SPECIFICATIONS. For Reference. This specification sheet is for reference only, Please request it again if a specification for receipt is necessary.

E3X-DRT21/SRT21/CIF11

Classification Enclosure rating Contact form Contact material

Model Number Structure

Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type)

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

Pre-wired Photomicrosensor with Amplifier and Cable EE-SPW321/421 Compact, Thin-profile Photomicrosensor with special amplifier.

SPST-NO SPDT DPST-NO DPDT

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

Power Relays G7Z. Model Number Structure. Model Number Legend Relay with Auxiliary Contact Block. New Product Relay

Sensing method Appearance Sensing distance Operation mode Model Convergent-reflective (narrow vision field) 30 to 100 mm (variable)

Model Number Structure

Switch Mode Power Supply

Model Number Structure

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

Detection of Incorrectly Set Work Press Position Confirmation Detection of Bent Drills. Press D5C

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

Single-phase Current Relay

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

Single-phase Voltage Relay

PCB Relay. --- G2R-1-SN --- G2R-2-SN LED indicator with test

3. Contact Form A: SPST-NO

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

E6F-CWZ5C (1000P/R) 2M

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

Resolution (pulses/rotation) 100, 200, 300, 360, , 720, 800 1,000, 1,024, 1,200 1,500, 1,800, 2,000 2,048, 2,500, 3, , , 360, 500

20 Series Power Relays

Contact Ag + Au-clad AgPd + Au-clad. General purpose DPDT G6AU-274P-ST-US G6AU-234P-ST-US 4PDT G6AU-474P-ST-US G6AU-434P-ST-US

General-purpose Relay

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Relays with Forcibly Guided Contacts G7SA

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

SPST-NO SPDT DPST-NO DPDT

V700-series. Electromagnetic Inductive RFID System. ID Tag. Antenna. Controller

Model Number Structure

G8P. PCB Power Relay. Model Number Legend. Application Examples. Ordering Information

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

E6F-CWZ5C (1000P/R) 2M

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Solid-state Timer H3DE

RU Series Universal Relays

Surface-mounting Relay

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

Safety Monitoring Relays

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

256, 360, 720, 1,024. E6C3-AN1E 256P/R 1M Voltage output Binary VDC E6C3-AN2E 256P/R 1M

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

Solid-state Timer H3DS

Floatless Level Switch (Ultra High-sensitivity Type) 61F-UHS/-HSL

* (110 VAC) in this catalog have been discontinued at the end of March L 2KM: Long-distance (for 2 km)

Transcription:

General-purpose Relays MK-S (New Models) CSM_MK-S_DS_E New Super MK Relays. Latching Lever Added to the Series. Same mounting and internal wiring as the previous Super MK Relays Built-in mechanical indicator enables checking contact operation. Two modes can be used to check circuits for models with latching lever. Nameplate provided on models with latching lever. All materials are RoHS compliant. UL and IEC (TÜV) certification. Features Latching Lever Operation indicator * Nameplate Mechanical indicator Latching lever DC: Blue AC: Red For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Operating Method for Latching Lever Relay in Normal Operation Yellow button For Momentary Operation For Lock Operation * The operation indicator is built in only on specified models. Example of Applications of Latching Levers Operation checks in relay sequence circuits Model Number Structure Model Number Legend MKS@@@@@-@-@ 1 1. Contact Form : : PDT. Terminals P: Plug-in. Mechanical Indicator/Test Button Blank: Mechanical indicator I: Mechanical indicator and lockable test button. LED Indicator Blank: Standard N: LED indicator Slide the latching lever to the first position, then press the yellow button with an insulated tool to operate the contact. Slide the latching lever to the second position. (The contact is now in the locked position.). Coil Polarity Blank: Standard 1: Reverse polarity (DC coil only). Surge Absorption Blank: Standard D: Surge absorber diode (DC coil only) V: Surge absorber varistor (AC coil only). Internal Connections Blank: Standard or : Non-standard connections (Refer to Terminal Arrangement and Internal Connection (Bottom View).). Rated Voltage (Refer to Coil Ratings.) 1

Ordering Information List of Models Type Standard Models LED Indicator (See note.) Diode (See note.) LED Indicator and Diode Varistor LED Indicator and Varistor Terminals Plug-in Contact form PDT PDT PDT PDT PDT PDT List of Models (Order Separately) Internal connections (See note.) Item Type Model -pin PF0A-E Track-mounted 11-pin PF11A-E Socket -pin PF0A-D 11-pin PF11A-D Hold-down Clip (For PF0A-E and PF11A-E) PFC-A1 With mechanical indicator With mechanical indicator and lockable test button Standard MKSP MKSPI Non-standard MKSP- MKSPI- Standard MKSP MKSPI MKSP- MKSPI- MKSP- MKSPI- Standard MKSPN(1) MKSPIN(1) Non-standard MKSPN(1)- MKSPIN(1)- Standard MKSPN(1) MKSPIN(1) MKSPN(1)- MKSPIN(1)- MKSPN(1)- MKSPIN(1)- Standard MKSP(1)-D MKSPI(1)-D Non-standard MKSP(1)-D- MKSPI(1)-D- Standard MKSP(1)-D MKSPI(1)-D MKSP(1)-D- MKSPI(1)-D- MKSP(1)-D- MKSPI(1)-D- Standard MKSPN-D MKSPIN-D Non-standard MKSPN-D- MKSPIN-D- Standard MKSPN-D MKSPIN-D MKSPN-D- MKSPIN-D- MKSPN-D- MKSPIN-D- Standard MKSP-V MKSPI-V Non-standard MKSP-V- MKSPI-V- Standard MKSP-V MKSPI-V MKSP-V- MKSPI-V- MKSP-V- MKSPI-V- Standard MKSPN-V MKSPIN-V Non-standard MKSPN-V- MKSPIN-V- Standard MKSPN-V MKSPIN-V MKSPN-V- MKSPIN-V- MKSPN-V- MKSPIN-V- MK-S Coil ratings Note: 1. When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in the specifications. Example: MKSP VDC Rated voltage. The DC coil comes in two types: standard coil polarity and reverse coil polarity. Refer to Terminal Arrangement and Internal Connections (Bottom View). Example: MKSPIN1- VDC Reverse coil polarity. Refer to Terminal Arrangement and Internal Connections (Bottom View) for non-standard internal connections. AC/DC AC/DC DC DC AC AC

Specifications Ratings Coil Ratings AC DC Rated voltage 1 V 10. ma 11, Ω Note: 1. The rated current and coil resistance are measured at a coil temperature of C with tolerances of +1%/ 0% for AC rated current and ±1% for DC coil resistance.. Performance characteristic data are measured at a coil temperature of C.. The maximum voltage is one that is applicable instantaneously to the Relay coil at C and not continuously.. For DC-operated Relays with the LED indicator built-in, add an LED current of approx. ma to the rated current. Contact Ratings Rated current 0 Hz 0 Hz Coil resistance V ma ma.1 Ω 1 V 1 ma 1 ma 1. Ω V 110 ma. ma. Ω 100 V. ma.1 ma 0 Ω 110 V. ma 1.0 ma Ω 00 V 1. ma 11. ma,10 Ω 0 V 1.1 ma 10. ma,0 Ω 0 V 10.0 ma 11. ma,0 Ω 0 V 11.0 ma. ma,0 Ω V ma. Ω 1 V 11 ma 10 Ω V. ma 0 Ω V.1 ma 1,10 Ω 100 V 1. ma,0 Ω 110 V 1. ma,0 Ω Must operate voltage 0% max. of rated voltage Must release voltage 0% min. of rated voltage at 0 Hz % min. of rated voltage at 0 Hz 1% min. of rated voltage Max. voltage 110% of rated voltage Power consumption Approx.. VA at 0 Hz Approx.. VA at 0 Hz Approx. 1. W Load Resistive load (cosφ = 1) Inductive load (cosφ = 0.) Contact mechanism Single Contact material AgSnIn Rated load NO NC 10 A, 0 VAC 10A, 0 VDC A, 0 VAC A, 0 VDC A, 0 VAC Rated carry current 10 A Max. switching voltage 0 VAC, 0 VDC Max. switching current 10 A Max. switching power NO NC,00 VA/00 W 1,0 VA/10 W

Characteristics Contact resistance 100 mω max. Operate time AC: 0 ms max. DC: 0 ms max. Release time 0 ms max. (0 ms max. for built-in Diode Relays) Max. operating frequency Mechanical: 1,000 operations/h Electrical: 1,00 operations/h (under rated load) Insulation resistance 100 MΩ min. (at 00 VDC),00 VAC 0/0 Hz for 1 min between coil and contacts Dielectric strength 1,000 VAC 0/0 Hz for 1 min between contacts of same polarity and terminals of the same polarity,00 VAC 0/0 Hz for 1 min between current-carrying parts, non-current-carrying parts, and opposite polarity Insulation method Basic insulation Impulse withstand voltage. kv between coil and contacts (with 1. 0 μs impulse wave).0 kv between contacts of different polarity (with 1. 0 μs impulse wave) Pollution degree Rated insulation voltage 0 V Vibration resistance Destruction: 10 to to 10 Hz, 0.-mm single amplitude (1.-mm double amplitude) Malfunction: 10 to to 10 Hz, 0.-mm single amplitude (1.0-mm double amplitude) Shock resistance Destruction: 1,000 m/s (approx. 100 G) Malfunction: 100 m/s (approx. 10 G) Endurance Mechanical:,000,000 operations min. (at 1,000 operations/h under rated load) Electrical: operations h. (at 1,00 operations/h under rated load) Failure rate P level (reference value) 10 ma at 1 VDC Ambient temperature Operating: 0 to 0 C (with no icing or condensation) Ambient humidity Operating: % to % Weight Approx. 0 g Note: 1. The values given above are initial values.. P level: λ0 = 0.1 10 - /operation. Ambient temperature of models with LED indicator is to 0 C. Approved Standards UL0 (File No. E11) Coil ratings Contact ratings Operations 10 A, 0 V AC 0/0 Hz (Resistive) N.O. 10 A, 0 V DC (Resistive) contact A, 0 V AC 0/0 Hz (General Use) to 110 VDC to 0 VAC N.C. contact CSA Standard: CSA C. No. 1 (File No. LR) Coil ratings to 1 VDC to 0 VAC Number of Poles Engineering Data Reference Data Maximum Switching Power 10 A, 0 V AC 0/0 Hz (Resistive) 10 A, 0 V DC (Resistive) A, 0 V AC 0/0 Hz (General Use) Contact ratings 10 A, 0 V AC (Resistive) 10 A, 0 V DC (Resistive) A, 0 V AC (General Use) 10 A, 0 V AC (Resistive) Same Polarity 10 A, 0 V DC (Resistive) Same Polarity A, 0 V AC (General Use) Same Polarity Operations IEC Standard/TÜV Certification: IEC110-1 (Certification No. R010) Coil ratings Contact ratings Operations 10 A, 0 V AC 0/0 Hz (Resistive) N.O. 10 A, 0 V DC (Resistive) contact A, 0 V AC 0/0 Hz (General Use), 1,,, 100, 110 VDC, 1,, 100, 110, 00, 0, 0 VAC N.C. contact A, 0 V AC 0/0 Hz (Resistive) A, 0 V DC (Resistive) A, 0 V AC 0/0 Hz (General Use) Note: When Relays are mounted on the PF0A-E or PF11A-E, the maximum carrying current is A. Rated Carry Current vs. Ambient Rated Temperature Switching current (A) 100 0 0 DC resistive load with NO contact AC resistive load with NO contact Rated carry current (A) 10 UL derating curve 10 DC resistive load with NC contact AC resistive load with NC contact AC inductive load (cosφ = 0.) 1 10 0 0 100 00 00 1.000 Switching voltage (V) 0 0 0 0 0 0 0 0 Ambient temperature ( C) Note: The lower limit of the ambient operating temperature for models with built-in operation indicators is C.

Dimensions out Latching Lever Latching Lever MK-S (Unit: mm). max.. max.. max. 0.. max.. max. 0.. max. Sockets See below for Socket dimensions. Maximum carry current Socket Surface-mounting Socket (for track or screw mounting) Finger-protection models --- 10 A A PF0A-E PF0A-D PF0A poles PF11A-E PF11A-E-D PF11A poles Note: Use the Surface-mounting Sockets (i.e., finger-protection models) with -E at the end of the model number. When using the PF0A and PF11A, be sure not to exceed the Socket's maximum carry current of A. Using at a current exceeding A may lead to burning. Round terminals cannot be used for finger-protection models. Use Y-shaped terminals. PF0A-E (Conforming to EN 00) Eight, M. sems Terminal Arrangement PF11A-E (Conforming to EN 00) Eleven, M. sems Terminal Arrangement max.. max.. 1 max.. 1 max. Mounting Holes Two, M or two.-dia. holes. max.. 1 max. Mounting Holes Two, M or two.-dia. holes ±0. ±0.

PF0A-D PF11A-D. Terminal Arrangement 1 1. Terminal Arrangement 1 1 Eight, M screws A 1 1 11 A1 Eight, M screws 10 A 11 1 A1 1 Mounting Holes Two, M or two.-dia. hole Mounting Holes Two, M or two.-dia. hole 0 0 Hold-down Clips PFC-A1 ( pieces per set). 0.. Mounting Tracks PFP-100N, PFP-0N (Conforming to EN 00) PFP-100N (Conforming to EN 00)..±0.1 ±0. ±0.1. ±0. 1. 1 * 10 10 1000 (00)* 1 1 1 10 10 1000± 1 1. * This dimension applies to the PFP-0N Mounting Track. * A total of twelve. elliptic holes is provided with six holes cut from each track end at a pitch of 10 mm. Mounting Height with Sockets Surface-mounting Sockets. (See note.) Two poles.. (See note.) Three poles. PF0A(-E) PF11A(-E) Note: PF0A(-E) and PF11A(-E) allow either track or screw mounting.

Terminal Arrangement and Internal Connection (Bottom View) Standard Models (AC/DC Coil) MKSP(I) MKSP(I)- MKSP(I) MKSP(I)- MKSP(I)- 1 1 LED Indicator (AC Coil) MKSP(I)N MKSP(I)N- MKSP(I)N MKSP(I)N- MKSP(I)N- 1 1 Diode (DC Coil: Standard Polarity) MKSP(I)N MKSP(I)N- MKSP(I)N MKSP(I)N- MKSP(I)N- 1 1 LED Indicator and Diode (DC Coil: Reverse Polarity) MKSP(I)N1 MKSP(I)N1- MKSP(I)N1 MKSP(I)N1- MKSP(I)N1-1 1 Standard Models (DC Coil: Standard Polarity) MKSP(I)-D MKSP(I)-D- MKSP(I)-D MKSP(I)-D- MKSP(I)-D- 1 1 Diode (DC Coil: Reverse Polarity) MKSP(I)1-D MKSP(I)1-D- MKSP(I)1-D MKSP(I)1-D- MKSP(I)1-D- 1 1 LED indicator (DC Coil) MKSP(I)N-D MKSP(I)N-D- MKSP(I)N-D MKSP(I)N-D- MKSP(I)N-D- 1 1

Varistor (AC Coil) MKSP(I)-V MKSP(I)-V- MKSP(I)-V MKSP(I)-V- MKSP(I)-V- 1 1 LED indicator and Varistor (AC Coil) MKSP(I)N-V MKSP(I)N-V- MKSP(I)N-V MKSP(I)N-V- MKSP(I)N-V- 1 1 Safety Precautions Refer to Safety Precautions for All Relays. Safety Precautions for Correct Use Installation Mount the MK-S with the marking at the bottom. Handling Check the coil polarity of models with built-in operation indicator (DC operation coil) and wire them correctly. Test Button Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON. Before using the test button, confirm that circuits, the load, and any other connected item will operate safely. Check that the test button is released before turning ON relay circuits. If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position. Use an insulated tool when you operate the test button. test buttons or LED indicators fulfill the requirements for reinforced insulation between live parts and the front of cover only when the Relay is in a complete condition, i.e. with the nameplate, nameplate frame, test button, and slider in place. If any of these parts are removed, only the requirements for basic insulation are fulfilled.

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 01. In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 01 All Right Reserved.